metreX™ emergency LIGHTING AND SIGNAGE Schools • HIGH ABUSE • healthcare • correctional • biosafety • TRANSPORTATION • INDUSTRIAL Table of contents Product Universe. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 Metrex™ High Abuse Exit Sign. . . . . . . . . . . . . . . . . . 6-7 Mighty Mac™ Correctional Exit Sign. . . . . . . . . . . . . . 8-9 Simple Seal™ Sealed Enclosure Exit Sign. . . . . . . . 10-11 Metrex™ Combo Exit/Emergency Light . . . . . . . . . 12-13 Metrex™ Emergency Light. . . . . . . . . . . . . . . . . . . 14-15 Metrex™ High Capacity Emergency Light . . . . . . . 16-17 Millenium Round™ and Finite™. . . . . . . . . . . . . . . . . 18-19 Lighting Recommendations: Corridor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21 Stairwell. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23 Corridor Intersection . . . . . . . . . . . . . . . . . . . . . . 24-25 Locker Room. . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-27 Multi-Purpose Room . . . . . . . . . . . . . . . . . . . . . . 28-29 Gymnasium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30-31 Jim Hawkins, President, Kenall Manufacturing Building Exterior. . . . . . . . . . . . . . . . . . . . . . . . . . 32-33 Specification Sheets . . . . . . . . . . . . . . . . . . . . . . . . 34-49 LETTER FROM THE PRESIDENT Kenall’s emergency lighting and signage products feature the recently introduced Millenium Metrex™ LED exit sign series for use in abusive public environments. We are also excited to have added our Simple Seal™ exit signs for environmentally critical areas such as cleanrooms and containment areas. NFPA Life Safety Code . . . . . . . . . . . . . . . . . . . . . . 50-52 Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . 53 Performance Listings. . . . . . . . . . . . . . . . . . . . . . . . 54-55 Alpha Numeric Index. . . . . . . . . . . . . . . . . . . . . . . . . . . 56 I am now proud to introduce our Millenium Metrex™ emergency egress lighting system. It includes a comprehensive selection of all new injection molded emergency lighting products for abusive, complex, and extreme environments. This system represents the best of lighting solutions for the specialized applications of education, transportation, detention, industrial, sealed, corrosive, wet, and other extreme environments. Our offering includes a choice of high power battery packs, exit, integrated combo units, and standard, architectural, and satellite/low level exit remote heads. There is also a high efficiency LED version that provides value, simplicity, and cold weather reliability. This brochure includes all of the emergency lighting and signage options outlined above. All products are fully explained, and the helpful application photos, graphics, charts, and photometric data demonstrate the superior performance of our innovative, high quality products. I am sure you will be pleased with the way our emergency lighting and signage series can enhance your facility or business. At Kenall, we’re committed to do our very best to assure your total satisfaction. 2 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 33 PRODUCT UNIVERSE INDIRECT LED EXIT SIGNS Millenium Metrex™ Millenium Metrex™ Millenium Metrex™ Millenium Metrex™ Simple Seal™ Mighty Mac™ Universal Mount Single Face METSU Series Recessed Wall Mount Single Face METSR Series Universal Mount Double Face METDU Series Sealed Enclosure Recessed Wall Mount Single Face CMEXR Series Wall Mount Single Face METSW Series Correctional Wall / Ceiling Mount Single or Double Face MMEX Series Remote-powerED INDIRECT LED EXIT SIGN Millenium Metrex™ Satellite Wall Surface Mount Single Face METSS Series 4 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com self-contained emergency luminaires Millenium Metrex™ Millenium Metrex™ Millenium Metrex™ Millenium Metrex™ Emergency Light Wall Mount Two 12W or 20W Halogen MR16 METEL Series Emergency Light Wall Mount Two or four fixed 6.5W LED MR16 METEL Series High Capacity Emergency Light Wall/Ceiling Mount Two or four lamps 12W or 20W Halogen MR16, or 6.5W LED MR16 METELHC Series Exit/Emergency Combo Wall Mount Two or four lamps 12W or 20W Halogen MR16, or 6.5W LED MR16 METEC Series Remote-powerED EMERGENCY LUMINAIRES Advantages of Kenall LED Emergency Luminaires • LEDs offer long life (up to 50,000 hours) • No filament – ideal for high vibration areas • Fewer batteries to maintain and replace Millenium Metrex™ Emergency Remote Wall/Ceiling Mount Two 12W or 20W Halogen MR16, or two 6.5W LED MR16 METER Series • Increased environmental sustainability (fewer batteries means less manufacturing energy needed; less landfill when batteries are replaced) • Less operating energy required than other lamp types • Cooler operation • Simpler testing protocol • Fewer emergency packs translates to lower installation and system costs LUMINAIRES WITH OPTIONAL EGRESS OPTICS 17" MILLENIUM™ ROUND Wall Mount HID w/two 12W or 20W Halogen MR16 MR17WP Series 17" MILLENIUM™ ROUND Wall Mount HID w/two 6.5W LED MR16 MR17WP Series Millenium Finite™ 15" Full Cutoff, Low Profile Wall Mount CFL or HID w/two 20W Halogen MR16 FN15L Series 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 55 millenium MetrEX™ Kenall’s Millenium Metrex™ exit sign is a best-in-class Architectural High Abuse product combining state-of-the-art LED technology, advanced optical performance, and legendary Kenall durability in a visually pleasing package. With a bright, evenly illuminated face that’s easily visible without being obtrusive, Metrex LEDs are driven below capacity to provide even longer life. Plus, the NiCad battery backup option features deep cycle conditioning at initial startup to maximize battery life; laser battery testing is standard. The battery can power one METSS Satellite luminaire. 6 When it comes to durability, Millenium Metrex has no equal. The highest quality injection molded polycarbonate housings, baseplates, and mounting components make this exit sign able to easily withstand severe environmental conditions and abuse. The standard ambient temperature rating is 10°C to 45°C (50°F to 113°F), and you can specify an optional cold weather package rated to -45°C (-49°F). Its IP64 rating certifies protection against water, dirt, and dust while the Kenall Peace of Mind Guarantee® means we'll replace the luminaire at no charge should it break at any time during the life of the original installation. 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com architectural high abuse exit signs and satellite METSW SERIES Kenall high abuse luminaires are designed and built to take exceptional physical punishment. When installed according to our instructions, Kenall will repair or replace any high abuse luminaire rendered inoperable due to physical abuse for the product life of the original installation. Refer to page 4 for other Millenium Metrex™ Exit Signs, including Single and Double Face, Universal Mount. METSS Satellite Exit Remote-powered by any Kenall Exit sign, the METSS Satellite is ideal where code requires floor proximity exit signage. Can also be wall mounted above doors. Features the same high abuse construction as all Metrex High Abuse luminaires. See page 40 for spec sheet. Housing • Injection molded polycarbonate •Continuous closed cell silicone gasket • Multiple surface conduit feed drill points • Matte white or black available Baseplate • Injection molded polycarbonate •One-piece die-cut closed cell gasket pad Exit Stencil • Injection molded polycarbonate •Field selectable directional chevrons •Red or green polycarbonate diffuser panels Shield •Clear injection molded polycarbonate •Captive, tamper-resistant stainless steel fasteners •Continuous closed cell silicone gasket Universal Mount Canopy • Injection molded polycarbonate •Heavy gauge steel mounting plate •One-piece die-cut closed cell gasket pad Electrical Gear Tray Listings • Injection molded polycarbonate •Long-life LEDs under-driven to increase life: Red at 60% capacity Green at 25% capacity •Remote Exit Ready – can power one METSS Satellite Exit • All electrical components feature quick disconnects for ease of servicing • UL and CUL listed for Wet Location • IP64 rated to IEC 60598 (see page 55) • Meets or exceeds UL924 and NFPA 101 standards •CUL tested and labeled to meet or exceed CSA C22.2 No. 141, C860-01, NRCAN/C860-01 requirements Please refer to pages 34-37 for spec sheets 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 77 mighty mac™ Correctional facility exit signs must withstand extreme physical abuse and tampering. That’s why Kenall developed the Mighty Mac™ Correctional Exit Sign, a luminaire incorporating the best practices of correctional luminaire design with today’s most advanced LED technology. Mighty Mac Exit Signs feature housings and mounting components made from die-formed, heavy gauge, prime grade cold rolled or stainless steel. The impact-resistant polycarbonate lens includes a continuous retention system and fully recessed, tamper-resistant stainless steel fasteners. 8 The result is a luminaire that is virtually impervious to the most aggressive attempts to disable or remove parts. The standard ambient temperature rating is 10°C to 45°C (50°F to 113°F), and you can specify an optional cold weather package rated to -45°C (-49°F). These features make the Mighty Mac Exit Sign appropriate for any application requiring maximum mechanical integrity and durability. The bright exit face is evenly lit by LEDs under-driven to extend their life. When specified with emergency battery backup, the NiCad battery features self-testing, self-diagnostics, and deep conditioning at initial startup to increase battery life. 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com correctional exit signs MMEX SERIES Housing •One-piece die-formed prime grade heavy gauge cold rolled or stainless steel •Corners continuously seam welded and smooth with no post grinding • Matte white or black available lens frame •One-piece die-formed prime grade heavy gauge cold rolled steel or stainless steel •Corners continuously seam welded and smooth with no post grinding •Fully recessed stainless steel tamper-resistant fasteners Exit Stencil • Die-cut prime grade cold rolled steel •Field selectable directional chevrons •Red or green polycarbonate diffuser panels lens •Clear polycarbonate •Lens sealed inside lens frame with gasket tape and secured with continuous lens retention system Electrical Gear Tray finish • 1,000-hour salt spray tested finish UNIVERSAL MOUNT CANOPY • Injection molded polycarbonate •Heavy gauge steel mounting plate Listings • UL and CUL listed for Wet Location • IP65 rated to IEC 60598 (see page 55) • Meets or exceeds UL924 and NFPA 101 standards • Injection molded polycarbonate •Long-life LEDs under-driven to increase life: Red at 60% capacity Green at 25% capacity •Remote Exit Ready – can power one METSS Satellite Exit • All electrical components feature quick disconnects for ease of servicing Please refer to page 38 for spec sheet 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 99 SIMPLE SEAL™ The Kenall family of Simple Seal™ sealed enclosure luminaires offers specifiers the most comprehensively researched, most carefully designed and best performing lighting tools available for environmentally critical applications, including cleanrooms, labs, and all types of containment areas. The Simple Seal Recessed Exit Sign is no exception. It boasts a lens frame with flush mounted stainless steel fasteners, a one-piece, seam welded, cold rolled or stainless steel housing, and polycarbonate lens with a continuous retention system. With these features, the luminiare resists leakage and surface contamination more effectively than any other exit sign on the market. 10 It also meets Kenall's K230 & K229 Leakage Standards for luminaire leakage in pressurized environments and Class 100 Cleanrooms; it is NSF2/Splash Zone listed, and IP65 rated to IEC 60598. The bright exit face is evenly illuminated by LEDs under-driven to provide unusually long life. When specified with optional battery backup, the supplied NiCad battery features deep conditioning at initial startup to maximize battery life, plus self-testing, self-diagnostics, protected manual push button, and remote laser-testing. The standard ambient temperature rating is 10°C to 45°C (50°F to 113°F), and you can specify an optional cold weather package rated to -45°C (-49°F). 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com SEALED ENCLOSURE exit signs CMEXR SERIES Housing lens •One-piece die-formed prime grade heavy gauge cold rolled steel or stainless steel •One-piece seam welded construction • Matte white or black available •Clear polycarbonate •Lens sealed inside lens frame with silicone sealant and secured with continuous lens retention system lens frame •One-piece die-formed prime stainless steel with 60° bevel •Corners continuously seam welded and smooth with no post grinding •Fully recessed flush mounted stainless steel fasteners Exit Stencil Electrical Gear Tray • Injection molded polycarbonate •Long-life LEDs under-driven to increase life: Red at 60% capacity Green at 25% capacity •Remote Exit Ready – can power one METSS Satellite Exit • All electrical components feature quick disconnects for ease of servicing finish • 1,000-hour salt spray tested finish Listings • UL and CUL listed for Wet Location • IP65 rated to IEC 60598 (see page 55) •NSF2 – Splash Zone (see page 54) • Meets K230 & K229 Leakage Standards for luminaire leakage in pressurized environments and Class 100 Cleanrooms (see page 54) • Independent lab tested to Federal Standard 209E for Class 100 • Meets or exceeds UL924 and NFPA 101 standards •One-piece die-cut prime grade cold rolled steel •Field selectable directional chevrons •Red or green polycarbonate diffuser panels Please refer to page 39 for spec sheet 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 11 11 millenium MetrEx™ combo The Millenium Metrex™ Exit Sign and Emergency Lighting Combo merges the finest high abuse luminaire design, state-of-the-art LED technology, and MR16-based emergency lighting that meets all Life Safety Code requirements at up to 114 foot luminaire spacing with a 7.5 foot typical mounting height. The system can be specified with either two or four 12 or 20 watt halogen MR16s, or with two or four 6.5W LED MR16s. The bright exit sign face is evenly illuminated by LEDs under-driven to increase lamp life. The NiCad battery features deep conditioning at initial startup to maximize battery life, plus self-testing, self-diagnostics, protected manual push button, and remote laser-testing. 12 The standard ambient temperature rating is 10°C to 45°C (50°F to 113°F), and you can specify an optional cold weather package rated to -30°C (-22°F). The injection molded polycarbonate housing, lens, and mounting components mean the system will withstand severe environmental and physical abuse, while UL/CUL and IP64 rating protects against intrusion of moisture, dirt, and unsightly debris. In addition, Kenall’s exclusive Peace of Mind Guarantee® is your assurance that the luminaire is covered against breakage for the life of the installation. 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com architectural high abuse combination exit sign / emergency lighting METEC SERIES The METEC Exit/Emergency Combo is available with two or four MR16 lamps, either 12W or 20W halogen, or 6.5W LED. METSS Satellite Exit Remote-powered by the METEC, the METSS Satellite is ideal where code requires floor proximity exit signage; can also be wall mounted above doors. See page 40 for spec sheet. METER REMOTE emergency LIGHT Please see page 44 for spec sheet, and Battery Charts on page 53 for METER power options. Housing Electrical Gear Tray • Injection molded polycarbonate • Die-cut closed cell gasket pad • Multiple surface conduit feed drill points • Matte white or black available •Long-life LEDs under-driven to increase life: Red at 60% capacity Green at 25% capacity • Emergency lamp options include a choice of two or four field-adjustable 12W or 20W halogen or 6.5 LED MR16 lamps •Remote Exit Ready – can power one Kenall METSS Satellite Exit •Remote Emergency Capability – can power up to 71 watts of remote lamps. (Refer to spec sheet on page 41 for battery rating chart and internal lamp options.) • All electrical components feature quick disconnects for ease of servicing Exit Stencil • Injection molded polycarbonate •Field selectable directional chevrons •Red or green polycarbonate diffuser panels Shield •Clear injection molded polycarbonate •Captive, tamper-resistant stainless steel fasteners •Continuous closed cell silicone gasket Please refer to page 20 for Emergency Lighting Product Selector Chart Listings • UL and CUL listed for Wet Location • IP64 rated to IEC 60598 (see page 55) • Meets or exceeds UL924 and NFPA 101 standards •CUL tested and labeled to meet or exceed CSA C22.2 No. 141, C860-01 requirements Please refer to page 41 for spec sheet 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 13 13 millenium MetrEX™ EMERGENCY LIGHTING 14 The Millenium Metrex™ high abuse emergency lighting system integrates Kenall’s industry-best high abuse design with highly advanced emergency lighting technology. With injection molded polycarbonate housing, gear tray cover, and lens, the system is capable of withstanding some of the most severe environmental and physical abuse imaginable. The NiCad battery features deep conditioning at initial startup to maximize battery life, plus self-testing, self-diagnostics, protected manual push button, and remote laser-testing. The standard ambient temperature rating is 10°C to 45°C (50°F to 113°F), and you can specify an optional cold weather package rated to -30°C (-22°F). Millenium Metrex’s standard UL/CUL IP64 rating means the luminaire is protected against the intrusion of water, dirt, and debris. And, like all Kenall high abuse luminaires, it’s protected against breakage for the life of the original installation by our exclusive Peace of Mind Guarantee®. Available with two or four LED, or two halogen MR16 lamps, carefully selected to provide the most appropriate distribution and high lumen output, the METEL meets all Life Safety Code requirements with up to 114 foot spacing between luminaires. A 7.5 foot mounting height is recommended. 