SURE-LITES FBP140XLP Instruction Manual IMPORTANT SAFEGUARDS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. CAUTION: To prevent electrical shock, do not mate unit connector until installation is complete and A.C. power Risk of Fire/ is supplied to the unit. Electric Shock If not qualified, consult an 2. CAUTION: This fixture provides more than one power supply output source. To reduce the risk of electrical electrician. shock, disconnect both normal and emergency sources by turning off the A.C. Branch circuit and by disconnecting the unit connector. 3. The battery is sealed, non-maintenance, and is not replaceable in the field. Please contact manufacturer for information on service. Do not attempt to service the battery please. Keep away from flammable 4. DO NOT USE OUTDOORS. The product is for use with grounded, UL Listed, indoor fixtures except in heated air vapors or materials. outlets or hazardous locations. 5. The product requires an unswitched A.C. Power source of either 120 or 277 volts. Properly cap the unused A.C. Lead. 6. Do not mount near gas or electric heaters. 7. The product should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. Risk of Electrical Shock 8. The product will cold strike and operate one 2´ through 4´ (17-40W) instant start, rapid start, program rapid start, Disconnect power at fuse U shape or circline, T8 or T12 standard or energy saving fluorescent lamp for 90 minutes at reduced light or circuit breaker before installing or servicing. output. 9. The product is compatible with all A.C. magnetic and electronic ballasts including multiple lamp ballasts with one lamp operating in the emergency mode. For use in temperature rating 20°C — 50°C 10. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. 11. Do not use this equipment for other than intended use. 12. Install in accordance with the National Electrical Code and local regulations. C US LISTED 13. Installation and servicing should be performed by qualified personnel. 14. Lighting fixture manufacturers, electricians and end users need to ensure product system compatibility Emergency Lighting Unit before final installation. Indoor Damp Location Listed 15. The battery is sealed,non-maintenance,and is not replaceable in the field. Please contact manufacturer for information on service. Do not attempt to service the battery please. CONTAINS NICKEL-CADMIUM 16. The rated operating time in the emergency mode with battery is 1-1/2 hours and the recharge RECHARGEABLE BATTERY. time shall not be less than 24 hours. MUST BE RECYCLED OR 17. SAVE THESE INSTRUCTIONS DISPOSED OF PROPERLY. Ni - Cd INSTALLATION INSTRUCTIONS CAUTION: BEFORE INSTALLING, MAKE CERTAIN THE A.C. POWER IS OFF AND THE BATTERY CONNECTOR IS DISCONNECTED. 1. MOUNTING THE FBP140XLP Remove the ballast channel cover. Mount the FBP140XLP in the ballast channel at least 1/2 inch away from the A.C. Ballast(s) using screw with large enough head to securely hold battery. When battery packs are remote mounted, the remote distance can not exceed of the distance from ballast to lamp specified by the A.C. Ballast manufacturer. For example, if the A.C. Ballast manufacturer recommends no more than 25´ remote distance, then the battery pack should not exceed 12´. Under no circumstances should the battery pack exceed a distance of 50´ from the lamp. 2. WIRING Refer to the wiring diagrams on the back page for the appropriate wiring of lamp(s) and ballast. Install in accordance with the National Electrical Code and local regulations. For additional wiring diagrams consult Customer Service. 