Schools • HIGH ABUSE • healthcare • correctional • biosafety • TRANSPORTATION • INDUSTRIAL
Table of contents
Product Universe. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Metrex™ High Abuse Exit Sign. . . . . . . . . . . . . . . . . . 6-7
Mighty Mac™ Correctional Exit Sign. . . . . . . . . . . . . . 8-9
Simple Seal™ Sealed Enclosure Exit Sign. . . . . . . . 10-11
Metrex™ Combo Exit/Emergency Light . . . . . . . . . 12-13
Metrex™ Emergency Light. . . . . . . . . . . . . . . . . . . 14-15
Metrex™ High Capacity Emergency Light . . . . . . . 16-17
Millenium Round™ and Finite™. . . . . . . . . . . . . . . . . 18-19
Lighting Recommendations:
Corridor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21
Stairwell. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23
Corridor Intersection . . . . . . . . . . . . . . . . . . . . . . 24-25
Locker Room. . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-27
Multi-Purpose Room . . . . . . . . . . . . . . . . . . . . . . 28-29
Gymnasium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30-31
Jim Hawkins, President, Kenall Manufacturing
Building Exterior. . . . . . . . . . . . . . . . . . . . . . . . . . 32-33
Specification Sheets . . . . . . . . . . . . . . . . . . . . . . . . 34-49
LETTER FROM THE PRESIDENT
Kenall’s emergency lighting and signage products feature
the recently introduced Millenium Metrex™ LED exit sign
series for use in abusive public environments. We are
also excited to have added our Simple Seal™ exit signs
for environmentally critical areas such as cleanrooms and
containment areas.
NFPA Life Safety Code . . . . . . . . . . . . . . . . . . . . . . 50-52
Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . 53
Performance Listings. . . . . . . . . . . . . . . . . . . . . . . . 54-55
Alpha Numeric Index. . . . . . . . . . . . . . . . . . . . . . . . . . . 56
I am now proud to introduce our Millenium Metrex™
emergency egress lighting system. It includes a
comprehensive selection of all new injection molded
emergency lighting products for abusive, complex, and
extreme environments. This system represents the best of
lighting solutions for the specialized applications of
education, transportation, detention, industrial, sealed,
corrosive, wet, and other extreme environments. Our
offering includes a choice of high power battery packs,
exit, integrated combo units, and standard, architectural,
and satellite/low level exit remote heads. There is also a
high efficiency LED version that provides value, simplicity,
and cold weather reliability.
This brochure includes all of the emergency lighting and
signage options outlined above. All products are fully
explained, and the helpful application photos, graphics,
charts, and photometric data demonstrate the superior
performance of our innovative, high quality products.
I am sure you will be pleased with the way our
emergency lighting and signage series can enhance
your facility or business. At Kenall, we’re committed to
do our very best to assure your total satisfaction.
2
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
33
PRODUCT UNIVERSE
INDIRECT LED EXIT SIGNS
Millenium Metrex™
Millenium Metrex™
Millenium Metrex™
Millenium Metrex™
Simple Seal™
Mighty Mac™
Universal Mount
Single Face
METSU Series
Recessed Wall Mount
Single Face
METSR Series
Universal Mount
Double Face
METDU Series
Sealed Enclosure
Recessed Wall Mount
Single Face
CMEXR Series
Wall Mount
Single Face
METSW Series
Correctional
Wall / Ceiling Mount
Single or Double Face
MMEX Series
Remote-powerED INDIRECT LED EXIT SIGN
Millenium Metrex™
Satellite
Wall Surface Mount
Single Face
METSS Series
4
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
self-contained emergency luminaires
Millenium Metrex™
Millenium Metrex™
Millenium Metrex™
Millenium Metrex™
Emergency Light
Wall Mount
Two 12W or 20W Halogen MR16
METEL Series
Emergency Light
Wall Mount
Two or four fixed 6.5W LED MR16
METEL Series
High Capacity Emergency Light
Wall/Ceiling Mount
Two or four lamps
12W or 20W Halogen MR16,
or 6.5W LED MR16
METELHC Series
Exit/Emergency Combo
Wall Mount
Two or four lamps
12W or 20W Halogen MR16,
or 6.5W LED MR16
METEC Series
Remote-powerED EMERGENCY LUMINAIRES
Advantages of Kenall LED Emergency Luminaires
• LEDs offer long life (up to 50,000 hours)
• No filament – ideal for high vibration areas
• Fewer batteries to maintain and replace
Millenium Metrex™
Emergency Remote
Wall/Ceiling Mount
Two 12W or 20W Halogen MR16,
or two 6.5W LED MR16
METER Series
• Increased environmental sustainability (fewer batteries
means less manufacturing energy needed; less landfill
when batteries are replaced)
• Less operating energy required than other lamp types
• Cooler operation
• Simpler testing protocol
• Fewer emergency packs translates to lower
installation and system costs
LUMINAIRES WITH OPTIONAL EGRESS OPTICS
17" MILLENIUM™ ROUND
Wall Mount
HID w/two 12W or 20W Halogen MR16
MR17WP Series
17" MILLENIUM™ ROUND
Wall Mount
HID w/two 6.5W LED MR16
MR17WP Series
Millenium Finite™
15" Full Cutoff, Low Profile
Wall Mount
CFL or HID w/two 20W Halogen MR16
FN15L Series
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
55
millenium MetrEX™
Kenall’s Millenium Metrex™ exit sign is a best-in-class
Architectural High Abuse product combining state-of-the-art
LED technology, advanced optical performance, and legendary
Kenall durability in a visually pleasing package.
With a bright, evenly illuminated face that’s easily visible
without being obtrusive, Metrex LEDs are driven below
capacity to provide even longer life. Plus, the NiCad battery
backup option features deep cycle conditioning at initial startup
to maximize battery life; laser battery testing is standard. The
battery can power one METSS Satellite luminaire.
6
When it comes to durability, Millenium Metrex has no equal.
The highest quality injection molded polycarbonate housings,
baseplates, and mounting components make this exit sign able
to easily withstand severe environmental conditions and abuse.
The standard ambient temperature rating is 10°C to 45°C
(50°F to 113°F), and you can specify an optional cold weather
package rated to -45°C (-49°F).
Its IP64 rating certifies protection against water, dirt, and
dust while the Kenall Peace of Mind Guarantee® means we'll
replace the luminaire at no charge should it break at any time
during the life of the original installation.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
architectural high abuse exit signs and satellite
METSW SERIES
Kenall high abuse luminaires are designed and built
to take exceptional physical punishment. When
installed according to our instructions, Kenall will
repair or replace any high abuse luminaire rendered
inoperable due to physical abuse for the product
life of the original installation.
Refer to page 4 for other
Millenium Metrex™
Exit Signs, including
Single and Double Face,
Universal Mount.
METSS Satellite Exit
Remote-powered by any Kenall Exit sign, the METSS
Satellite is ideal where code requires floor proximity
exit signage. Can also be wall mounted above doors.
Features the same high abuse construction as all Metrex
High Abuse luminaires. See page 40 for spec sheet.
Housing
• Injection molded polycarbonate
•Continuous closed cell silicone gasket
• Multiple surface conduit feed
drill points
• Matte white or black available
Baseplate
• Injection molded polycarbonate
•One-piece die-cut closed cell
gasket pad
Exit Stencil
• Injection molded polycarbonate
•Field selectable directional chevrons
•Red or green polycarbonate
diffuser panels
Shield
•Clear injection molded polycarbonate
•Captive, tamper-resistant stainless
steel fasteners
•Continuous closed cell silicone gasket
Universal Mount Canopy
• Injection molded polycarbonate
•Heavy gauge steel mounting plate
•One-piece die-cut closed cell
gasket pad
Electrical Gear Tray
Listings
• Injection molded polycarbonate
•Long-life LEDs under-driven to
increase life:
Red at 60% capacity
Green at 25% capacity
•Remote Exit Ready – can power one
METSS Satellite Exit
• All electrical components feature quick
disconnects for ease of servicing
• UL and CUL listed for Wet Location
• IP64 rated to IEC 60598 (see page 55)
• Meets or exceeds UL924 and
NFPA 101 standards
•CUL tested and labeled to meet or
exceed CSA C22.2 No. 141, C860-01,
NRCAN/C860-01 requirements
Please refer to pages 34-37 for spec sheets
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
77
mighty mac™
Correctional facility exit signs must withstand extreme
physical abuse and tampering. That’s why Kenall developed
the Mighty Mac™ Correctional Exit Sign, a luminaire
incorporating the best practices of correctional luminaire
design with today’s most advanced LED technology.
Mighty Mac Exit Signs feature housings and mounting
components made from die-formed, heavy gauge, prime
grade cold rolled or stainless steel. The impact-resistant
polycarbonate lens includes a continuous retention system
and fully recessed, tamper-resistant stainless steel fasteners.
8
The result is a luminaire that is virtually impervious to the most
aggressive attempts to disable or remove parts. The standard
ambient temperature rating is 10°C to 45°C (50°F to 113°F),
and you can specify an optional cold weather package rated to
-45°C (-49°F). These features make the Mighty Mac Exit Sign
appropriate for any application requiring maximum mechanical
integrity and durability.
The bright exit face is evenly lit by LEDs under-driven to extend
their life. When specified with emergency battery backup, the
NiCad battery features self-testing, self-diagnostics, and deep
conditioning at initial startup to increase battery life.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
correctional exit signs
MMEX SERIES
Housing
•One-piece die-formed prime grade
heavy gauge cold rolled or
stainless steel
•Corners continuously seam welded
and smooth with no post grinding
• Matte white or black available
lens frame
•One-piece die-formed prime grade
heavy gauge cold rolled steel or
stainless steel
•Corners continuously seam welded
and smooth with no post grinding
•Fully recessed stainless steel
tamper-resistant fasteners
Exit Stencil
• Die-cut prime grade cold rolled steel
•Field selectable directional chevrons
•Red or green polycarbonate
diffuser panels
lens
•Clear polycarbonate
•Lens sealed inside lens frame with
gasket tape and secured with
continuous lens retention system
Electrical Gear Tray
finish
• 1,000-hour salt spray tested finish
UNIVERSAL MOUNT CANOPY
• Injection molded polycarbonate
•Heavy gauge steel mounting plate
Listings
• UL and CUL listed for Wet Location
• IP65 rated to IEC 60598 (see page 55)
• Meets or exceeds UL924 and
NFPA 101 standards
• Injection molded polycarbonate
•Long-life LEDs under-driven to
increase life:
Red at 60% capacity
Green at 25% capacity
•Remote Exit Ready – can power one
METSS Satellite Exit
• All electrical components feature quick
disconnects for ease of servicing
Please refer to page 38 for spec sheet
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
99
SIMPLE SEAL™
The Kenall family of Simple Seal™ sealed enclosure luminaires
offers specifiers the most comprehensively researched, most
carefully designed and best performing lighting tools available
for environmentally critical applications, including cleanrooms,
labs, and all types of containment areas.
The Simple Seal Recessed Exit Sign is no exception. It boasts
a lens frame with flush mounted stainless steel fasteners, a
one-piece, seam welded, cold rolled or stainless steel housing,
and polycarbonate lens with a continuous retention system.
With these features, the luminiare resists leakage and
surface contamination more effectively than any other exit
sign on the market.
10
It also meets Kenall's K230 & K229 Leakage Standards for
luminaire leakage in pressurized environments and Class 100
Cleanrooms; it is NSF2/Splash Zone listed, and IP65 rated to
IEC 60598.
The bright exit face is evenly illuminated by LEDs under-driven
to provide unusually long life. When specified with optional
battery backup, the supplied NiCad battery features deep
conditioning at initial startup to maximize battery life, plus
self-testing, self-diagnostics, protected manual push button,
and remote laser-testing. The standard ambient temperature
rating is 10°C to 45°C (50°F to 113°F), and you can specify an
optional cold weather package rated to -45°C (-49°F).
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
SEALED ENCLOSURE exit signs
CMEXR SERIES
Housing
lens
•One-piece die-formed prime grade
heavy gauge cold rolled steel or
stainless steel
•One-piece seam welded construction
• Matte white or black available
•Clear polycarbonate
•Lens sealed inside lens frame with
silicone sealant and secured with
continuous lens retention system
lens frame
•One-piece die-formed prime stainless
steel with 60° bevel
•Corners continuously seam welded
and smooth with no post grinding
•Fully recessed flush mounted
stainless steel fasteners
Exit Stencil
Electrical Gear Tray
• Injection molded polycarbonate
•Long-life LEDs under-driven to
increase life:
Red at 60% capacity
Green at 25% capacity
•Remote Exit Ready – can power one
METSS Satellite Exit
• All electrical components feature quick
disconnects for ease of servicing
finish
• 1,000-hour salt spray tested finish
Listings
• UL and CUL listed for Wet Location
• IP65 rated to IEC 60598 (see page 55)
•NSF2 – Splash Zone (see page 54)
• Meets K230 & K229 Leakage
Standards for luminaire leakage
in pressurized environments and
Class 100 Cleanrooms (see page 54)
• Independent lab tested to Federal
Standard 209E for Class 100
• Meets or exceeds UL924 and
NFPA 101 standards
•One-piece die-cut prime grade
cold rolled steel
•Field selectable directional chevrons
•Red or green polycarbonate
diffuser panels
Please refer to page 39 for spec sheet
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
11
11
millenium MetrEx™ combo
The Millenium Metrex™ Exit Sign and Emergency Lighting
Combo merges the finest high abuse luminaire design,
state-of-the-art LED technology, and MR16-based emergency
lighting that meets all Life Safety Code requirements at up to
114 foot luminaire spacing with a 7.5 foot typical mounting
height. The system can be specified with either two or four
12 or 20 watt halogen MR16s, or with two or four 6.5W LED
MR16s. The bright exit sign face is evenly illuminated by LEDs
under-driven to increase lamp life.
The NiCad battery features deep conditioning at initial startup
to maximize battery life, plus self-testing, self-diagnostics,
protected manual push button, and remote laser-testing.
12
The standard ambient temperature rating is 10°C to 45°C
(50°F to 113°F), and you can specify an optional cold weather
package rated to -30°C (-22°F). The injection molded
polycarbonate housing, lens, and mounting components
mean the system will withstand severe environmental and
physical abuse, while UL/CUL and IP64 rating protects
against intrusion of moisture, dirt, and unsightly debris.
In addition, Kenall’s exclusive Peace of Mind Guarantee® is
your assurance that the luminaire is covered against breakage
for the life of the installation.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
architectural high abuse combination exit sign / emergency lighting
METEC SERIES
The METEC Exit/Emergency Combo is
available with two or four MR16 lamps,
either 12W or 20W halogen, or 6.5W LED.
METSS Satellite Exit
Remote-powered by the
METEC, the METSS Satellite is
ideal where code requires floor
proximity exit signage; can also
be wall mounted above doors.
See page 40 for spec sheet.
METER REMOTE
emergency LIGHT
Please see page 44 for
spec sheet, and Battery
Charts on page 53 for
METER power options.
Housing
Electrical Gear Tray
• Injection molded polycarbonate
• Die-cut closed cell gasket pad
• Multiple surface conduit feed
drill points
• Matte white or black available
•Long-life LEDs under-driven to
increase life:
Red at 60% capacity
Green at 25% capacity
• Emergency lamp options include a
choice of two or four field-adjustable
12W or 20W halogen or 6.5 LED
MR16 lamps
•Remote Exit Ready – can power
one Kenall METSS Satellite Exit
•Remote Emergency Capability – can
power up to 71 watts of remote
lamps. (Refer to spec sheet on page
41 for battery rating chart and internal
lamp options.)
• All electrical components feature quick
disconnects for ease of servicing
Exit Stencil
• Injection molded polycarbonate
•Field selectable directional chevrons
•Red or green polycarbonate
diffuser panels
Shield
•Clear injection molded polycarbonate
•Captive, tamper-resistant stainless
steel fasteners
•Continuous closed cell silicone gasket
Please refer to page 20 for
Emergency Lighting Product Selector Chart
Listings
• UL and CUL listed for Wet Location
• IP64 rated to IEC 60598 (see page 55)
• Meets or exceeds UL924 and
NFPA 101 standards
•CUL tested and labeled to meet or
exceed CSA C22.2 No. 141, C860-01
requirements
Please refer to page 41 for spec sheet
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
13
13
millenium MetrEX™ EMERGENCY LIGHTING
14
The Millenium Metrex™ high abuse emergency lighting
system integrates Kenall’s industry-best high abuse design with
highly advanced emergency lighting technology. With injection
molded polycarbonate housing, gear tray cover, and lens, the
system is capable of withstanding some of the most severe
environmental and physical abuse imaginable.
The NiCad battery features deep conditioning at initial startup
to maximize battery life, plus self-testing, self-diagnostics,
protected manual push button, and remote laser-testing. The
standard ambient temperature rating is 10°C to 45°C (50°F to
113°F), and you can specify an optional cold weather package
rated to -30°C (-22°F).
Millenium Metrex’s standard UL/CUL IP64 rating means the
luminaire is protected against the intrusion of water, dirt, and
debris. And, like all Kenall high abuse luminaires, it’s protected
against breakage for the life of the original installation by our
exclusive Peace of Mind Guarantee®.
Available with two or four LED, or two halogen MR16 lamps,
carefully selected to provide the most appropriate distribution
and high lumen output, the METEL meets all Life Safety Code
requirements with up to 114 foot spacing between luminaires.
A 7.5 foot mounting height is recommended.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
ARCHITECTURAL HIGH ABUSE EMERGENCY LIGHTING
METEL SERIES
METEL Series with
four LED MR16s
METSS Satellite Exit
Remote-powered by the
METEL, the METSS Satellite is
ideal where code requires floor
proximity exit signage; can also
be wall mounted above doors.
See page 40 for spec sheet.
METER REMOTE
emergency LIGHT
Please see page 44 for
spec sheet, and Battery
Charts on page 53 for
METER power options.
6.5W LED version shown.