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com ARCHITECTURAL HIGH ABUSE EMERGENCY LIGHTING METEL SERIES METEL Series with four LED MR16s METSS Satellite Exit Remote-powered by the METEL, the METSS Satellite is ideal where code requires floor proximity exit signage; can also be wall mounted above doors. See page 40 for spec sheet. METER REMOTE emergency LIGHT Please see page 44 for spec sheet, and Battery Charts on page 53 for METER power options. 6.5W LED version shown. Housing AND GEAR TRAY COVER Electrical Gear Tray • Injection molded polycarbonate • Die-cut closed cell gasket pad • Multiple surface conduit feed drill points • Matte white or black available • Emergency lamp options include a choice of MR16 lamps: – two field-adjustable 12 or 20W halogen – two or four fixed position 6.5W LED •Remote Exit Ready – can power up to two Kenall METSS Satellite Exits •Remote Emergency Capability – can power up to 31 watts of remote lamps. (Refer to spec sheet on page 42 for battery rating chart and internal lamp options.) • All electrical components feature quick disconnects for ease of servicing Shield •Clear injection molded polycarbonate •Captive, tamper-resistant stainless steel fasteners •Continuous closed cell silicone gasket Please refer to page 20 for Emergency Lighting Product Selector Chart Listings • UL and CUL listed for Wet Location • IP64 rated to IEC 60598 (see page 55) • Meets or exceed UL924 and NFPA 101 standards •CUL tested and labeled to meet or exceed CSA C22.2 No. 141, C860-01 requirements Please refer to page 42 for spec sheet 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 15 15 millenium METREX™ EMERGENCY LIGHTING 16 The Millenium Metrex™ two or four lamp, high capacity battery-powered emergency lighting system combines the most advanced battery technology available, the industry's finest emergency lighting performance, and Kenall’s unmatched high abuse design and fabrication techniques. Both the two or four lamp configurations (12W or 20W halogen or 6.5W LED MR16) meet all Life Safety Code requirements. With a 7.5 foot mounting height, they can deliver up to 114 foot spacing between luminaires. Each lamp type has been selected for dependability, light distribution, and high lumen output. The NiCad battery features deep conditioning at initial startup to maximize battery life, plus self-testing, self-diagnostics, protected manual push button, and remote laser-testing. The standard ambient temperature rating is 10°C to 45°C (50°F to 113°F), and an optional cold weather package is available, rated to -30°C (-22°F). Injection molded polycarbonate housings, lenses, and mounting components make this an emergency lighting system able to withstand extreme environmental and physical abuse, while its IP64 rating ensures protection against the intrusion of water, dirt, and dust. Finally, Kenall’s Peace of Mind Guarantee® means we’ll cover the luminaire against breakage for the life of the installation. 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com ARCHITECTURAL HIGH ABUSE EMERGENCY LIGHTING / 2- OR 4-LAMP HIGH CAPACITY BATTERY METELHC SERIES Two-lamp halogen MR16 version shown The METELHC is available with two or four 12W or 20W halogen or 6.5W LED MR16s METSS Satellite Exit Remote-powered by the METELHC, the METSS Satellite is ideal where code requires floor proximity exit signage; can also be wall mounted above doors. See page 40 for spec sheet. Housing and gear tray cover • Injection molded polycarbonate •One-piece die-cut closed cell gasket pad • Multiple surface conduit feed drill points • Matte white or black available Shield •Clear injection molded polycarbonate •Captive, tamper-resistant stainless steel fasteners •Continuous closed cell silicone gasket METER REMOTE emergency LIGHT Please see page 44 for spec sheet, and Battery Charts on page 53 for METER power options. Electrical Gear Tray • Emergency lamp options include a choice of two or four field-adjustable 12W or 20W halogen or 6.5 LED MR16 lamps •Remote Exit Ready – can power up to two Kenall METSS Satellite Exits •Remote Emergency Capability – can power up to 71 watts of remote lamps. (Refer to spec sheet on page 43 for battery rating chart and internal lamp options.) • All electrical components feature quick disconnects for ease of servicing Please refer to page 20 for Emergency Lighting Product Selector Chart Listings • UL and CUL listed for Wet Location • IP64 rated to IEC 60598 (see page 55) • Meets or exceeds UL924 and NFPA 101 standards •CUL tested and labeled to meet or exceed CSA C22.2 No. 141, C860-01 requirements Please refer to page 43 for spec sheet 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 17 17 millenium™ 17" ROUND AND 15" FINITE™ emergency lighting SYSTEMS Millenium™ Rounds and Millenium Finite™ wall-mounted luminaires provide tough, attractive, and efficient building exterior lighting combined with reliable emergency lighting options. Each series features die-cast aluminum baseplates with U.V. stabilized polycarbonate housings. The UL/CUL IP64 rating means the luminaire is protected from intrusion of water, dirt, and debris. And they're protected against breakage for the life of the original installation by the Kenall exclusive Peace of Mind Guarantee®. 18 The emergency systems in the Millenium Round or Finite luminaires can be remotely powered from any of Kenall’s emergency luminaires. With a recommended 12 foot mounting height, the 12 or 20 watt halogen or 6.5 watt LED MR16 lamps can provide safe paths of egress up to 60 feet from the building that exceed all Life Safety Code requirements. 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com LUMINAIRES WITH EGRESS OPTICS MR17WP SERIES millenium™ round with egress optics option •Remote-powered by any of Kenall's emergency lighting systems • Marine grade die-cast aluminum housing •High impact-resistant, injection molded polycarbonate lens base and eyelid •Clear, U.V. stabilized, high impact-resistant injection molded polycarbonate lens •Two field adjustable 12 or 20 watt halogen or 6.5W LED MR16 emergency lamps • UL and CUL listed for Wet Location; IP64 rated to IEC 60598 (see page 55) The 17" Millenium Round is also available with two 6.5W LED MR16 lamps Please refer to pages 46-47 for spec sheets FN15L SERIES MILLENIUM FINITE™ with egress optics option •Remote-powered by any of Kenall's emergency lighting systems •High impact-resistant, U.V. stabilized, injection molded polycarbonate housing and door • .250" clear tempered glass lens •Two fixed 20W halogen or 6.5W LED MR16 emergency lamps • UL and CUL listed for Wet Location; IP64 rated to IEC 60598 (see page 55); IESNA-designated full cut-off; IDA-Approved™ Dark-Sky Friendly Fixture The Finite with Egress Optics features two fixed 20W halogen or 4.2W LED MR16 lamps Please refer to pages 48-49 for spec sheets 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 19 19 CORRIDOR Emergency lighting must adequately illuminate a 3' to 6' wide path of egress down corridors, while exit signs must clearly direct the way to the nearest exit. of egress illuminated for up to 4 hours, Kenall has a Metrex™ emergency lighting system that can meet or exceed Life Safety Code® requirements at unexpectedly wide luminaire spacings. Kenall luminaires are able to meet or exceed all standards for safely guiding occupants through corridors and out of the building. When your application calls for a 3' or 6' wide path The Emergency Lighting Product Selector Chart below will direct you to emergency systems appropriate to your project's specific needs. Life Safety Code® is a registered trademark of the National Fire Protection Association, Quincy MA Emergency Lighting Product Selector Chart Product Name METEC24N METEC24N METEC24N METEC40N METEC40N METEC40N METEC48N METEC48N METEC48N METEC48N METEC80N METEC80N METEC80N METEC80N METEL24N METEL24N METEL24N METEL40N METEL40N METEL40N METELHC48N METELHC48N METELHC48N METELHC48N METELHC80N METELHC80N METELHC80N METELHC80N 20 Lamp Lamp QuantityType 2 4 2 4 2 2 4 2 4 2 2 4 2 4 2 4 2 4 2 2 4 2 4 2 2 4 2 4 6.5W LED 6.5W LED 12W Halogen 6.5W LED 12W Halogen 20W Halogen 6.5W LED 12W Halogen 12W Halogen 20W Halogen 12W Halogen 12W Halogen 20W Halogen 20W Halogen 6.5W LED 6.5W LED 12W Halogen 6.5W LED 12W Halogen 20W Halogen 6.5W LED 12W Halogen 12W Halogen 20W Halogen 12W Halogen 12W Halogen 20W Halogen 20W Halogen Duration (minutes) 240 120 90 160 120 90 240 180 90 108 240 120 180 90 240 120 90 160 120 90 240 180 90 108 240 120 180 90 Spacing for 3 ft. Path 71 114 30 114 30 69 114 30 47 69 30 47 69 113 71 114 30 114 30 69 114 30 47 69 30 47 69 113 Spacing for 6 ft. Path 56 100 21 100 21 59 100 21 41 59 21 41 59 103 56 100 21 100 21 59 100 21 41 59 21 41 59 103 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com Brochure page # Spec Sheet page # 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 14-15 14-15 14-15 14-15 14-15 14-15 16-17 16-17 16-17 16-17 16-17 16-17 16-17 16-17 41 41 41 41 41 41 41 41 41 41 41 41 41 41 42 42 42 42 42 42 43 43 43 43 43 43 43 43 Recommended corridor LUMINAIRES METEL – Halogen Emergency Luminaire page 15 (spec sheet pg. 42) METEL – LED Emergency Luminaire page 15 (spec sheet pg. 42) METELHC High Capacity Emergency Luminaire page 17 (spec sheet pg. 43) METEC Combo Exit / Emergency Luminaire page 13 (spec sheet pg. 41) Description: Corridor Dimensions: 10' wide; 9' ceiling; 3' wide path of egress; Reflectance 80/50/20 Multiple Luminaires mounted at 7.5' height, each with four 6.5W LED MR16 lamps CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance) Location Source Room Floor Kenall Luminaire Room FloorLife Safety Code Avg Fc 1.00 1.00 Max Fc 3.8 — Min Fc 0.1 0.1 Avg/Min Fc 10.00 — Max/Min Fc 38.00 40.00 114’ 2’ 3.0’ Path Description Corridor Dimensions: 10' wide; 9' ceiling; 6' wide path of egress; Reflectance 80/50/20 Multiple Luminaires mounted at 7.5' height, each with two 20W MR16 lamps CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance) Location Source Room Floor Kenall Luminaire Room FloorLife Safety Code Avg Fc 1.00 1.00 Max Fc 2.6 — Min Fc 0.3 0.1 Avg/Min Fc 3.33 — Max/Min Fc 8.67 40.00 59’ 2.0’ 6.0’ Path Description Corridor Dimensions: 10' wide; 9' ceiling; 3' wide path of egress; Reflectance 80/50/20 Multiple Luminaires mounted at 7.5' height, each with two 20W MR16 lamps CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance) Location Source Room Floor Kenall Luminaire Room FloorLife Safety Code Avg Fc 1.00 1.00 Max Fc 3.2 — Min Fc 0.1 0.1 Avg/Min Fc 10.00 — Max/Min Fc 32.00 40.00 69’ 2’ 3.0’ Path 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 21 21 STAIRWELL Stairwells pose a particular challenge in emergency lighting because changes in elevation demand luminaires that can meet required illumination levels on both stairs and landings. In addition, unsupervised stairwells are prone to vandalism. Kenall's emergency luminaires meet the challenging illumination requirements while exhibiting legendary Kenall resistance to physical abuse and tampering. Whether your emergency lighting need calls for a 3' or 6' wide path of egress for up to 4 hours, there are Metrex™ lighting systems capable of exceeding Life Safety Code requirements even with impressively wide luminaire spacings. Please refer to the Emergency Lighting Product Selector Chart below to find the emergency systems that will best meet your specific needs. Emergency Lighting Product Selector Chart Product Name METEC24N METEC24N METEC24N METEC40N METEC40N METEC40N METEC48N METEC48N METEC48N METEC48N METEC80N METEC80N METEC80N METEC80N METEL24N METEL24N METEL24N METEL40N METEL40N METEL40N METELHC48N METELHC48N METELHC48N METELHC48N METELHC80N METELHC80N METELHC80N METELHC80N 22 Lamp Lamp QuantityType 2 4 2 4 2 2 4 2 4 2 2 4 2 4 2 4 2 4 2 2 4 2 4 2 2 4 2 4 6.5W LED 6.5W LED 12W Halogen 6.5W LED 12W Halogen 20W Halogen 6.5W LED 12W Halogen 12W Halogen 20W Halogen 12W Halogen 12W Halogen 20W Halogen 20W Halogen 6.5W LED 6.5W LED 12W Halogen 6.5W LED 12W Halogen 20W Halogen 6.5W LED 12W Halogen 12W Halogen 20W Halogen 12W Halogen 12W Halogen 20W Halogen 20W Halogen Duration (minutes) Brochure page # Spec Sheet page # 240 120 90 160 120 90 240 180 90 108 240 120 180 90 240 120 90 160 120 90 240 180 90 108 240 120 180 90 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 14-15 14-15 14-15 14-15 14-15 14-15 16-17 16-17 16-17 16-17 16-17 16-17 16-17 16-17 41 41 41 41 41 41 41 41 41 41 41 41 41 41 42 42 42 42 42 42 43 43 43 43 43 43 43 43 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com Recommended STAIRWELL Luminaires METEL – LED Emergency Luminaire page 15 (spec sheet pg. 42) METEL – Halogen Emergency Luminaire page 15 (spec sheet pg. 42) METELHC High Capacity Emergency Luminaire page 17 (spec sheet pg. 43) METEC Combo Exit / Emergency Luminaire page 13 (spec sheet pg. 41) Description Closed Stairwell Dimensions: 6' wide x 16' long; 27' ceiling; five 6'x6' landings; 3' wide stairs; Reflectance 80/50/20 Multiple Luminaires mounted at 12.5', 20.0', and 25.85', each with two 20W MR16 lamps CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance) Location Source Landing 1 Kenall Luminaire Landing 4 Kenall Luminaire Stairs Kenall Luminaire Life Safety Code Avg Fc 1.71 8.59 9.26 1.00 Max Fc 4.4 25.3 37.6 — Min Fc 0.2 2.8 1.1 0.1 Avg/Min Fc 8.55 3.07 8.42 — Max/Min Fc 22.00 9.04 34.18 40.00 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 23 23 CORRIDOR INTERSECTION Intersections are common places for large numbers of people to converge. That's why it's important in these areas to combine high capacity emergency lighting with reliable exit signage to safely guide occupants out of these larger and potentially confusing areas. The four-lamp halogen or LED METEC Combo unit is ideal for meeting both requirements with a single luminaire. Whether you're creating a 3' or 6' wide path of egress for up to four hours, Kenall has a Metrex™ lighting system with the performance to exceed Life Safety Code requirements. Use the Emergency Lighting Product Selector Chart below to identify the lighting system best able to meet your project needs. Emergency Lighting Product Selector Chart Product Name METEC24N METEC24N METEC24N METEC40N METEC40N METEC40N METEC48N METEC48N METEC48N METEC48N METEC80N METEC80N METEC80N METEC80N METEL24N METEL24N METEL24N METEL40N METEL40N METEL40N METELHC48N METELHC48N METELHC48N METELHC48N METELHC80N METELHC80N METELHC80N METELHC80N 24 Lamp Lamp QuantityType 2 4 2 4 2 2 4 2 4 2 2 4 2 4 2 4 2 4 2 2 4 2 4 2 2 4 2 4 6.5W LED 6.5W LED 12W Halogen 6.5W LED 12W Halogen 20W Halogen 6.5W LED 12W Halogen 12W Halogen 20W Halogen 12W Halogen 12W Halogen 20W Halogen 20W Halogen 6.5W LED 6.5W LED 12W Halogen 6.5W LED 12W Halogen 20W Halogen 6.5W LED 12W Halogen 12W Halogen 20W Halogen 12W Halogen 12W Halogen 20W Halogen 20W Halogen Duration (minutes) Brochure page # Spec Sheet page # 240 120 90 160 120 90 240 180 90 108 240 120 180 90 240 120 90 160 120 90 240 180 90 108 240 120 180 90 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 14-15 14-15 14-15 14-15 14-15 14-15 16-17 16-17 16-17 16-17 16-17 16-17 16-17 16-17 41 41 41 41 41 41 41 41 41 41 41 41 41 41 42 42 42 42 42 42 43 43 43 43 43 43 43 43 