1 Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 7/09 ADX091238 SURE-LITES 3. INSTALLING THE TEST BUTTON, INDICATOR LIGHT (TBIL) Recessed Troffer Fixture (Figure 1A) - Select a convenient location with proper clearance in the ballast cover and drill or punch a 7/8˝ hole. Insert the 7/8˝ bushing into the hole. Push the plastic tube through the bushing. Route the leads of the TBIL through the plastic tube. Connect the LED wires from the unit to the TBIL (Red to Red, White to White/Red). Push the entire assembly back into the tube until the lens collar rests against the plastic tube. The plastic tube should be adjusted so that the TBIL is within 1/4˝ of the fixture lens. The TBIL must be visible after installation. Recessed Troffer, Surface Mounted or Strip Fixture (Figure 2A or 2B) - Select a convenient location on the fixture so the TBIL can be seen after installation. Allow for proper clearance inside the fixture and drill or punch a 1/2˝ hole. In some cases KOs are provided on the ballast channel cover. Remove the nut from the TBIL. Push the TBIL housing into the 1/2˝ hole and secure with the nut. Connect the LED wires from the TBIL to the Red and White/Red wires on the battery pack (Red to Red, White to White/Red). The TBIL must be visible after installation. Figure 1A Figure 2A Recessed Troffer Fixture Recessed Troffer with or without Lens or Surface Mounted Fixture FIXTURE BALLAST CHANNEL COVER FIXTURE FBP140XLP TBIL FBP140XLP PLASTIC TUBE 7/8” BUSHING BALLAST CHANNEL COVER TBIL FIXTURE LENS TEST BUTTON, INDICATOR LIGHT (TBIL) Figure 2B Strip Fixture FIXTURE TBIL + RED LEAD WHITE LEAD FBP140XLP – OBSERVE PROPER POLARITY 4. WIRING THE A.C. INPUT Step 1. The FBP140XLP and A.C. Ballast must be on the same branch circuit. Step 2. The FBP140XLP requires an unswitched A.C. Power source of either 120 or 277 volts. Select the proper voltage lead and cap the unused lead. Step 3. When the FBP140XLP is used with a switched fixture, the A.C. input to the FBP140XLP must be connected ahead of the fixture switch. Refer to Figure 3 for switched and unswitched fixture wiring diagrams. 2 Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 7/09 ADX091238 SURE-LITES 5. BALLAST WIRING BLOCK DIAGRAM Figure 3 BLACK BLACK WHITE WHITE HOT A.C. LINE HOT A.C. LINE WHT/BLK WHT/BLK WHITE COMMON WHITE COMMON (277V) ORG (277V) ORG 1 WHITE INDICATOR LIGHT FBP140XLP – WHT/RED + RED RED 1 (120V) BLK INDICATOR LIGHT Select proper voltage lead. Cap unused lead. 1 (120V) BLK WHITE – WHT/RED RED 1 FBP140XLP + RED Select proper voltage lead. Cap unused lead. 6. LABELS Attach the appropriate labels adjacent to the TBIL. The Caution label and relamping label must be on the fixture in a readily visible location to anyone attempting to service the fixture. Relamping label should be annotated to indicate the proper lamps to be used during relamping. 7. COMPLETING INSTALLATION When the installation is complete, join the FBP140XLP unit connector and replace the ballast cover ensuring no wires are pinched. Switch the AC Power on. OPERATION Normal Mode - A.C. power is present. The A.C. ballast operates the fluorescent lamp(s) as intended. The FBP140XLP is in the standby charging mode. The TBIL will be lit providing a visual indication that the battery is being charged. Emergency Mode - The A.C. Power fails. The FBP140XLP senses the A.C. Power failure and automatically switches to the Emergency Mode. One lamp is illuminated, at reduced output, for a minimum of 90 minutes. When the A.C. Power is restored, the