SB12 Buildings > Lighting Systems > LMS How can the lighting level in an office building be controlled depending on presence and daylight? Requirement You have the task of optimizing the lighting in office buildings from an energy-saving perspective. You want to control the lighting intensity automatically depending on the presence of employees and the natural daylight. You know that you can make additional savings in energy costs of up to 45% by using light management systems (LMS). Areas of application Presence-dependent and daylight-dependent lighting controls within the scope of LMS can be adapted flexibly to the relevant requirements and can be found again in many other lighting applications. • Offices with single workstations and group workstations • Lounges and conference rooms • Hall and entrance areas • The retail trade and business premises • Toilets and sanitary facilities up to 45% energy savings www.siemens.com/ee-applications 2XUDQVZHU DALI MULTIeco control unit with light and presence sensor, OSRAM QTi DALI electronic control gears and OSRAM T5 LUMILUX luminaire 6,7(&2 02'$5,2 265$0 7/80,/8; '(/7$ XQLYHUVDO VZLWFK 265$0'$/,08/7,HFR FRQWUROXQLWZLWKOLJKWDQG SUHVHQFHVHQVRU 265$047L'$/, HOHFWURQLFFRQWUROJHDUV Highlights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ain components required Product Description of functions 1 DELTA universal switch The flush-mounted switch functions as a main switch to turn the lighting on/off. 2 OSRAM MULTI3 LS/PD CI light and presence sensor The LS/PD MULTI3 sensor detects the presence of personnel and measures the intensity of the ambient light. Mounting height is between 2 and 4 m. The use of presence sensors in combination with daylight sensing achieves energy savings of up to 45%. 2 OSRAM MULTIeco control unit Lighting conditions are maintained at an adjustable setpoint by means of daylight-dependent control of the artificial light. If the daylight is a sufficient light source, or if no people are present, the light control unit switches off up to 6 luminaires. Light control and presence detection, as well as automatic switch-on can be activated or deactivated via the DIP switches. The standby power is less than 0.5 W since the control gears are disconnected from the system voltage. Energy savings of up to 45% are possible compared to conventional systems. 3 OSRAM QTi DALI electronic control gears OSRAM QTi DALI control gears are characterized by maximum energy efficiency. Switching and dimming have no effect on the service life of the lamp. 4 OSRAM LUMILUX T5 fluorescent lamp OSRAM T5 HE LUMILUX® lamps (16 mm) are characterized by good luminous flux characteristics. With a preheat ECG, the OSRAM T5 HE achieves an average service life of 20,000 hours and a useful service life of 16,000 hours. LUMILUX T5 lamps offer excellent properties with regard to cost-effectiveness and increased environmental friendliness. Thanks to their high efficiency, they save up to 35% of power costs compared to the OSRAM T8 luminaires. 4 OSRAM LUMILUX SKYWHITE T5 HO fluorescent lamp HO means High Output. This lamp system is characterized above all by its extremely high luminous flux and thus opens up new application areas for the fluorescent lamp such as lighting for high-ceilinged halls. The OSRAM T5 HO 80 W/840 offers a luminous flux of up to 7,000 lm (at 35 °C). OSRAM HO lamps are designed for control gear operation and, like all OSRAM LUMILUX® lamps, they can be used ideally in combination with movement sensors to minimize energy consumption. 5 Product Description of functions SITECO lamps with microprism technology ELDACON®/HDP® The optical ELDACON lighting system, comprising high-precision microprisms, directs the light at the work surface without glare and very evenly. Workstations can be located freely in the available space thanks to the specific light characteristics of lamps with microprism technology. Operating efficiency levels are as high as 105% (direct/indirect beam) and thus make a significant contribution to the energy efficiency of lighting systems in buildings. Lighting Technology for Siemens Projects The 3-level system guarantee from OSRAM: Perfection through quality and innovative technology Electronic control gears from OSRAM are noted for their state-of-the-art circuit design and exclusively highquality components. They achieve their optimum functionality when operating as a system in conjunction with innovative lamps from OSRAM because OSRAM lamps and OSRAM electronic control gears are always optimally matched to one another: As one of the two leading lamp and ECG system providers in the world, we have all the necessary know-how under one roof. Systematic quality assurance measures ensure first-class processing and functionality of our products. Innovative technology and outstanding quality pay off for our customers. OSRAM offers an extensive, threelevel guarantee for ECG and ECG lamp systems from OSRAM! You can find all the details concerning the relevant products and registration, as well as the guarantee conditions and other combinations for OSRAM’s System+ Guarantee (e.g. LED with OPTOTRONIC®) at: www.osram.de/systemgarantie Guarantee level 3 OSRAM System+ Guarantee Guarantee level 2 OSRAM offers a full three-year guarantee on selected electronic control gears. If ECGs and lamps from OSRAM are used together, OSRAM offers a full five-year guarantee on selected electronic control gears. If OSRAM ECGs and lamps/ LED modules from OSRAM are used together (selected series or types), OSRAM offers a full five-year guarantee on the electronic control gears and a guarantee on the LED modules, LUMILUX® fluorescent lamps, HCI®/HQI® high-pressure discharge lamps and IRC-halogen low-voltage lamps. The guarantee starts when the relevant luminaire with the appropriate OSRAM ECG is first put into operation. For this guarantee, no registration is required. For the System Guarantee, the lighting system must be registered with OSRAM on the Internet at www.osram.de/systemgarantie For the System+ Guarantee, the lighting system must be registered with OSRAM on the Internet at www.osram.de/systemgarantie Guarantee level 1 OSRAM Guarantee OSRAM System Guarantee Further information For details on individual products: www.siemens.com/delta www.osram.com/Professionals For technical assistance regarding the use of products: www.siemens.com/lowvoltage/technical-support Subject to change without prior notice 09/11 Order No. E20001-A1350-M102-X-7600 Printed in Germany © Siemens AG 2011 Siemens AG Industry Sector P.O. Box 48 48 90026 NÜRNBERG GERMANY www.siemens.com/ee-applications The information provided in this brochure contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. OSRAM GmbH Department KSC Phone: +49 (0)89 62 13 6000 Hellabrunner Str. 1 D-81543 München GERMANY www.osram.com