Housing AND GEAR TRAY COVER
Electrical Gear Tray
• Injection molded polycarbonate
• Die-cut closed cell gasket pad
• Multiple surface conduit feed
drill points
• Matte white or black available
• Emergency lamp options include a choice
of MR16 lamps:
– two field-adjustable 12 or 20W halogen
– two or four fixed position 6.5W LED
•Remote Exit Ready – can power up to
two Kenall METSS Satellite Exits
•Remote Emergency Capability – can
power up to 31 watts of remote lamps.
(Refer to spec sheet on page 42
for battery rating chart and internal
lamp options.)
• All electrical components feature quick
disconnects for ease of servicing
Shield
•Clear injection molded polycarbonate
•Captive, tamper-resistant stainless
steel fasteners
•Continuous closed cell silicone gasket
Please refer to page 20 for
Emergency Lighting Product Selector Chart
Listings
• UL and CUL listed for Wet Location
• IP64 rated to IEC 60598 (see page 55)
• Meets or exceed UL924 and
NFPA 101 standards
•CUL tested and labeled to meet or
exceed CSA C22.2 No. 141, C860-01
requirements
Please refer to page 42 for spec sheet
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
15
15
millenium METREX™ EMERGENCY LIGHTING
16
The Millenium Metrex™ two or four lamp, high capacity
battery-powered emergency lighting system combines the
most advanced battery technology available, the industry's
finest emergency lighting performance, and Kenall’s unmatched
high abuse design and fabrication techniques.
Both the two or four lamp configurations (12W or 20W halogen
or 6.5W LED MR16) meet all Life Safety Code requirements.
With a 7.5 foot mounting height, they can deliver up to 114 foot
spacing between luminaires. Each lamp type has been selected
for dependability, light distribution, and high lumen output.
The NiCad battery features deep conditioning at initial startup
to maximize battery life, plus self-testing, self-diagnostics,
protected manual push button, and remote laser-testing. The
standard ambient temperature rating is 10°C to 45°C (50°F to
113°F), and an optional cold weather package is available, rated
to -30°C (-22°F).
Injection molded polycarbonate housings, lenses, and mounting
components make this an emergency lighting system able to
withstand extreme environmental and physical abuse, while its
IP64 rating ensures protection against the intrusion of water,
dirt, and dust. Finally, Kenall’s Peace of Mind Guarantee®
means we’ll cover the luminaire against breakage for the life of
the installation.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
ARCHITECTURAL HIGH ABUSE EMERGENCY LIGHTING / 2- OR 4-LAMP HIGH CAPACITY BATTERY
METELHC SERIES
Two-lamp halogen MR16
version shown
The METELHC is available
with two or four 12W or 20W
halogen or 6.5W LED MR16s
METSS Satellite Exit
Remote-powered by the
METELHC, the METSS Satellite
is ideal where code requires
floor proximity exit signage;
can also be wall mounted above
doors. See page 40 for spec sheet.
Housing and gear tray cover
• Injection molded polycarbonate
•One-piece die-cut closed cell
gasket pad
• Multiple surface conduit feed
drill points
• Matte white or black available
Shield
•Clear injection molded polycarbonate
•Captive, tamper-resistant stainless
steel fasteners
•Continuous closed cell silicone gasket
METER REMOTE
emergency LIGHT
Please see page 44 for
spec sheet, and Battery
Charts on page 53 for
METER power options.
Electrical Gear Tray
• Emergency lamp options include a
choice of two or four field-adjustable
12W or 20W halogen or 6.5 LED
MR16 lamps
•Remote Exit Ready – can power up to
two Kenall METSS Satellite Exits
•Remote Emergency Capability – can
power up to 71 watts of remote
lamps. (Refer to spec sheet on page
43 for battery rating chart and internal
lamp options.)
• All electrical components feature quick
disconnects for ease of servicing
Please refer to page 20 for
Emergency Lighting Product Selector Chart
Listings
• UL and CUL listed for Wet Location
• IP64 rated to IEC 60598 (see page 55)
• Meets or exceeds UL924 and
NFPA 101 standards
•CUL tested and labeled to meet
or exceed CSA C22.2 No. 141,
C860-01 requirements
Please refer to page 43 for spec sheet
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
17
17
millenium™ 17" ROUND AND 15" FINITE™ emergency lighting SYSTEMS
Millenium™ Rounds and Millenium Finite™ wall-mounted
luminaires provide tough, attractive, and efficient building
exterior lighting combined with reliable emergency lighting
options. Each series features die-cast aluminum baseplates
with U.V. stabilized polycarbonate housings. The UL/CUL IP64
rating means the luminaire is protected from intrusion of water,
dirt, and debris. And they're protected against breakage for the
life of the original installation by the Kenall exclusive Peace of
Mind Guarantee®.
18
The emergency systems in the Millenium Round or Finite
luminaires can be remotely powered from any of Kenall’s
emergency luminaires. With a recommended 12 foot mounting
height, the 12 or 20 watt halogen or 6.5 watt LED MR16 lamps
can provide safe paths of egress up to 60 feet from the building
that exceed all Life Safety Code requirements.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
LUMINAIRES WITH EGRESS OPTICS
MR17WP SERIES millenium™ round
with egress optics option
•Remote-powered by any of Kenall's
emergency lighting systems
• Marine grade die-cast aluminum housing
•High impact-resistant, injection molded
polycarbonate lens base and eyelid
•Clear, U.V. stabilized, high impact-resistant
injection molded polycarbonate lens
•Two field adjustable 12 or 20 watt halogen or
6.5W LED MR16 emergency lamps
• UL and CUL listed for Wet Location;
IP64 rated to IEC 60598 (see page 55)
The 17" Millenium Round
is also available with two
6.5W LED MR16 lamps
Please refer to pages 46-47 for spec sheets
FN15L SERIES MILLENIUM FINITE™
with egress optics option
•Remote-powered by any of Kenall's
emergency lighting systems
•High impact-resistant, U.V. stabilized, injection
molded polycarbonate housing and door
• .250" clear tempered glass lens
•Two fixed 20W halogen or 6.5W LED MR16
emergency lamps
• UL and CUL listed for Wet Location; IP64 rated to
IEC 60598 (see page 55); IESNA-designated full
cut-off; IDA-Approved™ Dark-Sky Friendly Fixture
The Finite with Egress
Optics features two
fixed 20W halogen or
4.2W LED MR16 lamps
Please refer to pages 48-49 for spec sheets
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
19
19
CORRIDOR
Emergency lighting must adequately illuminate a 3' to 6' wide
path of egress down corridors, while exit signs must clearly
direct the way to the nearest exit.
of egress illuminated for up to 4 hours, Kenall has a Metrex™
emergency lighting system that can meet or exceed Life Safety
Code® requirements at unexpectedly wide luminaire spacings.
Kenall luminaires are able to meet or exceed all standards
for safely guiding occupants through corridors and out of the
building. When your application calls for a 3' or 6' wide path
The Emergency Lighting Product Selector Chart below will
direct you to emergency systems appropriate to your project's
specific needs.
Life Safety Code® is a registered trademark of the National Fire Protection Association, Quincy MA
Emergency Lighting Product Selector Chart
Product
Name
METEC24N
METEC24N
METEC24N
METEC40N
METEC40N
METEC40N
METEC48N
METEC48N
METEC48N
METEC48N
METEC80N
METEC80N
METEC80N
METEC80N
METEL24N
METEL24N
METEL24N
METEL40N
METEL40N
METEL40N
METELHC48N
METELHC48N
METELHC48N
METELHC48N
METELHC80N
METELHC80N
METELHC80N
METELHC80N
20
Lamp
Lamp
QuantityType
2
4
2
4
2
2
4
2
4
2
2
4
2
4
2
4
2
4
2
2
4
2
4
2
2
4
2
4
6.5W LED
6.5W LED
12W Halogen
6.5W LED
12W Halogen
20W Halogen
6.5W LED
12W Halogen
12W Halogen
20W Halogen
12W Halogen
12W Halogen
20W Halogen
20W Halogen
6.5W LED
6.5W LED
12W Halogen
6.5W LED
12W Halogen
20W Halogen
6.5W LED
12W Halogen
12W Halogen
20W Halogen
12W Halogen
12W Halogen
20W Halogen
20W Halogen
Duration (minutes) 240
120
90
160
120
90
240
180
90
108
240
120
180
90
240
120
90
160
120
90
240
180
90
108
240
120
180
90
Spacing for
3 ft. Path
71
114
30
114
30
69
114
30
47
69
30
47
69
113
71
114
30
114
30
69
114
30
47
69
30
47
69
113
Spacing for
6 ft. Path
56
100
21
100
21
59
100
21
41
59
21
41
59
103
56
100
21
100
21
59
100
21
41
59
21
41
59
103
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
Brochure
page #
Spec Sheet
page #
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
14-15
14-15
14-15
14-15
14-15
14-15
16-17
16-17
16-17
16-17
16-17
16-17
16-17
16-17
41
41
41
41
41
41
41
41
41
41
41
41
41
41
42
42
42
42
42
42
43
43
43
43
43
43
43
43
Recommended corridor LUMINAIRES
METEL – Halogen
Emergency Luminaire
page 15 (spec sheet pg. 42)
METEL – LED
Emergency Luminaire
page 15 (spec sheet pg. 42)
METELHC High Capacity
Emergency Luminaire
page 17 (spec sheet pg. 43)
METEC Combo Exit /
Emergency Luminaire
page 13 (spec sheet pg. 41)
Description:
Corridor Dimensions: 10' wide; 9' ceiling; 3' wide path of egress; Reflectance 80/50/20
Multiple Luminaires mounted at 7.5' height, each with four 6.5W LED MR16 lamps
CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance)
Location
Source
Room Floor
Kenall Luminaire
Room FloorLife Safety Code
Avg Fc
1.00
1.00
Max Fc
3.8
—
Min Fc
0.1
0.1
Avg/Min Fc
10.00
—
Max/Min Fc
38.00
40.00
114’
2’
3.0’
Path
Description
Corridor Dimensions: 10' wide; 9' ceiling; 6' wide path of egress; Reflectance 80/50/20
Multiple Luminaires mounted at 7.5' height, each with two 20W MR16 lamps
CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance)
Location
Source
Room Floor
Kenall Luminaire
Room FloorLife Safety Code
Avg Fc
1.00
1.00
Max Fc
2.6
—
Min Fc
0.3
0.1
Avg/Min Fc
3.33
—
Max/Min Fc
8.67
40.00
59’
2.0’
6.0’
Path
Description
Corridor Dimensions: 10' wide; 9' ceiling; 3' wide path of egress; Reflectance 80/50/20
Multiple Luminaires mounted at 7.5' height, each with two 20W MR16 lamps
CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance)
Location
Source
Room Floor
Kenall Luminaire
Room FloorLife Safety Code
Avg Fc
1.00
1.00
Max Fc
3.2
—
Min Fc
0.1
0.1
Avg/Min Fc
10.00
—
Max/Min Fc
32.00
40.00
69’
2’
3.0’
Path
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
21
21
STAIRWELL
Stairwells pose a particular challenge in emergency lighting
because changes in elevation demand luminaires that can
meet required illumination levels on both stairs and landings.
In addition, unsupervised stairwells are prone to vandalism.
Kenall's emergency luminaires meet the challenging
illumination requirements while exhibiting legendary Kenall
resistance to physical abuse and tampering.
Whether your emergency lighting need calls for a 3' or 6' wide
path of egress for up to 4 hours, there are Metrex™ lighting
systems capable of exceeding Life Safety Code requirements
even with impressively wide luminaire spacings. Please refer to
the Emergency Lighting Product Selector Chart below to find the
emergency systems that will best meet your specific needs.
Emergency Lighting Product Selector Chart
Product
Name
METEC24N
METEC24N
METEC24N
METEC40N
METEC40N
METEC40N
METEC48N
METEC48N
METEC48N
METEC48N
METEC80N
METEC80N
METEC80N
METEC80N
METEL24N
METEL24N
METEL24N
METEL40N
METEL40N
METEL40N
METELHC48N
METELHC48N
METELHC48N
METELHC48N
METELHC80N
METELHC80N
METELHC80N
METELHC80N
22
Lamp
Lamp
QuantityType
2
4
2
4
2
2
4
2
4
2
2
4
2
4
2
4
2
4
2
2
4
2
4
2
2
4
2
4
6.5W LED
6.5W LED
12W Halogen
6.5W LED
12W Halogen
20W Halogen
6.5W LED
12W Halogen
12W Halogen
20W Halogen
12W Halogen
12W Halogen
20W Halogen
20W Halogen
6.5W LED
6.5W LED
12W Halogen
6.5W LED
12W Halogen
20W Halogen
6.5W LED
12W Halogen
12W Halogen
20W Halogen
12W Halogen
12W Halogen
20W Halogen
20W Halogen
Duration (minutes) Brochure
page #
Spec Sheet
page #
240
120
90
160
120
90
240
180
90
108
240
120
180
90
240
120
90
160
120
90
240
180
90
108
240
120
180
90
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
14-15
14-15
14-15
14-15
14-15
14-15
16-17
16-17
16-17
16-17
16-17
16-17
16-17
16-17
41
41
41
41
41
41
41
41
41
41
41
41
41
41
42
42
42
42
42
42
43
43
43
43
43
43
43
43
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
Recommended STAIRWELL Luminaires
METEL – LED
Emergency Luminaire
page 15 (spec sheet pg. 42)
METEL – Halogen
Emergency Luminaire
page 15 (spec sheet pg. 42)
METELHC High Capacity
Emergency Luminaire
page 17 (spec sheet pg. 43)
METEC Combo Exit /
Emergency Luminaire
page 13 (spec sheet pg. 41)
Description
Closed Stairwell Dimensions: 6' wide x 16' long; 27' ceiling; five 6'x6' landings; 3' wide stairs; Reflectance 80/50/20
Multiple Luminaires mounted at 12.5', 20.0', and 25.85', each with two 20W MR16 lamps
CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance)
Location
Source
Landing 1
Kenall Luminaire
Landing 4
Kenall Luminaire
Stairs
Kenall Luminaire
Life Safety Code
Avg Fc
1.71
8.59
9.26
1.00
Max Fc
4.4
25.3
37.6
—
Min Fc
0.2
2.8
1.1
0.1
Avg/Min Fc
8.55
3.07
8.42
—
Max/Min Fc
22.00
9.04
34.18
40.00
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
23
23
CORRIDOR INTERSECTION
Intersections are common places for large numbers of people
to converge. That's why it's important in these areas to
combine high capacity emergency lighting with reliable exit
signage to safely guide occupants out of these larger and
potentially confusing areas. The four-lamp halogen or LED
METEC Combo unit is ideal for meeting both requirements
with a single luminaire.
Whether you're creating a 3' or 6' wide path of egress for up
to four hours, Kenall has a Metrex™ lighting system with the
performance to exceed Life Safety Code requirements. Use the
Emergency Lighting Product Selector Chart below to identify the
lighting system best able to meet your project needs.
Emergency Lighting Product Selector Chart
Product
Name
METEC24N
METEC24N
METEC24N
METEC40N
METEC40N
METEC40N
METEC48N
METEC48N
METEC48N
METEC48N
METEC80N
METEC80N
METEC80N
METEC80N
METEL24N
METEL24N
METEL24N
METEL40N
METEL40N
METEL40N
METELHC48N
METELHC48N
METELHC48N
METELHC48N
METELHC80N
METELHC80N
METELHC80N
METELHC80N
24
Lamp
Lamp
QuantityType
2
4
2
4
2
2
4
2
4
2
2
4
2
4
2
4
2
4
2
2
4
2
4
2
2
4
2
4
6.5W LED
6.5W LED
12W Halogen
6.5W LED
12W Halogen
20W Halogen
6.5W LED
12W Halogen
12W Halogen
20W Halogen
12W Halogen
12W Halogen
20W Halogen
20W Halogen
6.5W LED
6.5W LED
12W Halogen
6.5W LED
12W Halogen
20W Halogen
6.5W LED
12W Halogen
12W Halogen
20W Halogen
12W Halogen
12W Halogen
20W Halogen
20W Halogen
Duration (minutes) Brochure
page #
Spec Sheet
page #
240
120
90
160
120
90
240
180
90
108
240
120
180
90
240
120
90
160
120
90
240
180
90
108
240
120
180
90
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
14-15
14-15
14-15
14-15
14-15
14-15
16-17
16-17
16-17
16-17
16-17
16-17
16-17
16-17
41
41
41
41
41
41
41
41
41
41
41
41
41
41
42
42
42
42
42
42
43
43
43
43
43
43
43
43
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
Recommended corridoR INTERSECTION Luminaires
METEL – Halogen
Emergency Luminaire
page 15 (spec sheet pg. 42)
METEL – LED
Emergency Luminaire
page 15 (spec sheet pg. 42)
METELHC High Capacity
Emergency Luminaire
page 17 (spec sheet pg. 43)
METEC Combo Exit /
Emergency Luminaire
page 13 (spec sheet pg. 41)
Description
Corridors: 12' wide; 9' ceiling; 6' wide path of egress
Multiple Luminaires at 7.5' mounting height
Lamps: Two and Four 20W MR16
Reflectance 80/50/20
CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance)
Location
Source
Room Floor
Kenall Luminaire
Room FloorLife Safety Code
Avg Fc
1.70
1.00
Max Fc
5.7
—
Min Fc
0.3
0.1
Avg/Min Fc
5.67
—
Max/Min Fc
19.00
40.00
30’
42’
3.0’
6’
Path
3.0’
140’
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
25
25
Locker Room
Because locker rooms usually have several aisles and paths
of egress, it may be necessary to install exit signs in multiple
locations to ensure quick and safe exit during an emergency.
Remote emergency luminaires like the METER, and satellites
such as the METSS, are ideal, cost-effective solutions,
particularly when used in combination with tough and efficient
Millenium Metrex™ high abuse exit signs.
When you need to provide a 3' or 6' wide path of egress
illuminated for up to four hours, there's a Metrex™ system
that even at impressively wide spacings can exceed Life Safety
Code requirements. The Emergency Lighting Product Selector
Chart below will direct you to the different Kenall systems
appropriate for your specific application.