FBP140XLP switches the system back to the Normal Mode and resumes battery charging. TESTING & MAINTENANCE Pressing the red lens on the TBIL turns off the light on the TBIL and forces the unit into emergency mode. This interrupts power to the emergency lamp only. The emergency lamp is now being lit by the FBP140XLP unit and will be less bright than the other lamps in the system. To simulate a BLACK OUT use the switch or circuit breaker to turn off A.C. Power. Initial Testing - Allow the unit to charge at least 60 minutes, then press the TBIL to conduct a short discharge test. The FBP140XLP is a maintenance free unit, however, periodic inspection and testing is required. NFPA 101, Life Safety Code, outlines the following schedule: Monthly - Insure that the TBIL is illuminated. Conduct a 30 second discharge test by depressing the TBIL. One lamp should operate at reduced output. Annually - Insure that the TBIL is illuminated. Conduct a full discharge test. The unit should operate the lamp for the a full 90 minutes at reduced output. Allow a 24 hour charge before conducting 90 minute test. Written records of testing shall be kept by the owner for inspection by the authority having jurisdiction. SERVICING SHOULD BE PERFORMED BY QUALIFIED PERSONNEL. 3 Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 7/09 ADX091238 SURE-LITES TYPICAL WIRING DIAGRAMS For wiring diagrams for ballasts not shown, consult Cooper Lighting Customer Service at 1-800-955-4908 or email - parts@cooperlighting.com 3 TEST ACCESSORY LEADS- REFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. TBIL WHITE WHT/BLK 1 SELECT PROPER VOLTAGE LEAD CAP UNUSED LEAD. INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. 3 CONNECT BLU/WHT AND YELL/BLK WIRES TOGETHER. 4 TBIL TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. 4 WHT/BLK 4 LAMP SELECTOR LEADS-REFER TO INSTALLATION INSTRUCTIONS LAMPS OPERATION SECTION FOR VARIOUS OPTIONS ON PAGE 6 LAMP FBP140XLP 2 UNIT CONNECTOR *LAMP 3 TEST ACCESSORY LEADS- 3 WHT/BLK 4 3 TEST ACCESSORY LEADS- REFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. WHT/BLK 4 LAMP SELECTOR LEADS-REFER 4 LAMP SELECTOR LEADS-REFER TO INSTALLATION INSTRUCTIONS LAMPS OPERATION SECTION FOR VARIOUS OPTIONS ON PAGE 6 WHITE LAMP VIOLET VIOLET RED 2 UNIT CONNECTOR - WHT/RED FBP140XLP BLK (120V) WHITE 4 3 TBIL WHITE WHT/BLK 1 2 1 UNSWITCHED COMMON SELECT PROPER VOLTAGE LEAD CAP UNUSED LEAD. DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. VIOLET VIOLET RED - WHT/RED + 1 SELECT PROPER VOLTAGE LEAD CAP UNUSED LEAD. 4 TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. 5 LAMP SELECTOR LEADS-REFER *AC/EMERGENCY TO INSTALLATION INSTRUCTIONS LAMPS OPERATION SECTION FOR VARIOUS OPTIONS ON PAGE 6 8. THREE LAMP INSTANT START BALLAST BLACK WHITE RED BLUE A.C. Ballast BLUE BLUE 3 BLUE BLUE/WHT YELL/BLK YELLOW RED LAMP ORG (277V) FBP140XLP 2 UNIT CONNECTOR LAMP *LAMP BLK (120V) WHITE 5 4 TBIL REFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. WHITE WHT/BLK 4 LAMP SELECTOR LEADS-REFER *AC/EMERGENCY RED WHITE WHT/BLK 3 TEST ACCESSORY LEADS- TO INSTALLATION INSTRUCTIONS LAMPS OPERATION SECTION FOR VARIOUS OPTIONS ON PAGE 6 UNSWITCHED COMMON INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. 3 CONNECT BLU/WHT AND YELL/BLK WIRES TOGETHER. 4 WHITE SWITCHED OR UNSWITCHED LINE 2 DO NOT MATE CONNECTOR UNTIL VIOLET ORG (277V) + LAMP *LAMP BLUE BLUE/WHT YELL/BLK YELLOW RED RED BLUE/WHT BLUE/WHT RED RED SWITCHED OR UNSWITCHED LINE 5 TBIL REFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. 