13⁄32”x 11⁄2” Fast

advertisement
Low Voltage Supplementary Fuses
13
⁄32” x 11⁄2” Fast-acting fuses
BAF
BAN
KTK & KLM
BAN-4
Catalog Numbers (Amps)
BAF-2⁄10
BAF-2
BAF-8
BAF-1⁄4
BAF-2 1⁄2
BAF-9
BAF- ⁄2
BAF-3
BAF-10
BAF-6⁄10
BAF-4
BAF-12
BAF-8⁄10
BAF-5
BAF-15
BAF-1
BAF-6
1
BAF-20
BAN-10
600Vac - UL Listed and CSA
KTK-4
KTK-12
KTK- ⁄8
KTK-1
KTK-5
KTK-15
KTK- 2⁄10
KTK-1 1⁄4
KTK-6
KTK-20
KTK- 1⁄4
KTK-1 1⁄2
KTK-7
KTK-25
KTK- 3⁄10
KTK-2
KTK-7 1⁄2
KTK-30
Poles
KTK- 4⁄10
KTK-2 1⁄2
KTK-8
KTK-35
1
BM6031SQ
BM6031PQ
BM6031B
1
KTK- 1⁄2
KTK-3
KTK-9
KTK-40
BM6032PQ
BM6032B
2
KTK- 6⁄10
KTK-3 1⁄2
KTK-10
KTK-45
BM6033PQ
BM6033B
3
BAF-1 ⁄2
BAF-6 ⁄4
BAF-25
BAF-1 8⁄10
BAF-7
BAF-30
BM6033SQ
1
Pressure Plate w/
Quick Connect
Box Lug
Typical Applications
• Control Circuits
• Lighting Circuit Protection
• Meter Circuits
Catalog Numbers (Amps)
KTK- 3⁄4
Catalog Numbers
Terminal Type
Screw with
Quick Connect
Features and Benefits
• Low cost supplemental protection of 600V
or less non-inductive circuits.
• Upgrade with LP-CC product to reduce
SKU investment and minimize potential
arc-flash hazards.
KTK-1⁄10
Recommended Fuse blocks 1⁄10 to 30A
BM6032SQ
1
BAN-25
Specifications
Class: Supplemental
Description: Fastacting supplementary
fuse.
Dimensions: 13⁄32” x
1 1⁄2 (10.3 x 38.1mm).
Construction:
Melamine tube; nickel
plated brass endcaps.
Ratings:
Volts — KTK: 600Vac (or less)
— KLM: 500Vac/600Vdc (1⁄10A to 1⁄8A)
— 500Vac/dc (2⁄10-10A)
— 500Vac/600Vdc (12-30A)
Amps — 1⁄10-30A
IR — KTK: 100,000A RMS Sym. (UL)
— KLM: 10,000A RMS Sym. (UL)
Agency Information: CE, Std. 248-14,
KTK-UL Listed, Guide JDYX, File E19180,
KLM-UL Recognized, Guide JFHR2, File
E56412, CSA Certified, File 53787, Class
1422-01, HRC-Misc.
KTK-50
*500Vac/dc - UL Recognized and CSA.
*All have interrupting rating of 10,000A at 125V.
Data Sheet: 2011 (0-30)
Data Sheet: 2046 (0-30)
For superior electrical protection, Cooper Bussmann recommends upgrading BAF,
BAN and KTK fuse applications to Low-Peak LP-CC fuses See page 19.
Recommended fuse blocks/fuse holders for 13⁄32” x 11⁄2” fuses
• See page 40
KLM-1⁄10
KLM- 3⁄4
KLM-5
KLM- 1⁄8
KLM-1
KLM-6
KLM-20
KLM-25
KLM- 2⁄10
KLM-1 1⁄2
KLM-8
KLM-30
KLM- 1⁄4
KLM-2
KLM-10
KLM- 3⁄10
KLM-3
KLM-12
KLM- 1⁄2
KLM-4
KLM-15
*KLM-( 1⁄10- 1⁄8A & 12-30A): 500Vac/600Vdc.
