Note on English translation / Hinweise zur englischen Fassung This is a translation of the technical data sheet valid in Germany. All stated details and properties are in compliance with the regulations of the German standards and building regulations. They are only applicable for the specified products, system components, application rules, and construction details in connection with the specifications of the respective certificates and approvals. Knauf Gips KG denies any liability for applications outside of Germany as this requires changes acc. to the respective national standards and building regulations. E112.de Drywall Systems 2012-03 Knauf alutop Access Panels REVO Access panels for all partition and ceiling systems without requirements for building physics REVO 12.5 / REVO 18 Variant / REVO 25 Variant Product description Properties ■ One type for ceilings and walls Access panels for the installation in walls (drywall partitions and furrings) and in suspended ceilings. Suitable for all cladding thicknesses from 10 to 25 mm, consisting of ■ REVO 18 Variant for 15 and 18 mm cladding thickness ■ an anodised aluminium frame with swivelling and fully detachable hatch Additional options / special designs ■ Intermediate dimensions ■ flush bonded face board made of Knauf Diamant (200x200 mm to 600x600 mm) ■ Multipart design ■ Small opening displacement of the lock and low installation depth in the cavity ■ screw-fixed face board made of Knauf Diamant without bracing profiles (up to 800x800 mm) or with bracing profiles (> 800x800 mm) ■ Airtight and dust-proof (class 3, EN 1026+12207, suction and pressure) ■ Suitable for subsequent installation in finished walls/ceilings. ■ Four-square bolt ■ Accurately fitting with tiling in sanitary facilities ■ REVO 25 Variant for 20 and 25 mm cladding thickness ■ Round cylinder lock ■ self-activating drop catch ■ Lock designed for profile cylinder Product range ■ REVO 12.5 with spacer strips for 10 mm Knauf Thermoboard and for 12.5 mm cladding thickness ■ Screw-fixed face board made of Knauf Diamant for on-site exchange (< 625x625 mm) ■ Prepared for surface quality Q4 (on-site) ■ Prepared for on-site tiling ■ Universally suitable for various cladding thicknesses ■ Flush bonded Diamant face board, i. e. no filling is required for the hatch E112.de Knauf alutop Access Panels REVO Access panels for all partition and ceiling systems without requirements for building physics Installation in Knauf ceiling systems Example: Type 12.5 mm - without seal CD Channel (trimmer) Access Panel 5 30 100 E112.de-V2 Size (= clearance) Opening dimension of cladding (= size + 2x 5 mm) 30 1) E112.de-V1 Schematic drawings - dimensions in mm Knauf board 5 Size = clearance Notes Observe the included installation guide of the access panel Installation of Ceiling systems Partition systems Furring systems acc. to the Knauf Technical Data Sheets 30 100 Example: Type 12.5 mm - with seal 6 Size 6 Vertical sections Installation in Knauf Partition / Furring Systems E112.de-V3 Possible cladding thicknesses Example: Partition system with 12.5 mm cladding - without seal REVO 12.5 10 mm Thermoboard 12.5 mm Outer frame 30 2) UW Profile as trimmer Hatch Frame spacer or spacer strip 3) E.g. CW Stud REVO 18 Variant 18 mm 5 30 100 15 mm REVO 25 Variant 20 mm 30 100 2x 12.5 / 25 mm Access Panel Frame spacer or spacer strip 3) 5 Opening dimension of cladding (= size + 2x 5 mm) Size (= clearance) Frame spacer or spacer strip 3) Knauf board Cladding thickness Sizes Weight mm w x h) mm kg/piece REVO 12,5 10 Thermoboard 12.5 REVO 18 Variant 15 18 Vertical section 1) Distance to the basic ceiling / installations 2 2) Opening displacement clearance of the access panel REVO 25 Variant 20 2x 12.5 / 25 200 x 200 ca. 1.2 - 1.5 300 x 300 ca. 2.0 - 2.4 400 x 400 ca. 