EXAMPLE LHS4-454-M4R-4EPU FEATURES LHS 4 ORDERING

advertisement
LHS4
Slim Body Linear High Bay / 4 or 6-Lamp T5HO, T8
PROJECT INFORMATION
Project Name
Type
Catalog No.
Date
HOUSING
FINISH
22 gauge riveted steel housing
Painted parts are treated with a five stage
phosphate bonding process and finished with a
high reflectance baked white enamel. End caps are
painted after fabrication as standard.
BALLASTS
FEATURES
•
•
•
•
Used in high and low bay, aisle and task lighting applications
Ideal for mounting heights ranging 8 to 40 feet
Rugged 22 gauge riveted full body steel housing
95% specular aluminum reflectors for precise control or
finished white reflectors available for wide light distribution
• Tool-less ballast access for easy service
• V-hangers included for chain hanging
Energy efficient, thermally protected, automatic
resetting, Class P, high power factor, sound rated
A, unless otherwise specified. CEE NEMA Premium
compliant.
REFLECTOR
Choice of 95% specular aluminum or finished white
aluminum.
ELECTRICAL
Standard class “P,” thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA
Premium compliant. All ballast leads extend a
minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard.
CERTIFICATION
All luminaires are built to UL 1598 standards and
bear appropriate UL and cUL or CSA labels. Damp
location labeling is standard.
ORDERING INFORMATION
LHS
4
MODEL
–
4 Four
6 Six
LAMP TYPE
32 4', T8: 32, 30, 28,
or 25 Watt
54 4', T5HO: 54, 51,
or 49 Watt
SIZE
REFLECTOR
4 4'
M4R Aluminum 95%
Reflective, Specular Silver
(Narrow Beam)
GW Gloss White (Wide Beam)
ACCESSORIES (ORDER SEPARATELY)
LHTG5
LHTG10
LHS432WGK
LHS454WGK
LHS632WGK
LHS654WGK
GLH5
GLH10
GLH15
OS1360K
U
–
NO. OF LAMPS IN
CROSS SECTION
LHS Slim Body Linear
High Bay
EXAMPLE LHS4-454-M4R-4EPU
Y-Fit Toggle Hanger, 5' Adjustable, Pair
Y-Fit Toggle Hanger, 10' Adjustable, Pair
Wire Guard for 4-Lamp T8 Fixture
Wire Guard for 4-Lamp T5HO Fixture
Wire Guard for 6-Lamp T8 Fixture
Wire Guard for 6-Lamp T5HO Fixture
5', Adjustable Cable Kit
10', Adjustable Cable Kit
15', Adjustable Cable Kit
Occupancy/Daylight sensor kit, 120/277/347V, one
relay, 360 Lens, snap on drop down adaptor, quick
connect wiring*
OS2360K Occupancy/Daylight sensor kit, 120/277/347V, two
relay, 360 Lens, snap on drop down adaptor, quick
connect wiring*
*Use programmed start ballast. Not recommended for use with
an instant start. For more occupancy/daylight harvesting sensor
accessories contact your Columbia Lighting representative.
BALLAST
T8
4EHL (1) 4-Lamp Electronic T8 High
Light Output, Instant Start
3EHL (2) 3-Lamp Electronic T8 High
Light Output, Instant Start
4EPHL (1) 4-Lamp Electronic T8 High
Light Output, Programmed Start
3EPHL (2) 3-Lamp Electronic T8 High
Light Output, Programmed Start
T5HO
4EP (1) 4-Lamp Electronic T5HO,
Programmed Start
24EP (1) 4-Lamp and (1) 2-Lamp
Electronic T5HO, Programmed
Start
Page 1/2 Rev. 12/09/14
© 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
–
VOLTAGE
OPTIONS
U 120V-277V
F3C5 3-Conductor Cord
F4C5 4-Conductor Cord
C8TL15_ 8' Cord and Twist-Lock™
Plug 15A (Add Voltage:
1=120, 2=277)
C8P151 8' Cord and Straight Blade
Plug 15A
EL Emergency Battery Pack,
T8 1100-1200 Lumens, 1
Lamp or T5HO 1150 Lumens,
1 Lamp
WG Cage Type Wire Guard
LAMPS INSTALLED
T8
FO841
FO850
T5HO
F5841
F5850
85 CRI, 4100K
85 CRI, 5000K
85 CRI, 4100K
85 CRI, 5000K
INDUSTRIALS / LHS4
LHS4
Slim Body Linear High Bay / 4 or 6-Lamp T5HO, T8
PHOTOMETRIC DATA
Test 19448 Test Date 04/13/09
Ballast
Ballast Factor
Lamp
Lumens per
Lamp
Watts
Mounting
Shielding
Angle
Spacing
Criterion
Luminous
Opening in
Feet
LHS4-632-M4R-3EU
Linear Fluorescent
High Bay Industrial
17"× 48", 6-lamp
T8 with specular
reflectors
(2) GE-332-MAX-H/
ULTRA
1.18
F32T8
2950
Average Luminance Angle
Luminaire
AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%)
217
Suspended
0º = 0 90º = 0
0
30
40
45
50
55
60
65
70
75
80
85
0.0
22.5
45.0 67.5
8963
8675
8373
8166
7913
7595
7203
6712
6081
5261
4125
2577
8963
9289
9910
10184
10353
10392
10197
9532
8359
7622
9496
9704
8963
11051
11558
11463
10866
10085
9263
9604
11287
12399
12607
13024
8963
11787
11637
10988
10205
9694
10687
12203
13358
13743
13854
15346
90.0
RC
80
RW 70 50 30
8963
1 98 94 89
11955
2 89 81 74
11471
3 81 70 62
10762
4 74 62 54
10013
5 68 55 47
10050
6 62 49 41
11602
7 58 45 36
12874
8 54 41 33
13754
9 50 37 29
14079
10 47 34 27
14262
16112 RCR = Room Cavity Ratio
RCR
LUMINAIRE DATA
10
85
68
56
47
40
35
31
27
24
22
70
96
86
78
71
65
60
56
52
49
45
70
50 30
91 87
79 73
69 61
61 53
54 46
49 40
44 36
40 32
37 29
34 27
10
84
67
55
47
40
35
30
27
24
22
50
87
75
66
58
52
47
42
39
35
33
INDOOR CANDELA PLOT
50
30
84
70
60
51
45
40
35
32
29
26
10
81
66
54
46
39
34
30
27
24
22
180
0
0
74
60
50
42
36
31
28
24
22
20
165
150
135
5200
120
2600
105
90
75
2600
60
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
ZONAL LUMEN SUMMARY
0º = 1.24 90º = 1.57
Length: 4.00
Width: 1.33
Height: 0.00
5200
ENERGY DATA
Zone
Lumens
Lamp
Fixt.