4 LAMP SELECTOR LEADS-REFER TO INSTALLATION INSTRUCTIONS LAMPS OPERATION SECTION FOR VARIOUS OPTIONS ON PAGE 6 7. THREE LAMP RAPID START SERIES LAMP PARALLEL YELLOW FILAMENT A.C. Ballast 2 UNIT CONNECTOR *LAMP 1 BLK (120V) WHITE FBP140XLP 3 TEST ACCESSORY LEADS- WHT/BLK *AC/EMERGENCY BLACK WHITE BLUE BLUE YELLOW YELLOW ORG (277V) VIOLET RED WHITE SELECT PROPER VOLTAGE LEAD CAP UNUSED LEAD. 2 DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. 3 TBIL WHITE 3 BLUE LAMP 1 4 + CONNECTOR A.C. Ballast BLUE BLUE/WHT YELL/BLK YELLOW RED RED *LAMP COMMON RED BLUE - WHT/RED 2 UNIT UNSWITCHED BLACK WHITE + LAMP 1 BLK (120V) WHITE FBP140XLP VIOLET BLUE BLUE SWITCHED OR UNSWITCHED LINE ORG (277V) VIOLET A.C. Ballast BLUE BLUE/WHT YELL/BLK YELLOW RED RED YELLOW YELLOW RED RED WHT/RED BLACK WHITE 6. TWO LAMP INSTANT START BALLAST RED 5. TWO LAMP RAPID START OSRAM SYLVANIA SERIES LAMP PARALLEL YELLOW FILAMENT TO INSTALLATION INSTRUCTIONS LAMPS OPERATION SECTION FOR VARIOUS OPTIONS ON PAGE 6 *AC/EMERGENCY WHITE *AC/EMERGENCY COMMON SELECT PROPER VOLTAGE LEAD CAP UNUSED LEAD. 2 DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. 3 WHITE UNSWITCHED 1 TBIL REFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. 1 BLK (120V) WHITE VIOLET RED RED SWITCHED OR UNSWITCHED LINE ORG (277V) VIOLET A.C. Ballast BLUE BLUE/WHT YELL/BLK YELLOW RED BLUE BLUE RED YELLOW YELLOW SELECT PROPER VOLTAGE LEAD CAP UNUSED LEAD. DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. 2 TBIL WHITE BLACK WHITE - WHT/RED RED WHITE COMMON 1 4 UNSWITCHED 4. TWO LAMP RAPID START SERIES LAMP SERIES YELLOW FILAMENT + 2 UNIT CONNECTOR 1 BLK (120V) WHITE VIOLET LAMP *LAMP SWITCHED OR UNSWITCHED LINE ORG (277V) FBP140XLP VIOLET RED RED RED A.C. Ballast BLUE BLUE/WHT YELL/BLK YELLOW RED - WHT/RED YELLOW YELLOW BLUE BLUE + BLACK WHITE TO INSTALLATION INSTRUCTIONS LAMPS OPERATION SECTION FOR VARIOUS OPTIONS ON PAGE 6 RED 3. TWO LAMP RAPID START SERIES / PARALLEL LAMP PARALLEL YELLOW FILAMENT 5 LAMP SELECTOR LEADS-REFER *AC/EMERGENCY WHITE *AC/EMERGENCY UNSWITCHED COMMON 2 DO NOT MATE CONNECTOR UNTIL 5 WHITE 1 BLK (120V) WHITE VIOLET 2 UNIT CONNECTOR *LAMP SWITCHED OR UNSWITCHED LINE ORG (277V) FBP140XLP YELLOW RED VIOLET 3 RED RED A.C. Ballast - WHT/RED WHITE SELECT PROPER VOLTAGE LEAD CAP UNUSED LEAD. DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. 2 3 BLACK BLUE BLUE/WHT YELL/BLK + VIOLET COMMON 1 4 UNSWITCHED BLUE RED 1 BLK (120V) WHITE VIOLET RED - WHT/RED 2 UNIT CONNECTOR *LAMP SWITCHED OR UNSWITCHED LINE ORG (277V) FBP140XLP + A.C. Ballast RED RED RED BLUE BLUE/WHT YELL/BLK YELLOW RED WHITE BLACK WHITE BLUE BLUE 2. ONE LAMP INSTANT START BALLAST WHITE 1. ONE LAMP RAPID START BALLAST *AC/EMERGENCY SWITCHED OR UNSWITCHED LINE 1 UNSWITCHED COMMON 1 SELECT PROPER VOLTAGE LEAD CAP UNUSED LEAD. 2 DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. 3 CONNECT BLU/WHT AND YELL/BLK WIRES TOGETHER. TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. 5 LAMP SELECTOR LEADS-REFER TO INSTALLATION INSTRUCTIONS LAMPS OPERATION SECTION FOR VARIOUS OPTIONS ON PAGE 6 4 NOTE: Use the proper input voltage lead, cap unused leads 4 Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 7/09 ADX091238 SURE-LITES TYPICAL WIRING DIAGRAMS For wiring diagrams for ballasts not shown, consult Cooper Lighting Customer Service at 1-800-955-4908 or email - parts@cooperlighting.com 10. FOUR LAMP INSTANT START BALLAST LAMP LAMP RED RED 3 LAMP 2 UNIT CONNECTOR LAMP LAMP *LAMP WHITE TBIL 1 SELECT PROPER VOLTAGE LEAD CAP UNUSED LEAD. 5 2 DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. 