3.0 - 3.4 500 x 500 ca. 4.3 - 4.7 600 x 600 ca. 5.8 - 6.8 700 x 700 ca. 11.0 - 11.7 ca. 14.0 - 14.8 800 x 800 Customized sizes are available on request 4) 3) Frame spacer or spacer strips are included in the packaging 4) Max. square size for single part design: 1200 x 1200 mm Copyright by Knauf Gips KG- \\Iphcad01\kg_psp_data$\data\2012\04\0\E112.DE_DETAIL1-0312.dwg - St. 03.12 Seite 2 E112.de Knauf alutop Access Panels REVO Access panels for all partition and ceiling systems without requirements for building physics REVO 12.5 Equipment options REVO 18 Variant REVO 25 Variant Intermediate dimensions 5) Multi-part design (max. size 1200 x 3600 mm) 6) Seal 7) Included as standard 5) Size min. 200 x 200 mm, max. 1200 x 1200 mm wall / ceiling; max. 800 x 1400 mm wall 6) Only for installation in ceilings 7) Seal is standard for panel sizes > 600 x 600 mm 8) Screw-fixing of face board is standard for panel sizes > 600 x 600 mm Designed for on-site tiling (max. size 600 x 800 mm) Prepared for surface quality Q4 (on-site) Airtight and dust-proof (class 3, suction and pressure) Four-square bolt lock Round cylinder lock Lock designed for profile cylinder Screw-fixed face board 8) Examples (scheme drawings) Installation in Knauf Ceiling Systems Installation in Knauf Partition / Furring Systems Additional substructure 4 additional supsensions (e. g. Nonius Suspension) Alternative suspension points Additional substructure or trimming Depending on type and installation situation of the access panels, trimmer profiles or frames made of profiles are necessary. Universal connectors are required for the trimmings. If suspended channels need to be cut and replaced by an additional trimmer channel, additional suspenders are necessary. Subsequent installation in walls is possible If the installation of the access panel is performed at a later time, the cladding is sawed out. Apply frame made of circumferential profile pieces (UW or CW) and screw attach (spacing of screws 150 mm). CD Channel Access panel Connector Stud spacing -a- continuous Spacing of carrying channels Double-level metal grid (e. g. D112.de) Spacing of furring channels Connector Spacing of furring channels E. g. CW Stud a a Stud spacing -a- with cut stud and trimmer profiles Spacing of carrying channels Access panel UW Profile a Flush metal grid (e.g. D113.de) CD Channel Access panel CW Stud UW Profile E. g. CW Stud a a a 3 Copyright by Knauf Gips KG- \\Iphcad01\kg_psp_data$\data\2012\04\0\E112.DE_SCHEMA1-0312.dwg - St. 03.12 Seite 3 E112.de Knauf alutop Access Panels REVO Access panels for all partition and ceiling systems without requirements for building physics Order information Construction Required specifications for ordering: ■ Size of the access panel (w x h) ■ Mounting component, e. g, ceiling, partition ... ■ Cladding thickness ■ Access panels for tiling: Specify tile dimensions (w x h), joint width, adhesive thickness, tile thickness and cladding thickness. The exact clearance is determined through the tile format. ■ Additional options: see page 3 Select access panels considering cladding thickness of the Knauf systems. Knauf alutop Access Panels consist of a firm outer aluminium frame, and a swivelling and fully detachable hatch. REVO are equipped with flush bonded or screw-fixed face board made of Knauf Diamant hard gypsum board. Outer frame and hatch of the access panels are reinforced on the rear side using corner connectors. The hatch is fixed flush with the outer frame using special Knauf alutop locks and hinge brackets. A joint width of only approx. 