Emergency Lighting Product Selector Chart
Product
Name
METEC24N
METEC24N
METEC24N
METEC40N
METEC40N
METEC40N
METEC48N
METEC48N
METEC48N
METEC48N
METEC80N
METEC80N
METEC80N
METEC80N
METEL24N
METEL24N
METEL24N
METEL40N
METEL40N
METEL40N
METELHC48N
METELHC48N
METELHC48N
METELHC48N
METELHC80N
METELHC80N
METELHC80N
METELHC80N
26
Lamp
Lamp
QuantityType
2
4
2
4
2
2
4
2
4
2
2
4
2
4
2
4
2
4
2
2
4
2
4
2
2
4
2
4
6.5W LED
6.5W LED
12W Halogen
6.5W LED
12W Halogen
20W Halogen
6.5W LED
12W Halogen
12W Halogen
20W Halogen
12W Halogen
12W Halogen
20W Halogen
20W Halogen
6.5W LED
6.5W LED
12W Halogen
6.5W LED
12W Halogen
20W Halogen
6.5W LED
12W Halogen
12W Halogen
20W Halogen
12W Halogen
12W Halogen
20W Halogen
20W Halogen
Duration (minutes) Brochure
page #
Spec Sheet
page #
240
120
90
160
120
90
240
180
90
108
240
120
180
90
240
120
90
160
120
90
240
180
90
108
240
120
180
90
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
14-15
14-15
14-15
14-15
14-15
14-15
16-17
16-17
16-17
16-17
16-17
16-17
16-17
16-17
41
41
41
41
41
41
41
41
41
41
41
41
41
41
42
42
42
42
42
42
43
43
43
43
43
43
43
43
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
Recommended LOCKER ROOM Luminaires
METEL
Emergency Luminaire
page 15 (spec sheet pg. 42)
METELHC High Capacity
Emergency Luminaire
page 17 (spec sheet pg. 43)
METEC Combo Exit /
Emergency Luminaire
page 13 (spec sheet pg. 41)
MLER Remote
page 13 (spec sheet pg. 45)
Description
Locker Room: 26'x60'; 9' ceiling; 3' wide path of egress
Multiple Luminaires at 7.5' mounting height or ceiling mounted
Lamps: 12W MR16
Reflectance 80/50/20
CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance)
Location
Source
Locker Area
Kenall Luminaire
Shower Area
Kenall Luminaire
Lavatory Area
Kenall Luminaire
RoomLife Safety Code
Avg Fc
1.04
1.10
1.50
1.00
Max Fc
3.6 2.2 3.1
—
Min Fc
0.2
0.4
0.4
0.1
Avg/Min Fc
5.20 2.75
3.75 —
Max/Min Fc
18.00
5.50
7.75
40.00
12’
LAVATORY
AREA
13’
LOCKER AREA
26’
SHOWER AREA
1’
60’
24’
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
27
27
Multi-Purpose Room
Multi-purpose rooms pose many of the same challenges as
locker rooms, including the illumination of multiple exits.
Because of their typically large footprints, however,
multi-purpose rooms demand more powerful emergency
luminaires in order to adequately illuminate their broader
dimension while making potential obstacles to egress
visible to occupants.
For applications such as this, calling for high output emergency
lighting for up to four hours, there's a Metrex™ system with
the performance you need to meet the Life Safety Code
requirements – even at impressively wide luminaire spacings.
The Emergency Lighting product Selector Chart below will
direct you to the Kenall systems appropriate for multi-purpose
room projects.
Emergency Lighting Product Selector Chart
Product
Name
METEC24N
METEC24N
METEC24N
METEC40N
METEC40N
METEC40N
METEC48N
METEC48N
METEC48N
METEC48N
METEC80N
METEC80N
METEC80N
METEC80N
METEL24N
METEL24N
METEL24N
METEL40N
METEL40N
METEL40N
METELHC48N
METELHC48N
METELHC48N
METELHC48N
METELHC80N
METELHC80N
METELHC80N
METELHC80N
28
Lamp
Lamp
QuantityType
2
4
2
4
2
2
4
2
4
2
2
4
2
4
2
4
2
4
2
2
4
2
4
2
2
4
2
4
6.5W LED
6.5W LED
12W Halogen
6.5W LED
12W Halogen
20W Halogen
6.5W LED
12W Halogen
12W Halogen
20W Halogen
12W Halogen
12W Halogen
20W Halogen
20W Halogen
6.5W LED
6.5W LED
12W Halogen
6.5W LED
12W Halogen
20W Halogen
6.5W LED
12W Halogen
12W Halogen
20W Halogen
12W Halogen
12W Halogen
20W Halogen
20W Halogen
Duration (minutes) 240
120
90
160
120
90
240
180
90
108
240
120
180
90
240
120
90
160
120
90
240
180
90
108
240
120
180
90
Spacing for
3 ft. Path
71
114
30
114
30
69
114
30
47
69
30
47
69
113
71
114
30
114
30
69
114
30
47
69
30
47
69
113
Spacing for
6 ft. Path
56
100
21
100
21
59
100
21
41
59
21
41
59
103
56
100
21
100
21
59
100
21
41
59
21
41
59
103
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
Brochure
page #
Spec Sheet
page #
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
14-15
14-15
14-15
14-15
14-15
14-15
16-17
16-17
16-17
16-17
16-17
16-17
16-17
16-17
41
41
41
41
41
41
41
41
41
41
41
41
41
41
42
42
42
42
42
42
43
43
43
43
43
43
43
43
Recommended MULTI-PURPOSE ROOM Luminaires
METEL – Halogen
Emergency Luminaire
page 15 (spec sheet pg. 42)
METEL – LED
Emergency Luminaire
page 15 (spec sheet pg. 42)
METELHC High Capacity
Emergency Luminaire
page 17 (spec sheet pg. 43)
METEC Combo Exit /
Emergency Luminaire
page 13 (spec sheet pg. 41)
Description
Multi-Purpose Room: 60'x80'; 25' ceiling; 6' wide path of egress
Multiple Luminaires at 12' mounting height
Lamps: Two 20W MR16
Reflectance 80/50/20
CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance)
Location
Source
Room Floor
Kenall Luminaire
Room FloorLife Safety Code
Avg Fc
1.18
1.00
Max Fc
3.9
—
Min Fc
0.3
0.1
Avg/Min Fc
3.93
—
Max/Min Fc
13.00
40.00
80’
60’
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
29
29
gymnasium
Gymnasiums are a tough environment for lighting fixtures.
Even mounted high on walls, luminaires have to be incredibly
rugged to survive the impact of balls traveling at high speeds,
while those located within arm’s reach also need to withstand
tampering and vandalism. With injection molded polycarbonate
construction, Kenall Metrex Emergency luminaires will stand up
to the physical demands of this environment, while providing the
higher level of illumination needed in such a large, open space.
Kenall state-of-the art LED Emergency Remotes are an ideal
energy- and cost-efficient solution for gyms. A single METEC
Combo Exit/Emergency luminaire can power up to eight
two-lamp METER Remotes, while exceeding Life Safety Code
requirements. This means just one battery to purchase and
maintain for an entire gymnasium application. Refer to the
Emergency Lighting Product Selector Chart below to select the
ideal system for your project.
Emergency Lighting Product Selector Chart
Product
Name
METEC24N
METEC24N
METEC24N
METEC40N
METEC40N
METEC40N
METEC48N
METEC48N
METEC48N
METEC48N
METEC80N
METEC80N
METEC80N
METEC80N
METEL24N
METEL24N
METEL24N
METEL40N
METEL40N
METEL40N
METELHC48N
METELHC48N
METELHC48N
METELHC48N
METELHC80N
METELHC80N
METELHC80N
METELHC80N
30
Lamp
Lamp
QuantityType
2
4
2
4
2
2
4
2
4
2
2
4
2
4
2
4
2
4
2
2
4
2
4
2
2
4
2
4
6.5W LED
6.5W LED
12W Halogen
6.5W LED
12W Halogen
20W Halogen
6.5W LED
12W Halogen
12W Halogen
20W Halogen
12W Halogen
12W Halogen
20W Halogen
20W Halogen
6.5W LED
6.5W LED
12W Halogen
6.5W LED
12W Halogen
20W Halogen
6.5W LED
12W Halogen
12W Halogen
20W Halogen
12W Halogen
12W Halogen
20W Halogen
20W Halogen
Duration (minutes) 240
120
90
160
120
90
240
180
90
108
240
120
180
90
240
120
90
160
120
90
240
180
90
108
240
120
180
90
Spacing for
3 ft. Path
71
114
30
114
30
69
114
30
47
69
30
47
69
113
71
114
30
114
30
69
114
30
47
69
30
47
69
113
Spacing for
6 ft. Path
56
100
21
100
21
59
100
21
41
59
21
41
59
103
56
100
21
100
21
59
100
21
41
59
21
41
59
103
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
Brochure
page #
Spec Sheet
page #
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
12-13
14-15
14-15
14-15
14-15
14-15
14-15
16-17
16-17
16-17
16-17
16-17
16-17
16-17
16-17
41
41
41
41
41
41
41
41
41
41
41
41
41
41
42
42
42
42
42
42
43
43
43
43
43
43
43
43
Recommended gymnasium Luminaires
METEL – Halogen or LED
Emergency Luminaire
page 15 (spec sheet pg. 42)
METELHC High Capacity
Emergency Luminaire
page 17 (spec sheet pg. 43)
METEC Combo Exit /
Emergency Luminaire
page 13 (spec sheet pg. 41)
METER Remote Emergency METSS Satellite Exit
page 13 (spec sheet pg. 44) page 7 (spec sheet pg. 40)
Description
Gymnasium: 110'x110'; 25' ceiling; 6' wide path of egress
Multiple Luminaires at 12' mounting height, 50' spacings; one Exit satellite and seven Remote luminaires powered by one METEC80N
Lamps: 6.5W LED MR16
Reflectance 80/50/20
CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance)
Location
Source
Room Floor
Kenall Luminaire
Room FloorLife Safety Code
METER Remote
w/(2) 6.5W LED
METER Remote
w/(2) 6.5W LED
Avg Fc
1.05
1.00
Max Fc
3.7
—
Min Fc
0.1
0.1
Avg/Min Fc
10.5
—
Max/Min Fc
37.00
40.00
METER Remote
w/(2) 6.5W LED
METEC80N
w/(2) 6.5W LED
110’
METER Remote w/ (2) 6.5W LED
and METSS Satellite Exit
METER Remote
w/(2) 6.5W LED
METER Remote
w/(2) 6.5W LED
METER Remote
w/(2) 6.5W LED
2’
Wire recommendations:
METEC to METSS – 14 ga.
METEC to METER – 12 ga.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
31
31
Building Exterior
Building exterior emergency luminaires pose a unique lighting
challenge in that they not only need to reliably illuminate
a path of egress away from the building, but also stand
up against physical and environmental abuse. Millenium™
Round and Finite™ are ideal solutions for both requirements
when specified with the auxiliary emergency lighting option.
When your application calls for emergency lighting to provide
a 3' or 6' wide path of egress, illuminated for up to four hours,
Kenall has a Metrex™ lighting system that will provide
impressive luminaire spacings while exceeding Life Safety
Code requirements. The Emergency Lighting Product Selector
Chart below will direct you to alternate lighting systems that
meet your specific needs.
Emergency Lighting Product Selector Chart
Product
Name
32
Lamp
LampMounting
QuantityType
Height (ft.)
Path of Egress Width (ft.) Length (ft.)
Brochure
page #
Spec Sheet
page #
METEL / METELHC
METEL / METELHC
METEL / METELHC
METEL / METELHC
METEL / METELHC
METEL / METELHC
METEL / METELHC
METEL / METELHC
METEL / METELHC
METEL / METELHC
METEL / METELHC
METEL / METELHC
2
2
4
4
2
2
4
4
2
2
4
4
6.5W LED
6.5W LED 6.5W LED
6.5W LED
12W Halogen
12W Halogen
12W Halogen
12W Halogen
20W Halogen
20W Halogen
20W Halogen
20W Halogen
12
12
12
12
12
12
12
12
12
12
12
12
6
3
6
3
6
3
6
3
6
3
6
3
46
52
79
86
16
18
30
32
47
51
77
80
14-15
14-15
14-15
14-15
14-15
14-15
14-15
14-15
14-15
14-15
14-15
14-15
42-43
42-43
42-43
42-43
42-43
42-43
42-43
42-43
42-43
42-43
42-43
42-43
MR17WP
MR17WP
MR17WP
MR17WP
MR17WP
MR17WP
2
2
2
2
2
2
6.5W LED
6.5W LED
12W Halogen
12W Halogen
20W Halogen
20W Halogen
12
12
12
12
12
12
6
3
6
3
6
3
46
52
16
18
47
51
18-19
18-19
18-19
18-19
18-19
18-19
46-47
46-47
46-47
46-47
46-47
46-47
FN15L
FN15L
FN15L
FN15L
2
2
2
2
6.5W LED
6.5W LED
20W Halogen
20W Halogen
12
12
12
12
6
3
6
3
43
50
43
49
18-19
18-19
18-19
18-19
48-49
48-49
48-49
48-49
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
Recommended building exterior LUMINAIRES
METEL – Halogen or LED
Emergency Luminaire
page 15 (spec sheet pg. 42)
METEL – LED
METELHC High Capacity
Emergency Luminaire
Emergency Luminaire
page 15 (spec sheet pg. 42) page 17 (spec sheet pg. 43)
MR17WP Millenium™ Round
w/Egress Optics option
page 19 (spec sheets pgs. 46-47)
FN15L Millenium Finite™
w/Egress Optics option
page 19 (spec sheets pgs. 48-49)
Description
Building Exterior: 3' wide path of egress
Luminaire: 17" Millenium™ Round mounted over door at 12'
Lamps: Two 20W Halogen MR16
CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance)
Location
Source
Room Floor
Kenall Luminaire
Room FloorLife Safety Code
Avg Fc
1.00
1.00
Max Fc
3.8
—
Min Fc
0.1
0.1
Avg/Min Fc
10.00
—
Max/Min Fc
38.00
40.00
Building Facade
51’
3’
52’
Description
Building Exterior: 3' wide path of egress
Luminaire: 17" Millenium™ Round mounted over door at 12'
Lamps: Two 6.5W LED MR16
Reflectance 80/50/20
3’
51’
CALCULATION SUMMARY (Footcandles are initial; Calculation Type is Illuminance)
Location
Source
Room Floor
Kenall Luminaire
Room FloorLife Safety Code
Avg Fc
1.01
1.00
Max Fc
3.9
—
Min Fc
0.1
0.1
Avg/Min Fc
10.10
—
3’
Max/Min Fc
39.00
40.00
Building Facade
52’
3’
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
33
33
PROJECT INFORMATION
MILLENIUM METREX™
Job Name
Fixture Type
METDU SERIES
Catalog Number
PRODUCT FEATURES:
Approved by
» Surface mount – wall or ceiling; Double Face
» Indirect Red or Green LED
» Internal Battery Backup System
» High impact injection polycarbonate construction
SPECIFICATIONS
HOUSING: High impact, injection molded polycarbonate. Housing provided with canopy mounting and wireway drill points top and side – see Cross Section/Details. Closed cell die-cut Neoprene
gasket seals housing to canopy.
SHIELD: UV-stabilized, high impact, injection molded clear polycarbonate. Nominal thickness .120". Captive stainless steel Torx® with center pin fasteners secure shield to housing. Continuous
closed cell silicone gasket seals shield to housing.
CANOPY: High impact, injection molded polycarbonate canopy cover with heavy gauge galvanized steel mounting plate with integral 1/4-20 threaded studs. Canopy mounting plate provided with
four-point mounting holes, one wireway hole and temporary junction box mounting holes. Closed cell die-cut Neoprene gasket seals canopy to mounting surface.
LEGEND: Legend illuminated by internal high output LEDs. Lettering six inches high with .750" stroke. Polycarbonate red or green filter panels. High impact, injection molded polycarbonate stencil
and field selectable chevron inserts.
ELECTRICAL: 624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Remote Exit Ready – can power one
Kenall METSS Satellite Exit.
OPTIONS: Sealed nickel-cadmium Emergency Battery Pack (EL) with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected
mechanical test switch and status indicator. Provides 120 minutes of emergency operation. The Emergency Battery Pack (EL) is suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency
Battery Pack (CL) suitable for -30°C to 45°C (-22°F to 113°F). Remote Exit Ready – can power one or two Kenall METSS Satellite Exits.
INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®. Drill points provided for optional conduit entry.
LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements. NSF2 Splash
and Non-Food Zone.
LED
IP64
UL
924
NFPA
101
ORDERING INFORMATION (Ex: METDU-MW-R-DT)
Model
Finish
Legend Color
Finish
MB Matte Black
MW Matte White
Legend Color
R
Red
G
Green
Voltage
Options
Accessories
METDU
Options
CEL Cold Weather Emergency Battery Pack
EL
Standard Emergency Battery Pack
XAC Auxiliary AC Supply (matches voltage selection)
XDC Auxiliary DC Supply (6-24 volts)
Voltage
DT 120/277 Volts
DTC 120/347 Volts
Accessories
LP
Laser Pointer
9500 Torx® Screwdriver
DIMENSIONAL DATA
Ceiling Mount
Ceiling Canopy Mounting View
8.80"
7.00"
9.55"
4.00"
14.00"
4.04"
End Mount
(4) .31" Mounting Holes
5.80"
2.00" Dia. Hole
End Canopy Mounting View
5.80"
4.00"
8.80"
8.80"
4.04"
7.00"
14.75"
(4) .31" Mounting Holes
www.kenall.com
P: 800-4-Kenall
F: 262-891-9701
2.00" Dia. Hole
10200 55th Street Kenosha, Wisconsin 53144
When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy
American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found
at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.