Data Sheets: KTK-1011 KLM-2020
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
43
Low Voltage
Supplementary
Fuses
Specifications
Specifications
Class: Supplemental
Class: Supplemental
Description: Fast-acting
Description: Fast-acting
supplementary fuse.
supplementary fuse.
Dimensions: 13⁄32” x 1 1⁄2
Dimensions: 13⁄32” x 1 1⁄2
(10.3 x 38.1mm).
(10.3 x 38.1mm).
Construction: Fibre
Construction: Fibre tube.
cartridge; nickel plated
Ratings:
brass endcaps.
Volts — 250Vac
Ratings:
Amps — 1-30A
Volts — 250Vac (2⁄10-15A)
IR — 35A (1.1-3.5A)
— 125Vac (20-30A)
— 100A (3.6-10A)
Amps — 1-6A
— 200A (10.1-15A)
IR — 10,000A @ 125Vac (2⁄10-30A)
— 750A (15.1-30A)
— 35A (2⁄10-1A @ 250Vac)
Features and Benefits
— 100A (11⁄2-6A @ 250Vac)
• Low cost supplemental protection of
1
— 200A (6 ⁄4-10A @ 250Vac)
125V and 250V non-inductive
— 750A (12A- 15A @ 250Vac)
circuits.
Agency Information: CE, Std. 248-14, • Upgrade with LP-CC product to
UL 0-15/250V, Guide JDYX, File E19180
reduce SKU investment and miniCSA Certified, 0-15/250V, Class
mize potential arc-flash hazards.
1422-01, File 53787.
(and
minimize potential for misapplying
Features and Benefits
fuse.)
• Low cost supplemental protection of
125V and 250V non-inductive circuits.
Typical Applications
• Upgrade with LP-CC product to reduce • General Purpose Circuits
SKU investment and minimize potential • Lighting Circuit Protection
arc-flash hazards. (and minimize
• Meter Circuits
potential for misapplying fuse.)
Catalog Numbers (Amps)
Typical Applications
BAN-1
BAN-5
BAN-12
BAN-30
• General Purpose Circuits
BAN-2
BAN-6
BAN-15
• Lighting Circuit Protection
BAN-3
BAN-8
BAN-20
• Meter Circuits
Low Voltage Supplementary Fuses
13
⁄32” x 11⁄2” Time-delay fuses
FNQ
Specifications
Class: Supplemental
Description: Time-delay
supplementary fuse.
Dimensions: 13⁄32” x 11⁄2”
(10.3 x 38.1mm).
Construction: Fiber tube.
Ratings:
Volts — 250Vac (or less)
Amps — 1⁄10-30A
IR — 35A (1⁄10-1A @ 250Vac)
— 100A (11⁄8-31⁄2A @ 250Vac)
— 200A (4-10A @ 250Vac)
— 10,000A (1⁄10-15A @ 125Vac)
— N/A (20-30A @ 32Vac)
NOTE: For 250V applications from 12-30A use FNW.
Agency Information: CE, Std. 248-14, UL Listed,
0-10/250V; 12-15/125V; File E19180, Guide JDYX, CSA
Certified, 1-10/250V; Class 1422-01, 12-15/125V; File 53787.
Specifications
Class: Supplemental
Description: Time-delay supplementary
fuse.
Dimensions: 13⁄32” x 11⁄2 (10.3 x 38.1mm).
Construction: Fiber tube.
Ratings:
Volts — 500Vac (or less)
Amps — 1⁄10-30A
IR — 10,000A RMS Sym.
Agency Information: CE, Std. 248-14, UL Listed, Guide
JDYX, File E19180 CSA Certified, Class 1422-01, File
53787.
Features and Benefits
• Low cost supplemental protection of 125V and 250V
inductive circuits.