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com Recommended corridoR INTERSECTION Luminaires METEL – Halogen Emergency Luminaire page 15 (spec sheet pg. 42) METEL – LED Emergency Luminaire page 15 (spec sheet pg. 42) METELHC High Capacity Emergency Luminaire page 17 (spec sheet pg. 43) METEC Combo Exit / Emergency Luminaire page 13 (spec sheet pg. 41) Description Corridors: 12' wide; 9' ceiling; 6' wide path of egress Multiple Luminaires at 7.5' mounting height Lamps: Two and Four 20W MR16 Reflectance 80/50/20 CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance) Location Source Room Floor Kenall Luminaire Room FloorLife Safety Code Avg Fc 1.70 1.00 Max Fc 5.7 — Min Fc 0.3 0.1 Avg/Min Fc 5.67 — Max/Min Fc 19.00 40.00 30’ 42’ 3.0’ 6’ Path 3.0’ 140’ 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 25 25 Locker Room Because locker rooms usually have several aisles and paths of egress, it may be necessary to install exit signs in multiple locations to ensure quick and safe exit during an emergency. Remote emergency luminaires like the METER, and satellites such as the METSS, are ideal, cost-effective solutions, particularly when used in combination with tough and efficient Millenium Metrex™ high abuse exit signs. When you need to provide a 3' or 6' wide path of egress illuminated for up to four hours, there's a Metrex™ system that even at impressively wide spacings can exceed Life Safety Code requirements. The Emergency Lighting Product Selector Chart below will direct you to the different Kenall systems appropriate for your specific application. Emergency Lighting Product Selector Chart Product Name METEC24N METEC24N METEC24N METEC40N METEC40N METEC40N METEC48N METEC48N METEC48N METEC48N METEC80N METEC80N METEC80N METEC80N METEL24N METEL24N METEL24N METEL40N METEL40N METEL40N METELHC48N METELHC48N METELHC48N METELHC48N METELHC80N METELHC80N METELHC80N METELHC80N 26 Lamp Lamp QuantityType 2 4 2 4 2 2 4 2 4 2 2 4 2 4 2 4 2 4 2 2 4 2 4 2 2 4 2 4 6.5W LED 6.5W LED 12W Halogen 6.5W LED 12W Halogen 20W Halogen 6.5W LED 12W Halogen 12W Halogen 20W Halogen 12W Halogen 12W Halogen 20W Halogen 20W Halogen 6.5W LED 6.5W LED 12W Halogen 6.5W LED 12W Halogen 20W Halogen 6.5W LED 12W Halogen 12W Halogen 20W Halogen 12W Halogen 12W Halogen 20W Halogen 20W Halogen Duration (minutes) Brochure page # Spec Sheet page # 240 120 90 160 120 90 240 180 90 108 240 120 180 90 240 120 90 160 120 90 240 180 90 108 240 120 180 90 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 14-15 14-15 14-15 14-15 14-15 14-15 16-17 16-17 16-17 16-17 16-17 16-17 16-17 16-17 41 41 41 41 41 41 41 41 41 41 41 41 41 41 42 42 42 42 42 42 43 43 43 43 43 43 43 43 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com Recommended LOCKER ROOM Luminaires METEL Emergency Luminaire page 15 (spec sheet pg. 42) METELHC High Capacity Emergency Luminaire page 17 (spec sheet pg. 43) METEC Combo Exit / Emergency Luminaire page 13 (spec sheet pg. 41) MLER Remote page 13 (spec sheet pg. 45) Description Locker Room: 26'x60'; 9' ceiling; 3' wide path of egress Multiple Luminaires at 7.5' mounting height or ceiling mounted Lamps: 12W MR16 Reflectance 80/50/20 CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance) Location Source Locker Area Kenall Luminaire Shower Area Kenall Luminaire Lavatory Area Kenall Luminaire RoomLife Safety Code Avg Fc 1.04 1.10 1.50 1.00 Max Fc 3.6 2.2 3.1 — Min Fc 0.2 0.4 0.4 0.1 Avg/Min Fc 5.20 2.75 3.75 — Max/Min Fc 18.00 5.50 7.75 40.00 12’ LAVATORY AREA 13’ LOCKER AREA 26’ SHOWER AREA 1’ 60’ 24’ 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 27 27 Multi-Purpose Room Multi-purpose rooms pose many of the same challenges as locker rooms, including the illumination of multiple exits. Because of their typically large footprints, however, multi-purpose rooms demand more powerful emergency luminaires in order to adequately illuminate their broader dimension while making potential obstacles to egress visible to occupants. For applications such as this, calling for high output emergency lighting for up to four hours, there's a Metrex™ system with the performance you need to meet the Life Safety Code requirements – even at impressively wide luminaire spacings. The Emergency Lighting product Selector Chart below will direct you to the Kenall systems appropriate for multi-purpose room projects. Emergency Lighting Product Selector Chart Product Name METEC24N METEC24N METEC24N METEC40N METEC40N METEC40N METEC48N METEC48N METEC48N METEC48N METEC80N METEC80N METEC80N METEC80N METEL24N METEL24N METEL24N METEL40N METEL40N METEL40N METELHC48N METELHC48N METELHC48N METELHC48N METELHC80N METELHC80N METELHC80N METELHC80N 28 Lamp Lamp QuantityType 2 4 2 4 2 2 4 2 4 2 2 4 2 4 2 4 2 4 2 2 4 2 4 2 2 4 2 4 6.5W LED 6.5W LED 12W Halogen 6.5W LED 12W Halogen 20W Halogen 6.5W LED 12W Halogen 12W Halogen 20W Halogen 12W Halogen 12W Halogen 20W Halogen 20W Halogen 6.5W LED 6.5W LED 12W Halogen 6.5W LED 12W Halogen 20W Halogen 6.5W LED 12W Halogen 12W Halogen 20W Halogen 12W Halogen 12W Halogen 20W Halogen 20W Halogen Duration (minutes) 240 120 90 160 120 90 240 180 90 108 240 120 180 90 240 120 90 160 120 90 240 180 90 108 240 120 180 90 Spacing for 3 ft. Path 71 114 30 114 30 69 114 30 47 69 30 47 69 113 71 114 30 114 30 69 114 30 47 69 30 47 69 113 Spacing for 6 ft. Path 56 100 21 100 21 59 100 21 41 59 21 41 59 103 56 100 21 100 21 59 100 21 41 59 21 41 59 103 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com Brochure page # Spec Sheet page # 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 14-15 14-15 14-15 14-15 14-15 14-15 16-17 16-17 16-17 16-17 16-17 16-17 16-17 16-17 41 41 41 41 41 41 41 41 41 41 41 41 41 41 42 42 42 42 42 42 43 43 43 43 43 43 43 43 Recommended MULTI-PURPOSE ROOM Luminaires METEL – Halogen Emergency Luminaire page 15 (spec sheet pg. 42) METEL – LED Emergency Luminaire page 15 (spec sheet pg. 42) METELHC High Capacity Emergency Luminaire page 17 (spec sheet pg. 43) METEC Combo Exit / Emergency Luminaire page 13 (spec sheet pg. 41) Description Multi-Purpose Room: 60'x80'; 25' ceiling; 6' wide path of egress Multiple Luminaires at 12' mounting height Lamps: Two 20W MR16 Reflectance 80/50/20 CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance) Location Source Room Floor Kenall Luminaire Room FloorLife Safety Code Avg Fc 1.18 1.00 Max Fc 3.9 — Min Fc 0.3 0.1 Avg/Min Fc 3.93 — Max/Min Fc 13.00 40.00 80’ 60’ 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 29 29 gymnasium Gymnasiums are a tough environment for lighting fixtures. Even mounted high on walls, luminaires have to be incredibly rugged to survive the impact of balls traveling at high speeds, while those located within arm’s reach also need to withstand tampering and vandalism. With injection molded polycarbonate construction, Kenall Metrex Emergency luminaires will stand up to the physical demands of this environment, while providing the higher level of illumination needed in such a large, open space. Kenall state-of-the art LED Emergency Remotes are an ideal energy- and cost-efficient solution for gyms. A single METEC Combo Exit/Emergency luminaire can power up to eight two-lamp METER Remotes, while exceeding Life Safety Code requirements. This means just one battery to purchase and maintain for an entire gymnasium application. Refer to the Emergency Lighting Product Selector Chart below to select the ideal system for your project. Emergency Lighting Product Selector Chart Product Name METEC24N METEC24N METEC24N METEC40N METEC40N METEC40N METEC48N METEC48N METEC48N METEC48N METEC80N METEC80N METEC80N METEC80N METEL24N METEL24N METEL24N METEL40N METEL40N METEL40N METELHC48N METELHC48N METELHC48N METELHC48N METELHC80N METELHC80N METELHC80N METELHC80N 30 Lamp Lamp QuantityType 2 4 2 4 2 2 4 2 4 2 2 4 2 4 2 4 2 4 2 2 4 2 4 2 2 4 2 4 6.5W LED 6.5W LED 12W Halogen 6.5W LED 12W Halogen 20W Halogen 6.5W LED 12W Halogen 12W Halogen 20W Halogen 12W Halogen 12W Halogen 20W Halogen 20W Halogen 6.5W LED 6.5W LED 12W Halogen 6.5W LED 12W Halogen 20W Halogen 6.5W LED 12W Halogen 12W Halogen 20W Halogen 12W Halogen 12W Halogen 20W Halogen 20W Halogen Duration (minutes) 240 120 90 160 120 90 240 180 90 108 240 120 180 90 240 120 90 160 120 90 240 180 90 108 240 120 180 90 Spacing for 3 ft. Path 71 114 30 114 30 69 114 30 47 69 30 47 69 113 71 114 30 114 30 69 114 30 47 69 30 47 69 113 Spacing for 6 ft. Path 56 100 21 100 21 59 100 21 41 59 21 41 59 103 56 100 21 100 21 59 100 21 41 59 21 41 59 103 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com Brochure page # Spec Sheet page # 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 12-13 14-15 14-15 14-15 14-15 14-15 14-15 16-17 16-17 16-17 16-17 16-17 16-17 16-17 16-17 41 41 41 41 41 41 41 41 41 41 41 41 41 41 42 42 42 42 42 42 43 43 43 43 43 43 43 43 Recommended gymnasium Luminaires METEL – Halogen or LED Emergency Luminaire page 15 (spec sheet pg. 42) METELHC High Capacity Emergency Luminaire page 17 (spec sheet pg. 43) METEC Combo Exit / Emergency Luminaire page 13 (spec sheet pg. 41) METER Remote Emergency METSS Satellite Exit page 13 (spec sheet pg. 44) page 7 (spec sheet pg. 40) Description Gymnasium: 110'x110'; 25' ceiling; 6' wide path of egress Multiple Luminaires at 12' mounting height, 50' spacings; one Exit satellite and seven Remote luminaires powered by one METEC80N Lamps: 6.5W LED MR16 Reflectance 80/50/20 CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance) Location Source Room Floor Kenall Luminaire Room FloorLife Safety Code METER Remote w/(2) 6.5W LED METER Remote w/(2) 6.5W LED Avg Fc 1.05 1.00 Max Fc 3.7 — Min Fc 0.1 0.1 Avg/Min Fc 10.5 — Max/Min Fc 37.00 40.00 METER Remote w/(2) 6.5W LED METEC80N w/(2) 6.5W LED 110’ METER Remote w/ (2) 6.5W LED and METSS Satellite Exit METER Remote w/(2) 6.5W LED METER Remote w/(2) 6.5W LED METER Remote w/(2) 6.5W LED 2’ Wire recommendations: METEC to METSS – 14 ga. METEC to METER – 12 ga. 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 31 31 Building Exterior Building exterior emergency luminaires pose a unique lighting challenge in that they not only need to reliably illuminate a path of egress away from the building, but also stand up against physical and environmental abuse. Millenium™ Round and Finite™ are ideal solutions for both requirements when specified with the auxiliary emergency lighting option. When your application calls for emergency lighting to provide a 3' or 6' wide path of egress, illuminated for up to four hours, Kenall has a Metrex™ lighting system that will provide impressive luminaire spacings while exceeding Life Safety Code requirements. The Emergency Lighting Product Selector Chart below will direct you to alternate lighting systems that meet your specific needs. Emergency Lighting Product Selector Chart Product Name 32 Lamp LampMounting QuantityType Height (ft.) Path of Egress Width (ft.) Length (ft.) Brochure page # Spec Sheet page # METEL / METELHC METEL / METELHC METEL / METELHC METEL / METELHC METEL / METELHC METEL / METELHC METEL / METELHC METEL / METELHC METEL / METELHC METEL / METELHC METEL / METELHC METEL / METELHC 2 2 4 4 2 2 4 4 2 2 4 4 6.5W LED 6.5W LED 6.5W LED 6.5W LED 12W Halogen 12W Halogen 12W Halogen 12W Halogen 20W Halogen 20W Halogen 20W Halogen 20W Halogen 12 12 12 12 12 12 12 12 12 12 12 12 6 3 6 3 6 3 6 3 6 3 6 3 46 52 79 86 16 18 30 32 47 51 77 80 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 14-15 42-43 42-43 42-43 42-43 42-43 42-43 42-43 42-43 42-43 42-43 42-43 42-43 MR17WP MR17WP MR17WP MR17WP MR17WP MR17WP 2 2 2 2 2 2 6.5W LED 6.5W LED 12W Halogen 12W Halogen 20W Halogen 20W Halogen 12 12 12 12 12 12 6 3 6 3 6 3 46 52 16 18 47 51 18-19 18-19 18-19 18-19 18-19 18-19 46-47 46-47 46-47 46-47 46-47 46-47 FN15L FN15L FN15L FN15L 2 2 2 2 6.5W LED 6.5W LED 20W Halogen 20W Halogen 12 12 12 12 6 3 6 3 43 50 43 49 18-19 18-19 18-19 18-19 48-49 48-49 48-49 48-49 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com Recommended building exterior LUMINAIRES METEL – Halogen or LED Emergency Luminaire page 15 (spec sheet pg. 42) METEL – LED METELHC High Capacity Emergency Luminaire Emergency Luminaire page 15 (spec sheet pg. 42) page 17 (spec sheet pg. 43) MR17WP Millenium™ Round w/Egress Optics option page 19 (spec sheets pgs. 46-47) FN15L Millenium Finite™ w/Egress Optics option page 19 (spec sheets pgs. 48-49) Description Building Exterior: 3' wide path of egress Luminaire: 17" Millenium™ Round mounted over door at 12' Lamps: Two 20W Halogen MR16 CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance) Location Source Room Floor Kenall Luminaire Room FloorLife Safety Code Avg Fc 1.00 1.00 Max Fc 3.8 — Min Fc 0.1 0.1 Avg/Min Fc 10.00 — Max/Min Fc 38.00 40.00 Building Facade 51’ 3’ 52’ Description Building Exterior: 3' wide path of egress Luminaire: 17" Millenium™ Round mounted over door at 12' Lamps: Two 6.5W LED MR16 Reflectance 80/50/20 3’ 51’ CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance) Location Source Room Floor Kenall Luminaire Room FloorLife Safety Code Avg Fc 1.01 1.00 Max Fc 3.9 — Min Fc 0.1 0.1 Avg/Min Fc 10.10 — 3’ Max/Min Fc 39.00 40.00 Building Facade 52’ 3’ 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 33 33 PROJECT INFORMATION MILLENIUM METREX™ Job Name Fixture Type METDU SERIES Catalog Number PRODUCT FEATURES: Approved by » Surface mount – wall or ceiling; Double Face » Indirect Red or Green LED » Internal Battery Backup System » High impact injection polycarbonate construction SPECIFICATIONS HOUSING: High impact, injection molded polycarbonate. Housing provided with canopy mounting and wireway drill points top and side – see Cross Section/Details. Closed cell die-cut Neoprene gasket seals housing to canopy. SHIELD: UV-stabilized, high impact, injection molded clear polycarbonate. Nominal thickness .120". Captive stainless steel Torx® with center pin fasteners secure shield to housing. Continuous closed cell silicone gasket seals shield to housing. CANOPY: High impact, injection molded polycarbonate canopy cover with heavy gauge galvanized steel mounting plate with integral 1/4-20 threaded studs. Canopy mounting plate provided with four-point mounting holes, one wireway hole and temporary junction box mounting holes. Closed cell die-cut Neoprene gasket seals canopy to mounting surface. LEGEND: Legend illuminated by internal high output LEDs. Lettering six inches high with .750" stroke. Polycarbonate red or green filter panels. High impact, injection molded polycarbonate stencil and field selectable chevron inserts. ELECTRICAL: 624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Remote Exit Ready – can power one Kenall METSS Satellite Exit. OPTIONS: Sealed nickel-cadmium Emergency Battery Pack (EL) with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected mechanical test switch and status indicator. Provides 120 minutes of emergency operation. The Emergency Battery Pack (EL) is suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery Pack (CL) suitable for -30°C to 45°C (-22°F to 113°F). Remote Exit Ready – can power one or two Kenall METSS Satellite Exits. INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®. Drill points provided for optional conduit entry. LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements. NSF2 Splash and Non-Food Zone. LED IP64 UL 924 NFPA 101 ORDERING INFORMATION (Ex: METDU-MW-R-DT) Model Finish Legend Color Finish MB Matte Black MW Matte White Legend Color R Red G Green Voltage Options Accessories METDU Options CEL Cold Weather Emergency Battery Pack EL Standard Emergency Battery Pack XAC Auxiliary AC Supply (matches voltage selection) XDC Auxiliary DC Supply (6-24 volts) Voltage DT 120/277 Volts DTC 120/347 Volts Accessories LP Laser Pointer 9500 Torx® Screwdriver DIMENSIONAL DATA Ceiling Mount Ceiling Canopy Mounting View 8.80" 7.00" 9.55" 4.00" 14.00" 4.04" End Mount (4) .31" Mounting Holes 5.80" 2.00" Dia. Hole End Canopy Mounting View 5.80" 4.00" 8.80" 8.80" 4.04" 7.00" 14.75" (4) .31" Mounting Holes www.kenall.com P: 800-4-Kenall F: 262-891-9701 2.00" Dia. Hole 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. METDU_121613 34 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com PROJECT INFORMATION MILLENIUM METREX™ Job Name Fixture Type METSU SERIES Catalog Number PRODUCT FEATURES: Approved by » Surface mount – wall or ceiling; Single Face » Indirect Red or Green LED » Internal Battery Backup System » High impact polycarbonate construction SPECIFICATIONS HOUSING: High impact, injection molded polycarbonate. Housing provided with canopy mounting and wireway drill points top and side – see Cross Section/Details. Closed cell die-cut Neoprene gasket seals housing to canopy. SHIELD: UV-stabilized, high impact, injection molded clear polycarbonate. Nominal thickness .120". Captive stainless steel Torx® with center pin fasteners