METDU_121613
34
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
PROJECT INFORMATION
MILLENIUM METREX™
Job Name
Fixture Type
METSU SERIES
Catalog Number
PRODUCT FEATURES:
Approved by
» Surface mount – wall or ceiling;
Single Face
» Indirect Red or Green LED
» Internal Battery Backup System
» High impact polycarbonate construction
SPECIFICATIONS
HOUSING: High impact, injection molded polycarbonate. Housing provided with canopy mounting and wireway drill points top and side – see Cross Section/Details. Closed cell die-cut Neoprene
gasket seals housing to canopy.
SHIELD: UV-stabilized, high impact, injection molded clear polycarbonate. Nominal thickness .120". Captive stainless steel Torx® with center pin fasteners secure shield to housing. Continuous
closed cell silicone gasket seals shield to housing.
CANOPY: High impact, injection molded polycarbonate canopy cover with heavy gauge galvanized steel mounting plate with integral 1/4-20 threaded studs. Canopy mounting plate provided with
four-point mounting holes, one wireway hole and temporary junction box mounting holes. Closed cell die-cut Neoprene gasket seals canopy to mounting surface.
LEGEND: Illuminated by internal high output LEDs. Lettering six inches high with .750" stroke. Polycarbonate red or green filter panels. High impact, injection molded polycarbonate stencil and field
selectable chevron inserts.
ELECTRICAL: 624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Remote Exit Ready – can power one
Kenall METSS Satellite Exit.
OPTIONS: Sealed nickel-cadmium Emergency Battery Pack (EL) with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected
mechanical test switch and status indicator. Provides 120 minutes of emergency operation. The Emergency Battery Pack (EL) is suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency
Battery Pack (CL) suitable for -30°C to 45°C (-22°F to 113°F). Remote Exit Ready – can power one or two Kenall METSS Satellite Exits.
INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®. Drill points provided for optional conduit entry.
LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements. NSF2 Splash/
Non-Food Zone.
LED
IP64
UL
924
NFPA
101
ORDERING INFORMATION (Ex: METSU-MW-R-DT-EL)
Model
Finish
Legend Color
Voltage
Options
Accessories
METSU
Finish
MB Matte Black
MW Matte White
Voltage
DT 120/277 Volts
DTC 120/347 Volts
Legend Color
R
Red
G
Green
Options
CEL Cold Weather Emergency Battery Pack
EL
Standard Emergency Battery Pack
XAC Auxiliary AC Supply (matches voltage selection)
XDC Auxiliary DC Supply (6-24 volts)
DIMENSIONAL DATA
Ceiling Mount
Accessories
LP
Laser Pointer
9500 Torx® with center pin Screwdriver
Ceiling Canopy Mounting View
8.80"
7.00"
9.55"
4.00"
5.80"
14.00"
3.27"
End Mount
(4) .31" Mounting Holes 2.00" Dia. Hole
End Canopy Mounting View
5.80"
4.00"
8.80"
8.80"
7.00"
3.27"
14.75"
www.kenall.com
P: 800-4-Kenall
(4) .31" Mounting Holes
F: 262-891-9701
2.00" Dia. Hole
10200 55th Street Kenosha, Wisconsin 53144
When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy
American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found
at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.
METSU-010214
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
35
PROJECT INFORMATION
MILLENIUM METREX™
Job Name
Fixture Type
METSW SERIES
Catalog Number
PRODUCT FEATURES:
Approved by
» Surface wall mount – Single Face
» Indirect Red or Green LED
» Internal Battery Backup System
» High impact polycarbonate construction
SPECIFICATIONS
HOUSING: High impact, injection molded polycarbonate. Housing provided with four-point mounting holes, one wireway hole and temporary junction box mounting drill points – see Cross Section/
Details. Closed cell die-cut Neoprene gasket seals housing to mounting surface.
SHIELD: UV-stabilized, high impact, injection molded clear polycarbonate. Nominal thickness .120". Captive stainless steel Torx® with center pin fasteners secure shield to housing. Continuous
closed cell silicone gasket seals shield to housing.
LEGEND: Legend illuminated by internal high output LEDs. Lettering six inches high with .750 inch stroke. Polycarbonate red or green filter panels. High impact, injection molded polycarbonate
stencil and field selectable chevron inserts.
ELECTRICAL: 624nm RED or 527nm GREEN LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Remote Exit Ready – can power one
Kenall METSS Satellite Exit.
OPTIONS: Sealed nickel-cadmium Emergency Battery Pack (EL) with standard battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected mechanical test
switch and status indicator. Provides 120 minutes of emergency operation; The Emergency Battery Pack (EL) is suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery Pack (CL)
suitable for -30°C to 45°C (-22°F to 113°F). Remote Exit Ready – can power one or two Kenall METSS Satellite Exits.
INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®. Drill points provided for optional surface conduit entry. NSF2 Splash and Non-Food Zone.
LISTINGS: UL and CUL listed for Wet Locations. UL Classified IP64 per IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements. NSF2 Splash
and Non-Food Zone.
LED
IP64
UL
924
NFPA
101
ORDERING INFORMATION (Ex: METSW-MW-R-DT-EL)
Model
Finish
Legend Color
Voltage
Options
Accessories
METSW
Finish
MB Matte Black
MW Matte White
Voltage
DT 120/277 Volts
DTC 120/347 Volts
Legend Color
R
Red
G
Green
Options
CEL Cold Weather Emergency Battery Pack
EL
Standard Emergency Battery Pack
XAC Auxiliary AC Supply (matches voltage selection)
XDC Auxiliary DC Supply (6-24 volts)
DIMENSIONAL DATA
Accessories
LP
Laser Pointer
9500 Torx® with center pin Screwdriver
Baseplate Mounting View
14.00"
3.27"
7.00"
8.80"
4.00"
(4) .31" Mounting Holes
www.kenall.com
P: 800-4-Kenall
F: 262-891-9701
.875" Dia. Hole
10200 55th Street Kenosha, Wisconsin 53144
When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy
American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found
at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.
METSW-010214
36
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
PROJECT INFORMATION
MILLENIUM METREX™
Job Name
Fixture Type
METSR SERIES
Catalog Number
PRODUCT FEATURES:
Approved by
» Semi-recessed wall mount – Single Face
» Indirect Red or Green LED
» Internal Battery Backup System
» 20-gauge cold rolled steel housing
» Self diagnostic testing features
SPECIFICATIONS
HOUSING: 20-gauge CRS. Hole-free one-piece seam welded construction.
FRAME: One-piece die-formed prime grade 16-gauge material as specified – see Ordering Information. Corners continuously seam welded and smooth with no post grinding (TIG).
LENS: External panel .188" thick clear polycarbonate.
LEGEND: Legend illuminated by internal high output LEDs. Lettering six inches high with .750" stroke. Polycarbonate red or green filter panels. High impact, punched, formed and painted sheet
metal stencil and field selectable chevron inserts.
FASTENERS: Hardened security screws as specified – see ordering information.
FINISH: TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%. See Options for black exterior.
ELECTRICAL: 624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Remote Exit Ready – can power one
Kenall METSS Satellite Exit.
OPTIONS: Sealed nickel-cadmium Emergency Battery Pack (EL) with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected
mechanical test switch and status indicator. Provides 120 minutes of emergency operation. Emergency Battery Pack (EL) suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery
Pack (CEL) suitable for -45°C to 45°C (-49°F to 113°F). (When used with a Kenall METSS, this fixture provides 90 minutes of emergency operation.)
LISTINGS: UL and CUL listed for Wet Location. UL certified IP65 in compliance with IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements.
LED
IP65
UL
924
NFPA
101
ORDERING INFORMATION (Ex: METSR-1-R-DT-1-EL)
Model
Frame Material
Legend Color
Voltage
Fastener
Options
Accessories
METSR
Frame Material
1
16-Ga CRS (Painted)
4
16-Ga SS (Painted)
7
16-Ga SS (Brushed)
Accessories
LP
Laser Pointer
9500 Torx® with center pin Screwdriver
Legend Color
G
Green
R
Red
Fasteners
1
Torx® Head w/ Center Pin
2
Allen Head w/ Center Pin
Voltage
DT 120/277 Volts
DTC 120/347 Volts
Options
BLK Black Exterior Frame and Exit Face
CEL Cold Weather Emergency Battery Pack
EL
Standard Emergency Battery Pack
XAC Auxiliary AC Supply (matches voltage selection)
XDC Auxiliary DC Supply (6-24 volts)
DIMENSIONAL DATA
Side View
Mounting Details
16.00"
.35"
(4) .31"
Dia. K.O.
10.75"
Frame
12.31" x 16.04"
(4) 1/2"
EMT K.O.
14.50"
2.38"
www.kenall.com
Stud Spacing 16"
Rough Opening 10.75" x 14.50"
P: 800-4-Kenall
F: 262-891-9701
10200 55th Street Kenosha, Wisconsin 53144
When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy
American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found
at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.
METSR-010214
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
37
37
PROJECT INFORMATION
Job Name
MIGHTY MAC™
Fixture Type
MMEX SERIES
Catalog Number
PRODUCT FEATURES:
Approved by
» Surface mount – wall or ceiling
» 14-gauge cold rolled steel or stainless
steel housing
» Indirect Red or Green LED
» Single and Double Face
SPECIFICATIONS
HOUSING: One-piece die-formed prime 14-gauge grade material as specified – see ordering information. Corners continuously seam welded and smooth with no post grinding (TIG).
DOOR: One-piece die-formed prime grade 14-gauge. Corners continuously seam welded and smooth with no post grinding (TIG).
LEGEND: Legend illuminated by internal high output LEDs. Lettering six inches high with .750 inch stroke. Internal panels with stencil cut letters and red or green filter panel. External panel .188"
thick clear polycarbonate. Universal arrows.
FASTENERS: Hardened security screws as specified – see ordering information.
FINISH: TGIC polyester powder coat – 5-stage pre-treatment. Salt spray test: 1,000 hours; Reflectance: 92%. See Options for black exterior.
ELECTRICAL: 624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Exit Ready – can power one Kenall
METSS Satellite Exit.
OPTIONS: Sealed nickel-cadmium Emergency Battery Pack (EL) with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected
mechanical test switch and status indicator. Provides 120 minutes of emergency operation. Emergency Battery Pack (EL) suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery
Pack (CEL) suitable for -45°C to 45°C (-49°F to 113°F). (When used with a Kenall METSS, this fixture provides 90 minutes of emergency operation.)
LISTINGS: UL and CUL listed for Wet Location. UL Classified IP65 per IEC 60598. Meets or exceeds UL924 and NFPA 101 Standards. Meets or exceeds CSA and NRCAN requirements.
LED
IP65
UL
924
NFPA
101
ORDERING INFORMATION (Ex: MMEX-1-0-G-DT-1)
Model
Face
Hsg. and Dr. Material
Legend Color
Voltage
Fasteners
Options
Accessories
MMEX
Face
1
Single Face
2
Double Face
Housing and Door Material
0
14-Ga CRS (Painted)
3
14-Ga SS (Painted)
6
14-Ga SS (Brushed)
Legend Color
G
Green
R
Red
www.kenall.com
Voltage
DT 120/277 Volts
DTC 120/347 Volts
Fasteners
1
Torx® Head w/ Center Pin
2
Allen Head w/ Center Pin
P: 800-4-Kenall
F: 262-891-9701
Options
BLK Black Exterior
EL
Standard Emergency Battery Pack
CEL Cold Weather Emergency Battery Pack
XAC Auxiliary AC Supply (Matches Voltage Selection)
XDC Auxiliary DC Supply (6-24 Volts)
Accessories
LP
Laser Pointer
9500 Torx® Screwdriver
10200 55th Street Kenosha, Wisconsin 53144
When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy
American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found
at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.
MMEX-102214
38
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
PROJECT INFORMATION
SIMPLESEAL™
Job Name
Fixture Type
CMEXR SERIES
Catalog Number
PRODUCT FEATURES:
» Recessed wall mount – Single Face
Approved by
» Indirect Red or Green LED
» Self diagnostic testing features
» One-piece seam welded housing
» 304 stainless steel overlapping doorframe
SPECIFICATIONS
HOUSING: 20-gauge CRS standard – see ordering information. Hole-free one-piece seam welded construction. White TGIC polyester powder coat finish – 5 step pre-treatment. Salt spray test: 1,000
hours; Reflectance: 92%.
DOORFRAME: 20-gauge type 304 stainless steel (#4 finish-post fabrication) standard – see ordering information. One-piece 60° beveled perimeter construction. Continuous angle lens retention
system. Mechanical guide for doorframe fastener alignment. Doorframe secured to housing with 4 captive flush mounted Phillips head stainless steel fasteners.
DOORFRAME GASKET: One-piece closed cell extruded silicone gasket seals doorframe to housing and wall structure.
LENS: .125" clear polycarbonate lens sealed to perimeter ledge of lens aperture with silicone sealant and secured with continuous lens retention system.
LEGEND: Legend illuminated by internal high output LEDs. Lettering six inches high with .750" stroke. Polycarbonate red or green filter panels. High impact, punched, formed and painted sheet
metal stencil and field selectable chevron inserts.
ELECTRICAL: 624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Exit Ready – can power one Kenall
METSS Satellite Exit.
OPTIONS: Sealed nickel-cadmium Emergency Battery Pack (EL) with standard deep cycle battery conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected
mechanical test switch and status indicator. Provides 120 minutes of emergency operation. Emergency Battery Pack (EL) suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery
Pack (CEL) suitable for -45°C to 45°C (-49°F to 113°F). (When used with a Kenall METSS, this fixture provides 90 minutes of emergency operation.)
PATENT: U.S. Patent No. 5, 902, 035.
LISTINGS: UL and CUL Listed for Wet Location. UL certified IP65 per IEC 60598. NSF2 Splash/Non-Food Zone. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN
requirements. FED-STD-209E/Class 100 (ISO 5) Cleanrooms.
LED
UL
924
IP65
ISO 5
NFPA
101
Class 100
ORDERING INFORMATION (Ex: CMEXR-5F-R-DT-NT-EL)
Model
Frame Material
Legend Color
Voltage
Mounting
Options
Accessories
CMEXR
Frame Material
5F
20-Ga Type 304 SS (STD)
2F
20-Ga CRS Painted White
XF
20-Ga Type 316 SS
Legend Color
G
Green
R
Red
Mounting
NT Recessed Mounting Tray for new construction; fits16" stud spacing,
5/8" wall thickness (tray is mounted before drywall installed)
RT
Recessed Retrofit Mounting Tray for existing construction;
10.75"×14.5" opening required
Voltage
DT 120/277 Volts
DTC 120/347 Volts
Options
CEL Cold Weather Emergency Battery Pack
EL
Standard Emergency Battery Pack
BEF Black Exit Face for 5F or XF SS Frame
BLK Black Exterior CRS Frame and Exit Face
XAC Auxiliary AC Supply (matches voltage selection)
XDC Auxiliary DC Supply (6-24 volts)
Accessory
LP
Laser Pointer
Side View
DIMENSIONAL DATA
Face View
12.29"
2.62"
Back View
Gasket Profile
Stud Spacing 16" /Rough Opening 10.75" × 14.50"
Wall Thickness 5/8"
16.00"
(1) 7/8" Dia. Hole
Wall
10.75"
Fixture
Housing
14.50"
(4) .31"
Dia. K.O.
16.05"
www.kenall.com
Gasket
mechanically
retained
P: 800-4-Kenall
Lens
Frame
F: 262-891-9701
10200 55th Street Kenosha, Wisconsin 53144
When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy
American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found
at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.
CMEXR-010214
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
39
39
PROJECT INFORMATION
MILLENIUM METREX™
Job Name
Fixture Type
METSS SERIES
Catalog Number
PRODUCT FEATURES:
Approved by
» Surface wall mount – Single Face
» Indirect Red or Green LED
» Satellite Exit
» High impact polycarbonate construction
SPECIFICATIONS
HOUSING: High impact, injection molded polycarbonate. Housing provided with four-point mounting holes, one wireway hole and temporary junction box mounting drill points – see Cross Section/
Details. Closed cell die-cut Neoprene gasket seals housing to mounting surface.
SHIELD: UV-stabilized, high impact, injection molded clear polycarbonate. Nominal thickness .120". Captive stainless steel Torx® with center pin fasteners secure shield to housing. Continuous
closed cell silicone gasket seals shield to housing.
LEGEND: Legend illuminated by internal high output LEDs. Lettering six inches high with .750" stroke. Polycarbonate red or green filter panels. High impact, injection molded polycarbonate stencil
and field selectable chevron inserts.
ELECTRICAL: 624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable high impact, injection molded polycarbonate chassis. Powered by external 4VDC power
supply as provided by Kenall METDU, METSU, METSW, METSR, MMEX, CMEXR, METEC, METEL or METELHC.
INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®.
LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements.
LED
IP64
UL
924
NFPA
101
ORDERING INFORMATION (Ex: METSS-MW-R-4DVC)
Model
Finish
Legend Color
METSS
Voltage
Options
Accessories
Voltage*
4VDC 4 Volts DC
Option
PH Phillips Head Fasteners
4VDC
Finish
MB Matte Black
MW Matte White
Legend Color
R
Red
G
Green
Accessory
9500 Torx® with center pin Screwdriver
*METSS can be powered by METDU,
METSU, METSW, METSR, MMEX, CMEXR,
METEC, METEL, METELHC
DIMENSIONAL DATA
Baseplate Mounting View
2.08"
9.00"
15.20"
10.00"
6.00"
(4) .312" Dia. Mounting Holes
www.kenall.com
P: 800-4-Kenall
F: 262-891-9701
.875" Dia. Hole
10200 55th Street Kenosha, Wisconsin 53144
When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy
American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found
at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.
METSS-121613
40
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
PROJECT INFORMATION
MILLENIUM METREX™
Job Name
Fixture Type
METEC SERIES
Catalog Number
Approved by
PRODUCT FEATURES:
» Surface wall mount – Single Face
» Indirect Red or Green LED
» Exit/Emergency combo unit
» High impact polycarbonate construction
SPECIFICATIONS
HOUSING: High impact, injection molded polycarbonate. Housing provided with four-point mounting holes, one wireway hole and temporary junction box mounting drill points – see Cross Section/
Details. Closed cell die-cut Neoprene gasket seals housing to mounting surface.