1.5 mm is visible between the outer frame and the hatch when fully mounted. With rectangular ceiling access panels, the lock and hinge system is always mounted on the long side. With access panels for partitions the lock is always on top while the hinges are on the bottom side. Installation requires additional substructure with trimmer profiles. The access panels are suitable for subsequent installation in finished walls/ceilings. The use of round cylinder or profile cylinder locks and four-square bolting is optional. Installation of access panels as per accompanying application instructions, installation of Knauf Systems in accordance with relevant current Knauf Technical Data Sheets. Use drywall screws TB or Diamant Screws for the attachment of the frame to the cladding. CAUTION: The required length of the screws is determined by the cladding thickness. Apply at least 2 screws per frame side for panel size < 500x500 mm, at least 3 or 4 screws for panel size ≥ 500x500 mm. The max. screw spacing is 200 mm. No board joints of the cladding are allowed near the access panels. With wall access panels, a clearance of ≥ 30 mm must be ensured in the upper third of the rear side of the hatch for opening the panel. It is possible to install the access panel at the same time as the substructure or after the cladding application. Cut out opening 12 mm (with REVO 12.5 without seal 10 mm) larger than the access panel size (= clearance). Install additional trimmer profiles made of CD or CW or UW profiles based on the dimensions of the access panel, maintain distances between the cutout section and trimmer profiles of ≥ 30 mm and ≤ 100 mm. Mount 4 additional supsenders in the corner areas of the access panel in ceilings. More additional suspenders are required for replacing suspended ceiling profiles. Place the outer frame of the access panel in the opening, lay it on the cladding, align and screw attach. Subsequently insert hatch and check lock for proper functioning. If the distance to the installations in the wall or ceiling is less than 200 mm, it is necessary to perform the installation of the outer frame in the gypsum board before the cladding. ■ See included installation guide for more information Jointing Surface treatment Fill outer frame of access panel and the ceiling/ wall surface fully with Uniflott. It is not necessary to fill or skim the hatch face when using in case of flush bonded gypsum boards and surface quality Q2. Fill screw heads of screw-fixed face boards. For surface quality level Q3: Scrape skim hatch face. Preparation for quality level Q4 on request. Clean outer frame, hatch, and particularly seal thoroughly after filling. For surface treatment of the access panels with gypsum board face follow Knauf Technical Data Sheet for the respective system. Installation Note for access panels prepared for tiling: Tile application is only permissible with thin-bed method. Fill joint between cladding and outer frame after installation of the access panel. The edge of the wall tile can be directly applied on the clearance dimension. Install seal (included). Note to the painter Generally remove the access panel hatch before coating and paint separately so that no paint penetrates the narrow joint between the hatch and the outer frame. Thoroughly clean outer frame, hatch, and particularly the seal. ■ See www. knauf.de - Technical Data Sheet E112C Knauf alutop Access Panel REVO Apertura 12.5 .QDXI'LUHFW 7HFKQLFDO$GYLVRU\6HUYLFH 3KRQH )D[ ZZZNQDXIGH X123.de/dtsch./xx.xx/FB/D E112.de/engl./03.12/FB/D .QDXI*LSV.*$P%DKQKRI,SKRIHQ*HUPDQ\ &DOOUDWHVWR.QDXI'LUHFWIURPZLWKLQWKH*HUPDQODQGOLQHQHWZRUNʑSHU0LQ&DOOHUVZKRVHSKRQHQXPEHUVDUHQRWUHJLVWHUHGLQWKH.QDXIDGGUHVVGDWDEDVHHJSULYDWH EXLOGHUVRUQRQSDWURQVDUHFKDUJHGʑ0LQ&DOOVIURPPRELOHSKRQHVPD\GLIIHUDQGZLOOEHFKDUJHGDFFWRQHWSURYLGHUDQGFDOOUDWH )D[ʑ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ÀFDWLRQVDQGFKDUDFWHULVWLFVRIEXLOGLQJSK\VLFVRI.QDXIV\VWHPVFDQ RQO\EHDFKLHYHGZLWKWKHH[FOXVLYHXVHRI.QDXIV\VWHPFRPSRQHQWVRURWKHUSURGXFWVH[SUHVVO\UHFRPPHQGHGE\.QDXI