secure shield to housing. Continuous closed cell silicone gasket seals shield to housing. CANOPY: High impact, injection molded polycarbonate canopy cover with heavy gauge galvanized steel mounting plate with integral 1/4-20 threaded studs. Canopy mounting plate provided with four-point mounting holes, one wireway hole and temporary junction box mounting holes. Closed cell die-cut Neoprene gasket seals canopy to mounting surface. LEGEND: Illuminated by internal high output LEDs. Lettering six inches high with .750" stroke. Polycarbonate red or green filter panels. High impact, injection molded polycarbonate stencil and field selectable chevron inserts. ELECTRICAL: 624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Remote Exit Ready – can power one Kenall METSS Satellite Exit. OPTIONS: Sealed nickel-cadmium Emergency Battery Pack (EL) with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected mechanical test switch and status indicator. Provides 120 minutes of emergency operation. The Emergency Battery Pack (EL) is suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery Pack (CL) suitable for -30°C to 45°C (-22°F to 113°F). Remote Exit Ready – can power one or two Kenall METSS Satellite Exits. INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®. Drill points provided for optional conduit entry. LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements. NSF2 Splash/ Non-Food Zone. LED IP64 UL 924 NFPA 101 ORDERING INFORMATION (Ex: METSU-MW-R-DT-EL) Model Finish Legend Color Voltage Options Accessories METSU Finish MB Matte Black MW Matte White Voltage DT 120/277 Volts DTC 120/347 Volts Legend Color R Red G Green Options CEL Cold Weather Emergency Battery Pack EL Standard Emergency Battery Pack XAC Auxiliary AC Supply (matches voltage selection) XDC Auxiliary DC Supply (6-24 volts) DIMENSIONAL DATA Ceiling Mount Accessories LP Laser Pointer 9500 Torx® with center pin Screwdriver Ceiling Canopy Mounting View 8.80" 7.00" 9.55" 4.00" 5.80" 14.00" 3.27" End Mount (4) .31" Mounting Holes 2.00" Dia. Hole End Canopy Mounting View 5.80" 4.00" 8.80" 8.80" 7.00" 3.27" 14.75" www.kenall.com P: 800-4-Kenall (4) .31" Mounting Holes F: 262-891-9701 2.00" Dia. Hole 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. METSU-010214 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 35 PROJECT INFORMATION MILLENIUM METREX™ Job Name Fixture Type METSW SERIES Catalog Number PRODUCT FEATURES: Approved by » Surface wall mount – Single Face » Indirect Red or Green LED » Internal Battery Backup System » High impact polycarbonate construction SPECIFICATIONS HOUSING: High impact, injection molded polycarbonate. Housing provided with four-point mounting holes, one wireway hole and temporary junction box mounting drill points – see Cross Section/ Details. Closed cell die-cut Neoprene gasket seals housing to mounting surface. SHIELD: UV-stabilized, high impact, injection molded clear polycarbonate. Nominal thickness .120". Captive stainless steel Torx® with center pin fasteners secure shield to housing. Continuous closed cell silicone gasket seals shield to housing. LEGEND: Legend illuminated by internal high output LEDs. Lettering six inches high with .750 inch stroke. Polycarbonate red or green filter panels. High impact, injection molded polycarbonate stencil and field selectable chevron inserts. ELECTRICAL: 624nm RED or 527nm GREEN LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Remote Exit Ready – can power one Kenall METSS Satellite Exit. OPTIONS: Sealed nickel-cadmium Emergency Battery Pack (EL) with standard battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected mechanical test switch and status indicator. Provides 120 minutes of emergency operation; The Emergency Battery Pack (EL) is suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery Pack (CL) suitable for -30°C to 45°C (-22°F to 113°F). Remote Exit Ready – can power one or two Kenall METSS Satellite Exits. INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®. Drill points provided for optional surface conduit entry. NSF2 Splash and Non-Food Zone. LISTINGS: UL and CUL listed for Wet Locations. UL Classified IP64 per IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements. NSF2 Splash and Non-Food Zone. LED IP64 UL 924 NFPA 101 ORDERING INFORMATION (Ex: METSW-MW-R-DT-EL) Model Finish Legend Color Voltage Options Accessories METSW Finish MB Matte Black MW Matte White Voltage DT 120/277 Volts DTC 120/347 Volts Legend Color R Red G Green Options CEL Cold Weather Emergency Battery Pack EL Standard Emergency Battery Pack XAC Auxiliary AC Supply (matches voltage selection) XDC Auxiliary DC Supply (6-24 volts) DIMENSIONAL DATA Accessories LP Laser Pointer 9500 Torx® with center pin Screwdriver Baseplate Mounting View 14.00" 3.27" 7.00" 8.80" 4.00" (4) .31" Mounting Holes www.kenall.com P: 800-4-Kenall F: 262-891-9701 .875" Dia. Hole 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. METSW-010214 36 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com PROJECT INFORMATION MILLENIUM METREX™ Job Name Fixture Type METSR SERIES Catalog Number PRODUCT FEATURES: Approved by » Semi-recessed wall mount – Single Face » Indirect Red or Green LED » Internal Battery Backup System » 20-gauge cold rolled steel housing » Self diagnostic testing features SPECIFICATIONS HOUSING: 20-gauge CRS. Hole-free one-piece seam welded construction. FRAME: One-piece die-formed prime grade 16-gauge material as specified – see Ordering Information. Corners continuously seam welded and smooth with no post grinding (TIG). LENS: External panel .188" thick clear polycarbonate. LEGEND: Legend illuminated by internal high output LEDs. Lettering six inches high with .750" stroke. Polycarbonate red or green filter panels. High impact, punched, formed and painted sheet metal stencil and field selectable chevron inserts. FASTENERS: Hardened security screws as specified – see ordering information. FINISH: TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%. See Options for black exterior. ELECTRICAL: 624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Remote Exit Ready – can power one Kenall METSS Satellite Exit. OPTIONS: Sealed nickel-cadmium Emergency Battery Pack (EL) with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected mechanical test switch and status indicator. Provides 120 minutes of emergency operation. Emergency Battery Pack (EL) suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery Pack (CEL) suitable for -45°C to 45°C (-49°F to 113°F). (When used with a Kenall METSS, this fixture provides 90 minutes of emergency operation.) LISTINGS: UL and CUL listed for Wet Location. UL certified IP65 in compliance with IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements. LED IP65 UL 924 NFPA 101 ORDERING INFORMATION (Ex: METSR-1-R-DT-1-EL) Model Frame Material Legend Color Voltage Fastener Options Accessories METSR Frame Material 1 16-Ga CRS (Painted) 4 16-Ga SS (Painted) 7 16-Ga SS (Brushed) Accessories LP Laser Pointer 9500 Torx® with center pin Screwdriver Legend Color G Green R Red Fasteners 1 Torx® Head w/ Center Pin 2 Allen Head w/ Center Pin Voltage DT 120/277 Volts DTC 120/347 Volts Options BLK Black Exterior Frame and Exit Face CEL Cold Weather Emergency Battery Pack EL Standard Emergency Battery Pack XAC Auxiliary AC Supply (matches voltage selection) XDC Auxiliary DC Supply (6-24 volts) DIMENSIONAL DATA Side View Mounting Details 16.00" .35" (4) .31" Dia. K.O. 10.75" Frame 12.31" x 16.04" (4) 1/2" EMT K.O. 14.50" 2.38" www.kenall.com Stud Spacing 16" Rough Opening 10.75" x 14.50" P: 800-4-Kenall F: 262-891-9701 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. METSR-010214 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 37 37 PROJECT INFORMATION Job Name MIGHTY MAC™ Fixture Type MMEX SERIES Catalog Number PRODUCT FEATURES: Approved by » Surface mount – wall or ceiling » 14-gauge cold rolled steel or stainless steel housing » Indirect Red or Green LED » Single and Double Face SPECIFICATIONS HOUSING: One-piece die-formed prime 14-gauge grade material as specified – see ordering information. Corners continuously seam welded and smooth with no post grinding (TIG). DOOR: One-piece die-formed prime grade 14-gauge. Corners continuously seam welded and smooth with no post grinding (TIG). LEGEND: Legend illuminated by internal high output LEDs. Lettering six inches high with .750 inch stroke. Internal panels with stencil cut letters and red or green filter panel. External panel .188" thick clear polycarbonate. Universal arrows. FASTENERS: Hardened security screws as specified – see ordering information. FINISH: TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%. See Options for black exterior. ELECTRICAL: 624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Exit Ready – can power one Kenall METSS Satellite Exit. OPTIONS: Sealed nickel-cadmium Emergency Battery Pack (EL) with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected mechanical test switch and status indicator. Provides 120 minutes of emergency operation. Emergency Battery Pack (EL) suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery Pack (CEL) suitable for -45°C to 45°C (-49°F to 113°F). (When used with a Kenall METSS, this fixture provides 90 minutes of emergency operation.) LISTINGS: UL and CUL listed for Wet Location. UL Classified IP65 per IEC 60598. Meets or exceeds UL924 and NFPA 101 Standards. Meets or exceeds CSA and NRCAN requirements. LED IP65 UL 924 NFPA 101 ORDERING INFORMATION (Ex: MMEX-1-0-G-DT-1) Model Face Hsg. and Dr. Material Legend Color Voltage Fasteners Options Accessories MMEX Face 1 Single Face 2 Double Face Housing and Door Material 0 14-Ga CRS (Painted) 3 14-Ga SS (Painted) 6 14-Ga SS (Brushed) Legend Color G Green R Red www.kenall.com Voltage DT 120/277 Volts DTC 120/347 Volts Fasteners 1 Torx® Head w/ Center Pin 2 Allen Head w/ Center Pin P: 800-4-Kenall F: 262-891-9701 Options BLK Black Exterior EL Standard Emergency Battery Pack CEL Cold Weather Emergency Battery Pack XAC Auxiliary AC Supply (Matches Voltage Selection) XDC Auxiliary DC Supply (6-24 Volts) Accessories LP Laser Pointer 9500 Torx® Screwdriver 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. MMEX-102214 38 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com PROJECT INFORMATION SIMPLESEAL™ Job Name Fixture Type CMEXR SERIES Catalog Number PRODUCT FEATURES: » Recessed wall mount – Single Face Approved by » Indirect Red or Green LED » Self diagnostic testing features » One-piece seam welded housing » 304 stainless steel overlapping doorframe SPECIFICATIONS HOUSING: 20-gauge CRS standard – see ordering information. Hole-free one-piece seam welded construction. White TGIC polyester powder coat finish – 5 step pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%. DOORFRAME: 20-gauge type 304 stainless steel (#4 finish-post fabrication) standard – see ordering information. One-piece 60° beveled perimeter construction. Continuous angle lens retention system. Mechanical guide for doorframe fastener alignment. Doorframe secured to housing with 4 captive flush mounted Phillips head stainless steel fasteners. DOORFRAME GASKET: One-piece closed cell extruded silicone gasket seals doorframe to housing and wall structure. LENS: .125" clear polycarbonate lens sealed to perimeter ledge of lens aperture with silicone sealant and secured with continuous lens retention system. LEGEND: Legend illuminated by internal high output LEDs. Lettering six inches high with .750" stroke. Polycarbonate red or green filter panels. High impact, punched, formed and painted sheet metal stencil and field selectable chevron inserts. ELECTRICAL: 624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Exit Ready – can power one Kenall METSS Satellite Exit. OPTIONS: Sealed nickel-cadmium Emergency Battery Pack (EL) with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected mechanical test switch and status indicator. Provides 120 minutes of emergency operation. Emergency Battery Pack (EL) suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery Pack (CEL) suitable for -45°C to 45°C (-49°F to 113°F). (When used with a Kenall METSS, this fixture provides 90 minutes of emergency operation.) PATENT: U.S. Patent No. 5, 902, 035. LISTINGS: UL and CUL Listed for Wet Location. UL certified IP65 per IEC 60598. NSF2 Splash/Non-Food Zone. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements. FED-STD-209E/Class 100 (ISO 5) Cleanrooms. LED UL 924 IP65 ISO 5 NFPA 101 Class 100 ORDERING INFORMATION (Ex: CMEXR-5F-R-DT-NT-EL) Model Frame Material Legend Color Voltage Mounting Options Accessories CMEXR Frame Material 5F 20-Ga Type 304 SS (STD) 2F 20-Ga CRS Painted White XF 20-Ga Type 316 SS Legend Color G Green R Red Mounting NT Recessed Mounting Tray for new construction; fits16" stud spacing, 5/8" wall thickness (tray is mounted before drywall installed) RT Recessed Retrofit Mounting Tray for existing construction; 10.75"×14.5" opening required Voltage DT 120/277 Volts DTC 120/347 Volts Options CEL Cold Weather Emergency Battery Pack EL Standard Emergency Battery Pack BEF Black Exit Face for 5F or XF SS Frame BLK Black Exterior CRS Frame and Exit Face XAC Auxiliary AC Supply (matches voltage selection) XDC Auxiliary DC Supply (6-24 volts) Accessory LP Laser Pointer Side View DIMENSIONAL DATA Face View 12.29" 2.62" Back View Gasket Profile Stud Spacing 16" /Rough Opening 10.75" × 14.50" Wall Thickness 5/8" 16.00" (1) 7/8" Dia. Hole Wall 10.75" Fixture Housing 14.50" (4) .31" Dia. K.O. 16.05" www.kenall.com Gasket mechanically retained P: 800-4-Kenall Lens Frame F: 262-891-9701 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. CMEXR-010214 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 39 39 PROJECT INFORMATION MILLENIUM METREX™ Job Name Fixture Type METSS SERIES Catalog Number PRODUCT FEATURES: Approved by » Surface wall mount – Single Face » Indirect Red or Green LED » Satellite Exit » High impact polycarbonate construction SPECIFICATIONS HOUSING: High impact, injection molded polycarbonate. Housing provided with four-point mounting holes, one wireway hole and temporary junction box mounting drill points – see Cross Section/ Details. Closed cell die-cut Neoprene gasket seals housing to mounting surface. SHIELD: UV-stabilized, high impact, injection molded clear polycarbonate. Nominal thickness .120". Captive stainless steel Torx® with center pin fasteners secure shield to housing. Continuous closed cell silicone gasket seals shield to housing. LEGEND: Legend illuminated by internal high output LEDs. Lettering six inches high with .750" stroke. Polycarbonate red or green filter panels. High impact, injection molded polycarbonate stencil and field selectable chevron inserts. ELECTRICAL: 624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Powered by external 4VDC power supply as provided by Kenall METDU, METSU, METSW, METSR, MMEX, CMEXR, METEC, METEL or METELHC. INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®. LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements. LED IP64 UL 924 NFPA 101 ORDERING INFORMATION (Ex: METSS-MW-R-4DVC) Model Finish Legend Color METSS Voltage Options Accessories Voltage* 4VDC 4 Volts DC Option PH Phillips Head Fasteners 4VDC Finish MB Matte Black MW Matte White Legend Color R Red G Green Accessory 9500 Torx® with center pin Screwdriver *METSS can be powered by METDU, METSU, METSW, METSR, MMEX, CMEXR, METEC, METEL, METELHC DIMENSIONAL DATA Baseplate Mounting View 2.08" 9.00" 15.20" 10.00" 6.00" (4) .312" Dia. Mounting Holes www.kenall.com P: 800-4-Kenall F: 262-891-9701 .875" Dia. Hole 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. METSS-121613 40 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com PROJECT INFORMATION MILLENIUM METREX™ Job Name Fixture Type METEC SERIES Catalog Number Approved by PRODUCT FEATURES: » Surface wall mount – Single Face » Indirect Red or Green LED » Exit/Emergency combo unit » High impact polycarbonate construction SPECIFICATIONS HOUSING: High impact, injection molded polycarbonate. Housing provided with four-point mounting holes, one wireway hole and temporary junction box mounting drill points – see Cross Section/ Details. Closed cell die-cut Neoprene gasket seals housing to mounting surface. SHIELD: UV-stabilized, high impact, injection molded clear polycarbonate. Nominal thickness .120". Captive stainless steel Torx® with center pin fasteners secure shield to housing. Continuous closed cell silicone gasket seals shield to housing. LEGEND: Legend illuminated by internal high output LEDs. Lettering six inches high with .750" stroke. Polycarbonate red or green filter panels. High impact, injection molded polycarbonate stencil and field selectable chevron inserts. ELECTRICAL: 624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable chassis. Sealed nickel-cadmium Emergency Battery Pack with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected mechanical test switch and status indicator. Suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery Pack (CL) suitable for -30°C to 45°C (-22°F to 113°F). Remote Exit Ready – can power one Kenall METSS Satellite Exits. Can also power Kenall METER Emergency Remote Unit(s); selected total lamp wattage – including all remotes – cannot exceed unit output rating; consult Output Rating chart INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®. Drill points provided for optional surface conduit entry. LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements. LED IP64 UL 924 NFPA 101 ORDERING INFORMATION (Ex: METEC-24N-MW-R-2-6.5L-120) Model Battery Capacity Finish Legend Color Lamp Qty Lamp Watt/Type Voltage Options Accessories METEC Battery Capacity 24N 24W Nickel Cadmium 40N 40W Nickel Cadmium 48Nâ—Ź 48W Nickel Cadmium 80Nâ—Ź 80W Nickel Cadmium OUTPUT RATING Battery *½ hr *1 hr 1½ hr 2 hr 24N 48W 32W 24W 18W 40N 80W 53W 40W 30W 48N 96W 64W 48W 36W 80N 160W106W 80W 60W *per Canadian code Finish MB Matte Black MW Matte White Legend Color R Red G Green Lamp Quantity 2 2 Internal Lamps 4 4 Internal Lamps 3 hr 4 hr 12W 9W 20W 15W 24W 18W 40W 30W Options CEL** Cold Weather Emergency Battery Pack PH Phillips Head Fasteners Lamp Wattage/Type* 12H 12W Halogen 20H 20W Halogen 6.5L 6.5W LED Accessories LP Laser Pointer 9500 Torx® with center pin Screwdriver Voltage 120 120 Volts DT 120/277 Volts DTC 120/347 Volts *Selected total lamp wattage cannot exceed unit output rating. Consult Output Rating Chart on left. **n/a with 80N battery capacity or DTC voltage. â—Ź n/a with 6.5W LED lamp type. DIMENSIONAL DATA 20.50" 5.96" 9.50" 14.50" 6.00" (4) .312" Dia. Mounting Holes www.kenall.com P: 800-4-Kenall F: 262-891-9701 2.00" Dia. Hole 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. METEC-112614 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 41 41 PROJECT INFORMATION MILLENIUM METREX™ Job Name Fixture Type METEL SERIES Catalog Number Approved by PRODUCT FEATURES: » Surface wall mount » Self contained emergency light » Self diagnostic testing features » High impact polycarbonate construction SPECIFICATIONS SHIELD: UV-stabilized, high impact, injection molded clear polycarbonate. Nominal thickness .120". Captive stainless steel Torx® with center pin fasteners secure shield to housing. Continuous closed cell silicone gasket seals shield to housing. HOUSING: High impact, injection molded polycarbonate. Housing provided with four-point mounting holes, one wireway hole and temporary junction box mounting drill points – see Cross Section/ Details. Closed cell die-cut Neoprene gasket seals housing to mounting surface. ELECTRICAL: Electrical components mounted to removable chassis. Sealed nickel-cadmium Emergency Battery Pack with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected mechanical test switch and status indicator. Suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery Pack (CL) suitable for -30°C to 45°C (-22°F to 113°F). Remote Exit Ready – can power one or two Kenall METSS Satellite Exits. Can also power Kenall METER Emergency Remote Unit(s); selected total lamp wattage – including all remotes – cannot exceed unit output rating; consult Output Rating chart INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®. Drill points provided for optional surface conduit entry. LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements. LED IP64 UL 924 NFPA 101 ORDERING INFORMATION (Ex: METEL-24N-MW-2-6.5L-120) Model Battery Capacity Finish Lamp Qty Lamp Wattage/Type Voltage Options Accessories METEL Battery Capacity 24N 24W Nickel Cadmium 40N 40W Nickel Cadmium Finish MB Matte Black MW Matte White OUTPUT RATING Battery *½ hr *1 hr 1½ hr 2 hr 3 hr 4 hr 24N 48W 32W 24W 18W 12W 9W 40N 80W 53W 40W 30W 20W 15W *per Canadian code Lamp Quantity 2 2 Internal Lamps 4 4 Internal Lamps (LED only – fixed optics) Lamp Wattage/Type* 12H 12W Halogen 20H 20W Halogen 6.5L 6.5W LED Voltage 120 120 Volts DT 120/277 Volts DTC 120/347 Volts Accessories LP Laser Pointer 9500 Torx® with center pin Screwdriver Options CEL** Cold Weather Emergency Battery Pack PH Phillips Head Fasteners * Selected total lamp wattage cannot exceed unit output rating. Consult Output Rating Chart on left. **n/a with 40N battery capacity or DTC voltage. DIMENSIONAL DATA Baseplate Mounting View 5.20" 6.00" 9.50" 12.00" 8.50" (4) .312" Dia. Mounting Holes www.kenall.com P: 800-4-Kenall F: 262-891-9701 2.00" Dia. Hole 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. METEL-121613 42 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com PROJECT INFORMATION MILLENIUM METREX™ Job Name Fixture Type METELHC SERIES Catalog Number Approved by PRODUCT FEATURES: » Surface mount – wall or ceiling » High capacity battery options » Self contained emergency light » Self diagnostic testing features » High impact polycarbonate construction SPECIFICATIONS HOUSING: High impact, injection molded polycarbonate. Housing provided with four-point mounting holes, one wireway hole and temporary junction box mounting drill points – see Cross Section/ Details. Closed cell die-cut Neoprene gasket seals housing to mounting surface. SHIELD: UV stabilized, high impact, injection molded clear polycarbonate. Nominal thickness .120". Captive stainless steel Torx® with center pin fasteners secure shield to housing. Continuous closed cell silicone gasket seals shield to housing. ELECTRICAL: Electrical components mounted to removable chassis. Sealed nickel-cadmium Emergency Battery Pack with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected mechanical test switch and status indicator. Suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery Pack (CEL) suitable for -30°C to 45°C (-22°F to 113°F). Remote Exit Ready – can power one or two Kenall METSS Satellite Exits. Can also power Kenall METER Emergency Remote Unit(s); selected total lamp wattage – including all remotes – cannot exceed unit output rating; consult Output Rating chart INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®. Drill points provided for optional surface conduit entry. LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements. LED IP64 UL 924 NFPA 101 ORDERING INFORMATION (Ex: METELHC-24N-MW-2-6.5L-120) Model Battery Capacity Finish Lamp Qty Lamp Type Voltage Options Accessories METELHC Battery Capacity 24N 24W Nickel Cadmium 40N 40W Nickel Cadmium 48Nâ—Ź 48W Nickel Cadmium 80Nâ—Ź 80W Nickel Cadmium Finish MB Matte Black MW Matte White OUTPUT RATING Battery *½ hr *1 hr 1½ hr 2 hr 24N 48W 32W 24W 18W 40N 80W 53W 40W 30W 48N 96W 64W 48W 36W 80N 160W106W 80W 60W *per Canadian code 3 hr 4 hr 12W 9W 20W 15W 24W 18W 40W 30W Lamp Quantity 2 2 Internal Lamps 4 4 Internal Lamps Options CEL** Cold Weather Emergency Battery Pack PH Phillips Head Fasteners Lamp Wattage/Type* 12H 12W Halogen 20H 20W Halogen 6.5L 6.5W LED Accessories LP Laser Pointer 9500 Torx® with center pin Screwdriver Voltage 120 120 Volts DT 120/277 Volts DTC 120/347 Volts * Selected total lamp wattage cannot exceed unit output rating. Consult Output Rating Chart on left. ** n/a with 80N battery capacity or DTC voltage. â—Ź n/a with 6.5W LED lamp type. DIMENSIONAL DATA 20.50" 5.96" 9.50" 14.50" 6.00" (4) .312" Dia. Mounting Holes www.kenall.com 2.00" Dia. Hole P: 800-4-Kenall F: 262-891-9701 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. METELHC-010214 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 43 43 PROJECT INFORMATION MILLENIUM METREX™ Job Name Fixture Type METER SERIES Catalog Number PRODUCT FEATURES: Approved by » Surface mount – wall or ceiling » Emergency Remote Unit » ADA compliant » 16-gauge cold rolled steel baseplate » UV-stabilized high impact clear wraparound polycarbonate lens SPECIFICATIONS LENS/HOUSING: One-piece wraparound lens/housing, UV-stabilized, high impact, virgin injection molded polycarbonate. Nominal thickness .120". BASEPLATE: 16-gauge CRS. Baseplate provided with four-point mounting holes, one wireway hole – see Cross Section/Details. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%. GASKET: Die-cut closed cell neoprene gasket seals lens/housing to mounting surface. HARDWARE: Four stainless steel Torx® with center pin fasteners secure lens/housing to baseplate. ELECTRICAL: 12V AC or DC operation. Field adjustable emergency lamps. Powered by external 12VDC power supply as provided by Kenall METEC, METEL or METELHC. INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®. LISTINGS: UL and CUL listed for Wet Location. Meets or exceeds UL924 and NFPA 101 standards. LED UL 924 NFPA 101 ADA ORDERING INFORMATION (Ex: METER-MW-2-6.5L-12VAC/DC) Model Finish Lamp Qty Lamp Type METER Voltage Options Accessories 12VAC/DC Finish MB Matte Black MW Matte White Lamp Quantity 1 1 Internal Lamp 2 2 Internal Lamps Voltage 12VAC/DC 12 Volt AC/DC Accessories 9500 Torx® Screwdriver Options PH Phillips Head Fasteners SA Die-Cast Surface Adapter (Non ADA) Lamp Wattage/Type 12H 12W Halogen 20H 20W Halogen 6.5L 6.5W LED DIMENSIONAL DATA SURFACE ADAPTER BASEPLATE MOUNTING 3.98" 3.88" 5.76" 5.94" 9.12" 6.50" 8.50" 6.44" 8.94" 6.50" 3.80" 3.81" 6.31" 5.88" (4) .281" Dia. 2.00" Dia. Hole Mounting Holes www.kenall.com P: 800-4-Kenall 3/4" IPS Tapped (4) .281" Dia. Mounting Holes F: 262-891-9701 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. METER-010214 44 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com PROJECT INFORMATION MILLENIUM™ ROUND Job Name Fixture Type MR17 SERIES – HIGH PERFORMANCE, SEMI-RECESSED Catalog Number PRODUCT FEATURES: Approved by » Semi-recessed wall mount – 17"Dia. ×4"D » Peace of Mind Guarantee® against breakage » Dust and water protected to IP64 standards » Wide path lateral throw (MR17WPSR), narrow path forward throw (MR17NPSR) » ADA compliant WP NP SPECIFICATIONS HOUSING (SERIES PP, ND): Die-cast aluminum housing with integral heat sinks. Housing interlocks and wraps around lens base producing maximum moisture deflection and resistance to prying. Standard bronze exterior TGIC polyester powder coat – 5-step pre-treatment. HOUSING (SERIES NL): 18-gauge CRS housing. Housing interlocks and wraps around lens base producing maximum moisture deflection and resistance to prying. Standard white exterior TGIC polyester powder coat – 5-step pre-treatment. REFLECTOR: Precision designed semi-specular reflector (semi-cutoff) produces an elongated lateral and shallow distribution. System produces aesthetically pleasing illumination of narrow passages at maximum fixture spacings with minimal light trespass. LENS: UV-stabilized, high impact resistant, virgin injection molded clear polycarbonate lens. The high efficiency lens is designed to enhance appearance without beam scatter. Close tolerance push/ turn/lock-in-place mating of injection molded base and lens facilitates set up and installation. Base and lens secured with one concealed captive Torx® with center pin fastener. LENS BASE: Marine grade cast aluminum. Lens base shields lamp from viewing angles. Standard black, bronze or white exterior TGIC polyester powder coat finished – 5-step pre-treatment. See Ordering Information for optional finishes. EYELID: High impact resistant, injection molded opaque black, bronze or white polycarbonate. Optional Light Gray, Silver, Forest Green or Custom Color (see Ordering Information below) are chemically bonded, impact resistant finishes. GASKETING: Closed cell, silicone “O” ring gaskets positioned in gasket channels of lens base and in Series PP, ND housing. HARDWARE: One stainless steel Torx® with center pin fastener. ELECTRICAL: HID ballasts high power factor. Metal halide lamps utilize pulse start technology. Shock absorbing, medium base lamp sockets provided for HID lamps. INSTALLATION: See Technical Data Sheets for semi-recessed installation details, mounting accessories and rough-in box availability. WARRANTY: Standard four-point mounting and polycarbonate lens required for Peace of Mind Guarantee®. LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. IP64 ADA ORDERING INFORMATION (Ex: MR17NPSR-PP-C-LG-70S-1-120) Model Mounting Lens Type Finish Lamp Type Lamp Qty C Model MR17NPSR Narrow MR17WPSR Wide Mounting Type PP Pour-in-Place or Masonry ND Non IC (Deep Profile) NL Non IC (Low Profile) Lens Type C Clear Polycarbonate Voltage Options Accessories 1 Finish MB Matte Black MW Matte White DB Dark Bronze LG Light Gray SL Silver FG Forest Green CC Custom Color (Consult factory) Lamp Type (Qty/Ballast/Volt./Starting Temp) 50M† 50 Watt MH (1/HPF/120,277,347/-20°F) 50S 50 Watt HPS (1/HPF/120,277/-40°F) 70M† 70 Watt MH (1/HPF/120,277,347/-20°F) 70S 70 Watt HPS (1/HPF/120,277,347/-40°F) 100M† 100 Watt MH (1/HPF/120,277,347/-20°F) 100S 100 Watt HPS (1/HPF/120,277,347/-40°F) Lamp Quantity 1 One Lamp Voltage 120 120 Volts 277 277 Volts 347 347 Volts www.kenall.com Options AUX20H• Low Voltage Emergency Auxiliary Lamp (12VDC) w/(2) 20W Halogen MR16 lamps supplied by Kenall (MR17WPSR only) AUX6.5L• Low Voltage Emergency Auxiliary Lamp (12VDC) w/(2) 6.5W LED MR16s supplied by Kenall (MR17WPSR only) FS Single Fuse & Holder NAT Natatorium Environment Option QR Quartz restrike system for maximum 100 Watt DC bay quartz lamp (see 9009) QRC Hot/Cold Quartz restrike QS Quartz socket only QS2 Two Quartz sockets (max. 50W ea.) (MR17WPSR only) RAK Remote Arc Keeper (100M lamp type only) XAC* Auxiliary Emergency Lighting (120V AC) Accessories 9009 100 Watt DC Bay Quartz Lamp 50QL 50 Watt Candelabra Base Quartz Lamp 9500 Torx® Screwdriver † * • P: 800-4-Kenall F: 262-891-9701 UV shielding lamp supplied Configured to accommodate two emergency quartz lamps (50W max). Lamps by others. 12VDC Power to be supplied by others. 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. MR17_NPSR_WPSR-120213 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 45 45 PROJECT INFORMATION MILLENIUM™ ROUND Job Name Fixture Type MR17 SERIES – HIGH PERFORMANCE Catalog Number PRODUCT FEATURES: Approved by » Surface wall mount – 17"Dia. ×9"D » Peace of Mind Guarantee® against breakage » Dust and water protected to IP64 standards » Wide path lateral throw (MR17WP), narrow path forward throw (MR17NP) » Optional egress optics available (MR17WP) WP NP SPECIFICATIONS HOUSING: Marine grade die-cast aluminum. Rib reinforced construction. Integral heat sinks. Housing flange interlocks and wraps around lens base producing maximum moisture deflection and resistance to prying. Housing provided with four-point mounting holes, one wireway hole and temporary junction box mounting drill points. Standard black, bronze or white exterior TGIC polyester powder coat – 5-step pre-treatment. See Ordering Information for optional finishes. REFLECTOR: Precision designed semi-specular reflector (semi-cutoff) produces an elongated lateral and shallow distribution. System produces aesthetically pleasing illumination of narrow passages at maximum fixture spacings with minimal light trespass. LENS: UV-stabilized, high impact resistant, virgin injection molded clear polycarbonate lens. The high efficiency lens is designed to enhance appearance without beam scatter. Close tolerance push/ turn/lock-in-place mating of injection molded base and lens facilitates set up and installation. Base and lens secured with one concealed captive Torx® with center pin fastener. LENS BASE/EYELID: Lens base shields lamp from viewing angles. High impact resistant, injection molded opaque black, bronze or white polycarbonate. Optional Light Gray, Silver, Forest Green or Custom Color (see Ordering Information below) are chemically bonded, impact resistant finishes. GASKETING: Die-cut, closed cell neoprene self adhesive gasket seals housing to mounting surface. Closed cell, silicone “O” ring gaskets positioned and friction secured in gasket channels of lens base and housing. HARDWARE: One stainless steel Torx® with center pin fastener. ELECTRICAL: HID ballasts high power factor. Metal halide lamps utilize pulse start technology. Shock absorbing, medium base lamp sockets provided for HID lamps. INSTALLATION: HID units cannot be inverted to be an uplight. WARRANTY: Standard four-point mounting and polycarbonate lens required for Peace of Mind Guarantee®. LISTINGS: UL listed for Wet Location. UL certified IP64 per IEC 60598. IP64 ORDERING INFORMATION (Ex: MR17NP-C-SL-150S-1-277) Model Lens Type Finish Lamp Type C Model MR17NP Narrow MR17WP Wide Lens Type C Clear Polycarbonate Finish MB Matte Black MW Matte White DB Dark Bronze LG Light Gray SL Silver FG Forest Green CC Custom Color (Consult factory) Lamp Qty Voltage Options Accessories 1 Lamp Type (Qty/Ballast/Volt./Starting Temp) 50M† 50 Watt MH (1/HPF/120,277,347/-20°F) 50S 50 Watt HPS (1/HPF/120,277/-40°F) 70M† 