SHIELD: UV-stabilized, high impact, injection molded clear polycarbonate. Nominal thickness .120". Captive stainless steel Torx® with center pin fasteners secure shield to housing. Continuous
closed cell silicone gasket seals shield to housing.
LEGEND: Legend illuminated by internal high output LEDs. Lettering six inches high with .750" stroke. Polycarbonate red or green filter panels. High impact, injection molded polycarbonate stencil
and field selectable chevron inserts.
ELECTRICAL: 624 nm Red or 527 nm Green LED light source. Electrical components mounted to removable chassis. Sealed nickel-cadmium Emergency Battery Pack with standard deep cycle battery
conditioning, self test and self diagnostic circuitry, remote laser activated test switch, protected mechanical test switch and status indicator. Suitable for 10°C to 45°C (50°F to 113°F). Cold Weather
Emergency Battery Pack (CL) suitable for -30°C to 45°C (-22°F to 113°F). Remote Exit Ready – can power one Kenall METSS Satellite Exits. Can also power Kenall METER Emergency Remote Unit(s);
selected total lamp wattage – including all remotes – cannot exceed unit output rating; consult Output Rating chart
INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®. Drill points provided for optional surface conduit entry.
LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements.
LED
IP64
UL
924
NFPA
101
ORDERING INFORMATION (Ex: METEC-24N-MW-R-2-6.5L-120)
Model
Battery Capacity
Finish
Legend Color
Lamp Qty
Lamp Watt/Type
Voltage
Options
Accessories
METEC
Battery Capacity
24N 24W Nickel Cadmium
40N 40W Nickel Cadmium
48Nâ—Ź 48W Nickel Cadmium
80Nâ—Ź 80W Nickel Cadmium
OUTPUT RATING
Battery *½ hr *1 hr 1½ hr 2 hr
24N 48W 32W 24W 18W
40N 80W 53W 40W 30W
48N 96W 64W 48W 36W
80N 160W106W 80W 60W
*per Canadian code
Finish
MB Matte Black
MW Matte White
Legend Color
R
Red
G
Green
Lamp Quantity
2
2 Internal Lamps
4
4 Internal Lamps
3 hr 4 hr
12W 9W
20W 15W
24W 18W
40W 30W
Options
CEL** Cold Weather Emergency Battery Pack
PH Phillips Head Fasteners
Lamp Wattage/Type*
12H 12W Halogen
20H 20W Halogen
6.5L 6.5W LED
Accessories
LP
Laser Pointer
9500 Torx® with center pin Screwdriver
Voltage
120 120 Volts
DT 120/277 Volts
DTC 120/347 Volts
*Selected total lamp wattage cannot exceed
unit output rating. Consult Output Rating
Chart on left.
**n/a with 80N battery capacity or DTC voltage.
â—Ź
n/a with 6.5W LED lamp type.
DIMENSIONAL DATA
20.50"
5.96"
9.50"
14.50"
6.00"
(4) .312" Dia.
Mounting Holes
www.kenall.com
P: 800-4-Kenall
F: 262-891-9701
2.00" Dia. Hole
10200 55th Street Kenosha, Wisconsin 53144
When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy
American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found
at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.
METEC-112614
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
41
41
PROJECT INFORMATION
MILLENIUM METREX™
Job Name
Fixture Type
METEL SERIES
Catalog Number
Approved by
PRODUCT FEATURES:
» Surface wall mount
» Self contained emergency light
» Self diagnostic testing features
» High impact polycarbonate construction
SPECIFICATIONS
SHIELD: UV-stabilized, high impact, injection molded clear polycarbonate. Nominal thickness .120". Captive stainless steel Torx® with center pin fasteners secure shield to housing. Continuous
closed cell silicone gasket seals shield to housing.
HOUSING: High impact, injection molded polycarbonate. Housing provided with four-point mounting holes, one wireway hole and temporary junction box mounting drill points – see Cross Section/
Details. Closed cell die-cut Neoprene gasket seals housing to mounting surface.
ELECTRICAL: Electrical components mounted to removable chassis. Sealed nickel-cadmium Emergency Battery Pack with standard deep cycle battery conditioning, self test and self diagnostic
circuitry, remote laser activated test switch, protected mechanical test switch and status indicator. Suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery Pack (CL) suitable for
-30°C to 45°C (-22°F to 113°F). Remote Exit Ready – can power one or two Kenall METSS Satellite Exits. Can also power Kenall METER Emergency Remote Unit(s); selected total lamp wattage –
including all remotes – cannot exceed unit output rating; consult Output Rating chart
INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®. Drill points provided for optional surface conduit entry.
LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements.
LED
IP64
UL
924
NFPA
101
ORDERING INFORMATION (Ex: METEL-24N-MW-2-6.5L-120)
Model
Battery Capacity
Finish
Lamp Qty
Lamp Wattage/Type
Voltage
Options
Accessories
METEL
Battery Capacity
24N 24W Nickel Cadmium
40N 40W Nickel Cadmium
Finish
MB Matte Black
MW Matte White
OUTPUT RATING
Battery *½ hr *1 hr 1½ hr 2 hr 3 hr 4 hr
24N 48W 32W 24W 18W 12W 9W
40N 80W 53W 40W 30W 20W 15W
*per Canadian code
Lamp Quantity
2
2 Internal Lamps
4
4 Internal Lamps (LED only – fixed optics)
Lamp Wattage/Type*
12H 12W Halogen
20H 20W Halogen
6.5L 6.5W LED
Voltage
120 120 Volts
DT 120/277 Volts
DTC 120/347 Volts
Accessories
LP
Laser Pointer
9500 Torx® with center pin Screwdriver
Options
CEL** Cold Weather Emergency Battery Pack
PH Phillips Head Fasteners
* Selected total lamp wattage cannot
exceed unit output rating. Consult
Output Rating Chart on left.
**n/a with 40N battery capacity
or DTC voltage.
DIMENSIONAL DATA
Baseplate Mounting View
5.20"
6.00"
9.50"
12.00"
8.50"
(4) .312" Dia.
Mounting Holes
www.kenall.com
P: 800-4-Kenall
F: 262-891-9701
2.00" Dia. Hole
10200 55th Street Kenosha, Wisconsin 53144
When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy
American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found
at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.
METEL-121613
42
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
PROJECT INFORMATION
MILLENIUM METREX™
Job Name
Fixture Type
METELHC SERIES
Catalog Number
Approved by
PRODUCT FEATURES:
» Surface mount – wall or ceiling
» High capacity battery options
» Self contained emergency light
» Self diagnostic testing features
» High impact polycarbonate construction
SPECIFICATIONS
HOUSING: High impact, injection molded polycarbonate. Housing provided with four-point mounting holes, one wireway hole and temporary junction box mounting drill points – see Cross Section/
Details. Closed cell die-cut Neoprene gasket seals housing to mounting surface.
SHIELD: UV stabilized, high impact, injection molded clear polycarbonate. Nominal thickness .120". Captive stainless steel Torx® with center pin fasteners secure shield to housing. Continuous
closed cell silicone gasket seals shield to housing.
ELECTRICAL: Electrical components mounted to removable chassis. Sealed nickel-cadmium Emergency Battery Pack with standard deep cycle battery conditioning, self test and self diagnostic
circuitry, remote laser activated test switch, protected mechanical test switch and status indicator. Suitable for 10°C to 45°C (50°F to 113°F). Cold Weather Emergency Battery Pack (CEL) suitable for
-30°C to 45°C (-22°F to 113°F). Remote Exit Ready – can power one or two Kenall METSS Satellite Exits. Can also power Kenall METER Emergency Remote Unit(s); selected total lamp wattage –
including all remotes – cannot exceed unit output rating; consult Output Rating chart
INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®. Drill points provided for optional surface conduit entry.
LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. Meets or exceeds UL924 and NFPA 101 standards. Meets or exceeds CSA and NRCAN requirements.
LED
IP64
UL
924
NFPA
101
ORDERING INFORMATION (Ex: METELHC-24N-MW-2-6.5L-120)
Model
Battery Capacity
Finish
Lamp Qty
Lamp Type
Voltage
Options
Accessories
METELHC
Battery Capacity
24N 24W Nickel Cadmium
40N 40W Nickel Cadmium
48Nâ—Ź 48W Nickel Cadmium
80Nâ—Ź 80W Nickel Cadmium
Finish
MB Matte Black
MW Matte White
OUTPUT RATING
Battery *½ hr *1 hr 1½ hr 2 hr
24N 48W 32W 24W 18W
40N 80W 53W 40W 30W
48N 96W 64W 48W 36W
80N 160W106W 80W 60W
*per Canadian code
3 hr 4 hr
12W 9W
20W 15W
24W 18W
40W 30W
Lamp Quantity
2
2 Internal Lamps
4
4 Internal Lamps
Options
CEL** Cold Weather Emergency Battery Pack
PH Phillips Head Fasteners
Lamp Wattage/Type*
12H 12W Halogen
20H 20W Halogen
6.5L 6.5W LED
Accessories
LP
Laser Pointer
9500 Torx® with center pin Screwdriver
Voltage
120 120 Volts
DT 120/277 Volts
DTC 120/347 Volts
* Selected total lamp wattage cannot exceed
unit output rating. Consult Output Rating
Chart on left.
** n/a with 80N battery capacity or
DTC voltage.
â—Ź
n/a with 6.5W LED lamp type.
DIMENSIONAL DATA
20.50"
5.96"
9.50"
14.50"
6.00"
(4) .312" Dia. Mounting Holes
www.kenall.com
2.00" Dia. Hole
P: 800-4-Kenall
F: 262-891-9701
10200 55th Street Kenosha, Wisconsin 53144
When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy
American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found
at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.
METELHC-010214
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
43
43
PROJECT INFORMATION
MILLENIUM METREX™
Job Name
Fixture Type
METER SERIES
Catalog Number
PRODUCT FEATURES:
Approved by
» Surface mount – wall or ceiling
» Emergency Remote Unit
» ADA compliant
» 16-gauge cold rolled steel baseplate
» UV-stabilized high impact clear wraparound
polycarbonate lens
SPECIFICATIONS
LENS/HOUSING: One-piece wraparound lens/housing, UV-stabilized, high impact, virgin injection molded polycarbonate. Nominal thickness .120".
BASEPLATE: 16-gauge CRS. Baseplate provided with four-point mounting holes, one wireway hole – see Cross Section/Details. White TGIC polyester powder coat – 5-stage pre-treatment. Salt spray
test: 1,000 hours; Reflectance: 92%.
GASKET: Die-cut closed cell neoprene gasket seals lens/housing to mounting surface.
HARDWARE: Four stainless steel Torx® with center pin fasteners secure lens/housing to baseplate.
ELECTRICAL: 12V AC or DC operation. Field adjustable emergency lamps. Powered by external 12VDC power supply as provided by Kenall METEC, METEL or METELHC.
INSTALLATION: Standard four-point mounting required for Peace of Mind Guarantee®.
LISTINGS: UL and CUL listed for Wet Location. Meets or exceeds UL924 and NFPA 101 standards.
LED
UL
924
NFPA
101
ADA
ORDERING INFORMATION (Ex: METER-MW-2-6.5L-12VAC/DC)
Model
Finish
Lamp Qty
Lamp Type
METER
Voltage
Options
Accessories
12VAC/DC
Finish
MB Matte Black
MW Matte White
Lamp Quantity
1
1 Internal Lamp
2
2 Internal Lamps
Voltage
12VAC/DC 12 Volt AC/DC
Accessories
9500 Torx® Screwdriver
Options
PH Phillips Head Fasteners
SA Die-Cast Surface Adapter (Non ADA)
Lamp Wattage/Type
12H 12W Halogen
20H 20W Halogen
6.5L 6.5W LED
DIMENSIONAL DATA
SURFACE ADAPTER
BASEPLATE MOUNTING
3.98"
3.88"
5.76"
5.94"
9.12"
6.50"
8.50"
6.44"
8.94"
6.50"
3.80"
3.81"
6.31"
5.88"
(4) .281" Dia.
2.00" Dia. Hole
Mounting Holes
www.kenall.com
P: 800-4-Kenall
3/4" IPS Tapped
(4) .281" Dia.
Mounting Holes
F: 262-891-9701
10200 55th Street Kenosha, Wisconsin 53144
When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy
American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found
at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.
METER-010214
44
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
PROJECT INFORMATION
MILLENIUM™ ROUND
Job Name
Fixture Type
MR17 SERIES – HIGH PERFORMANCE, SEMI-RECESSED
Catalog Number
PRODUCT FEATURES:
Approved by
» Semi-recessed wall mount – 17"Dia. ×4"D
» Peace of Mind Guarantee® against breakage
» Dust and water protected to IP64 standards
» Wide path lateral throw (MR17WPSR),
narrow path forward throw (MR17NPSR)
» ADA compliant
WP
NP
SPECIFICATIONS
HOUSING (SERIES PP, ND): Die-cast aluminum housing with integral heat sinks. Housing interlocks and wraps around lens base producing maximum moisture deflection and resistance to prying.
Standard bronze exterior TGIC polyester powder coat – 5-step pre-treatment.
HOUSING (SERIES NL): 18-gauge CRS housing. Housing interlocks and wraps around lens base producing maximum moisture deflection and resistance to prying. Standard white exterior TGIC
polyester powder coat – 5-step pre-treatment.
REFLECTOR: Precision designed semi-specular reflector (semi-cutoff) produces an elongated lateral and shallow distribution. System produces aesthetically pleasing illumination of narrow passages
at maximum fixture spacings with minimal light trespass.
LENS: UV-stabilized, high impact resistant, virgin injection molded clear polycarbonate lens. The high efficiency lens is designed to enhance appearance without beam scatter. Close tolerance push/
turn/lock-in-place mating of injection molded base and lens facilitates set up and installation. Base and lens secured with one concealed captive Torx® with center pin fastener.
LENS BASE: Marine grade cast aluminum. Lens base shields lamp from viewing angles. Standard black, bronze or white exterior TGIC polyester powder coat finished – 5-step pre-treatment. See
Ordering Information for optional finishes.
EYELID: High impact resistant, injection molded opaque black, bronze or white polycarbonate. Optional Light Gray, Silver, Forest Green or Custom Color (see Ordering Information below) are
chemically bonded, impact resistant finishes.
GASKETING: Closed cell, silicone “O” ring gaskets positioned in gasket channels of lens base and in Series PP, ND housing.
HARDWARE: One stainless steel Torx® with center pin fastener.
ELECTRICAL: HID ballasts high power factor. Metal halide lamps utilize pulse start technology. Shock absorbing, medium base lamp sockets provided for HID lamps.
INSTALLATION: See Technical Data Sheets for semi-recessed installation details, mounting accessories and rough-in box availability.
WARRANTY: Standard four-point mounting and polycarbonate lens required for Peace of Mind Guarantee®.
LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598.
IP64
ADA
ORDERING INFORMATION (Ex: MR17NPSR-PP-C-LG-70S-1-120)
Model
Mounting
Lens Type
Finish
Lamp Type
Lamp Qty
C
Model
MR17NPSR Narrow
MR17WPSR Wide
Mounting Type
PP
Pour-in-Place or Masonry
ND Non IC (Deep Profile)
NL Non IC (Low Profile)
Lens Type
C
Clear Polycarbonate
Voltage
Options
Accessories
1
Finish
MB Matte Black
MW Matte White
DB Dark Bronze
LG Light Gray
SL
Silver
FG Forest Green
CC Custom Color (Consult factory)
Lamp Type (Qty/Ballast/Volt./Starting Temp)
50M† 50 Watt MH (1/HPF/120,277,347/-20°F)
50S
50 Watt HPS (1/HPF/120,277/-40°F)
70M† 70 Watt MH (1/HPF/120,277,347/-20°F)
70S
70 Watt HPS (1/HPF/120,277,347/-40°F)
100M† 100 Watt MH (1/HPF/120,277,347/-20°F)
100S 100 Watt HPS (1/HPF/120,277,347/-40°F)
Lamp Quantity
1
One Lamp
Voltage
120
120 Volts
277
277 Volts
347
347 Volts
www.kenall.com
Options
AUX20H• Low Voltage Emergency Auxiliary Lamp (12VDC) w/(2) 20W
Halogen MR16 lamps supplied by Kenall (MR17WPSR only)
AUX6.5L• Low Voltage Emergency Auxiliary Lamp (12VDC) w/(2) 6.5W
LED MR16s supplied by Kenall (MR17WPSR only)
FS
Single Fuse & Holder
NAT
Natatorium Environment Option
QR
Quartz restrike system for maximum 100 Watt DC bay quartz
lamp (see 9009)
QRC
Hot/Cold Quartz restrike
QS
Quartz socket only
QS2
Two Quartz sockets (max. 50W ea.) (MR17WPSR only)
RAK
Remote Arc Keeper (100M lamp type only)
XAC*
Auxiliary Emergency Lighting (120V AC)
Accessories
9009
100 Watt DC Bay Quartz Lamp
50QL
50 Watt Candelabra Base Quartz Lamp
9500
Torx® Screwdriver
†
*
•
P: 800-4-Kenall
F: 262-891-9701
UV shielding lamp supplied
Configured to accommodate two emergency quartz lamps
(50W max). Lamps by others.
12VDC Power to be supplied by others.
10200 55th Street Kenosha, Wisconsin 53144
When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy
American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found
at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.
