Certificate of Compliance Certificate: 2719243 Master Contract: 153857 Project: 70021723 Date Issued: March 05, 2015 Issued to: Vega Grieshaber KG Am Hohenstein 113 Schiltach, 77761 GERMANY Attention: Nick Ilchovski The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Hossein Saleh Hossein Saleh PRODUCTS CLASS - C225802 - PROCESS CONTROL EQUIPMENT-For Hazardous LocationsCLASS - C225882 - PROCESS CONTROL EQUIPMENT-For Hazardous Locations - Certified to US Standards Class I Division 2, Groups A, B, C, and D; Class II Division 2, Groups F and G; Class III VEGAPULS PSWL61 radar sensors for level measurement. Temperature code T6-T1. The following ratings are applicable to all VEGAPULS PSWL61 models when used in Class I Division 2: HART Models: 4-20 mA, 9.6-36 Vdc PROFIBUS / Fieldbus Models: 10 mA +/- 5 mA, 12-32 Vdc Permissible ambient temperatures in dependence on temperature code: T Code Permissible ambient temperature on the sensor and electronics T6, T5, T4, T3, T2, T1 - 20°C... + 50°C Note: Radar Sensor installation shall take into account the effects of process temperature on ambient temperature of the radar sensor and the electronics assembly to ensure that the specified temperature ranges in the above table shall not be exceeded. DQD 507 Rev. 2012-05-22 Page 1 49580-EN-150323 Certificate: Project: 2719243 70021723 Master Contract: 153857 Date Issued: March 05, 2015 VEGAPULS PSWL61(a).KXbcdefg Where: a= Optional electable parameter for internal information, options not affecting safety, one digit alphanumeric variable referring to non-electrical properties b= Version/material/Process temperature: B c= Process Connection/Material: Two digit alphanumeric variable for connections, which represents a LA, NPT, G, TRI- CLAMP, DN or ASME industry type process connection/flange with pressure ratings. d= Electronics: F, H or P e= Housing/Protection: K f= Cable/Material/Temperature: A or T g= Additional equipment: X CLASS - C225804 - PROCESS CONTROL EQUIPMENT-Intrinsically Safe, Entity - For Hazardous LocationsCLASS - C225884 - PROCESS CONTROL EQUIPMENT - Intrinsically Safe, Entity-- For Hazardous Locations - Certified to US Standards Class I Division 1, Groups A, B, C, and D; Class II Division 1, Groups E, F, and G; Class III Ex ia IIC T6-T1 Ga Class I, Zone 0, 0/1, 1, AEx ia IIC T6-T1 Ga VEGAPULS PSWL61 radar sensors for level measurement. Temperature code T6-T1. Intrinsically safe when installed per drawing GE49579 and used with the entity parameters listed below. x x x Hart - Electronics Option H: Vmax = 30 V, Imax = 131 mA, Pi = 983 mW, Ci = 0 uF, Li = 5 μH ProfiBus/Fieldbus - Electronics Option P/F: Vmax = 24 V, Imax = 250 mA, Pi = 1.2 W, Ci = 0 uF, Li = 5 μH FISCO Field Device parameters: Vmax = 17.5V, Imax = 500 mA, Pi = 5.5 W, Ci = 0 uF, Li = 5 μH VEGAPULS PSWL61(a).KFbcdefg Where: a= Optional electable parameter for internal information, options not affecting safety, one digit alphanumeric variable referring to non-electrical properties b= Version/material/Process temperature: B c= Process Connection/Material: Two digit alphanumeric variable for connections, which represents a LA, NPT, G, TRI- CLAMP, DN or ASME industry type process connection/flange with pressure ratings. d= Electronics: F, H or P e= Housing/Protection: K f= Cable/Material/Temperature: A or T g= Additional equipment: X DQD 507 Rev. 2012-05-22 Page 2 49580-EN-150323 Certificate: Project: 2719243 70021723 Master Contract: 153857 Date Issued: March 05, 2015 Permissible ambient temperatures in dependence on temperature code: Note: Radar Sensor installation shall take into account the effects of process temperature on ambient temperature of the radar sensor and the electronics assembly to ensure that the specified temperature ranges in the tables below shall not be exceeded. Radar sensor VEGAPULS PSWL61.KF***H*** Installation in Zone 