Cortez A5
®
Square Emergency Light
General Description
Holophane’s Cortez A5 is a self-contained
emergency lighting unit that blends well with
most contemporary interiors. The Cortez A5 is
capable of surface or semi-recessed mounting.
Housing
The frame and backbox are constructed of
impact resistant, UL 94 V-0, 5 VA
thermoplastic. The frame is a matte white
thermoplastic, and the backbox is black
thermoplastic.
The optional backbox for the semi-recessed
version is constructed of 22 gauge steel.
An acrylic lens is standard, and an optional
shatter resistant polycarbonate lens is available.
Certain airborne contaminants can diminish the
integrity of acrylic. Please refer to the Acrylic
Environmental Compatibility Chart (HL-2445) for
suitable uses.
The Cortez A5 may be surface or semi-recessed,
and may be mounted directly to any standard
four inch octagon or square junction box.
Illumination
Illumination is provided by halogen lamps. Plus,
the Cortez A5 features a highly reflective
polished lens for increased illumination. The
CZA512 and CZA5C12 plus the CZA5R and
CZA5R12 are furnished with a 12 watt halogen
lamp. The CZA526 is furnished with a 7 watt
halogen lamp.
Architectural
Electronics
Electrical Specifications
120/277 VAC dual voltage input with surge
protected, solid-state charging circuitry provides
for a reliable charging system. The charging
system is furnished with low voltage disconnect,
AC lockout, brownout protection, AC indicator
lamp and test switch.
Input Power Requirements
120 VAC - 0.096 amps, 10 watts
277 VAC - 0.04 amps, 10 watts
The low voltage disconnect (LVD) feature will
disconnect the battery prior to an unacceptable
deep discharge, but not before the required 90
minute emergency operation.
CZA526SM
The AC lockout feature prevents battery drain
prior to the initial energizing of utility power,
and allows the installer to complete all wiring
and electrical connections without energizing
the emergency circuit.
The brownout protection circuitry will
automatically switch the unit into the emergency
mode if the utility voltage sags below 20% of
nominal.
Battery charging circuitry is entirely solid-state,
and utilizes a constant current charger for nickel
cadmium battery units. A fully automatic, voltage
regulated charger is used for lead calcium
battery units. Battery recharge time after full
discharge is less than the required UL 924
standard.
Line sensitive electronics cause an instantaneous
transfer to battery power if utility power is lost,
or a brownout condition is detected. When line
voltage is present and stabilized, the transfer
circuitry switches back to normal operation
and begins recharging the battery. The transfer
circuitry can be tested via a momentary test
switch located on the housing.
Listings
• UL 924 listed
• NFPA 101, NEC, BOCA, OSHA and IBC
illumination standards
Warranty
3-year limited warranty.
Complete warranty terms located at:
www.acuitybrands.com/
CustomerResources/Terms_and_
conditions.aspx
Actual performance may differ as a result of
end-user environment and application.
Note: Specifications are subject to change
without notice.
Dimensions
3
(96.
Surface Mount
9"
(228.6mm)
Battery
9"
(228.6mm)
Maintenance free, sealed nickel cadmium
or lead calcium batteries are available. All
batteries are equipped with a quick connect
plug assembly for easy installation.
Maintenance free, sealed lead calcium battery
has a typical life of up to 5 years, and an
Surface
Mount
operating temperature range
of 65°F
(19°C) to
85°F (30°C)
Fully Recessed Mount
Maintenance free, sealed nickel (228.6mm)
cadmium
battery has a typical life of up to 10 years, and
an operating temperature range of 20°F (-7°C)
to 95°F (35°C)
1.6"
(40.6mm)
9"
9"
Nickel cadmium batteries are recommended for (228.6mm)
3.8"
11.6"
(96.5mm)
(259.3mm)
11.6"
8"
(259.3mm)
(203.2mm)
semi- or fully recessed versions and high
ambient temperature areas.
HL-1330 Rev. 8/20/15
Standard sustained emergency operation is
for 90 minutes with the illumination source
Fully Recessed Mount
providing full light output.
11.6"
(259.3mm)
3.8"
Cortez A5
®
®
Square Emergency Light
Suggested Specification
Architectural
Illumination
Furnish and install Holophane’s self-contained emergency lighting model
_______________________. The unit shall be constructed to meet Underwriter’s
Laboratories, Inc. Standard #924 and the National Electrical Code (NEC).