Total Luminaire Efficiency
0-30
0-40
0-60
0-90
0-180
3822
6549
11875
16051
16244
21.6
37.0
67.1
90.7
91.8
23.5
40.3
73.1
98.8
100.0
Luminaire Efficacy Rating (LER)
IESNA RP-1-2004 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
0
91.8%
15
0.0
88
Non-Compliant
$2.73 based on 3000 hrs.
and $0.08 per KWH
30
Horiz 0-180
45
45.0
90.0
Test 22716 Test Date 04/13/09
Ballast
Ballast Factor
Lamp
Lumens per
Lamp
Watts
Shielding
Angle
Spacing
Criterion
Luminous
Opening in
Feet
LHS4-454-M4R4EPU
Linear Fluorescent
High Bay Industrial
12" × 48", 4-lamp
T5HO with specular
reflectors
ICN-4S54-90C-2LS-G
1.00
F54T5HO
4500
Average Luminance Angle
Luminaire
AVG. LUMINANCE (Candela/Sq. M.)
226
0º = 0 90º = 0
0º = 1.21 90º = 1.05
Length: 4.00
Width: 0.92
Height: 0.00
0
30
40
45
50
55
60
65
70
75
80
85
0.0
22.5
45.0
67.5 90.0
18928
17776
16991
16476
15840
15039
14046
12776
11066
8872
6232
3121
18928
17104
15640
14747
13838
12948
11823
10319
8997
8487
9601
12518
18928
15776
14273
13204
12004
11178
10869
11150
12315
14895
18495
19399
18928
15178
13078
12124
11708
11647
12250
13531
15924
19416
22066
22386
18928
14966
12677
12008
11827
12081
12958
14541
17318
20704
22993
23023
ZONAL LUMEN SUMMARY
COEFFICIENTS OF UTILIZATION (%)
RCR
LUMINAIRE DATA
RC
RW
1
2
3
4
5
6
7
8
9
10
70
94
86
78
72
66
61
57
53
50
47
80
50 30
90 86
78 72
69 62
61 54
55 47
50 42
45 38
42 34
38 31
35 29
10
82
67
56
48
41
36
32
29
26
24
70
92
83
76
70
65
60
56
52
49
46
70
50 30
88 84
77 71
68 61
60 53
54 47
49 42
45 37
41 34
38 31
35 28
10
81
66
56
47
41
36
32
29
26
24
50
84
74
65
58
52
47
43
40
37
34
50
30
81
69
59
52
46
41
37
33
31
28
INDOOR CANDELA PLOT
10
79
65
55
47
41
36
32
29
26
24
90
0
0
72
60
51
44
38
34
30
27
24
22
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
75
3300
60
6600
0
15
0.0
30
Horiz 0-180
45.0
45
90.0
ENERGY DATA
Zone
Lumens
Lamp
Fixt.
Total Luminaire Efficiency
87.3%
0-30
0-40
0-60
0-90
0-180
4687
7372
12087
15715
15715
26.0
41.0
67.1
87.3
87.3
29.8
46.9
76.9
100.0
100.0
Luminaire Efficacy Rating (LER)
IESNA RP-1-2004 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
70
Noncompliant
$3.43 based on 3000 hrs.
and $0.08 per KWH
DIMENSIONAL DATA
6.82"
0.75"
A=7/8" KO
B= 3/8" HOLE
A
2.60"
2.50"
48" FOR T8
46.25" FOR T5HO
5.75"
1.5"
5.87"
11.73"
4-LAMP
3"
12"
A
A
0.75"
2.60"
4-LAMP OR 6-LAMP
8.50"
17"
6-LAMP
NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.
Page 2/2 Rev. 12/09/14
© 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
INDUSTRIALS / LHS4
Download