MR17_NPSR_WPSR-120213
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
45
45
PROJECT INFORMATION
MILLENIUM™ ROUND
Job Name
Fixture Type
MR17 SERIES – HIGH PERFORMANCE
Catalog Number
PRODUCT FEATURES:
Approved by
» Surface wall mount – 17"Dia. ×9"D
» Peace of Mind Guarantee® against breakage
» Dust and water protected to IP64 standards
» Wide path lateral throw (MR17WP),
narrow path forward throw (MR17NP)
» Optional egress optics available (MR17WP)
WP
NP
SPECIFICATIONS
HOUSING: Marine grade die-cast aluminum. Rib reinforced construction. Integral heat sinks. Housing flange interlocks and wraps around lens base producing maximum moisture deflection and
resistance to prying. Housing provided with four-point mounting holes, one wireway hole and temporary junction box mounting drill points. Standard black, bronze or white exterior TGIC polyester
powder coat – 5-step pre-treatment. See Ordering Information for optional finishes.
REFLECTOR: Precision designed semi-specular reflector (semi-cutoff) produces an elongated lateral and shallow distribution. System produces aesthetically pleasing illumination of narrow
passages at maximum fixture spacings with minimal light trespass.
LENS: UV-stabilized, high impact resistant, virgin injection molded clear polycarbonate lens. The high efficiency lens is designed to enhance appearance without beam scatter. Close tolerance push/
turn/lock-in-place mating of injection molded base and lens facilitates set up and installation. Base and lens secured with one concealed captive Torx® with center pin fastener.
LENS BASE/EYELID: Lens base shields lamp from viewing angles. High impact resistant, injection molded opaque black, bronze or white polycarbonate. Optional Light Gray, Silver, Forest Green or
Custom Color (see Ordering Information below) are chemically bonded, impact resistant finishes.
GASKETING: Die-cut, closed cell neoprene self adhesive gasket seals housing to mounting surface. Closed cell, silicone “O” ring gaskets positioned and friction secured in gasket channels of lens
base and housing.
HARDWARE: One stainless steel Torx® with center pin fastener.
ELECTRICAL: HID ballasts high power factor. Metal halide lamps utilize pulse start technology. Shock absorbing, medium base lamp sockets provided for HID lamps.
INSTALLATION: HID units cannot be inverted to be an uplight.
WARRANTY: Standard four-point mounting and polycarbonate lens required for Peace of Mind Guarantee®.
LISTINGS: UL listed for Wet Location. UL certified IP64 per IEC 60598.
IP64
ORDERING INFORMATION (Ex: MR17NP-C-SL-150S-1-277)
Model
Lens Type
Finish
Lamp Type
C
Model
MR17NP Narrow
MR17WP Wide
Lens Type
C
Clear Polycarbonate
Finish
MB Matte Black
MW Matte White
DB Dark Bronze
LG Light Gray
SL
Silver
FG Forest Green
CC Custom Color (Consult factory)
Lamp Qty
Voltage
Options
Accessories
1
Lamp Type (Qty/Ballast/Volt./Starting Temp)
50M† 50 Watt MH (1/HPF/120,277,347/-20°F)
50S
50 Watt HPS (1/HPF/120,277/-40°F)
70M† 70 Watt MH (1/HPF/120,277,347/-20°F)
70S
70 Watt HPS (1/HPF/120,277,347/-40°F)
100M† 100 Watt MH (1/HPF/120,277,347/-20°F)
100S 100 Watt HPS (1/HPF/120,277,347/-40°F)
150M† 150 Watt MH (1/HPF/120,277,347/-20°F)
150S 150 Watt HPS (1/HPF/120,277,347/-40°F)
Lamp Quantity
1
One Lamp
Voltage
120
120 Volts
277
277 Volts
347â–˛ 347 Volts
Options
AUX20H• Low Voltage Emergency Auxiliary Lamp (12VDC) w/(2) 20W
Halogen MR16 lamps supplied by Kenall (MR17WP only)
AUX6.5L• Low Voltage Emergency Auxiliary Lamp (12VDC) w/(2) 6.5W
LED MR16s supplied by Kenall (MR17WP only)
FS
Single Fuse & Holder
NAT
Natatorium Environment Option
QR
Quartz restrike system for maximum 100 Watt DC bay quartz
lamp (see 9009)
QRC
Hot/Cold Quartz restrike
QS
Quartz socket only
QS2
Two Quartz sockets (max. 50W ea.) (MR17WP only)
RAK
Remote Arc Keeper (100M lamp type only)
XAC*
Auxiliary Emergency Lighting (120V AC) (MR17NP only)
Accessories
BPC
Photo Control – Shielded Button Type
(120 or 277V only, 277 Volt n/a 150 HID)
9009
100 Watt DC Bay Quartz Lamp
50QL
50 Watt Candelabra Base Quartz Lamp
9500
Torx® Screwdriver
† UV shielding lamp supplied
* Configured to accommodate two emergency quartz lamps
(50W max). Lamps by others.
â–˛
n/a with BPC
• 12VDC Power to be supplied by others.
www.kenall.com
P: 800-4-Kenall
F: 262-891-9701
10200 55th Street Kenosha, Wisconsin 53144
When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy
American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found
at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.
MR17_NP_WP-110813
46
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
PROJECT INFORMATION
Job Name
MILLENIUM FINITE™
Fixture Type
FN15 SERIES – LOW PROFILE WITH EGRESS OPTICS
Catalog Number
PRODUCT FEATURES:
Approved by
» Surface wall mount – 9"H×15"W×12"D
» Full cut-off for IDA-approved Dark Sky installations
» High impact, UV-stabilized polycarbonate housing
» UL certified IP64 per IEC 60598
» Peace of Mind Guarantee® against breakage
SPECIFICATIONS
HOUSING: High-impact resistant, UV-stabilized injection molded polycarbonate. Ballast housing marine-grade die-cast aluminum construction.
DOOR: High-impact resistant, UV-stabilized injection molded polycarbonate with detachable hinge. Secured to housing with four (4) captive, recessed Torx® (or optional Phillips head) stainless steel
screws. Lens sealed with closed-cell silicone gasket and secured to door frame with heavy gauge stainless steel brackets.
GASKETING: Closed cell, silicone “O”ring gasket seals joint between polycarbonate housing and die-cast aluminum ballast housing and joint between polycarbonate housing and polycarbonate
lens frame assembly. Thick gauge, die-cut, closed cell neoprene with self-adhesive gasket seals joint between housing and mounting surface or accessory surface conduit adapter.
ELECTRICAL: Fluorescent electronic 120/277/347 and dual voltage ballasts high power factor (<10% THD), HID ballasts high power factor. Metal halide lamps utilize pulse start technology. Shock
absorbing, medium base lamp sockets provided for HID lamps. See Lamp Type for electronic metal halide ballast option. Two (2) 12V DC emergency auxiliary lamps provided (12VDC Power to be
supplied by others.) – see Egress Option in Ordering Information.
INSTALLATION: Fixture is factory pre-wired and includes gasketed, 16-gauge stainless steel quick mounting plate. Once four-point mounted to wall (required for Peace of Mind Guarantee®) or
accessory surface conduit adapter, allows quick mounting with hook-and-lock mechanism. Quick mounting plate bolts to wall (fasteners by other), fixture attaches to mounting plate with two (2)
captive Torx (or optional Phillips head) screws, which are concealed but accessible from bottom.
SURFACE CONDUIT ADAPTER (ACCESSORY): Marine-grade die-cast aluminum construction includes die-cut gaskets and two ¾" threaded connection ports. Once four-point mounted to wall
(required for Peace of Mind Guarantee®) allows same quick mounting (hook-and-lock) capability as described in the Installation section above.
LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. IESNA-designated full cut-off. IDA-Approved™ Dark-Sky Friendly Fixture.
IP64
ORDERING INFORMATION (Ex: FN15LAUX-2-A-MB-32P-1-DV-AUX20H-FS)
Model
FN15LAUX
Optic System
2
Optic System
2
Type II
Lens Type
A
.250" Clear Tempered Glass
Lens Type
Finish
Lamp Type
Lamp Qty
Voltage
Egress Options
Options
Accessories
A
Finish
MB Matte Black
MW Matte White
DB Dark Bronze
CC Custom Color (Consult factory)
Voltage
120
120 Volts
277
277 Volts
DV
120-277 Volts (CFL only)
347
347 Volts
Lamp Type
(Type/Quantity/Ballast/Volt,/Starting Temp)
26P
26 Watt PLT (1,2/RS/120,277,347/0°F)
32P
32 Watt PLT (1,2/RS/120,277,347/0°F)
50M 50 Watt MH (1/HPF/120,277,347/-20°F)
50S
50 Watt HPS (1/HPF/120,277,347/-40°F)
70M 70 Watt MH (1/HPF/120,277,347/-20°F)
70ME 70 Watt MH (1/EB/120,277/-20°F)
70S
70 Watt HPS (1/HPF/120,277,347/-40°F)
Egress Options
AUX20H* Low Voltage Emergency Auxiliary Lamp (12VDC) w/(2) 20W Halogen
MR16 lamps supplied by Kenall
AUX6.5L* Low Voltage Emergency Auxiliary Lamp (12VDC) w/(2) 6.5W LED
MR16s supplied by Kenall
Lamp Quantity
1
One Lamp
2
Two Lamps (CFL only)
www.kenall.com
P: 800-4-Kenall
*12VDC Power to be supplied by others.
Options
FS
Single Fuse & Holder
PH
Phillips Head Fasteners
Accessory
SA
Die-Cast Surface Adapter
F: 262-891-9701
10200 55th Street Kenosha, Wisconsin 53144
When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy
American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found
at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.
FN15LAUX-100913
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
47
47
PROJECT INFORMATION
Job Name
MILLENIUM FINITE™
Fixture Type
FN SERIES – DEEP PROFILE WITH EGRESS OPTICS
Catalog Number
Approved by
PRODUCT FEATURES:
» Surface wall mount – 15"W×9"H×13"D
» Full cut-off for IDA-approved Dark Sky installations
» High impact, UV-stabilized polycarbonate housing
» UL certified IP64 per IEC 60598
» Peace of Mind Guarantee® against breakage
SPECIFICATIONS
HOUSING: High-impact resistant, UV-stabilized injection molded polycarbonate. Ballast housing marine-grade die-cast aluminum construction.
DOOR: High-impact resistant, UV-stabilized injection molded polycarbonate with detachable hinge. Secured to housing with four (4) captive, recessed Torx® with center pin (or optional Phillips head)
stainless steel screws. Lens sealed with closed-cell silicone gasket and secured to door frame with heavy gauge stainless steel brackets.
GASKETING: Closed cell, silicone “O”ring gasket seals joint between polycarbonate housing and die-cast aluminum ballast housing and joint between polycarbonate housing and polycarbonate
lens frame assembly. Thick gauge, die-cut, closed cell neoprene with self-adhesive gasket seals joint between housing and mounting surface or accessory surface conduit adapter.
ELECTRICAL: Fluorescent electronic 120/277/347 and dual voltage ballasts high power factor (<10% THD), HID ballasts high power factor. Metal halide lamps utilize pulse start technology.
Shock absorbing, medium base lamp sockets provided for HID lamps. Two (2) 12V DC emergency auxiliary lamps provided (12VDC Power to be supplied by others.) – see Egress Option in Ordering
Information.
INSTALLATION: Fixture is factory pre-wired and includes gasketed, 16-gauge stainless steel quick mounting plate. Once four-point mounted to wall (required for Peace of Mind Guarantee®) or
accessory surface conduit adapter, allows quick mounting with hook-and-lock mechanism. Quick mounting plate bolts to wall (fasteners by other), fixture attaches to mounting plate with two (2)
captive Torx® with center pin (or optional Phillips head) screws, which are concealed but accessible from bottom.
SURFACE CONDUIT ADAPTER (ACCESSORY): Marine-grade die-cast aluminum construction includes die-cut gaskets and two ¾" threaded connection ports. Once four-point mounted to wall
(required for Peace of Mind Guarantee®) allows same quick mounting (hook-and-lock) capability as described in the Installation section above.
LISTINGS: UL and CUL listed for Wet Location. UL certified IP64 per IEC 60598. IESNA-designated full cut-off. IDA-Approved™ Dark-Sky Friendly Fixture.
IP64
ORDERING INFORMATION (Ex: FN15DAUX-2-A-MB-32P-1-DV)
Model
FN15DAUX
Optic System
Lens Type
2
A
Optic System
2
Type II
Lens Type
A
.250" Clear Tempered Glass
Finish
Lamp Type
Lamp Qty
Finish
MB Matte Black
MW Matte White
DB Dark Bronze
CC Custom Color Consult factory)
Lamp (Type/Qty/Ballast/Volt./Starting Temp)
26P
26 Watt PLT (1,2/RS/120,277,347/0°F)
32P
32 Watt PLT (1,2/RS/120,277,347/0°F)
100M 100 Watt MH (1/HPF/120,277,347/-20°F)
100ME 100 Watt MH (1/EB/120,277/-20°F)
100S 100 Watt HPS (1/HPF/120,277,347/-40°F)
150M 150 Watt MH (1/CWA/120,277,347/-20°F)
150S 150 Watt HPS (1/HPF/120,277,347/-40°F)
Voltage
Options
Accessories
Voltage
120
120 Volts
277
277 Volts
DV
120-277 Volts
(CFL only)
347
347 Volts
Options
AUX20H* Low Voltage Emergency Auxiliary Lamp
(12VDC) w/(2) 20W Halogen MR16
lamps supplied by Kenall
AUX6.5L* Low Voltage Emergency Auxiliary Lamp
(12VDC) w/(2) 6.5W LED MR16s
supplied by Kenall
FS
Single Fuse & Holder
PH
Phillips Head Fastener
*12VDC Power to be supplied by others.
Accessory
SA
Die-Cast Surface Adapter
Lamp Quantity
1
One Lamp
2
Two Lamps (CFL only)
www.kenall.com
P: 800-4-Kenall
F: 262-891-9701
10200 55th Street Kenosha, Wisconsin 53144
When you see this image, you will know the Kenall product shown or described is designed and manufactured in the USA with components purchased from US suppliers, and meets the Buy
American requirements under the ARRA. Kenall has not determined the origin of its domestically purchased components or the subcomponents thereof. May be covered by patents found
at www.kenall.com/patents. Content of specification sheets is subject to change; please consult www.kenall.com for current product details. © 2015 Kenall Mfg. Co. All rights reserved.
FN15DAUX-100913
48
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
NFPA Life Safety Code
Excerpt: Illumination of Means of Egress
7.8 Illumination of Means of Egress.
7.8.1 General.
7.8.1.1* Illumination of means of egress shall be provided in
accordance with Section 7.8 for every building and structure where
required in Chapters 11 through 43. For the purposes of this
requirement, exit access shall include only designated stairs, aisles,
corridors, ramps, escalators, and passageways leading to an exit.
For the purposes of this requirement, exit discharge shall include only
designated stairs, aisles, corridors, ramps, escalators, walkways, and
exit passageways leading to a public way.
7.8.1.2 Illumination of means of egress shall be continuous during
the time that the conditions of occupancy require that the means of
egress be available for use, unless otherwise provided in 7.8.1.2.2.
7.8.1.2.1 Artificial lighting shall be employed at such locations and for
such periods of time as are necessary to maintain the illumination to
the minimum criteria values herein specified.
7.8.1.2.2 Automatic, motion sensor–type lighting switches shall
be permitted within the means of egress, provided that the switch
controllers are equipped for fail-safe operation, the illumination timers
are set for a minimum 15-minute duration, and the motion sensor is
activated by any 7.8.1.3* The floors and other walking surfaces within
an exit and within the portions of the exit access and exit discharge
designated in 7.8.1.1 shall be illuminated as follows:
Life Safety Code® and 101® are registered trademarks
of the National Fire Protection Association, Quincy, MA.
(b) The standby generator shall be permitted to be used for
the stair shaft and vestibule emergency lighting power supply.
(6) New access-controlled egress doors in accordance with
7.2.1.6.2.
7.9.1.2 For the purposes of 7.9.1.1, exit access shall include only
designated stairs, aisles, corridors, ramps, escalators, and
passageways leading to an exit. For the purposes of 7.9.1.1, exit
discharge shall include only designated stairs, ramps, aisles,
walkways, and escalators leading to a public way.
7.9.1.3 Where maintenance of illumination depends on changing from
one energy source to another, a delay of not more than 10 seconds
shall be permitted.
7.9.2 Performance of System.
7.9.2.1* Emergency illumination shall be provided for a minimum
of 11⁄2 hours in the event of failure of normal lighting. Emergency
lighting facilities shall be arranged to provide initial illumination that
is not less than an average of 1 footcandle (10.8 lux) and, at any point,
not less than 0.1 footcandle (1.1 lux), measured along the path of
egress at floor level. Illumination levels shall be permitted to decline
to not less than an average of 0.6 footcandle (6.5 lux) and, at any
point, not less than 0.06 footcandle (0.65 lux) at the end of 11⁄2 hours.
A maximum-to-minimum illumination uniformity ratio of 40 to 1 shall
not be exceeded.
(1) During conditions of stair use, the minimum illumination for
new stairs shall be at least 10 footcandle (108 lux), measured at
the walking surfaces.
7.9.2.2 New emergency power systems for emergency lighting shall
be at least Type 10, Class 1.5, Level 1, in accordance with NFPA110,
Standard for Emergency and Standby Power Systems.
(2) The minimum illumination for floors and walking surfaces, other
than new stairs during conditions of stair use, shall be to values of
at least 1 footcandle (10.8 lux), measured at the floor.
7.9.2.3* The emergency lighting system shall be arranged to provide
the required illumination automatically in the event of any interruption
of normal lighting due to any of the following:
(3) In assembly occupancies, the illumination of the walking surfaces
of exit access shall be at least 0.2 footcandle (2.2 lux) during
periods of performances or projections involving directed light.
(4)*The minimum illumination requirements shall not apply where
operations or processes require low lighting levels.
7.8.1.4* Required illumination shall be arranged so that the failure of
any single lighting unit does not result in an illumination level of less
than 0.2 footcandle (2.2 lux) in any designated area.
7.8.1.5 The equipment or units installed to meet the requirements
of Section 7.10 also shall be permitted to serve the function of
illumination of means of egress, provided that all requirements of
Section 7.8 for such illumination are met.
7.8.2 Sources of Illumination.
7.8.2.1* Illumination of means of egress shall be from a source
considered reliable by the authority having jurisdiction.