The unit shall incorporate one 12 watt halogen lamp or one 7 watt halogen lamp. A
highly reflective polished lens shall be included for increased illumination.
Installation and Operation
The frame and backbox shall be constructed of lightweight, flame retardant, impact
resistant, UL 94 V-0, 5 VA thermoplastic. The frame shall be matte white, and the
backbox shall be black. The semi-recessed version shall have a 22 gauge steel backbox.
Unit shall be easily field connected to a 120 or 277 VAC, 60 hertz, unswitched power
source. Installation must comply with the NEC as well as other applicable codes. Upon
utility power failure or brownout, the unit shall automatically transfer to battery power
and maintain the required illumination for a minimum period of 90 minutes. Upon
restoration of utility power, the charger shall restore the battery to full charge within UL
924 requirements following a rated discharge of not more than 90 minutes.
Charger
Product shall utilize either a constant current (nickel cadmium) or fully automatic,
voltage regulated (lead calcium) charging system. The charging system shall maintain
the battery at full capacity without the need for periodic exercising or equalization.
The following features shall be standard: Low voltage disconnect (LVD), brownout
protection and AC lockout.
Housing
Lamps
All Cortez A5 series lamps are halogen, with a reflector lens system to provide a 172º
beam spread.
Standard Controls
Shall include a press-to-switch which simulates a power failure and an AC monitor light.
Battery
The battery shall be either a maintenance free, sealed nickel cadmium or lead calcium
battery. The nickel cadmium battery shall utilize sintered plate construction and
polypropylene separators for trouble-free operation in ambient temperatures up to 95°F
(35°C). The lead calcium battery shall provide trouble-free operation in temperatures
up to 85°F (30°C).
Ordering Data
CZA5
Series
CZA51, 2 Cortez A5
How to construct a catalog number
Example: CZA5 12 SM PC
12
SM
Voltage/Wattage/Battery Type1
12 12W, 6 volt, nickel
cadmium, 12W lamp 26 26W, 6 volt, nickel
cadmium, 7W lamp
C12 12W, 6 volt, lead calcium
12W lamp
R
Remote 6 volt
R12 Remote 12 volt
Mounting2
SM Surface mount
PC
Options (Factory installed)3
PC Polycarbonate lens
V Voltmeter
2L (2) 7 watt lamps (CZA526 only)
Accessories (Shipped separately)
CZA56SMR Surface mount remote unit (6 volt)
CZA512SMR Surface mount remote unit (12 volt)
Semi-recessed mounting kit
HPRMP1
Wire guard for surface mount units
HPWG3 Wire guard for fully recessed units
HPWG4 Notes
1. Nickel cadmium units are recommended for recessed applications.
2. For semi-recessed applications, order surface mount (SM) and
HPRMP1 accessory.
3. Some option combinations may impact UL listing. Consult factory
for specifics.
Acuity Brands Lighting, Inc.
Holophane Headquarters, 3825 Columbus Road,
Granville, OH 43023
Acuity Brands Lighting Canada, Inc.,
35B Minthorn Blvd., Markham, ON., L3T 7N5
Contact your local Holophane factory sales representative
for application assistance, and computer-aided design and
cost studies. For information on other Holophane products
and systems, call the Inside Sales
Service Department at 740-345-9631. In Canada call
905-886-8967 or fax 905-886-7973.
Holophane Europe Limited, Bond Ave.,
Milton Keynes MK1 1JG, England
Holophane, S.A. de C.V., Km. 31 Carretera
Mexico-Cuautitlan 54900 Tultitlan Edo. De Mexico
HL-1330 Rev. 8/20/15
©2012-2015 Acuity Brands Lighting, Inc. All Rights Reserved.
Visit our web site at www.holophane.com
Luminaires may utilize fluorescent or high intensity
discharge sources that contain small amounts of
mercury. New disposal labeling for these lamps
includes the mercury identifier shown on the left to indicate
that the lamp contains mercury and should be disposed of
in accordance with local requirements.
Information sources regarding lamp recycling and disposal
are included on the packaging of most mercury-containing
lamps and also can be located at www.lamprecycle.org.