70 Watt MH (1/HPF/120,277,347/-20°F) 70S 70 Watt HPS (1/HPF/120,277,347/-40°F) 100M† 100 Watt MH (1/HPF/120,277,347/-20°F) 100S 100 Watt HPS (1/HPF/120,277,347/-40°F) 150M† 150 Watt MH (1/HPF/120,277,347/-20°F) 150S 150 Watt HPS (1/HPF/120,277,347/-40°F) Lamp Quantity 1 One Lamp Voltage 120 120 Volts 277 277 Volts 347â–˛ 347 Volts Options AUX20H• Low Voltage Emergency Auxiliary Lamp (12VDC) w/(2) 20W Halogen MR16 lamps supplied by Kenall (MR17WP only) AUX6.5L• Low Voltage Emergency Auxiliary Lamp (12VDC) w/(2) 6.5W LED MR16s supplied by Kenall (MR17WP only) FS Single Fuse & Holder NAT Natatorium Environment Option QR Quartz restrike system for maximum 100 Watt DC bay quartz lamp (see 9009) QRC Hot/Cold Quartz restrike QS Quartz socket only QS2 Two Quartz sockets (max. 50W ea.) (MR17WP only) RAK Remote Arc Keeper (100M lamp type only) XAC* Auxiliary Emergency Lighting (120V AC) (MR17NP only) Accessories BPC Photo Control – Shielded Button Type (120 or 277V only, 277 Volt n/a 150 HID) 9009 100 Watt DC Bay Quartz Lamp 50QL 50 Watt Candelabra Base Quartz Lamp 9500 Torx® Screwdriver † UV shielding lamp supplied * Configured to accommodate two emergency quartz lamps (50W max). Lamps by others. â–˛ n/a with BPC • 12VDC Power to be supplied by others. www.kenall.com P: 800-4-Kenall F: 262-891-9701 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. MR17_NP_WP-110813 46 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com PROJECT INFORMATION Job Name MILLENIUM FINITE™ Fixture Type FN15 SERIES – LOW PROFILE WITH EGRESS OPTICS Catalog Number PRODUCT FEATURES: Approved by » Surface wall mount – 9"H×15"W×12"D » Full cut-off for IDA-approved Dark Sky installations » High impact, UV-stabilized polycarbonate housing » UL certified IP64 per IEC 60598 » Peace of Mind Guarantee® against breakage SPECIFICATIONS HOUSING: High-impact resistant, UV-stabilized injection molded polycarbonate. Ballast housing marine-grade die-cast aluminum construction. DOOR: High-impact resistant, UV-stabilized injection molded polycarbonate with detachable hinge. Secured to housing with four (4) captive, recessed Torx® (or optional Phillips head) stainless steel screws. Lens sealed with closed-cell silicone gasket and secured to door frame with heavy gauge stainless steel brackets. GASKETING: Closed cell, silicone “O”ring gasket seals joint between polycarbonate housing and die-cast aluminum ballast housing and joint between polycarbonate housing and polycarbonate lens frame assembly. Thick gauge, die-cut, closed cell neoprene with self-adhesive gasket seals joint between housing and mounting surface or accessory surface conduit adapter. ELECTRICAL: Fluorescent electronic 120/277/347 and dual voltage ballasts high power factor (<10% THD), HID ballasts high power factor. Metal halide lamps utilize pulse start technology. Shock absorbing, medium base lamp sockets provided for HID lamps. See Lamp Type for electronic metal halide ballast option. Two (2) 12V DC emergency auxiliary lamps provided (12VDC Power to be supplied by others.) – see Egress Option in Ordering Information. INSTALLATION: Fixture is factory pre-wired and includes gasketed, 16-gauge stainless steel quick mounting plate. Once four-point mounted to wall (required for Peace of Mind Guarantee®) or accessory surface conduit adapter, allows quick mounting with hook-and-lock mechanism. Quick mounting plate bolts to wall (fasteners by other), fixture attaches to mounting plate with two (2) captive Torx (or optional Phillips head) screws, which are concealed but accessible from bottom. SURFACE CONDUIT ADAPTER (ACCESSORY): Marine-grade die-cast aluminum construction includes die-cut gaskets and two ¾" threaded connection ports. Once four-point mounted to wall (required for Peace of Mind Guarantee®) allows same quick mounting (hook-and-lock) capability as described in the Installation section above. LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. IESNA-designated full cut-off. IDA-Approved™ Dark-Sky Friendly Fixture. IP64 ORDERING INFORMATION (Ex: FN15LAUX-2-A-MB-32P-1-DV-AUX20H-FS) Model FN15LAUX Optic System 2 Optic System 2 Type II Lens Type A .250" Clear Tempered Glass Lens Type Finish Lamp Type Lamp Qty Voltage Egress Options Options Accessories A Finish MB Matte Black MW Matte White DB Dark Bronze CC Custom Color (Consult factory) Voltage 120 120 Volts 277 277 Volts DV 120-277 Volts (CFL only) 347 347 Volts Lamp Type (Type/Quantity/Ballast/Volt,/Starting Temp) 26P 26 Watt PLT (1,2/RS/120,277,347/0°F) 32P 32 Watt PLT (1,2/RS/120,277,347/0°F) 50M 50 Watt MH (1/HPF/120,277,347/-20°F) 50S 50 Watt HPS (1/HPF/120,277,347/-40°F) 70M 70 Watt MH (1/HPF/120,277,347/-20°F) 70ME 70 Watt MH (1/EB/120,277/-20°F) 70S 70 Watt HPS (1/HPF/120,277,347/-40°F) Egress Options AUX20H* Low Voltage Emergency Auxiliary Lamp (12VDC) w/(2) 20W Halogen MR16 lamps supplied by Kenall AUX6.5L* Low Voltage Emergency Auxiliary Lamp (12VDC) w/(2) 6.5W LED MR16s supplied by Kenall Lamp Quantity 1 One Lamp 2 Two Lamps (CFL only) www.kenall.com P: 800-4-Kenall *12VDC Power to be supplied by others. Options FS Single Fuse & Holder PH Phillips Head Fasteners Accessory SA Die-Cast Surface Adapter F: 262-891-9701 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. FN15LAUX-100913 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 47 47 PROJECT INFORMATION Job Name MILLENIUM FINITE™ Fixture Type FN SERIES – DEEP PROFILE WITH EGRESS OPTICS Catalog Number Approved by PRODUCT FEATURES: » Surface wall mount – 15"W×9"H×13"D » Full cut-off for IDA-approved Dark Sky installations » High impact, UV-stabilized polycarbonate housing » UL certified IP64 per IEC 60598 » Peace of Mind Guarantee® against breakage SPECIFICATIONS HOUSING: High-impact resistant, UV-stabilized injection molded polycarbonate. Ballast housing marine-grade die-cast aluminum construction. DOOR: High-impact resistant, UV-stabilized injection molded polycarbonate with detachable hinge. Secured to housing with four (4) captive, recessed Torx® with center pin (or optional Phillips head) stainless steel screws. Lens sealed with closed-cell silicone gasket and secured to door frame with heavy gauge stainless steel brackets. GASKETING: Closed cell, silicone “O”ring gasket seals joint between polycarbonate housing and die-cast aluminum ballast housing and joint between polycarbonate housing and polycarbonate lens frame assembly. Thick gauge, die-cut, closed cell neoprene with self-adhesive gasket seals joint between housing and mounting surface or accessory surface conduit adapter. ELECTRICAL: Fluorescent electronic 120/277/347 and dual voltage ballasts high power factor (<10% THD), HID ballasts high power factor. Metal halide lamps utilize pulse start technology. Shock absorbing, medium base lamp sockets provided for HID lamps. Two (2) 12V DC emergency auxiliary lamps provided (12VDC Power to be supplied by others.) – see Egress Option in Ordering Information. INSTALLATION: Fixture is factory pre-wired and includes gasketed, 16-gauge stainless steel quick mounting plate. Once four-point mounted to wall (required for Peace of Mind Guarantee®) or accessory surface conduit adapter, allows quick mounting with hook-and-lock mechanism. Quick mounting plate bolts to wall (fasteners by other), fixture attaches to mounting plate with two (2) captive Torx® with center pin (or optional Phillips head) screws, which are concealed but accessible from bottom. SURFACE CONDUIT ADAPTER (ACCESSORY): Marine-grade die-cast aluminum construction includes die-cut gaskets and two ¾" threaded connection ports. Once four-point mounted to wall (required for Peace of Mind Guarantee®) allows same quick mounting (hook-and-lock) capability as described in the Installation section above. LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. IESNA-designated full cut-off. IDA-Approved™ Dark-Sky Friendly Fixture. IP64 ORDERING INFORMATION (Ex: FN15DAUX-2-A-MB-32P-1-DV) Model FN15DAUX Optic System Lens Type 2 A Optic System 2 Type II Lens Type A .250" Clear Tempered Glass Finish Lamp Type Lamp Qty Finish MB Matte Black MW Matte White DB Dark Bronze CC Custom Color Consult factory) Lamp (Type/Qty/Ballast/Volt./Starting Temp) 26P 26 Watt PLT (1,2/RS/120,277,347/0°F) 32P 32 Watt PLT (1,2/RS/120,277,347/0°F) 100M 100 Watt MH (1/HPF/120,277,347/-20°F) 100ME 100 Watt MH (1/EB/120,277/-20°F) 100S 100 Watt HPS (1/HPF/120,277,347/-40°F) 150M 150 Watt MH (1/CWA/120,277,347/-20°F) 150S 150 Watt HPS (1/HPF/120,277,347/-40°F) Voltage Options Accessories Voltage 120 120 Volts 277 277 Volts DV 120-277 Volts (CFL only) 347 347 Volts Options AUX20H* Low Voltage Emergency Auxiliary Lamp (12VDC) w/(2) 20W Halogen MR16 lamps supplied by Kenall AUX6.5L* Low Voltage Emergency Auxiliary Lamp (12VDC) w/(2) 6.5W LED MR16s supplied by Kenall FS Single Fuse & Holder PH Phillips Head Fastener *12VDC Power to be supplied by others. Accessory SA Die-Cast Surface Adapter Lamp Quantity 1 One Lamp 2 Two Lamps (CFL only) www.kenall.com P: 800-4-Kenall F: 262-891-9701 10200 55th Street Kenosha, Wisconsin 53144 When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved. FN15DAUX-100913 48 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com NFPA Life Safety Code Excerpt: Illumination of Means of Egress 7.8 Illumination of Means of Egress. 7.8.1 General. 7.8.1.1* Illumination of means of egress shall be provided in accordance with Section 7.8 for every building and structure where required in Chapters 11 through 43. For the purposes of this requirement, exit access shall include only designated stairs, aisles, corridors, ramps, escalators, and passageways leading to an exit. For the purposes of this requirement, exit discharge shall include only designated stairs, aisles, corridors, ramps, escalators, walkways, and exit passageways leading to a public way. 7.8.1.2 Illumination of means of egress shall be continuous during the time that the conditions of occupancy require that the means of egress be available for use, unless otherwise provided in 7.8.1.2.2. 7.8.1.2.1 Artificial lighting shall be employed at such locations and for such periods of time as are necessary to maintain the illumination to the minimum criteria values herein specified. 7.8.1.2.2 Automatic, motion sensor–type lighting switches shall be permitted within the means of egress, provided that the switch controllers are equipped for fail-safe operation, the illumination timers are set for a minimum 15-minute duration, and the motion sensor is activated by any 7.8.1.3* The floors and other walking surfaces within an exit and within the portions of the exit access and exit discharge designated in 7.8.1.1 shall be illuminated as follows: Life Safety Code® and 101® are registered trademarks of the National Fire Protection Association, Quincy, MA. (b) The standby generator shall be permitted to be used for the stair shaft and vestibule emergency lighting power supply. (6) New access-controlled egress doors in accordance with 7.2.1.6.2. 7.9.1.2 For the purposes of 7.9.1.1, exit access shall include only designated stairs, aisles, corridors, ramps, escalators, and passageways leading to an exit. For the purposes of 7.9.1.1, exit discharge shall include only designated stairs, ramps, aisles, walkways, and escalators leading to a public way. 7.9.1.3 Where maintenance of illumination depends on changing from one energy source to another, a delay of not more than 10 seconds shall be permitted. 7.9.2 Performance of System. 7.9.2.1* Emergency illumination shall be provided for a minimum of 11⁄2 hours in the event of failure of normal lighting. Emergency lighting facilities shall be arranged to provide initial illumination that is not less than an average of 1 footcandle (10.8 lux) and, at any point, not less than 0.1 footcandle (1.1 lux), measured along the path of egress at floor level. Illumination levels shall be permitted to decline to not less than an average of 0.6 footcandle (6.5 lux) and, at any point, not less than 0.06 footcandle (0.65 lux) at the end of 11⁄2 hours. A maximum-to-minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (1) During conditions of stair use, the minimum illumination for new stairs shall be at least 10 footcandle (108 lux), measured at the walking surfaces. 7.9.2.2 New emergency power systems for emergency lighting shall be at least Type 10, Class 1.5, Level 1, in accordance with NFPA110, Standard for Emergency and Standby Power Systems. (2) The minimum illumination for floors and walking surfaces, other than new stairs during conditions of stair use, shall be to values of at least 1 footcandle (10.8 lux), measured at the floor. 7.9.2.3* The emergency lighting system shall be arranged to provide the required illumination automatically in the event of any interruption of normal lighting due to any of the following: (3) In assembly occupancies, the illumination of the walking surfaces of exit access shall be at least 0.2 footcandle (2.2 lux) during periods of performances or projections involving directed light. (4)*The minimum illumination requirements shall not apply where operations or processes require low lighting levels. 7.8.1.4* Required illumination shall be arranged so that the failure of any single lighting unit does not result in an illumination level of less than 0.2 footcandle (2.2 lux) in any designated area. 7.8.1.5 The equipment or units installed to meet the requirements of Section 7.10 also shall be permitted to serve the function of illumination of means of egress, provided that all requirements of Section 7.8 for such illumination are met. 7.8.2 Sources of Illumination. 7.8.2.1* Illumination of means of egress shall be from a source considered reliable by the authority having jurisdiction. 7.8.2.2 Battery-operated electric lights and other types of portable lamps or lanterns shall not be used for primary illumination of means of egress. Battery-operated electric lights shall be permitted to be used as an emergency source to the extent permitted under Sec, 7.9. 7.9 Emergency Lighting. 7.9.1 General. 7.9.1.1* Emergency lighting facilities for means of egress shall be provided in accordance with Section 7.9 for the following: (1) Buildings or structures where required in Chapters 11–43 (2) Underground and limited access structures as addressed in Section 11.7 (3) High-rise buildings as required by other sections of this Code (4) Doors equipped with delayed-egress locks (5) Stair shaft and vestibule of smokeproof enclosures, for which the following also apply: (a) The stair shaft and vestibule shall be permitted to include a standby generator that is installed for the smokeproof enclosure mechanical ventilation equipment. (1) Failure of a public utility or other outside electrical power supply (2) Opening of a circuit breaker or fuse (3) Manual act(s), including accidental opening of a switch controlling normal lighting facilities 7.9.2.4 Emergency generators providing power to emergency lighting systems shall be installed, tested, and maintained in accordance with NFPA 110, Standard for Emergency and Standby Power Systems. Stored electrical energy systems, where required in this Code, other than battery systems for emergency luminaires in accordance with 7.9.2.5, shall be installed and tested in accordance with NFPA 111, Standard on Stored Electrical Energy Emergency and Standby Power Systems. 7.9.2.5 Unit equipment and battery systems for emergency luminaires shall be listed to ANSI/UL 924, Standard for Emergency Lighting and Power Equipment. 7.9.2.6* Existing battery-operated emergency lights shall use only reliable types of rechargeable batteries provided with suitable facilities for maintaining them in properly charged condition. Batteries used in such lights or units shall be approved for their intended use and shall comply with NFPA 70, National Electrical Code. 7.9.2.7 The emergency lighting system shall be either continuously in operation or shall be capable of repeated automatic operation without manual intervention. 7.9.3 Periodic Testing of Emergency Lighting Equipment. 7.9.3.1 Required emergency lighting systems shall be tested in accordance with one of the three options offered by 7.9.3.1.1, 7.9.3.1.2, or 7.9.3.1.3. 7.9.3.1.1 Testing of required emergency lighting systems shall be permitted to be conducted as follows: (1) Functional testing shall be conducted monthly with a minimum of 3 weeks and a maximum of 5 weeks between tests, for not less than 30 seconds, except as otherwise permitted by 7.9.3.1.1(2). 101–76 LIFE SAFETY CODE (2)*The test interval shall be permitted to be extended beyond 30 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 49 49 NFPA Life Safety Code Excerpt: Illumination of Means of Egress days with the approval of the authority having jurisdiction. 