LHS4 Slim Body Linear High Bay / 4 or 6-Lamp T5HO, T8 PROJECT INFORMATION Project Name Type Catalog No. Date HOUSING FINISH 22 gauge riveted steel housing Painted parts are treated with a five stage phosphate bonding process and finished with a high reflectance baked white enamel. End caps are painted after fabrication as standard. BALLASTS FEATURES • • • • Used in high and low bay, aisle and task lighting applications Ideal for mounting heights ranging 8 to 40 feet Rugged 22 gauge riveted full body steel housing 95% specular aluminum reflectors for precise control or finished white reflectors available for wide light distribution • Tool-less ballast access for easy service • V-hangers included for chain hanging Energy efficient, thermally protected, automatic resetting, Class P, high power factor, sound rated A, unless otherwise specified. CEE NEMA Premium compliant. REFLECTOR Choice of 95% specular aluminum or finished white aluminum. ELECTRICAL Standard class “P,” thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard. CERTIFICATION All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. ORDERING INFORMATION LHS 4 MODEL – 4 Four 6 Six LAMP TYPE 32 4', T8: 32, 30, 28, or 25 Watt 54 4', T5HO: 54, 51, or 49 Watt SIZE REFLECTOR 4 4' M4R Aluminum 95% Reflective, Specular Silver (Narrow Beam) GW Gloss White (Wide Beam) ACCESSORIES (ORDER SEPARATELY) LHTG5 LHTG10 LHS432WGK LHS454WGK LHS632WGK LHS654WGK GLH5 GLH10 GLH15 OS1360K U – NO. OF LAMPS IN CROSS SECTION LHS Slim Body Linear High Bay EXAMPLE LHS4-454-M4R-4EPU Y-Fit Toggle Hanger, 5' Adjustable, Pair Y-Fit Toggle Hanger, 10' Adjustable, Pair Wire Guard for 4-Lamp T8 Fixture Wire Guard for 4-Lamp T5HO Fixture Wire Guard for 6-Lamp T8 Fixture Wire Guard for 6-Lamp T5HO Fixture 5', Adjustable Cable Kit 10', Adjustable Cable Kit 15', Adjustable Cable Kit Occupancy/Daylight sensor kit, 120/277/347V, one relay, 360 Lens, snap on drop down adaptor, quick connect wiring* OS2360K Occupancy/Daylight sensor kit, 120/277/347V, two relay, 360 Lens, snap on drop down adaptor, quick connect wiring* *Use programmed start ballast. Not recommended for use with an instant start. For more occupancy/daylight harvesting sensor accessories contact your Columbia Lighting representative. BALLAST T8 4EHL (1) 4-Lamp Electronic T8 High Light Output, Instant Start 3EHL (2) 3-Lamp Electronic T8 High Light Output, Instant Start 4EPHL (1) 4-Lamp Electronic T8 High Light Output, Programmed Start 3EPHL (2) 3-Lamp Electronic T8 High Light Output, Programmed Start T5HO 4EP (1) 4-Lamp Electronic T5HO, Programmed Start 24EP (1) 4-Lamp and (1) 2-Lamp Electronic T5HO, Programmed Start Page 1/2 Rev. 12/09/14 © 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com – VOLTAGE OPTIONS U 120V-277V F3C5 3-Conductor Cord F4C5 4-Conductor Cord C8TL15_ 8' Cord and Twist-Lock™ Plug 15A (Add Voltage: 1=120, 2=277) C8P151 8' Cord and Straight Blade Plug 15A EL Emergency Battery Pack, T8 1100-1200 Lumens, 1 Lamp or T5HO 1150 Lumens, 1 Lamp WG Cage Type Wire Guard LAMPS INSTALLED T8 FO841 FO850 T5HO F5841 F5850 85 CRI, 4100K 85 CRI, 5000K 85 CRI, 4100K 85 CRI, 5000K INDUSTRIALS / LHS4 LHS4 Slim Body Linear High Bay / 4 or 6-Lamp T5HO, T8 PHOTOMETRIC DATA Test 19448 Test Date 04/13/09 Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet LHS4-632-M4R-3EU Linear Fluorescent High Bay Industrial 17"× 48", 6-lamp T8 with specular reflectors (2) GE-332-MAX-H/ ULTRA 1.18 F32T8 2950 Average Luminance Angle Luminaire AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 