Features and Benefits
• Low cost supplemental protection of transformers and relays
at 500V or less.
Typical Applications
• Control Transformer 480V Primary Protection
• Lighting Circuit Protection
• Meter Circuits
Catalog Numbers (Amps)
Typical Applications
• General Purpose Circuits
• Lighting Circuit Protection
• Meter Circuits
• Upgrading to LP-CC product will reduce SKU investment
and minimize potential for misapplying fuse.
FNQ-1⁄10
FNQ-4⁄10
FNQ-1 1⁄2
FNQ-3 1⁄2
FNQ-7
FNQ-20
FNQ- ⁄8
FNQ- ⁄2
FNQ-1 ⁄10
FNQ-4
FNQ-8
FNQ-25
FNQ-15⁄100
FNQ-6⁄10
FNQ-2
FNQ-4 1⁄2
FNQ-9
FNQ-30
FNQ-3⁄16
FNQ-8⁄10
FNQ-2 1⁄4
FNQ-5
FNQ-10
FNQ-2⁄10
FNQ-1
FNQ-2 1⁄2
FNQ-5 6⁄10
FNQ-12
FNQ-1⁄4
FNQ-1 1⁄8
FNQ-3
FNQ-6
FNQ-14
FNQ-3⁄10
FNQ-1 1⁄4
FNQ-3 2⁄10
FNQ-6 1⁄4
FNQ-15
1
1
6
Catalog Numbers (Amps)
FNM-1⁄10
FNM-1⁄2
FNM-1 1⁄2
FNM-3k
FNM-6
FNM-15
FNM-1⁄8
FNM-6⁄10
FNM-1 6⁄10
FNM-3 2⁄10
FNM-6 1⁄4
FNM-20
FNM- ⁄100
FNM- ⁄4
FNM-1 ⁄10
FNM-3 ⁄2
FNM-7
FNM-25
FNM-2⁄10
FNM-1
FNM-2
FNM-4
FNM-8
FNM-30
FNM-1⁄4
FNM-1 1⁄8
FNM-2 1⁄4
FNM-4 1⁄2
FNM-9
FNM- ⁄10
FNM-1 ⁄4
FNM-2 ⁄2
FNM-5
FNM-10
FNM-4⁄10
FNM-1 4⁄10
FNM-2 8⁄10
FNM-5 6⁄10
FNM-12
15
3
3
8
1
1
1
For superior electrical protection, Cooper Bussmann recommends upgrading
FNM and FNQ fuse applications to Low-Peak LP-CC fuses See page 19.
Recommended fuse blocks and fuse holders for
13
⁄32” x 11⁄2” fuses
• See page 40
Data Sheet: 2028
Data Sheet: 1012
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
45
Low Voltage
Supplementary
Fuses
FNM
Fuse Holders and Blocks
Global modular fuse holders
Recommended Cooper Bussmann® Fuse Types
— 8x32 IEC ferrule - C08 Series
— 10x38 North American Class CC Fuses - LP-CC,
FNQ-R, KTK-R
Fuses - FNQ, KTK, AGU, KM, BAF, BAN,
GNM, FWA, FWC, C10 Series
— 14x51 Fuses - FWX, FWH, FWP & NON, C14
Series
— 22x58 Fuses - FWP, C22 Series
High Speed Fuses For Semiconductor Protection
The ‘CH’ range of modular fuse holders may be used in conjunction with Class gR and aR high-speed fuses, offering a
touch-safe design with no exposed contacts. See Data Sheet
2143 for details. Contact Cooper Bussmann Application
Engineering for more information regarding high-speed fuse
application.
Did You Know?