7.8.2.2 Battery-operated electric lights and other types of portable
lamps or lanterns shall not be used for primary illumination of means
of egress. Battery-operated electric lights shall be permitted to be
used as an emergency source to the extent permitted under Sec, 7.9.
7.9 Emergency Lighting.
7.9.1 General.
7.9.1.1* Emergency lighting facilities for means of egress shall be
provided in accordance with Section 7.9 for the following:
(1) Buildings or structures where required in Chapters 11–43
(2) Underground and limited access structures as addressed in
Section 11.7
(3) High-rise buildings as required by other sections of this Code
(4) Doors equipped with delayed-egress locks
(5) Stair shaft and vestibule of smokeproof enclosures, for which
the following also apply:
(a) The stair shaft and vestibule shall be permitted to include a
standby generator that is installed for the smokeproof enclosure
mechanical ventilation equipment.
(1) Failure of a public utility or other outside electrical power supply
(2) Opening of a circuit breaker or fuse
(3) Manual act(s), including accidental opening of a switch
controlling normal lighting facilities
7.9.2.4 Emergency generators providing power to emergency lighting
systems shall be installed, tested, and maintained in accordance with
NFPA 110, Standard for Emergency and Standby Power Systems.
Stored electrical energy systems, where required in this Code, other
than battery systems for emergency luminaires in accordance with
7.9.2.5, shall be installed and tested in accordance with NFPA 111,
Standard on Stored Electrical Energy Emergency and Standby Power
Systems.
7.9.2.5 Unit equipment and battery systems for emergency
luminaires shall be listed to ANSI/UL 924, Standard for Emergency
Lighting and Power Equipment.
7.9.2.6* Existing battery-operated emergency lights shall use only
reliable types of rechargeable batteries provided with suitable
facilities for maintaining them in properly charged condition. Batteries
used in such lights or units shall be approved for their intended use
and shall comply with NFPA 70, National Electrical Code.
7.9.2.7 The emergency lighting system shall be either continuously in
operation or shall be capable of repeated automatic operation without
manual intervention.
7.9.3 Periodic Testing of Emergency Lighting Equipment.
7.9.3.1 Required emergency lighting systems shall be tested in
accordance with one of the three options offered by 7.9.3.1.1,
7.9.3.1.2, or 7.9.3.1.3.
7.9.3.1.1 Testing of required emergency lighting systems shall be
permitted to be conducted as follows:
(1) Functional testing shall be conducted monthly with a minimum
of 3 weeks and a maximum of 5 weeks between tests, for not less
than 30 seconds, except as otherwise permitted by 7.9.3.1.1(2).
101–76 LIFE SAFETY CODE
(2)*The test interval shall be permitted to be extended beyond 30
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
49
49
NFPA Life Safety Code
Excerpt: Illumination of Means of Egress
days with the approval of the authority having jurisdiction.
7.10.1.5 Exit Access.
(3) Functional testing shall be conducted annually for a minimum of
11⁄2 hours if the emergency lighting system is battery powered.
7.10.1.5.1 Access to exits shall be marked by approved, readily visible
signs in all cases where the exit or way to reach the exit is not readily
apparent to the occupants.
(4) The emergency lighting equipment shall be fully operational for
the duration of the tests required by 7.9.3.1.1(1) and (3).
(5) Written records of visual inspections and tests shall be kept by
the owner for inspection by the authority having jurisdiction.
7.9.3.1.2 Testing of required emergency lighting systems shall be
permitted to be conducted as follows:
(1) Self-testing/self-diagnostic battery-operated emergency lighting
equipment shall be provided.
(2) Not less than once every 30 days, self-testing/self-diagnostic
battery-operated emergency lighting equipment shall automatically
perform a test with a duration of a minimum of 30 seconds and a
diagnostic routine.
(3) Self-testing/self-diagnostic battery-operated emergency lighting
equipment shall indicate failures by a status indicator.
(4) A visual inspection shall be performed at intervals not exceeding
30 days.
(5) Functional testing shall be conducted annually for a minimum of
11⁄2 hours.
(6) Self-testing/self-diagnostic battery-operated emergency lighting
equipment shall be fully operational for the duration of the 11⁄2
hour test.
(7) Written records of visual inspections and tests shall be kept by
the owner for inspection by the authority having jurisdiction.
7.9.3.1.3 Testing of required emergency lighting systems shall be
permitted to be conducted as follows:
(1) Computer-based, self-testing/self-diagnostic battery operated
emergency lighting equipment shall be provided.
(2) Not less than once every 30 days, emergency lighting
equipment shall automatically perform a test with a duration of
a minimum of 30 seconds and a diagnostic routine.
(3) The emergency lighting equipment shall automatically perform
annually a test for a minimum of 11⁄2 hours.
(4) The emergency lighting equipment shall be fully operational for
the duration of the tests required by 7.9.3.1.3(2) and (3).
(5) The computer-based system shall be capable of providing a
report of the history of tests and failures at all times.
7.10 Marking of Means of Egress.
7.10.1 General.
7.10.1.1 Where Required. Means of egress shall be marked in
accordance with Section 7.10 where required in Chapters 11 through 43.
7.10.1.2 Exits.
7.10.1.2.1* Exits, other than main exterior exit doors that obviously
and clearly are identifiable as exits, shall be marked by an approved
sign that is readily visible from any direction of exit access.
7.10.1.2.2* Horizontal components of the egress path within an exit
enclosure shall be marked by approved exit or directional exit signs
where the continuation of the egress path is not obvious.
7.10.1.3 Exit Door Tactile Signage. Tactile signage shall be provided to
meet the following criteria, unless otherwise provided in 7.10.1.4:
(1) Tactile signage shall be located at each exit door requiring an
exit sign.
(2) Tactile signage shall read as follows: EXIT.
(3) Tactile signage shall comply with ICC/ANSI A117.1,
American National Standard for Accessible and Usable Buildings
and Facilities.
7.10.1.4 Existing Exemption. The requirements of 7.10.1.3 shall not
apply to existing buildings, provided that the occupancy classification
does not change.
50
7.10.1.5.2* New sign placement shall be such that no point in an exit
access corridor is in excess of the rated viewing distance or 100 ft
(30 m), whichever is less, from the nearest sign.
7.10.1.6* Floor Proximity Exit Signs. Where floor proximity exit signs
are required in Chapters 11 through 43, such signs shall comply with
7.10.3, 7.10.4, 7.10.5, and 7.10.6 for externally illuminated signs and
7.10.7 for internally illuminated signs. Such signs shall be located near
the floor level in addition to those signs required for doors or
corridors. The bottom of the sign shall be not less than 6 in. (150mm),
but not more than 18 in. (455 mm), above the floor. For exit doors, the
sign shall be mounted on the door or adjacent to the door, with the
nearest edge of the sign within 4 in. (100 mm) of the door frame.
7.10.1.7* Floor Proximity Egress Path Marking. Where floor
proximity egress path marking is required in Chapters 11 through
43, an approved floor proximity egress path marking system that is
internally illuminated shall be installed within 18 in. (455 mm) of the
floor. Floor proximity egress path marking systems shall be listed in
accordance with ANSI/UL 1994, Standard for Luminous Egress Path
Marking Systems. The system shall provide a visible delineation of
the path of travel along the designated exit access and shall be
essentially continuous, except as interrupted by doorways, hallways,
corridors, or other such architectural features. The system shall
operate continuously or at any time the building fire alarm system is
activated. The activation, duration, and continuity of operation of the
system shall be in accordance with 7.9.2. The system shall be
maintained in accordance with the product manufacturing listing.
7.10.1.8* Visibility. Every sign required in Section 7.10 shall be
located and of such size, distinctive color, and design that it is readily
visible and shall provide contrast with decorations, interior finish, or
other signs. No decorations, furnishings, or equipment that impairs
visibility of a sign shall be permitted. No brightly illuminated sign (for
other than exit purposes), display, or object in or near the line of vision
of the required exit sign that could detract attention from the exit sign
shall be permitted.
7.10.1.9 Mounting Location. The bottom of new egress markings
shall be located at a vertical distance of not more than 6 ft. 8 in.
(2030 mm) above the top edge of the egress opening intended for
designation by that marking. Egress markings shall be located at a
horizontal distance of not more than the required width of the egress
opening, as measured from the edge of the egress opening intended
for designation by that marking to the nearest edge of the marking.
7.10.2 Directional Signs.
7.10.2.1* A sign complying with 7.10.3 with a directional indicator
showing the direction of travel shall be placed in every location where
the direction of travel to reach the nearest exit is not apparent.
7.10.2.2 Directional exit signs shall be provided within horizontal
components of the egress path within exit enclosures as required by
7.10.1.2.2.
7.10.3* Sign Legend.
7.10.3.1 Signs required by 7.10.1 and 7.10.2 shall read as follows in
plainly legible letters, or other appropriate wording shall be used:
EXIT
7.10.3.2* Where approved by the authority having jurisdiction,
pictograms in compliance with NFPA 170, Standard for Fire Safety
and Emergency Symbols, shall be permitted.
7.10.4* Power Source. Where emergency lighting facilities are
required by the applicable provisions of Chapters 11 through 43 for
individual occupancies, the signs, other than approved self-luminous
signs and listed photoluminescent signs in accordance with 7.10.7.2,
shall be illuminated by the emergency lighting facilities. The level of
illumination of the signs shall be in accordance with 7.10.6.3 or 7.10.7
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
NFPA Life Safety Code
Excerpt: Illumination of Means of Egress
for the required emergency lighting duration as specified in 7.9.2.1.
However, the level of illumination shall be permitted to decline to 60
percent at the end of the emergency lighting duration.
7.10.7.1 Listing. Internally illuminated signs shall be listed in
accordance with ANSI/UL 924, Standard for Emergency Lighting and
Power Equipment, unless they meet one of the following criteria:
7.10.5 Illumination of Signs.
(1) They are approved existing signs.
7.10.5.1* General. Every sign required by 7.10.1.2, 7.10.1.5, or
(2) They are existing signs having the required wording in legible
letters not less than 4 in. (100 mm) high.
7.10.8.1, other than where operations or processes require low lighting
levels, shall be suitably illuminated by a reliable light source. Externally
and internally illuminated signs shall be legible in both the normal and
emergency lighting mode.
7.10.5.2* Continuous Illumination.
7.10.5.2.1 Every sign required to be illuminated by 7.10.6.3, 7.10.7,
and 7.10.8.1 shall be continuously illuminated as required under the
provisions of Section 7.8, unless otherwise provided in 7.10.5.2.2.
7.10.5.2.2* Illumination for signs shall be permitted to flash on and off
upon activation of the fire alarm system.
7.10.6 Externally Illuminated Signs.
7.10.6.1* Size of Signs.
7.10.6.1.1 Externally illuminated signs required by 7.10.1 and 7.10.2,
other than approved existing signs, unless otherwise provided in
7.10.6.1.2, shall read EXIT or shall use other appropriate wording in
plainly legible letters sized as follows:
(1) For new signs, the letters shall be not less than 6 in. (150 mm)
high, with the principal strokes of letters not less than 3⁄4 in. (19
mm) wide.
(2) For existing signs, the required wording shall be permitted
to be in plainly legible letters not less than 4 in. (100 mm) high.
(3) The word EXIT shall be in letters of a width not less than 2 in.
(51 mm), except the letter I, and the minimum spacing between
letters shall be not less than 3⁄8 in. (9.5 mm).
(4) Sign legend elements larger than the minimum established in
7.10.6.1.1(1) through (3) shall use letter widths, strokes, and
spacing in proportion to their height.
7.10.6.1.2 The requirements of 7.10.6.1.1 shall not apply to
marking required by 7.10.1.3 and 7.10.1.7. 7.10.6.2* Size and
Location of Directional Indicator.
7.10.6.2.1 Directional indicators, unless otherwise provided in
7.10.6.2.2, shall comply with the following:
(3) They are signs that are in accordance with 7.10.1.3 and 7.10.1.6.
7.10.7.2* Photoluminescent Signs. The face of a photoluminescent
sign shall be continually illuminated while the building is occupied.
The illumination levels on the face of the photoluminescent sign shall
be in accordance with its listing. The charging illumination shall be a
reliable light source, as determined by the authority having jurisdiction.
The charging light source, shall be of a type specified in the product
markings. 7.10.8 Special Signs.
7.10.8.1 Sign Illumination.
7.10.8.1.1 Where required by other provisions of this Code, special
signs shall be illuminated in accordance with 7.10.5, 7.10.6.3, and
7.10.7.
7.10.8.1.2 Where emergency lighting facilities are required by the
applicable provisions of Chapters 11 through 43, the required
illumination of special signs shall additionally be provided under
emergency lighting conditions.
7.10.8.2 Characters. Special signs, where required by other provisions
of this Code, shall comply with the visual character requirements
of ICC/ANSI A117.1, American National Standard for Accessible and
Usable Buildings and Facilities.
7.10.8.3* No Exit.
7.10.8.3.1 Any door, passage, or stairway that is neither an exit nor
a way of exit access and that is located or arranged so that it is likely
to be mistaken for an exit shall be identified by a sign that reads as
follows:
NO
EXIT
7.10.8.3.2 The NO EXIT sign shall have the word NO in letters 2 in.
(51 mm) high, with a stroke width of 3⁄8 in. (9.5 mm), and the word
EXIT in letters 1 in. (25 mm) high, with the word EXIT below the word
NO, unless such sign is an approved existing sign.
(1) The directional indicator shall be located outside of the EXIT
legend, not less than 3⁄8 in. (9.5 mm) from any letter.
7.10.8.4 Elevator Signs. Elevators that are a part of a means of egress
(see 7.2.13.1) shall have the following signs with a minimum letter
height of 5⁄8 in. (16 mm) posted in every elevator lobby:
(2) The directional indicator shall be of a chevron type, as shown
in Figure 7.10.6.2.1.
(1)*Signs that indicate that the elevator can be used for egress,
including any restrictions on use
(3) The directional indicator shall be identifiable as a directional
indicator at a distance of 40 ft (12 m).
(2)*Signs that indicate the operational status of elevators
(4) A directional indicator larger than the minimum established for
compliance with 7.10.6.2.1(3) shall be proportionately increased in
height, width, and stroke.
(5) The directional indicator shall be located at the end of the sign
for the direction indicated.
7.10.8.5* Evacuation Diagram. Where a posted floor evacuation
diagram is required in Chapters 11 through 43, floor evacuation
diagrams reflecting the actual floor arrangement and exit locations
shall be posted and oriented in a location and manner acceptable to the
authority having jurisdiction.
7.10.9 Testing and Maintenance.
7.10.9.1 Inspection. Exit signs shall be visually inspected for operation
of the illumination sources at intervals not to exceed 30 days or shall
be periodically monitored in accordance with 7.9.3.1.3.
FIGURE 7.10.6.2.1 Chevron-Type Indicator
7.10.6.2.2 The requirements of 7.10.6.2.1 shall not apply to approved
existing signs.
7.10.6.3* Level of Illumination. Externally illuminated signs shall be
illuminated by not less than 5 footcandles (54 lux) at the illuminated
surface and shall have a contrast ratio of not less than 0.5.
7.10.9.2 Testing. Exit signs connected to, or provided with, a
battery-operated emergency illumination source, where required in
7.10.4, shall be tested and maintained in accordance with 7.9.3.
Reprinted with permission from NFPA 101®, The Life Safety Code®,
copyright © 2008, National Fire Protection Association. This reprinted
material is not the complete and official position of the NFPA on the
referenced subject which is represented solely b the standard in its entirety.
7.10.7 Internally Illuminated Signs.
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
51
51
TECHNICAL SPECIFICATIONS
Remote Lamp Voltage Drop Table
Refer to the data below to specify wire size appropriate for
the distance of run needed for your project. Wire Size
Total watts
#12
#10
#8
#6
#4
on
wire run
Length of Wire Run (Feet)
9
236 376600 9251516
18
118 188300 476 758
20
106 169270 429 683
24
89 141225 357 569
27
78 125200 317 505
36
5994
150238379
40
5384
135214341
45
4775
120190303
48
4470
112178284
Constant
2137 3397 5403 8590 13660
12 Volt System
Maximum Voltage Drop 5%
To determine the maximum length of a wire run not listed,
divide the constant listed at the bottom of each column by
the value of load in watts. Example: The maximum wire run
for #12 wire with a 117 watt load is 2137/117=18 feet.
To determine the maximum load on a wire run known length,
divide the constant listed at the bottom of each column by
the length of the run in feet. Example: The maximum load for
a 36 foot run of #10 wire is 3397/36=94 watts.
Multipliers for Equally Sized,
Equally spaced Loads
Number of luminaires 2
3
Multiply distance by 1.33 1.50
4
5
1.60 1.67
6
1.71
Maximum Voltage Drop 5%
Remote Exit Voltage Drop Table
Refer to the data below to specify wire size appropriate
for the distance of run needed for your project.
Wire Size #18 #16 #14 #12 #10 #8
Length of Wire Run (Feet)
1 sign on wire run89141227 361574914
2
signs on wire run44 70 113 180 287 457
EMERGENCY BATTERY PACK SELECTION GUIDE
This guide provides the ordering designation for each of
the standard battery packs used in Kenall luminaires.
T8 Lamps
EL Standard Emergency Battery pack (500-600 lumens)
PELHigh Lumen Emergency Battery pack (1350 lumens)
SEL Specified Emergency Battery pack
RELRemote-ready Emergency Battery pack ( ** )
T5 and T5HO Lamps
EL Standard Emergency Battery pack (700 lumens)
PELHigh Lumen Emergency Battery pack (1250 lumens)
SEL Specified Emergency Battery pack
RELRemote-ready Emergency Battery pack ( ** )
Hazardous Locations for T8, T5 and T5HO Lamps
HEL Standard Emergency Battery pack (300-700 lumens)
Compact Fluorescent Lamps
EL Standard Emergency Battery pack (300-750 lumens)
SEL Specified Emergency Battery pack
RELRemote-ready Emergency Battery pack ( ** )
(**consult factory)
Note: Two-lamp redundancy mode requires two one-lamp
ballasts combined with two-lamp emergency battery backup.