7.10.1.5 Exit Access. (3) Functional testing shall be conducted annually for a minimum of 11⁄2 hours if the emergency lighting system is battery powered. 7.10.1.5.1 Access to exits shall be marked by approved, readily visible signs in all cases where the exit or way to reach the exit is not readily apparent to the occupants. (4) The emergency lighting equipment shall be fully operational for the duration of the tests required by 7.9.3.1.1(1) and (3). (5) Written records of visual inspections and tests shall be kept by the owner for inspection by the authority having jurisdiction. 7.9.3.1.2 Testing of required emergency lighting systems shall be permitted to be conducted as follows: (1) Self-testing/self-diagnostic battery-operated emergency lighting equipment shall be provided. (2) Not less than once every 30 days, self-testing/self-diagnostic battery-operated emergency lighting equipment shall automatically perform a test with a duration of a minimum of 30 seconds and a diagnostic routine. (3) Self-testing/self-diagnostic battery-operated emergency lighting equipment shall indicate failures by a status indicator. (4) A visual inspection shall be performed at intervals not exceeding 30 days. (5) Functional testing shall be conducted annually for a minimum of 11⁄2 hours. (6) Self-testing/self-diagnostic battery-operated emergency lighting equipment shall be fully operational for the duration of the 11⁄2 hour test. (7) Written records of visual inspections and tests shall be kept by the owner for inspection by the authority having jurisdiction. 7.9.3.1.3 Testing of required emergency lighting systems shall be permitted to be conducted as follows: (1) Computer-based, self-testing/self-diagnostic battery operated emergency lighting equipment shall be provided. (2) Not less than once every 30 days, emergency lighting equipment shall automatically perform a test with a duration of a minimum of 30 seconds and a diagnostic routine. (3) The emergency lighting equipment shall automatically perform annually a test for a minimum of 11⁄2 hours. (4) The emergency lighting equipment shall be fully operational for the duration of the tests required by 7.9.3.1.3(2) and (3). (5) The computer-based system shall be capable of providing a report of the history of tests and failures at all times. 7.10 Marking of Means of Egress. 7.10.1 General. 7.10.1.1 Where Required. Means of egress shall be marked in accordance with Section 7.10 where required in Chapters 11 through 43. 7.10.1.2 Exits. 7.10.1.2.1* Exits, other than main exterior exit doors that obviously and clearly are identifiable as exits, shall be marked by an approved sign that is readily visible from any direction of exit access. 7.10.1.2.2* Horizontal components of the egress path within an exit enclosure shall be marked by approved exit or directional exit signs where the continuation of the egress path is not obvious. 7.10.1.3 Exit Door Tactile Signage. Tactile signage shall be provided to meet the following criteria, unless otherwise provided in 7.10.1.4: (1) Tactile signage shall be located at each exit door requiring an exit sign. (2) Tactile signage shall read as follows: EXIT. (3) Tactile signage shall comply with ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities. 7.10.1.4 Existing Exemption. The requirements of 7.10.1.3 shall not apply to existing buildings, provided that the occupancy classification does not change. 50 7.10.1.5.2* New sign placement shall be such that no point in an exit access corridor is in excess of the rated viewing distance or 100 ft (30 m), whichever is less, from the nearest sign. 7.10.1.6* Floor Proximity Exit Signs. Where floor proximity exit signs are required in Chapters 11 through 43, such signs shall comply with 7.10.3, 7.10.4, 7.10.5, and 7.10.6 for externally illuminated signs and 7.10.7 for internally illuminated signs. Such signs shall be located near the floor level in addition to those signs required for doors or corridors. The bottom of the sign shall be not less than 6 in. (150mm), but not more than 18 in. (455 mm), above the floor. For exit doors, the sign shall be mounted on the door or adjacent to the door, with the nearest edge of the sign within 4 in. (100 mm) of the door frame. 7.10.1.7* Floor Proximity Egress Path Marking. Where floor proximity egress path marking is required in Chapters 11 through 43, an approved floor proximity egress path marking system that is internally illuminated shall be installed within 18 in. (455 mm) of the floor. Floor proximity egress path marking systems shall be listed in accordance with ANSI/UL 1994, Standard for Luminous Egress Path Marking Systems. The system shall provide a visible delineation of the path of travel along the designated exit access and shall be essentially continuous, except as interrupted by doorways, hallways, corridors, or other such architectural features. The system shall operate continuously or at any time the building fire alarm system is activated. The activation, duration, and continuity of operation of the system shall be in accordance with 7.9.2. The system shall be maintained in accordance with the product manufacturing listing. 7.10.1.8* Visibility. Every sign required in Section 7.10 shall be located and of such size, distinctive color, and design that it is readily visible and shall provide contrast with decorations, interior finish, or other signs. No decorations, furnishings, or equipment that impairs visibility of a sign shall be permitted. No brightly illuminated sign (for other than exit purposes), display, or object in or near the line of vision of the required exit sign that could detract attention from the exit sign shall be permitted. 7.10.1.9 Mounting Location. The bottom of new egress markings shall be located at a vertical distance of not more than 6 ft. 8 in. (2030 mm) above the top edge of the egress opening intended for designation by that marking. Egress markings shall be located at a horizontal distance of not more than the required width of the egress opening, as measured from the edge of the egress opening intended for designation by that marking to the nearest edge of the marking. 7.10.2 Directional Signs. 7.10.2.1* A sign complying with 7.10.3 with a directional indicator showing the direction of travel shall be placed in every location where the direction of travel to reach the nearest exit is not apparent. 7.10.2.2 Directional exit signs shall be provided within horizontal components of the egress path within exit enclosures as required by 7.10.1.2.2. 7.10.3* Sign Legend. 7.10.3.1 Signs required by 7.10.1 and 7.10.2 shall read as follows in plainly legible letters, or other appropriate wording shall be used: EXIT 7.10.3.2* Where approved by the authority having jurisdiction, pictograms in compliance with NFPA 170, Standard for Fire Safety and Emergency Symbols, shall be permitted. 7.10.4* Power Source. Where emergency lighting facilities are required by the applicable provisions of Chapters 11 through 43 for individual occupancies, the signs, other than approved self-luminous signs and listed photoluminescent signs in accordance with 7.10.7.2, shall be illuminated by the emergency lighting facilities. The level of illumination of the signs shall be in accordance with 7.10.6.3 or 7.10.7 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com NFPA Life Safety Code Excerpt: Illumination of Means of Egress for the required emergency lighting duration as specified in 7.9.2.1. However, the level of illumination shall be permitted to decline to 60 percent at the end of the emergency lighting duration. 7.10.7.1 Listing. Internally illuminated signs shall be listed in accordance with ANSI/UL 924, Standard for Emergency Lighting and Power Equipment, unless they meet one of the following criteria: 7.10.5 Illumination of Signs. (1) They are approved existing signs. 7.10.5.1* General. Every sign required by 7.10.1.2, 7.10.1.5, or (2) They are existing signs having the required wording in legible letters not less than 4 in. (100 mm) high. 7.10.8.1, other than where operations or processes require low lighting levels, shall be suitably illuminated by a reliable light source. Externally and internally illuminated signs shall be legible in both the normal and emergency lighting mode. 7.10.5.2* Continuous Illumination. 7.10.5.2.1 Every sign required to be illuminated by 7.10.6.3, 7.10.7, and 7.10.8.1 shall be continuously illuminated as required under the provisions of Section 7.8, unless otherwise provided in 7.10.5.2.2. 7.10.5.2.2* Illumination for signs shall be permitted to flash on and off upon activation of the fire alarm system. 7.10.6 Externally Illuminated Signs. 7.10.6.1* Size of Signs. 7.10.6.1.1 Externally illuminated signs required by 7.10.1 and 7.10.2, other than approved existing signs, unless otherwise provided in 7.10.6.1.2, shall read EXIT or shall use other appropriate wording in plainly legible letters sized as follows: (1) For new signs, the letters shall be not less than 6 in. (150 mm) high, with the principal strokes of letters not less than 3⁄4 in. (19 mm) wide. (2) For existing signs, the required wording shall be permitted to be in plainly legible letters not less than 4 in. (100 mm) high. (3) The word EXIT shall be in letters of a width not less than 2 in. (51 mm), except the letter I, and the minimum spacing between letters shall be not less than 3⁄8 in. (9.5 mm). (4) Sign legend elements larger than the minimum established in 7.10.6.1.1(1) through (3) shall use letter widths, strokes, and spacing in proportion to their height. 7.10.6.1.2 The requirements of 7.10.6.1.1 shall not apply to marking required by 7.10.1.3 and 7.10.1.7. 7.10.6.2* Size and Location of Directional Indicator. 7.10.6.2.1 Directional indicators, unless otherwise provided in 7.10.6.2.2, shall comply with the following: (3) They are signs that are in accordance with 7.10.1.3 and 7.10.1.6. 7.10.7.2* Photoluminescent Signs. The face of a photoluminescent sign shall be continually illuminated while the building is occupied. The illumination levels on the face of the photoluminescent sign shall be in accordance with its listing. The charging illumination shall be a reliable light source, as determined by the authority having jurisdiction. The charging light source, shall be of a type specified in the product markings. 7.10.8 Special Signs. 7.10.8.1 Sign Illumination. 7.10.8.1.1 Where required by other provisions of this Code, special signs shall be illuminated in accordance with 7.10.5, 7.10.6.3, and 7.10.7. 7.10.8.1.2 Where emergency lighting facilities are required by the applicable provisions of Chapters 11 through 43, the required illumination of special signs shall additionally be provided under emergency lighting conditions. 7.10.8.2 Characters. Special signs, where required by other provisions of this Code, shall comply with the visual character requirements of ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities. 7.10.8.3* No Exit. 7.10.8.3.1 Any door, passage, or stairway that is neither an exit nor a way of exit access and that is located or arranged so that it is likely to be mistaken for an exit shall be identified by a sign that reads as follows: NO EXIT 7.10.8.3.2 The NO EXIT sign shall have the word NO in letters 2 in. (51 mm) high, with a stroke width of 3⁄8 in. (9.5 mm), and the word EXIT in letters 1 in. (25 mm) high, with the word EXIT below the word NO, unless such sign is an approved existing sign. (1) The directional indicator shall be located outside of the EXIT legend, not less than 3⁄8 in. (9.5 mm) from any letter. 7.10.8.4 Elevator Signs. Elevators that are a part of a means of egress (see 7.2.13.1) shall have the following signs with a minimum letter height of 5⁄8 in. (16 mm) posted in every elevator lobby: (2) The directional indicator shall be of a chevron type, as shown in Figure 7.10.6.2.1. (1)*Signs that indicate that the elevator can be used for egress, including any restrictions on use (3) The directional indicator shall be identifiable as a directional indicator at a distance of 40 ft (12 m). (2)*Signs that indicate the operational status of elevators (4) A directional indicator larger than the minimum established for compliance with 7.10.6.2.1(3) shall be proportionately increased in height, width, and stroke. (5) The directional indicator shall be located at the end of the sign for the direction indicated. 7.10.8.5* Evacuation Diagram. Where a posted floor evacuation diagram is required in Chapters 11 through 43, floor evacuation diagrams reflecting the actual floor arrangement and exit locations shall be posted and oriented in a location and manner acceptable to the authority having jurisdiction. 7.10.9 Testing and Maintenance. 7.10.9.1 Inspection. Exit signs shall be visually inspected for operation of the illumination sources at intervals not to exceed 30 days or shall be periodically monitored in accordance with 7.9.3.1.3. FIGURE 7.10.6.2.1 Chevron-Type Indicator 7.10.6.2.2 The requirements of 7.10.6.2.1 shall not apply to approved existing signs. 7.10.6.3* Level of Illumination. Externally illuminated signs shall be illuminated by not less than 5 footcandles (54 lux) at the illuminated surface and shall have a contrast ratio of not less than 0.5. 7.10.9.2 Testing. Exit signs connected to, or provided with, a battery-operated emergency illumination source, where required in 7.10.4, shall be tested and maintained in accordance with 7.9.3. Reprinted with permission from NFPA 101®, The Life Safety Code®, copyright © 2008, National Fire Protection Association. This reprinted material is not the complete and official position of the NFPA on the referenced subject which is represented solely b the standard in its entirety. 7.10.7 Internally Illuminated Signs. 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 51 51 TECHNICAL SPECIFICATIONS Remote Lamp Voltage Drop Table Refer to the data below to specify wire size appropriate for the distance of run needed for your project. Wire Size Total watts #12 #10 #8 #6 #4 on wire run Length of Wire Run (Feet) 9 236 376600 9251516 18 118 188300 476 758 20 106 169270 429 683 24 89 141225 357 569 27 78 125200 317 505 36 5994 150238379 40 5384 135214341 45 4775 120190303 48 4470 112178284 Constant 2137 3397 5403 8590 13660 12 Volt System Maximum Voltage Drop 5% To determine the maximum length of a wire run not listed, divide the constant listed at the bottom of each column by the value of load in watts. Example: The maximum wire run for #12 wire with a 117 watt load is 2137/117=18 feet. To determine the maximum load on a wire run known length, divide the constant listed at the bottom of each column by the length of the run in feet. Example: The maximum load for a 36 foot run of #10 wire is 3397/36=94 watts. Multipliers for Equally Sized, Equally spaced Loads Number of luminaires 2 3 Multiply distance by 1.33 1.50 4 5 1.60 1.67 6 1.71 Maximum Voltage Drop 5% Remote Exit Voltage Drop Table Refer to the data below to specify wire size appropriate for the distance of run needed for your project. Wire Size #18 #16 #14 #12 #10 #8 Length of Wire Run (Feet) 1 sign on wire run89141227 361574914 2 signs on wire run44 70 113 180 287 457 EMERGENCY BATTERY PACK SELECTION GUIDE This guide provides the ordering designation for each of the standard battery packs used in Kenall luminaires. T8 Lamps EL Standard Emergency Battery pack (500-600 lumens) PELHigh Lumen Emergency Battery pack (1350 lumens) SEL Specified Emergency Battery pack RELRemote-ready Emergency Battery pack ( ** ) T5 and T5HO Lamps EL Standard Emergency Battery pack (700 lumens) PELHigh Lumen Emergency Battery pack (1250 lumens) SEL Specified Emergency Battery pack RELRemote-ready Emergency Battery pack ( ** ) Hazardous Locations for T8, T5 and T5HO Lamps HEL Standard Emergency Battery pack (300-700 lumens) Compact Fluorescent Lamps EL Standard Emergency Battery pack (300-750 lumens) SEL Specified Emergency Battery pack RELRemote-ready Emergency Battery pack ( ** ) (**consult factory) Note: Two-lamp redundancy mode requires two one-lamp ballasts combined with two-lamp emergency battery backup. In cases where there is not enough room in the luminaire to house all components, remote battery backup is necessary. Consult factory for remote battery backups which require special wiring and installation instructions per application. Lumen Chart for Compact Fluorescent Lamps (Initial Lumens for 4-Pin Lamps) Lumens Lamp Prefix One-LampTwo -Lamps PL13 350425 PL18 300525 PL26 450725 PLT26 450725 PLT32 575750 PLT42 750 n/a Note: All emergency battery packs for T8, T5, and T5HO lamps will be wired to one-lamp unless otherwise specified. 