Cooper Bussmann® Optima® OPM-NG
Wins Product of the Year Award
Accessories for CH Series
Catalog
Numbers
AL-D
For Use with
Fuse Holders
CH08, CHM,
CHCC, AND
CH14 Series
CH810-HP
Multi-Phase Handle Pins
CH08, CHM,&
CHCC Series
Multi-Phase Handle Pins
CH14-HP
CH14 Series
C08NL
Neutral Links
CH08 Series
C10NL, NNB
CHM Series
NNB-R
CHCC Series
Neutral Links
C14NL
CH14 Series
C22NL
CH22 Series
CH14MS-1D
Operated-Fuse Micro-Switches CH141 Series
CH14MS-3D Operated-Fuse Micro-Switches CH143 Series
Accessory
Multi-Phase Connection Links
Multi-Phase Connection Links
Multi-Phase
Connection Links
No. of
Poles
1
3
Multi-Phase
Handle Pins
Box
Qty.
12
12
12
12
12
12
10
10
10
10
10
5
2
As voted by the readers of Plant Engineering
Magazine, the Cooper Bussmann® Optima®
OPM-NG modular fuseholder won a Product of the
Year Award (Silver) in the power products category.
This prestigious honor recognizes innovative
products used by electrical, engineering and
maintenance professionals to improve safety and
increase productivity.
The OPM-NG fuseholder’s design incorporates
IP-20 finger-safe construction with integral DIN rail
spring mounting — requiring no tools – so
installation is fast and easy. When the OPM-NG is
used in motor starter applications, wiring time in
group installations can be reduced by up to 80
percent.
The compact 45 mm width matches the OPM-NG
with 32A/45 mm IEC motor starter requirements.
The low profile handle is integral with the fuse
carrier and acts as a built-in fuse puller. This
eliminates the inconvenience of needing an extra
tool to remove the fuses.
Operated-Fuse
Micro-Switches
240
Neutral Links
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
Fuse Holders and Blocks
Rail mount fuse holders
NDNF1-WH
NDNLFD1
Specifications
Specifications
Description: Rail mount fuse
holder.
Circuit Jumper: JF1,
2 circuits
Fuse Size: 13⁄32" X 11⁄2"
(KTK, FNQ).
Poles: 1
Wire Range: AWG #8-22 CU.
Ratings:
Volts: — 600V
Amps: — 30A
Agency Information: UL E62622; CSA LR15364.
Flammability Rating: UL 94V2.
Marking Tape: MT12-1⁄2.
Torque Rating: 18 in-lb max.
Mounting Options: 35mm DIN rail, C-rail.
Description: Rail mount
fuse holder.
Circuit Jumper: JF1,
2 circuits.
Fuse Size: 1⁄4" X 11⁄4"
(Cooper Bussmann AGC,
MDL or equivalent).
Poles: 1
Wire Range: AWG #8-22 CU.
Ratings:
Volts: — 600V
Amps: — 30A (NDND1 non-fused)
— 15A (NDNFD1, 600V/CSA, fused)
— 15A (NDNLFD1*fused, indicating)
Catalog Numbers
Number
Color
NDNF1-WH
White
Agency Information: CE, UL E62622; CSA LR15364.
Flammability Rating: UL 94V2.
Marking Tape: MT12-1⁄2
Torque Rating: 18 in-lb max.
Mounting Options: 35mm DIN rail, C-rail.
Fuse Pullers (Optional): PF1
Lighted neon or incandescent lamp:
Catalog Numbers
Catalog
Catalog
Number
Color
Indicator
Numbers
Voltage
NDNFD1-WH
White
NO
LPF1-24
24
NDNLFD1-WH
White
LPF1-120
120
90Vdc-600Vdc
115Vac-600Vac
LPF1-120-C
120
NDNLFD1-WH 24
White
24V
LPF1-220
220
LPF1-440
440
Data Sheet: 1133
Fuse
Holders
& Blocks
Catalog
*WH24 - 24V White, WH-90Vdc-600Vdc, 115Vac-600Vac White
Extension: WH - White
(Only available with NDNLFD1)
Data Sheet: 1133
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
273
Download