Low Voltage Supplementary Fuses 13 ⁄32” x 11⁄2” Fast-acting fuses BAF BAN KTK & KLM BAN-4 Catalog Numbers (Amps) BAF-2⁄10 BAF-2 BAF-8 BAF-1⁄4 BAF-2 1⁄2 BAF-9 BAF- ⁄2 BAF-3 BAF-10 BAF-6⁄10 BAF-4 BAF-12 BAF-8⁄10 BAF-5 BAF-15 BAF-1 BAF-6 1 BAF-20 BAN-10 600Vac - UL Listed and CSA KTK-4 KTK-12 KTK- ⁄8 KTK-1 KTK-5 KTK-15 KTK- 2⁄10 KTK-1 1⁄4 KTK-6 KTK-20 KTK- 1⁄4 KTK-1 1⁄2 KTK-7 KTK-25 KTK- 3⁄10 KTK-2 KTK-7 1⁄2 KTK-30 Poles KTK- 4⁄10 KTK-2 1⁄2 KTK-8 KTK-35 1 BM6031SQ BM6031PQ BM6031B 1 KTK- 1⁄2 KTK-3 KTK-9 KTK-40 BM6032PQ BM6032B 2 KTK- 6⁄10 KTK-3 1⁄2 KTK-10 KTK-45 BM6033PQ BM6033B 3 BAF-1 ⁄2 BAF-6 ⁄4 BAF-25 BAF-1 8⁄10 BAF-7 BAF-30 BM6033SQ 1 Pressure Plate w/ Quick Connect Box Lug Typical Applications • Control Circuits • Lighting Circuit Protection • Meter Circuits Catalog Numbers (Amps) KTK- 3⁄4 Catalog Numbers Terminal Type Screw with Quick Connect Features and Benefits • Low cost supplemental protection of 600V or less non-inductive circuits. • Upgrade with LP-CC product to reduce SKU investment and minimize potential arc-flash hazards. KTK-1⁄10 Recommended Fuse blocks 1⁄10 to 30A BM6032SQ 1 BAN-25 Specifications Class: Supplemental Description: Fastacting supplementary fuse. Dimensions: 13⁄32” x 1 1⁄2 (10.3 x 38.1mm). Construction: Melamine tube; nickel plated brass endcaps. Ratings: Volts — KTK: 600Vac (or less) — KLM: 500Vac/600Vdc (1⁄10A to 1⁄8A) — 500Vac/dc (2⁄10-10A) — 500Vac/600Vdc (12-30A) Amps — 1⁄10-30A IR — KTK: 100,000A RMS Sym. (UL) — KLM: 10,000A RMS Sym. (UL) Agency Information: CE, Std. 248-14, KTK-UL Listed, Guide JDYX, File E19180, KLM-UL Recognized, Guide JFHR2, File E56412, CSA Certified, File 53787, Class 1422-01, HRC-Misc. KTK-50 *500Vac/dc - UL Recognized and CSA. *All have interrupting rating of 10,000A at 125V. Data Sheet: 2011 (0-30) Data Sheet: 2046 (0-30) For superior electrical protection, Cooper Bussmann recommends upgrading BAF, BAN and KTK fuse applications to Low-Peak LP-CC fuses See page 19. Recommended fuse blocks/fuse holders for 13⁄32” x 11⁄2” fuses • See page 40 KLM-1⁄10 KLM- 3⁄4 KLM-5 KLM- 1⁄8 KLM-1 KLM-6 KLM-20 KLM-25 KLM- 2⁄10 KLM-1 1⁄2 KLM-8 KLM-30 KLM- 1⁄4 KLM-2 KLM-10 KLM- 3⁄10 KLM-3 KLM-12 KLM- 1⁄2 KLM-4 KLM-15 *KLM-( 1⁄10- 1⁄8A & 12-30A): 500Vac/600Vdc. Data Sheets: KTK-1011 KLM-2020 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 43 Low Voltage Supplementary Fuses Specifications Specifications Class: Supplemental Class: Supplemental Description: Fast-acting Description: Fast-acting supplementary fuse. supplementary fuse. Dimensions: 13⁄32” x 1 1⁄2 Dimensions: 13⁄32” x 1 1⁄2 (10.3 x 38.1mm). (10.3 x 38.1mm). Construction: Fibre Construction: Fibre tube. cartridge; nickel plated Ratings: brass endcaps. Volts — 250Vac Ratings: Amps — 1-30A Volts — 250Vac (2⁄10-15A) IR — 35A (1.1-3.5A) — 125Vac (20-30A) — 100A (3.6-10A) Amps — 1-6A — 200A (10.1-15A) IR — 10,000A @ 125Vac (2⁄10-30A) — 750A (15.1-30A) — 35A (2⁄10-1A @ 250Vac) Features and Benefits — 100A (11⁄2-6A @ 250Vac) • Low cost supplemental protection of 1 — 200A (6 ⁄4-10A @ 250Vac) 125V and 250V non-inductive — 750A (12A- 15A @ 250Vac) circuits. Agency Information: CE, Std. 248-14, • Upgrade with LP-CC product to UL 0-15/250V, Guide JDYX, File E19180 reduce SKU investment and miniCSA Certified, 0-15/250V, Class mize potential arc-flash hazards. 