3 CONNECT BLU/WHT AND YELL/BLK WIRES TOGETHER. 4 TO INSTALLATION INSTRUCTIONS LAMPS OPERATION SECTION FOR VARIOUS OPTIONS ON PAGE 6 *AC / EMERGENCY SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. 5 LAMP SELECTOR LEADS-REFER *AC/EMERGENCY WHT/BLK WHITE 4 WHT/BLK WHITE UNSWITCHED COMMON TBIL *LAMP 1 BLK (120V) FBP140XLP VIOLET BLUE VIOLET YELLOW A.C. Ballast RED COMMON YELLOW SWITCHED OR UNSWITCHED LINE ORG (277V) - WHT/RED WHITE UNSWITCHED VIOLET LAMP RED UNIT CONNECTOR WHITE 1 BLUE BLUE/WHT YELL/BLK YELLOW RED WHITE FBP140XLP VIOLET BLUE/WHT BLUE/WHT RED RED ORG (277V) BLK (120V) . - WHT/RED A.C. Ballast BLUE BLUE/WHT YELL/BLK YELLOW RED + BROWN BROWN YELLOW YELLOW BLUE BLUE RED WHITE WHITE BLACK BLUE BLACK + SWITCHED OR UNSWITCHED LINE RED 9. FOUR LAMP RAPID START SERIES LAMP PARELLEL YELLOW FILAMENT LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS ON PAGE 6 TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING . 11. THREE LAMP RAPID START PARALLEL LAMP PARALLEL YELLOW FILAMENT 12. FOUR LAMP RAPID START PARALLEL LAMP PARALLEL YELLOW FILAMENT SWITCHED OR UNSWITCHED LINE *LAMP TBIL ORG (277V) LAMP LAMP BLK (120V) WHITE 1 UNSWITCHED COMMON VIOLET UNIT CONNECTOR LAMP VIOLET FBP140XLP RED A.C. Ballast + COMMON WHITE RED VIOLET UNSWITCHED VIOLET WHITE BLACK 1 - WHT/RED LAMP RED UNIT CONNECTOR LAMP BLK (120V) WHITE ORG (277V) FBP140XLP - WHT/RED BLUE BLUE/WHT YELL/BLK YELLOW RED RED/WHT RED/WHT BLUE BLUE RED RED YELLOW YELLOW + A.C. Ballast RED WHITE WHITE BLACK SWITCHED OR UNSWITCHED LINE BLUE BLUE/WHT YELL/BLK YELLOW RED BLUE/WHITE BLUE/WHITE RED/WHT RED/WHT BLUE BLUE RED RED YELLOW YELLOW TBIL *LAMP WHITE SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. WHITE WHT/BLK WHT/BLK *AC/EMERGENCY *AC / EMERGENCY LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS ON PAGE 6 TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. LAMP SELECTOR LEADS—REFER TO INSTALLATION INSTRUCTIONS, LAMPS OPERATION SECTION FOR VARIOUS OPTIONS ON PAGE 6 TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. NOTE: Use the proper input voltage lead, cap unused leads 5 Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 7/09 ADX091238 SURE-LITES LAMP SELECTOR LEAD INSTRUCTIONS 2 UNIT CONNECTOR UNSWITCHED WHITE 5 4 TBIL WHITE 1 BLK (120V) VIOLET LAMP *LAMP RED BLUE FBP140XLP VIOLET 3 ORG (277V) + A.C. Ballast BLUE BLUE/WHT YELL/BLK YELLOW RED RED RED BLUE WHITE - WHT/RED BLACK WHITE SWITCHED OR UNSWITCHED LINE WHT/BLK *AC/EMERGENCY 1 SELECT PROPER VOLTAGE LEAD CAP UNUSED LEAD. 2 DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED. 3 CONNECT BLU/WHT AND YELL/BLK WIRES TOGETHER. 4 TEST ACCESSORY LEADSREFER TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY WIRING. 5 LAMP SELECTOR LEADS - REFER TO INSTALLATION INSTRUCTIONS LAMPS OPERATION SECTION FOR VARIOUS OPTIONS This unit features 6˝ Lamp Selector Leads (violet) for optimizing light output of specific lamps. The unit is shipped from the factory with these leads disconnected. For some lamps these leads should be connected. If disconnected leads should be capped. *See chart below. This unit can be used with most 2´ - 4´ lamps. Refer to the chart below for the type of lamp operated in emergency mode. OPTION LAMP TYPE EMERGENCY OPERATION *VIOLET LEADS WIRING DIAGRAMS 1 2´ T8, or T12 Single or Bipin (up to 20W) One Lamp Connected 1,2,3,4,5,6,7,8,9 2 4´ T8, or T12 Single or Bipin (up to 40W) One Lamp Disconnected and Capped 1,2,3,4,5,6,7,8,9 6 Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 7/09 ADX091238