In cases where there is not enough room in the luminaire to
house all components, remote battery backup is necessary.
Consult factory for remote battery backups which require
special wiring and installation instructions per application.
Lumen Chart for
Compact Fluorescent Lamps
(Initial Lumens for 4-Pin Lamps)
Lumens
Lamp Prefix
One-LampTwo -Lamps
PL13
350425
PL18
300525
PL26
450725
PLT26
450725
PLT32
575750
PLT42
750
n/a
Note: All emergency battery packs for T8, T5, and T5HO
lamps will be wired to one-lamp unless otherwise specified.
4 Volt System Maximum Voltage Drop 5%
Battery Output Rating
The information below illustrates the duration available with
each battery and lamp wattage option.
Battery *1/2 hr. *1 hr. 1 1/2 hr. 2 hrs. 3 hrs. 4 hrs.
24N 48W 32W 24W18W12W9W
40N 80W 53W 40W30W20W
15W
48N 96W 64W 48W36W24W
18W
80N 160W106W 80W60W40W
30W
*per Canadian code
52
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
K230 performance
PERFORMANCE standards
STANDARD
K230
for Luminaire Leakage in Pressurized Environments
Large numbers of R&D, high-tech manufacturing and medical
facilities contain areas in which environmental isolation and the
prevention of cross-contamination are critical. Applications such as
cleanrooms, research labs and surgical suites must be kept free of
external contaminants while others, such as infectious disease
isolation areas and R&D bio-containment spaces, must prevent
contaminants from escaping.
The need for environmental isolation in these areas is so critical
that air pressure is used as a buffer against contamination. Positive
pressure is employed where the introduction of foreign matter
causes contamination, while negative pressure creates a barrier to
contaminant egress where containment is the critical issue.
When anything – including a lighting fixture – penetrates the ceiling,
it creates the potential for contaminant leakage. Consequently,
luminaires must be free of openings through which contaminants
can pass or that could result in a reduction of pressure. Simply put,
a key performance requirement for lighting fixtures in pressurized
environments is the ability to prevent leakage.
Testing by a qualified laboratory, utilizing the K230 testing protocol,
is the best way available to ensure compliance levels comparable to
those required by the NSF49 standard, Section 6.2, because K230
procedures are based on those prescribed by NSF49 for biosafety
cabinetry. Thus, Kenall’s K230 determines a fixture’s ability to
restrict the passage or penetration of contaminants when subjected
to prescribed pressure level in either positive or negative pressure
environments. In short, it measures a fixture’s resistance to leakage
in virtually any pressurized environment.
Kenall’s K230 test, performed under controlled conditions by
a highly qualified independent testing lab, calls for a special airtight
chamber containing a pressure plenum fabricated to simulate the
type of ceiling surface to which the fixture will be mounted. The
plenum is then pressurized to the prescribed level and sealed,
with pressure readings recorded on a water gauge at five minute
intervals. To meet the K230 leakage prevention standard, the fixture
must be able to maintain two inches of pressure, plus or minus
10 percent, for 30 minutes.
Leakage Prevention
Responding to the growing needs for increasingly more effective
techniques of containing dangerous organisms, standards for
bio-containment cabinets have rapidly advanced in recent years.
These cabinets employ negatively pressurized interiors to maximize
containment. To this end, they must be free of holes, gaps, or other
openings that could allow leakage and thereby compromise the
effectiveness of the cabinet’s pressure-based contamination barrier.
From this perspective, lighting fixtures used in larger negative
pressure environments to seal off ceiling enclosures have leakagebased performance requirements very similar to those of
bio-containment cabinets.
There is no mandatory U.S. standard specific to luminaire leakage
in pressurized applications. However, there is a widely accepted
leakage standard for cabinetry developed by the National Sanitation
Foundation (NSF) in conjunction with the American National
Standards Institute (ANSI): NSF49 Class II (laminar flow) Biosafety
Cabinetry. Section 6.2 of that standard, Pressure Decay/Soap
Bubble/Tracer Gas Leak can be effectively adapted to the testing
of light fixtures. Kenall refers to its proprietary adaptation as the
K230 Performance Standard for Luminaire Leakage in Pressurized
Environments.
LIGHT FIXTURE
PLENUM
Pressure Tested
Gauge
Pressure in
Fabricated plenum designed to test
Kenall luminiares for pressured leaks.
Hospitals
Hospitals and other healthcare facilities contain areas where patients
infected with or tested for highly contagious or communicable
diseases, are isolated for observation and treatment. They contain
a variety of areas, including surgical suites, patient rooms and ICUs,
that use positive pressure as a barrier against contaminant ingress,
particularly dangerous pathogens. Fixtures complying with Kenall’s
K230 pressure testing standard are able to meet or exceed the
leakage prevention requirements for these applications – for both
contaminant ingress and the maintenance of target pressure levels.
Cleanroom spaces are defined by their level of cleanliness, so these
spaces require lighting fixtures capable of supporting the highest
levels of environmental integrity related to the passage or production
of airborne particles. Only by selecting a fixture that has been tested
to accepted standards, can the specifier be confident that the fixture
is free of gaps or holes through which contaminants can enter a
controlled space, and does not itself produce objectionable levels of
particulate contamination.
K230
When you see this symbol
you'll know the Kenall luminaire has
been tested and certified to the K230
standard
www. kenall.com
P: 800-4-Kenall
F: 847-360-1781
1020 Lakeside Drive Gurnee, Illinois 60031
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
53
53
NSF
NATIONAL SANITATION FOUNDATION
Fixtures for use in Food Processing, Handling & Preparation
NATIONAL SANITATION FOUNDATION and IP LISTINGS
Kenall lighting fixtures for use in food processing, handling and
Food Zones
The higher le
Zone/Non-Fo
located in fo
NSF2
in contact w
NSF
NATIONALSANITATION
SANITATIONFOUNDATION
FOUNDATIONThe purpose of criteria C2 is to insure that equipment located in a
NSF NATIONAL
sheet metal
Luminaires for use in Food Processing, Handling & Preparation
aluminum. P
food storage, handling, or preparation area will not compromise the
Title 21 to b
requirements
Fixtures
Food
(FN)
Fixturesfor
foruse
useininFood
FoodProcessing,
Processing,Handling
Handling&&Preparation
Preparation sanitation
FoodZones
Zones
(FN) for those areas. Equipment listed to criteria
steel and rem
C2 has been evaluated as to its corrosion resistance, cleanability and
The
higher
level
ofofconstruction
isisour
FNFNtype
construction
for
Food
Kenall
Kenalllighting
lightingfixtures
fixturesfor
foruse
useininfood
foodprocessing,
processing,handling
handlingand
and
The
higher
level
construction
our
type
construction
for
Food
and the oute
exposed material.
Zone/Non-Food
preparation
preparationareas
areashave
havebeen
beeninvestigated
investigatedand
andlisted
listedbybythe
theNational
National
Zone/Non-FoodContact.
Contact.Fixtures
Fixturesininthis
thiscategory
categoryare
arephysically
physically
polycarbona
cally,inin
exposed
materials and
shall
withstand
normal
the
located
food
but
dodonot
come
Sanitation
SanitationFoundation
Foundation(NSF)
(NSF)asasconforming
conformingtotothe
therequirements
requirementsinin Specifi
located
foodpreparation
preparation
andhandling
handlingareas
areas
butwear,
not
come
Kenall canno
corrosive
action
ofthe
foods,
beverages,
and conditions.
cleaning
compounds,
inincontact
with
under
AllAllexposed
their
theircriteria
criteriaC2.
C2.
contact
with
thefood
food
undernormal
normal
conditions.
exposed
your specific
and
the
material
itself
shall
not
impart
an
odor,
color,
taste
or
toxic
sheet
metal
will
be
painted
CRS,
painted
aluminum,
or
anodized
sheet metal will be painted CRS, painted aluminum, or anodized
The
Thepurpose
purposeofofcriteria
criteriaC2
C2isistotoinsure
insurethat
thatequipment
equipmentlocated
locatedinina a material
inspector.
to
any
food
that
would
come
in
contact
with
it.
aluminum.
aluminum.Paint
Paintmust
mustmeet
meetU.S.
U.S.Code
CodeofofFederal
FederalRegulations,
Regulations,
food
foodstorage,
storage,handling,
handling,ororpreparation
preparationarea
areawill
willnot
notcompromise
compromisethe
the
Title
21
to
be
used
in
this
application.
Fasteners
will
be
stainless
NSF
defines
the surfaces
of equipment
as Food
Titlethis
21 category,
to be used
in this
application.
Fasteners
will be stainless
sanitation
sanitationrequirements
requirementsfor
forthose
thoseareas.
areas.Equipment
Equipmentlisted
listedtotocriteria
criteria Within
steel
removable
without
the
(thumbscrew
or
Non-Food
Contact
surfaces.
Food
Contact
surfacestype)
are
steeland
and
removable
without
theuse
useof
ofa atool
tool
(thumbscrew
type)
C2
C2has
hasbeen
beenevaluated
evaluatedasastotoitsitscorrosion
corrosionresistance,
resistance,cleanability
cleanabilityand
and Contact
and
the
outer
exposed
lens
must
bebeanan
FDA
approved
Food
Grade
further
divided
into
areas
as
Food
Zone,
Splash
Zone,
and
Non-Food
and
the
outer
exposed
lens
must
FDA
approved
Food
Grade
exposed
material.
exposed material.
polycarbonate
material.
Zone,
with Food Zone
requirements being the most stringent and
polycarbonate
material.
Specifi
cally,
exposed
materials
shall
withstand
normal
wear,
the
Specifically, exposed materials shall withstand normal wear, the
Non-Food
Zone being
the least
stringent.
Aofconstruction
subcategory
ofissuitable
Food
Kenall
recommend
which
level
Kenallcannot
cannot
recommend
which
levelof
constructionis
suitablefor
for
corrosive
corrosiveaction
actionofoffoods,
foods,beverages,
beverages,and
andcleaning
cleaningcompounds,
compounds,
Zone
equipment
is Non-Contact,
i.e.
equipment
in
the
Food
Zone,
your
specifi
c capplication
asasthe
final
decision
will
rest
with
the
your
specifi
application
the
fi
nal
decision
will
rest
with
thelocal
local
and
the
material
itself
shall
not
impart
an
odor,
color,
taste
or
toxic
and the material itself shall not impart an odor, color, taste or toxic but not normally in contact with the food.
inspector.
inspector.
material
materialtotoany
anyfood
foodthat
thatwould
wouldcome
comeinincontact
contactwith
withit.it.
preparation areas have been investigated and listed by the National
Sanitation Foundation (NSF) as conforming to the requirements in
their criteria C2.
Within
nes
Withinthis
thiscategory,
category,NSF
NSFdefi
defi
nesthe
thesurfaces
surfacesofofequipment
equipmentasasFood
Food
Contact
ContactororNon-Food
Non-FoodContact
Contactsurfaces.
surfaces.Food
FoodContact
Contactsurfaces
surfacesare
are Splash Zones (SN)
further
furtherdivided
dividedinto
intoareas
areasasasFood
FoodZone,
Zone,Splash
SplashZone,
Zone,and
andNon-Food
Non-Food Kenall has two levels of fixture construction depending on the area
Zone,
Zone,with
withFood
FoodZone
Zonerequirements
requirementsbeing
beingthe
themost
moststringent
stringentand
and where the fixtures are being installed.
Non-Food
Non-FoodZone
Zonebeing
beingthe
theleast
leaststringent.
stringent.AAsubcategory
subcategoryofofFood
Food
Our SN type construction is listed for use in Splash Zones and Non
Zone
Zoneequipment
equipmentisisNon-Contact,
Non-Contact,i.e.
i.e.equipment
equipmentininthe
theFood
FoodZone,
Zone, Food Zones. All exposed sheet metal will be painted CRS, painted
but
butnot
notnormally
normallyinincontact
contactwith
withthe
thefood.
food.
aluminum, or anodized aluminum. Fasteners will be stainless steel,
and lenses can be acrylic, polycarbonate or tempered glass, all with
prisms on inside.
Splash
SplashZones
Zones(SN)
(SN)
Kenall
Kenallhas
hastwo
twolevels
levelsofoffixture
fixtureconstruction
constructiondepending
dependingononthe
thearea
area
where
wherethe
thefixtures
fixturesare
arebeing
beinginstalled.
installed.
Our
OurSN
SNtype
typeconstruction
constructionisislisted
listedfor
foruse
useininSplash
SplashZones
Zonesand
andNon
Non
HOSEDOWN
RATINGS
AND
RELATION
Food
AllAllexposed
metal
IP65
FoodZones.
Zones.
exposedsheet
sheet
metalwill
willbebepainted
paintedCRS,
CRS,painted
painted TO IP RATINGS
IP64/IP65
aluminum,
aluminum,ororanodized
anodizedaluminum.
aluminum.Fasteners
Fastenerswill
willbebestainless
stainlesssteel,
steel,
and
andlenses
lensescan
canbebeacrylic,
acrylic,polycarbonate
polycarbonateorortempered
temperedglass,
glass,allallwith
with
prisms
prismsononinside.
inside.
Limitations
of Wet & Hosedown Ratings – UL Standards
The Importance of Recognized Standards &
Independent Testing
UL standards for “wet” type ratings only offer a wet location rating,
which simulates an outdoor rain condition. UL standards for a type
4 or NEMA 4 “hosedown” rating uses a 1 inch diameter nozzle
on a fire hose delivering 65 gallons of water per minute. Various
conditions exist where a fixture requires a rating better than a wet
location label but not NEMA 4. These conditions typically exist in
washdown applications where hose directed water or cleaning
agents will be directed at the fixture.
Benefits of Ingress Protection Ratings – IEC standards
The IP water rating of “5” (IP_5), described in IEC Standard 60598,
provides an intermediate step between the rain rating and the
NEMA 4 rating. It also provides an internationally accepted standard
which can be used to evaluate fixtures or any other electrical
equipment, and the test can be performed by an independent third
party testing agency for verification. Underwriters Laboratories
investigates products and tests to the IEC standard.
Other lighting manufacturers that claim a hosedown rating other
than NEMA or IP are not testing to recognized standards and cannot
have the tests confirmed or audited by an independent outside
testing agency.
Beware of statements such as “Tested to 75psi at 1 inch.”
No reference is made to the volume of water that is leaving the
nozzle and impacting the product. In fact, high nozzle pressures
typically have low water volumes because the nozzle is restricting
the flow of water causing the pressure in the hose to increase,
minimizing the amount of water leaving the nozzle.
Regardless of the hose pressure, any water volume less than
3.3 gal/minute is less severe than the IP_5 test. The most relevant
characteristics are the diameter of the nozzle and the flow rate of
the water. The following chart shows the test characteristics for
various Standards.
MedMaster™ Ratings
Dust-tight Protection
An additional test criterion that can be applied to fixtures is the
ability to exclude solid matter. The IP solid rating of “6” (IP6_)
means the fixture will be dust tight. The specified test requires that
the fixture be placed in a circulating talc atmosphere for 3 hours.
The particle size of the talc is a range of one to 75 microns and the
fixture is placed under negative pressure in an attempt to draw the
talc into the fixture. No talc shall be found inside the fixture after
this test.
When
Whenyou
yousee
seethis
thissymbol
symbolyou
youwill
will
know
knowthe
theKenall
Kenallluminaire
luminairehas
hasbeen
been
tested
ededtotothe
testedand
andcertifi
certifi
the
NSF2
NSF2standard
standard
54
Kenall’s MedMaster line of hosedown rated products are approved
by UL and CUL for
IP ratings
according
to IEC
Standard
60598.
When
you see
this symbol
you
will
know the Kenall luminaire has been
tested and certified to the
What are IEC Standards?
NSF2 standard
IEC Standards are international standards that many European
countries adopt as their national standard. North America has
traditionally adopted UL standards as the source for standards.
U.S. product manufacturers designed their products to IEC standards
initially for sale overseas but are finding them increasingly useful
P: 800-4-Kenall
F: 847-360-1781
here in North America. www. kenall.com
1020 Lakeside Drive Gurnee, Illinois 60031 847-360-8200 FAX 847-360-1781 www.kenall.com
Alpha Numeric Index
PRODUCTBROCHURESPECIFICATION
NUMBERPAGESHEET
CMEXR. . . . . . . . . . . . . . . . . . . . . 4,11 . . . . . . . . . . . . 39
FN15D . . . . . . . . . . . . . . . . . . 5, 19, 33 . . . . . . . . . . . . 49
FN15L . . . . . . . . . . . . . . . . . . 5, 19, 33 . . . . . . . . . . . . 48
METDU . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . . . . . . . . . 34
METEC. . . . . . . . . . . . . . . 5, 13, 20-32 . . . . . . . . . . . . 41
METEL . . . . . . . . . . . . . . . 5, 15, 20-33 . . . . . . . . . . . . 42
METELHC . . . . . . . . . . . . . 5, 17, 20-33 . . . . . . . . . . . . 43
METER. . . . . . . . . . . . 5, 13, 15, 17,31 . . . . . . . . . . . . 44
METSR. . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . . . . . . . . . 37
METSS. . . . . . . . . . 4, 7, 13, 15, 17, 31 . . . . . . . . . . . . 40
METSU. . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . . . . . . . . . 35
METSW. . . . . . . . . . . . . . . . . . . . . . 4, 7 . . . . . . . . . . . . 36
MLER . . . . . . . . . . . . 5, 13, 15, 17, 21 . . . . . . . . . . . . 45
MMEX . . . . . . . . . . . . . . . . . . . . . . 4, 9 . . . . . . . . . . . . 38
MR17WP. . . . . . . . . . . . . . . . . 5, 19, 33 . . . . . . . . . . . . 47
MR17WPSR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
1020 Lakeside Drive
Gurnee, Illinois 60031
847-360-8200 FAX 847-360-1781
www.kenall.com
©2009 Kenall Mfg. Co. All rights reserved.
Download