Certification Report Template

advertisement
Certificate of Compliance
Certificate:
2719243
Master Contract: 153857
Project:
70021723
Date Issued: March 05, 2015
Issued to:
Vega Grieshaber KG
Am Hohenstein 113
Schiltach, 77761
GERMANY
Attention: Nick Ilchovski
The products listed below are eligible to bear the CSA Mark shown
with adjacent indicators 'C' and 'US' for Canada and US or with adjacent
indicator 'US' for US only or without either indicator for Canada only.
Issued by:
Hossein Saleh
Hossein Saleh
PRODUCTS
CLASS - C225802 - PROCESS CONTROL EQUIPMENT-For Hazardous LocationsCLASS - C225882 - PROCESS CONTROL EQUIPMENT-For Hazardous Locations - Certified to US Standards
Class I Division 2, Groups A, B, C, and D; Class II Division 2, Groups F and G; Class III
VEGAPULS PSWL61 radar sensors for level measurement. Temperature code T6-T1.
The following ratings are applicable to all VEGAPULS PSWL61 models when used in Class I Division 2:
HART Models: 4-20 mA, 9.6-36 Vdc
PROFIBUS / Fieldbus Models: 10 mA +/- 5 mA, 12-32 Vdc
Permissible ambient temperatures in dependence on temperature code:
T Code
Permissible ambient temperature on the sensor and electronics
T6, T5, T4, T3, T2, T1
- 20°C... + 50°C
Note: Radar Sensor installation shall take into account the effects of process temperature on ambient temperature
of the radar sensor and the electronics assembly to ensure that the specified temperature ranges in the above table
shall not be exceeded.
DQD 507 Rev. 2012-05-22
Page 1
49580-EN-150323
Certificate:
Project:
2719243
70021723
Master Contract: 153857
Date Issued: March 05, 2015
VEGAPULS PSWL61(a).KXbcdefg
Where:
a=
Optional electable parameter for internal information, options not affecting safety, one digit alphanumeric
variable referring to non-electrical properties
b=
Version/material/Process temperature: B
c=
Process Connection/Material: Two digit alphanumeric variable for connections, which represents a LA,
NPT, G, TRI- CLAMP, DN or ASME industry type process connection/flange with pressure ratings.
d=
Electronics: F, H or P
e=
Housing/Protection: K
f=
Cable/Material/Temperature: A or T
g=
Additional equipment: X
CLASS - C225804 - PROCESS CONTROL EQUIPMENT-Intrinsically Safe, Entity - For Hazardous LocationsCLASS - C225884 - PROCESS CONTROL EQUIPMENT - Intrinsically Safe, Entity-- For Hazardous Locations
- Certified to US Standards
Class I Division 1, Groups A, B, C, and D; Class II Division 1, Groups E, F, and G; Class III
Ex ia IIC T6-T1 Ga
Class I, Zone 0, 0/1, 1, AEx ia IIC T6-T1 Ga
VEGAPULS PSWL61 radar sensors for level measurement. Temperature code T6-T1.
Intrinsically safe when installed per drawing GE49579 and used with the entity parameters listed below.
x
x
x
Hart - Electronics Option H: Vmax = 30 V, Imax = 131 mA, Pi = 983 mW, Ci = 0 uF, Li = 5 μH
ProfiBus/Fieldbus - Electronics Option P/F: Vmax = 24 V, Imax = 250 mA, Pi = 1.2 W, Ci = 0 uF, Li = 5 μH
FISCO Field Device parameters: Vmax = 17.5V, Imax = 500 mA, Pi = 5.5 W, Ci = 0 uF, Li = 5 μH
VEGAPULS PSWL61(a).KFbcdefg
Where:
a=
Optional electable parameter for internal information, options not affecting safety, one digit alphanumeric
variable referring to non-electrical properties
b=
Version/material/Process temperature: B
c=
Process Connection/Material: Two digit alphanumeric variable for connections, which represents a LA,
NPT, G, TRI- CLAMP, DN or ASME industry type process connection/flange with pressure ratings.
d=
Electronics: F, H or P
e=
Housing/Protection: K
f=
Cable/Material/Temperature: A or T
g=
Additional equipment: X
DQD 507 Rev. 2012-05-22
Page 2
49580-EN-150323
Certificate:
Project:
2719243
70021723
Master Contract: 153857
Date Issued: March 05, 2015
Permissible ambient temperatures in dependence on temperature code:
Note: Radar Sensor installation shall take into account the effects of process temperature on ambient temperature
of the radar sensor and the electronics assembly to ensure that the specified temperature ranges in the tables below
shall not be exceeded.