217 Suspended 0º = 0 90º = 0 0 30 40 45 50 55 60 65 70 75 80 85 0.0 22.5 45.0 67.5 8963 8675 8373 8166 7913 7595 7203 6712 6081 5261 4125 2577 8963 9289 9910 10184 10353 10392 10197 9532 8359 7622 9496 9704 8963 11051 11558 11463 10866 10085 9263 9604 11287 12399 12607 13024 8963 11787 11637 10988 10205 9694 10687 12203 13358 13743 13854 15346 90.0 RC 80 RW 70 50 30 8963 1 98 94 89 11955 2 89 81 74 11471 3 81 70 62 10762 4 74 62 54 10013 5 68 55 47 10050 6 62 49 41 11602 7 58 45 36 12874 8 54 41 33 13754 9 50 37 29 14079 10 47 34 27 14262 16112 RCR = Room Cavity Ratio RCR LUMINAIRE DATA 10 85 68 56 47 40 35 31 27 24 22 70 96 86 78 71 65 60 56 52 49 45 70 50 30 91 87 79 73 69 61 61 53 54 46 49 40 44 36 40 32 37 29 34 27 10 84 67 55 47 40 35 30 27 24 22 50 87 75 66 58 52 47 42 39 35 33 INDOOR CANDELA PLOT 50 30 84 70 60 51 45 40 35 32 29 26 10 81 66 54 46 39 34 30 27 24 22 180 0 0 74 60 50 42 36 31 28 24 22 20 165 150 135 5200 120 2600 105 90 75 2600 60 RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance ZONAL LUMEN SUMMARY 0º = 1.24 90º = 1.57 Length: 4.00 Width: 1.33 Height: 0.00 5200 ENERGY DATA Zone Lumens Lamp Fixt. Total Luminaire Efficiency 0-30 0-40 0-60 0-90 0-180 3822 6549 11875 16051 16244 21.6 37.0 67.1 90.7 91.8 23.5 40.3 73.1 98.8 100.0 Luminaire Efficacy Rating (LER) IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 0 91.8% 15 0.0 88 Non-Compliant $2.73 based on 3000 hrs. and $0.08 per KWH 30 Horiz 0-180 45 45.0 90.0 Test 22716 Test Date 04/13/09 Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet LHS4-454-M4R4EPU Linear Fluorescent High Bay Industrial 12" × 48", 4-lamp T5HO with specular reflectors ICN-4S54-90C-2LS-G 1.00 F54T5HO 4500 Average Luminance Angle Luminaire AVG. LUMINANCE (Candela/Sq. M.) 226 0º = 0 90º = 0 0º = 1.21 90º = 1.05 Length: 4.00 Width: 0.92 Height: 0.00 0 30 40 45 50 55 60 65 70 75 80 85 0.0 22.5 45.0 67.5 90.0 18928 17776 16991 16476 15840 15039 14046 12776 11066 8872 6232 3121 18928 17104 15640 14747 13838 12948 11823 10319 8997 8487 9601 12518 18928 15776 14273 13204 12004 11178 10869 11150 12315 14895 18495 19399 18928 15178 13078 12124 11708 11647 12250 13531 15924 19416 22066 22386 18928 14966 12677 12008 11827 12081 12958 14541 17318 20704 22993 23023 ZONAL LUMEN SUMMARY COEFFICIENTS OF UTILIZATION (%) RCR LUMINAIRE DATA RC RW 1 2 3 4 5 6 7 8 9 10 70 94 86 78 72 66 61 57 53 50 47 80 50 30 90 86 78 72 69 62 61 54 55 47 50 42 45 38 42 34 38 31 35 29 10 82 67 56 48 41 36 32 29 26 24 70 92 83 76 70 65 60 56 52 49 46 70 50 30 88 84 77 71 68 61 60 53 54 47 49 42 45 37 41 34 38 31 35 28 10 81 66 56 47 41 36 32 29 26 24 50 84 74 65 58 52 47 43 40 37 34 50 30 81 69 59 52 46 41 37 33 31 28 INDOOR CANDELA PLOT 10 79 65 55 47 41 36 32 29 26 24 90 0 0 72 60 51 44 38 34 30 27 24 22 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance 75 3300 60 6600 0 15 0.0 30 Horiz 0-180 45.0 45 90.0 ENERGY DATA Zone Lumens Lamp Fixt. Total Luminaire Efficiency 87.3% 0-30 0-40 0-60 0-90 0-180 4687 7372 12087 15715 15715 26.0 41.0 67.1 87.3 87.3 29.8 46.9 76.9 100.0 100.0 Luminaire Efficacy Rating (LER) IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 70 Noncompliant $3.43 based on 3000 hrs. and $0.08 per KWH DIMENSIONAL DATA 6.82" 0.75" A=7/8" KO B= 3/8" HOLE A 2.60" 2.50" 48" FOR T8 46.25" FOR T5HO 5.75" 1.5" 5.87" 11.73" 4-LAMP 3" 12" A A 0.75" 2.60" 4-LAMP OR 6-LAMP 8.50" 17" 6-LAMP NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 2/2 Rev. 12/09/14 © 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com INDUSTRIALS / LHS4