0 Temperature code T5 T4, T3, T2, T1 Ambient temperature on the sensor -20°C … + 46°C -20°C … + 60°C Ambient temperature on the electronics -20°C … + 46°C -20°C … + 60°C Installation in the separating wall between Zone 0 and Zone 1 (Division 1 installations) Temperature code Ambient temperature on the sensor Ambient temperature on the electronics T6 -20°C … + 60°C -40°C … + 50°C T5 -20°C … + 60°C -40°C … + 65°C T4, T3, T2, T1 -20°C … + 60°C -40°C … + 80°C Installation in Zone 1 Temperature code T6 T5 T4, T3, T2, T1 Ambient temperature on the sensor -40°C … + 80°C -40°C … + 80°C -40°C … + 80°C Ambient temperature on the electronics -40°C … + 50°C -40°C … + 65°C -40°C … + 80°C Radar sensor VEGAPULS PSWL61.KF***P/F*** Installation in Zone 0 Temperature code T5 T4, T3, T2, T1 Ambient temperature on the sensor -20°C … + 42°C -20°C … + 60°C Ambient temperature on the electronics -20°C … + 42°C -20°C … + 60°C Installation in the separating wall between Zone 0 and Zone 1 (Division 1 installations) Temperature code Ambient temperature on the sensor Ambient temperature on the electronics T6 -20°C … + 60°C -40°C … + 46°C T5 -20°C … + 60°C -40°C … + 61°C T4, T3, T2, T1 -20°C … + 60°C -40°C … + 80°C Installation in Zone 1 Temperature code T6 T5 T4, T3, T2, T1 DQD 507 Rev. 2012-05-22 Ambient temperature on the sensor -40°C … + 80°C -40°C … + 80°C -40°C … + 80°C Ambient temperature on the electronics -40°C … + 46°C -40°C … + 61°C -40°C … + 80°C Page 3 49580-EN-150323 Certificate: Project: 2719243 70021723 Master Contract: 153857 Date Issued: March 05, 2015 APPLICABLE REQUIREMENTS CSA Std. C22.2 No. 0-10 CAN/CSA-C22.2 No. 61010-1-12 - CSA Std. C22.2 No. 213-M1987 (R2004) C22.2 No 25-1966 (R 2004) - C22.2 No 94-M91 (R 2006) C22.2 No 157-92 (R 2006) - CAN/CSA Std. C22.2 No. 60079-0:11 - CAN/CSA Std. C22.2 No. 60079-11:11 UL Std. No. 61010-1 (3rd Edition) - UL Std. No. 913 (4th Ed.) - UL Std. No. 50 (Edition 10) UL Std. No. 1203, Ed 4 (2006) - UL Std. 60079-0 (5th Edition) - th UL Std. 60079-11 (5 Edition) - ANSI/ISA 12.12.01 - DQD 507 Rev. 2012-05-22 General Requirements – Canadian Electrical Code, Part II Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use, Part 1: General Requirements Non-Incendive Electrical Equipment for Use in Class I, Division 2 Hazardous Locations Enclosures for Use in Class II Groups E, F and G Hazardous Locations Special Purpose Enclosures Intrinsically Safe and Non-Incendive Equipment for Use in Hazardous Locations Electrical apparatus for explosive gas atmospheres - Part 0: General requirements Electrical apparatus for explosive gas atmospheres - Part 11: Intrinsic safety "i" Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 1: General Requirements Intrinsically Safe and Associated Apparatus For Use In Class I, II, and III, Division 1, Hazardous (Classified) Locations Enclosures for Electrical Equipment Explosion-Proof and Dust-Ignition-Proof Electrical Equipment for Use in Hazardous (Classified) Locations Explosive atmospheres – Part 0: Equipment – General requirements Explosive Atmospheres – Part 11: Equipment Protection by Intrinsic Safety “i” Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazardous (Classified) Locations Page 4 49580-EN-150323 Supplement to Certificate of Compliance Certificate: 2719243 Master Contract: 153857 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Product Certification History Project Date Description 70021723 Mar 5 2015 Update VEGA CSA Certificate and Report 2719243 to update temperature tables for Div 2 and IS versions of VEGAPULS PSWL61 series with no testing required. 70016053 Jan 20 2015 Update VEGA CSA Certificate 2719243 to include model nomenclature 2719243 Nov 10 2014 cCSAus certification of VEGAPULS WL 61 level detetor for Hazardous Lcoations DQD 507 Rev. 2012-05-22 Page 1 49580-EN-150323 49580-EN-150323 49580-EN-150323 49580-EN-150323