1422-01, File 53787. (and minimize potential for misapplying Features and Benefits fuse.) • Low cost supplemental protection of 125V and 250V non-inductive circuits. Typical Applications • Upgrade with LP-CC product to reduce • General Purpose Circuits SKU investment and minimize potential • Lighting Circuit Protection arc-flash hazards. (and minimize • Meter Circuits potential for misapplying fuse.) Catalog Numbers (Amps) Typical Applications BAN-1 BAN-5 BAN-12 BAN-30 • General Purpose Circuits BAN-2 BAN-6 BAN-15 • Lighting Circuit Protection BAN-3 BAN-8 BAN-20 • Meter Circuits Low Voltage Supplementary Fuses 13 ⁄32” x 11⁄2” Time-delay fuses FNQ Specifications Class: Supplemental Description: Time-delay supplementary fuse. Dimensions: 13⁄32” x 11⁄2” (10.3 x 38.1mm). Construction: Fiber tube. Ratings: Volts — 250Vac (or less) Amps — 1⁄10-30A IR — 35A (1⁄10-1A @ 250Vac) — 100A (11⁄8-31⁄2A @ 250Vac) — 200A (4-10A @ 250Vac) — 10,000A (1⁄10-15A @ 125Vac) — N/A (20-30A @ 32Vac) NOTE: For 250V applications from 12-30A use FNW. Agency Information: CE, Std. 248-14, UL Listed, 0-10/250V; 12-15/125V; File E19180, Guide JDYX, CSA Certified, 1-10/250V; Class 1422-01, 12-15/125V; File 53787. Specifications Class: Supplemental Description: Time-delay supplementary fuse. Dimensions: 13⁄32” x 11⁄2 (10.3 x 38.1mm). Construction: Fiber tube. Ratings: Volts — 500Vac (or less) Amps — 1⁄10-30A IR — 10,000A RMS Sym. Agency Information: CE, Std. 248-14, UL Listed, Guide JDYX, File E19180 CSA Certified, Class 1422-01, File 53787. Features and Benefits • Low cost supplemental protection of 125V and 250V inductive circuits. Features and Benefits • Low cost supplemental protection of transformers and relays at 500V or less. Typical Applications • Control Transformer 480V Primary Protection • Lighting Circuit Protection • Meter Circuits Catalog Numbers (Amps) Typical Applications • General Purpose Circuits • Lighting Circuit Protection • Meter Circuits • Upgrading to LP-CC product will reduce SKU investment and minimize potential for misapplying fuse. FNQ-1⁄10 FNQ-4⁄10 FNQ-1 1⁄2 FNQ-3 1⁄2 FNQ-7 FNQ-20 FNQ- ⁄8 FNQ- ⁄2 FNQ-1 ⁄10 FNQ-4 FNQ-8 FNQ-25 FNQ-15⁄100 FNQ-6⁄10 FNQ-2 FNQ-4 1⁄2 FNQ-9 FNQ-30 FNQ-3⁄16 FNQ-8⁄10 FNQ-2 1⁄4 FNQ-5 FNQ-10 FNQ-2⁄10 FNQ-1 FNQ-2 1⁄2 FNQ-5 6⁄10 FNQ-12 FNQ-1⁄4 FNQ-1 1⁄8 FNQ-3 FNQ-6 FNQ-14 FNQ-3⁄10 FNQ-1 1⁄4 FNQ-3 2⁄10 FNQ-6 1⁄4 FNQ-15 1 1 6 Catalog Numbers (Amps) FNM-1⁄10 FNM-1⁄2 FNM-1 1⁄2 FNM-3k FNM-6 FNM-15 FNM-1⁄8 FNM-6⁄10 FNM-1 6⁄10 FNM-3 2⁄10 FNM-6 1⁄4 FNM-20 FNM- ⁄100 FNM- ⁄4 FNM-1 ⁄10 FNM-3 ⁄2 FNM-7 FNM-25 FNM-2⁄10 FNM-1 FNM-2 FNM-4 FNM-8 FNM-30 FNM-1⁄4 FNM-1 1⁄8 FNM-2 1⁄4 FNM-4 1⁄2 FNM-9 FNM- ⁄10 FNM-1 ⁄4 FNM-2 ⁄2 FNM-5 FNM-10 FNM-4⁄10 FNM-1 4⁄10 FNM-2 8⁄10 FNM-5 6⁄10 FNM-12 15 3 3 8 1 1 1 For superior electrical protection, Cooper Bussmann recommends upgrading FNM and FNQ fuse applications to Low-Peak LP-CC fuses See page 19. Recommended fuse blocks and fuse holders for 13 ⁄32” x 11⁄2” fuses • See page 40 Data Sheet: 2028 Data Sheet: 1012 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 45 Low Voltage Supplementary Fuses FNM Fuse Holders and Blocks Global modular fuse holders Recommended Cooper Bussmann® Fuse Types — 8x32 IEC ferrule - C08 Series — 10x38 North American Class CC Fuses - LP-CC, FNQ-R, KTK-R Fuses - FNQ, KTK, AGU, KM, BAF, BAN, GNM, FWA, FWC, C10 Series — 14x51 Fuses - FWX, FWH, FWP & NON, C14 Series — 22x58 Fuses - FWP, C22 Series High Speed Fuses For Semiconductor Protection The ‘CH’ range of modular fuse holders may be used in