4 Volt System Maximum Voltage Drop 5% Battery Output Rating The information below illustrates the duration available with each battery and lamp wattage option. Battery *1/2 hr. *1 hr. 1 1/2 hr. 2 hrs. 3 hrs. 4 hrs. 24N 48W 32W 24W18W12W9W 40N 80W 53W 40W30W20W 15W 48N 96W 64W 48W36W24W 18W 80N 160W106W 80W60W40W 30W *per Canadian code 52 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com K230 performance PERFORMANCE standards STANDARD K230 for Luminaire Leakage in Pressurized Environments Large numbers of R&D, high-tech manufacturing and medical facilities contain areas in which environmental isolation and the prevention of cross-contamination are critical. Applications such as cleanrooms, research labs and surgical suites must be kept free of external contaminants while others, such as infectious disease isolation areas and R&D bio-containment spaces, must prevent contaminants from escaping. The need for environmental isolation in these areas is so critical that air pressure is used as a buffer against contamination. Positive pressure is employed where the introduction of foreign matter causes contamination, while negative pressure creates a barrier to contaminant egress where containment is the critical issue. When anything – including a lighting fixture – penetrates the ceiling, it creates the potential for contaminant leakage. Consequently, luminaires must be free of openings through which contaminants can pass or that could result in a reduction of pressure. Simply put, a key performance requirement for lighting fixtures in pressurized environments is the ability to prevent leakage. Testing by a qualified laboratory, utilizing the K230 testing protocol, is the best way available to ensure compliance levels comparable to those required by the NSF49 standard, Section 6.2, because K230 procedures are based on those prescribed by NSF49 for biosafety cabinetry. Thus, Kenall’s K230 determines a fixture’s ability to restrict the passage or penetration of contaminants when subjected to prescribed pressure level in either positive or negative pressure environments. In short, it measures a fixture’s resistance to leakage in virtually any pressurized environment. Kenall’s K230 test, performed under controlled conditions by a highly qualified independent testing lab, calls for a special airtight chamber containing a pressure plenum fabricated to simulate the type of ceiling surface to which the fixture will be mounted. The plenum is then pressurized to the prescribed level and sealed, with pressure readings recorded on a water gauge at five minute intervals. To meet the K230 leakage prevention standard, the fixture must be able to maintain two inches of pressure, plus or minus 10 percent, for 30 minutes. Leakage Prevention Responding to the growing needs for increasingly more effective techniques of containing dangerous organisms, standards for bio-containment cabinets have rapidly advanced in recent years. These cabinets employ negatively pressurized interiors to maximize containment. To this end, they must be free of holes, gaps, or other openings that could allow leakage and thereby compromise the effectiveness of the cabinet’s pressure-based contamination barrier. From this perspective, lighting fixtures used in larger negative pressure environments to seal off ceiling enclosures have leakagebased performance requirements very similar to those of bio-containment cabinets. There is no mandatory U.S. standard specific to luminaire leakage in pressurized applications. However, there is a widely accepted leakage standard for cabinetry developed by the National Sanitation Foundation (NSF) in conjunction with the American National Standards Institute (ANSI): NSF49 Class II (laminar flow) Biosafety Cabinetry. Section 6.2 of that standard, Pressure Decay/Soap Bubble/Tracer Gas Leak can be effectively adapted to the testing of light fixtures. Kenall refers to its proprietary adaptation as the K230 Performance Standard for Luminaire Leakage in Pressurized Environments. LIGHT FIXTURE PLENUM Pressure Tested Gauge Pressure in Fabricated plenum designed to test Kenall luminiares for pressured leaks. Hospitals Hospitals and other healthcare facilities contain areas where patients infected with or tested for highly contagious or communicable diseases, are isolated for observation and treatment. They contain a variety of areas, including surgical suites, patient rooms and ICUs, that use positive pressure as a barrier against contaminant ingress, particularly dangerous pathogens. Fixtures complying with Kenall’s K230 pressure testing standard are able to meet or exceed the leakage prevention requirements for these applications – for both contaminant ingress and the maintenance of target pressure levels. Cleanroom spaces are defined by their level of cleanliness, so these spaces require lighting fixtures capable of supporting the highest levels of environmental integrity related to the passage or production of airborne particles. Only by selecting a fixture that has been tested to accepted standards, can the specifier be confident that the fixture is free of gaps or holes through which contaminants can enter a controlled space, and does not itself produce objectionable levels of particulate contamination. K230 When you see this symbol you'll know the Kenall luminaire has been tested and certified to the K230 standard www. kenall.com P: 800-4-Kenall F: 847-360-1781 1020 Lakeside Drive Gurnee, Illinois 60031 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com 53 53 NSF NATIONAL SANITATION FOUNDATION Fixtures for use in Food Processing, Handling & Preparation NATIONAL SANITATION FOUNDATION and IP LISTINGS Kenall lighting fixtures for use in food processing, handling and Food Zones The higher le Zone/Non-Fo located in fo NSF2 in contact w NSF NATIONALSANITATION SANITATIONFOUNDATION FOUNDATIONThe purpose of criteria C2 is to insure that equipment located in a NSF NATIONAL sheet metal Luminaires for use in Food Processing, Handling & Preparation aluminum. P food storage, handling, or preparation area will not compromise the Title 21 to b requirements Fixtures Food (FN) Fixturesfor foruse useininFood FoodProcessing, Processing,Handling Handling&&Preparation Preparation sanitation FoodZones Zones (FN) for those areas. Equipment listed to criteria steel and rem C2 has been evaluated as to its corrosion resistance, cleanability and The higher level ofofconstruction isisour FNFNtype construction for Food Kenall Kenalllighting lightingfixtures fixturesfor foruse useininfood foodprocessing, processing,handling handlingand and The higher level construction our type construction for Food and the oute exposed material. Zone/Non-Food preparation preparationareas areashave havebeen beeninvestigated investigatedand andlisted listedbybythe theNational National Zone/Non-FoodContact. Contact.Fixtures Fixturesininthis thiscategory categoryare arephysically physically polycarbona cally,inin exposed materials and shall withstand normal the located food but dodonot come Sanitation SanitationFoundation Foundation(NSF) (NSF)asasconforming conformingtotothe therequirements requirementsinin Specifi located foodpreparation preparation andhandling handlingareas areas butwear, not come Kenall canno corrosive action ofthe foods, beverages, and conditions. cleaning compounds, inincontact with under AllAllexposed their theircriteria criteriaC2. C2. contact with thefood food undernormal normal conditions. exposed your specific and the material itself shall not impart an odor, color, taste or toxic sheet metal will be painted CRS, painted aluminum, or anodized sheet metal will be painted CRS, painted aluminum, or anodized The Thepurpose purposeofofcriteria criteriaC2 C2isistotoinsure insurethat thatequipment equipmentlocated locatedinina a material inspector. to any food that would come in contact with it. aluminum. aluminum.Paint Paintmust mustmeet meetU.S. U.S.Code CodeofofFederal FederalRegulations, Regulations, food foodstorage, storage,handling, handling,ororpreparation preparationarea areawill willnot notcompromise compromisethe the Title 21 to be used in this application. Fasteners will be stainless NSF defines the surfaces of equipment as Food Titlethis 21 category, to be used in this application. Fasteners will be stainless sanitation sanitationrequirements requirementsfor forthose thoseareas. areas.Equipment Equipmentlisted listedtotocriteria criteria Within steel removable without the (thumbscrew or Non-Food Contact surfaces. Food Contact surfacestype) are steeland and removable without theuse useof ofa atool tool (thumbscrew type) C2 C2has hasbeen beenevaluated evaluatedasastotoitsitscorrosion corrosionresistance, resistance,cleanability cleanabilityand and Contact and the outer exposed lens must bebeanan FDA approved Food Grade further divided into areas as Food Zone, Splash Zone, and Non-Food and the outer exposed lens must FDA approved Food Grade exposed material. exposed material. polycarbonate material. Zone, with Food Zone requirements being the most stringent and polycarbonate material. Specifi cally, exposed materials shall withstand normal wear, the Specifically, exposed materials shall withstand normal wear, the Non-Food Zone being the least stringent. Aofconstruction subcategory ofissuitable Food Kenall recommend which level Kenallcannot cannot recommend which levelof constructionis suitablefor for corrosive corrosiveaction actionofoffoods, foods,beverages, beverages,and andcleaning cleaningcompounds, compounds, Zone equipment is Non-Contact, i.e. equipment in the Food Zone, your specifi c capplication asasthe final decision will rest with the your specifi application the fi nal decision will rest with thelocal local and the material itself shall not impart an odor, color, taste or toxic and the material itself shall not impart an odor, color, taste or toxic but not normally in contact with the food. inspector. inspector. material materialtotoany anyfood foodthat thatwould wouldcome comeinincontact contactwith withit.it. preparation areas have been investigated and listed by the National Sanitation Foundation (NSF) as conforming to the requirements in their criteria C2. Within nes Withinthis thiscategory, category,NSF NSFdefi defi nesthe thesurfaces surfacesofofequipment equipmentasasFood Food Contact ContactororNon-Food Non-FoodContact Contactsurfaces. surfaces.Food FoodContact Contactsurfaces surfacesare are Splash Zones (SN) further furtherdivided dividedinto intoareas areasasasFood FoodZone, Zone,Splash SplashZone, Zone,and andNon-Food Non-Food Kenall has two levels of fixture construction depending on the area Zone, Zone,with withFood FoodZone Zonerequirements requirementsbeing beingthe themost moststringent stringentand and where the fixtures are being installed. Non-Food Non-FoodZone Zonebeing beingthe theleast leaststringent. stringent.AAsubcategory subcategoryofofFood Food Our SN type construction is listed for use in Splash Zones and Non Zone Zoneequipment equipmentisisNon-Contact, Non-Contact,i.e. i.e.equipment equipmentininthe theFood FoodZone, Zone, Food Zones. All exposed sheet metal will be painted CRS, painted but butnot notnormally normallyinincontact contactwith withthe thefood. food. aluminum, or anodized aluminum. Fasteners will be stainless steel, and lenses can be acrylic, polycarbonate or tempered glass, all with prisms on inside. Splash SplashZones Zones(SN) (SN) Kenall Kenallhas hastwo twolevels levelsofoffixture fixtureconstruction constructiondepending dependingononthe thearea area where wherethe thefixtures fixturesare arebeing beinginstalled. installed. Our OurSN SNtype typeconstruction constructionisislisted listedfor foruse useininSplash SplashZones Zonesand andNon Non HOSEDOWN RATINGS AND RELATION Food AllAllexposed metal IP65 FoodZones. Zones. exposedsheet sheet metalwill willbebepainted paintedCRS, CRS,painted painted TO IP RATINGS IP64/IP65 aluminum, aluminum,ororanodized anodizedaluminum. aluminum.Fasteners Fastenerswill willbebestainless stainlesssteel, steel, and andlenses lensescan canbebeacrylic, acrylic,polycarbonate polycarbonateorortempered temperedglass, glass,allallwith with prisms prismsononinside. inside. Limitations of Wet & Hosedown Ratings – UL Standards The Importance of Recognized Standards & Independent Testing UL standards for “wet” type ratings only offer a wet location rating, which simulates an outdoor rain condition. UL standards for a type 4 or NEMA 4 “hosedown” rating uses a 1 inch diameter nozzle on a fire hose delivering 65 gallons of water per minute. Various conditions exist where a fixture requires a rating better than a wet location label but not NEMA 4. These conditions typically exist in washdown applications where hose directed water or cleaning agents will be directed at the fixture. Benefits of Ingress Protection Ratings – IEC standards The IP water rating of “5” (IP_5), described in IEC Standard 60598, provides an intermediate step between the rain rating and the NEMA 4 rating. It also provides an internationally accepted standard which can be used to evaluate fixtures or any other electrical equipment, and the test can be performed by an independent third party testing agency for verification. Underwriters Laboratories investigates products and tests to the IEC standard. Other lighting manufacturers that claim a hosedown rating other than NEMA or IP are not testing to recognized standards and cannot have the tests confirmed or audited by an independent outside testing agency. Beware of statements such as “Tested to 75psi at 1 inch.” No reference is made to the volume of water that is leaving the nozzle and impacting the product. In fact, high nozzle pressures typically have low water volumes because the nozzle is restricting the flow of water causing the pressure in the hose to increase, minimizing the amount of water leaving the nozzle. Regardless of the hose pressure, any water volume less than 3.3 gal/minute is less severe than the IP_5 test. The most relevant characteristics are the diameter of the nozzle and the flow rate of the water. The following chart shows the test characteristics for various Standards. MedMaster™ Ratings Dust-tight Protection An additional test criterion that can be applied to fixtures is the ability to exclude solid matter. The IP solid rating of “6” (IP6_) means the fixture will be dust tight. The specified test requires that the fixture be placed in a circulating talc atmosphere for 3 hours. The particle size of the talc is a range of one to 75 microns and the fixture is placed under negative pressure in an attempt to draw the talc into the fixture. No talc shall be found inside the fixture after this test. When Whenyou yousee seethis thissymbol symbolyou youwill will know knowthe theKenall Kenallluminaire luminairehas hasbeen been tested ededtotothe testedand andcertifi certifi the NSF2 NSF2standard standard 54 Kenall’s MedMaster line of hosedown rated products are approved by UL and CUL for IP ratings according to IEC Standard 60598. When you see this symbol you will know the Kenall luminaire has been tested and certified to the What are IEC Standards? NSF2 standard IEC Standards are international standards that many European countries adopt as their national standard. North America has traditionally adopted UL standards as the source for standards. U.S. product manufacturers designed their products to IEC standards initially for sale overseas but are finding them increasingly useful P: 800-4-Kenall F: 847-360-1781 here in North America. www. kenall.com 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com Alpha Numeric Index PRODUCTBROCHURESPECIFICATION NUMBERPAGESHEET CMEXR. . . . . . . . . . . . . . . . . . . . . 4,11 . . . . . . . . . . . . 39 FN15D . . . . . . . . . . . . . . . . . . 5, 19, 33 . . . . . . . . . . . . 49 FN15L . . . . . . . . . . . . . . . . . . 5, 19, 33 . . . . . . . . . . . . 48 METDU . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . . . . . . . . . 34 METEC. . . . . . . . . . . . . . . 5, 13, 20-32 . . . . . . . . . . . . 41 METEL . . . . . . . . . . . . . . . 5, 15, 20-33 . . . . . . . . . . . . 42 METELHC . . . . . . . . . . . . . 5, 17, 20-33 . . . . . . . . . . . . 43 METER. . . . . . . . . . . . 5, 13, 15, 17,31 . . . . . . . . . . . . 44 METSR. . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . . . . . . . . . 37 METSS. . . . . . . . . . 4, 7, 13, 15, 17, 31 . . . . . . . . . . . . 40 METSU. . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . . . . . . . . . 35 METSW. . . . . . . . . . . . . . . . . . . . . . 4, 7 . . . . . . . . . . . . 36 MLER . . . . . . . . . . . . 5, 13, 15, 17, 21 . . . . . . . . . . . . 45 MMEX . . . . . . . . . . . . . . . . . . . . . . 4, 9 . . . . . . . . . . . . 38 MR17WP. . . . . . . . . . . . . . . . . 5, 19, 33 . . . . . . . . . . . . 47 MR17WPSR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com ©2009 Kenall Mfg. Co. All rights reserved.