Radar sensor VEGAPULS PSWL61.KF***H***
Installation in Zone 0
Temperature code
T5
T4, T3, T2, T1
Ambient temperature on the sensor
-20°C … + 46°C
-20°C … + 60°C
Ambient temperature on the electronics
-20°C … + 46°C
-20°C … + 60°C
Installation in the separating wall between Zone 0 and Zone 1 (Division 1 installations)
Temperature code
Ambient temperature on the sensor
Ambient temperature on the electronics
T6
-20°C … + 60°C
-40°C … + 50°C
T5
-20°C … + 60°C
-40°C … + 65°C
T4, T3, T2, T1
-20°C … + 60°C
-40°C … + 80°C
Installation in Zone 1
Temperature code
T6
T5
T4, T3, T2, T1
Ambient temperature on the sensor
-40°C … + 80°C
-40°C … + 80°C
-40°C … + 80°C
Ambient temperature on the electronics
-40°C … + 50°C
-40°C … + 65°C
-40°C … + 80°C
Radar sensor VEGAPULS PSWL61.KF***P/F***
Installation in Zone 0
Temperature code
T5
T4, T3, T2, T1
Ambient temperature on the sensor
-20°C … + 42°C
-20°C … + 60°C
Ambient temperature on the electronics
-20°C … + 42°C
-20°C … + 60°C
Installation in the separating wall between Zone 0 and Zone 1 (Division 1 installations)
Temperature code
Ambient temperature on the sensor
Ambient temperature on the electronics
T6
-20°C … + 60°C
-40°C … + 46°C
T5
-20°C … + 60°C
-40°C … + 61°C
T4, T3, T2, T1
-20°C … + 60°C
-40°C … + 80°C
Installation in Zone 1
Temperature code
T6
T5
T4, T3, T2, T1
DQD 507 Rev. 2012-05-22
Ambient temperature on the sensor
-40°C … + 80°C
-40°C … + 80°C
-40°C … + 80°C
Ambient temperature on the electronics
-40°C … + 46°C
-40°C … + 61°C
-40°C … + 80°C
Page 3
49580-EN-150323
Certificate:
Project:
2719243
70021723
Master Contract: 153857
Date Issued: March 05, 2015
APPLICABLE REQUIREMENTS
CSA Std. C22.2 No. 0-10
CAN/CSA-C22.2 No. 61010-1-12
-
CSA Std. C22.2 No. 213-M1987 (R2004) C22.2 No 25-1966 (R 2004)
-
C22.2 No 94-M91 (R 2006)
C22.2 No 157-92 (R 2006)
-
CAN/CSA Std. C22.2 No. 60079-0:11
-
CAN/CSA Std. C22.2 No. 60079-11:11 UL Std. No. 61010-1 (3rd Edition)
-
UL Std. No. 913 (4th Ed.)
-
UL Std. No. 50 (Edition 10)
UL Std. No. 1203, Ed 4 (2006)
-
UL Std. 60079-0 (5th Edition)
-
th
UL Std. 60079-11 (5 Edition)
-
ANSI/ISA 12.12.01
-
DQD 507 Rev. 2012-05-22
General Requirements – Canadian Electrical Code, Part II
Safety Requirements for Electrical Equipment for Measurement,
Control, and Laboratory Use, Part 1: General Requirements
Non-Incendive Electrical Equipment for Use in Class I, Division 2
Hazardous Locations
Enclosures for Use in Class II Groups E, F and G Hazardous
Locations
Special Purpose Enclosures
Intrinsically Safe and Non-Incendive Equipment for Use in
Hazardous Locations
Electrical apparatus for explosive gas atmospheres - Part 0:
General requirements
Electrical apparatus for explosive gas atmospheres - Part 11:
Intrinsic safety "i"
Safety Requirements for Electrical Equipment for Measurement,
Control, and Laboratory Use - Part 1: General Requirements
Intrinsically Safe and Associated Apparatus For Use In
Class I, II, and III, Division 1, Hazardous (Classified)
Locations
Enclosures for Electrical Equipment
Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for
Use in Hazardous (Classified) Locations
Explosive atmospheres – Part 0: Equipment – General
requirements
Explosive Atmospheres – Part 11: Equipment Protection by
Intrinsic Safety “i”
Nonincendive Electrical Equipment for Use in Class I and II,
Division 2 and Class III, Division 1 and 2 Hazardous (Classified)
Locations
Page 4
49580-EN-150323
Supplement to Certificate of Compliance
Certificate:
2719243
Master Contract: 153857
The products listed, including the latest revision described below,
are eligible to be marked in accordance with the referenced Certificate.
Product Certification History
Project
Date
Description
70021723
Mar 5 2015
Update VEGA CSA Certificate and Report 2719243 to update temperature
tables for Div 2 and IS versions of VEGAPULS PSWL61 series with no
testing required.
70016053
Jan 20 2015
Update VEGA CSA Certificate 2719243 to include model nomenclature
2719243
Nov 10 2014
cCSAus certification of VEGAPULS WL 61 level detetor for Hazardous