conjunction with Class gR and aR high-speed fuses, offering a touch-safe design with no exposed contacts. See Data Sheet 2143 for details. Contact Cooper Bussmann Application Engineering for more information regarding high-speed fuse application. Did You Know? Cooper Bussmann® Optima® OPM-NG Wins Product of the Year Award Accessories for CH Series Catalog Numbers AL-D For Use with Fuse Holders CH08, CHM, CHCC, AND CH14 Series CH810-HP Multi-Phase Handle Pins CH08, CHM,& CHCC Series Multi-Phase Handle Pins CH14-HP CH14 Series C08NL Neutral Links CH08 Series C10NL, NNB CHM Series NNB-R CHCC Series Neutral Links C14NL CH14 Series C22NL CH22 Series CH14MS-1D Operated-Fuse Micro-Switches CH141 Series CH14MS-3D Operated-Fuse Micro-Switches CH143 Series Accessory Multi-Phase Connection Links Multi-Phase Connection Links Multi-Phase Connection Links No. of Poles 1 3 Multi-Phase Handle Pins Box Qty. 12 12 12 12 12 12 10 10 10 10 10 5 2 As voted by the readers of Plant Engineering Magazine, the Cooper Bussmann® Optima® OPM-NG modular fuseholder won a Product of the Year Award (Silver) in the power products category. This prestigious honor recognizes innovative products used by electrical, engineering and maintenance professionals to improve safety and increase productivity. The OPM-NG fuseholder’s design incorporates IP-20 finger-safe construction with integral DIN rail spring mounting — requiring no tools – so installation is fast and easy. When the OPM-NG is used in motor starter applications, wiring time in group installations can be reduced by up to 80 percent. The compact 45 mm width matches the OPM-NG with 32A/45 mm IEC motor starter requirements. The low profile handle is integral with the fuse carrier and acts as a built-in fuse puller. This eliminates the inconvenience of needing an extra tool to remove the fuses. Operated-Fuse Micro-Switches 240 Neutral Links For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp Fuse Holders and Blocks Rail mount fuse holders NDNF1-WH NDNLFD1 Specifications Specifications Description: Rail mount fuse holder. Circuit Jumper: JF1, 2 circuits Fuse Size: 13⁄32" X 11⁄2" (KTK, FNQ). Poles: 1 Wire Range: AWG #8-22 CU. Ratings: Volts: — 600V Amps: — 30A Agency Information: UL E62622; CSA LR15364. Flammability Rating: UL 94V2. Marking Tape: MT12-1⁄2. Torque Rating: 18 in-lb max. Mounting Options: 35mm DIN rail, C-rail. Description: Rail mount fuse holder. Circuit Jumper: JF1, 2 circuits. Fuse Size: 1⁄4" X 11⁄4" (Cooper Bussmann AGC, MDL or equivalent). Poles: 1 Wire Range: AWG #8-22 CU. Ratings: Volts: — 600V Amps: — 30A (NDND1 non-fused) — 15A (NDNFD1, 600V/CSA, fused) — 15A (NDNLFD1*fused, indicating) Catalog Numbers Number Color NDNF1-WH White Agency Information: CE, UL E62622; CSA LR15364. Flammability Rating: UL 94V2. Marking Tape: MT12-1⁄2 Torque Rating: 18 in-lb max. Mounting Options: 35mm DIN rail, C-rail. Fuse Pullers (Optional): PF1 Lighted neon or incandescent lamp: Catalog Numbers Catalog Catalog Number Color Indicator Numbers Voltage NDNFD1-WH White NO LPF1-24 24 NDNLFD1-WH White LPF1-120 120 90Vdc-600Vdc 115Vac-600Vac LPF1-120-C 120 NDNLFD1-WH 24 White 24V LPF1-220 220 LPF1-440 440 Data Sheet: 1133 Fuse Holders & Blocks Catalog *WH24 - 24V White, WH-90Vdc-600Vdc, 115Vac-600Vac White Extension: WH - White (Only available with NDNLFD1) Data Sheet: 1133 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 273