Controls Group 507 E. Michigan Street P.O. Box 423, Milwaukee, WI 53202 Code No. Lit-1920010 SHIBFDïIèS ZKROH ìäëííìí äWKFFã1ò 3HUVRQDOý(QYLURQPHQWV ð PE-FEU Personal Environments Fan and Electronics Unit Circulated Air FDIHXïWLIý Description Features The Circulated Air Fan and Electronics Unit (FEU) mounts under the user’s desk in a Personal Environments system. The Circulated Air FEU conditions ambient air supplied by an HVAC system which is not connected to the Personal Environments system. Desktop diffusers provide the user’s breathing zone with a filtered supply of ambient air. The Circulated Air FEU can operate independently, or can connect to a Johnson Controls Companion system or other building automation system to add monitoring, override capabilities, and precondition to the Personal Environments units. • variable air flow to breathing zone for enhanced user comfort The Circulated Air FEU receives and responds to the following user commands through the Circulated Air User Control Unit (UCU) (ordered separately): fan speed, radiant heat, background noise masking, and task light level adjustment or On/Off control. Selection Chart Code Number • integrated electronics for centralized control • occupancy sensing to save energy when the work station is unoccupied • easy mounting and integration with open-plan furniture systems to reduce office reconfiguration costs • uncompromised user knee space To Order Specify the code number from the following selection charts. The "B" appended to the Personal Environments product code means the product can be ordered in bulk quantities, an option provided to minimize job-site trash for new and retrofit projects. The specific number of items is listed in the product description. Repair Parts Description PE-FEU-DCA111 • high-efficiency filtering to remove sub-micron airborne contaminants Code Number FEU, Circulated Air, North America, 115 VAC, 60 Hz, w/o N2 Description PE-FEU-DCA111B FEU, Circulated Air, North America, 115 VAC, 60 Hz, w/o N2, Bulk 2 PE-FEU-DCA1-700 FEU, Circulated Air, North America, Repair, 115 VAC, 60 Hz, w/o N2 PE-FEU-DCA211 FEU, Circulated Air, North America, 115 VAC, 60 Hz, w/N2 PE-FEU-DCA2-700 PE-FEU-DCA211B FEU, Circulated Air, North America, 115 VAC, 60 Hz, w/N2, Bulk 2 FEU, Circulated Air, North America, Repair, 115 VAC, 60 Hz, w/N2 Specifications PE-FEU Personal Environments Fan and Electronics Unit Circulated Air Specifications (Continued) Power 115 VAC, 60 Hz Requirements Power Cord Current Draw PE-FEU Personal Environments Fan and Electronics Unit Circulated Air 6 ft./1.8m cord with NEMA 3-prong plug 0.10 amperes minimum, 3.5 amperes maximum Fan and Electronics Unit (Continued) Variable Task Light: NEMA receptacle Fan and Electronics Unit Connected On/Off Task Light: Hardware NEMA receptacle Background Noise Adjustable 0 to 45 dB Masking Dimensions 14 x 11.5 x 8.5 in./356 x 292 x 216 mm Weight 12 lb/5.4 kg (Single Circulated Air FEU Only) Color General Electric Dark Gray (GY30006) Radiant Heat Panel: NEMA receptacle Particle Filter 70 weight, Charged fiber (electret) Desktop Air Filter Variable speed, Fan 100 cfm maximum/47.2 L/s maximum Dimensions 2 x 9 x 4.5 in./51 x 229 x 114 mm Weight 2 oz/59g DC Task Light RJ 11 connector 0-10 VDC Connector Agency Listing UL Listed, CSA Certified, BEC/New York City, (EMC directive 89/336/EEC, VCCI listings pending) Ambient Operating Conditions 35 to 100°F/2 to 38°C; 90% RH, non-condensing Ambient Storage Conditions -20 to 150°F/-29 to 66°C; 90% RH, non-condensing User Control Unit RJ 45 connector Network Metasys, N2 Bus Connection Remote Monitor RJ 45 connector and Control The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson © 02/99 Johnson Controls, Inc Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. 1/1 5HYã S H ORJRã SHORJR OHIWýIWãõQ RQHô ULJKWýIWãV WDQ 6HFWúý ýå VH4úý ýë