HAL Center Sensor Aisle Lighter, Narrow Product Information Project Name Type Catalog Number Date SPECIFICATIONS Features • Excellent vertical illumination for aisle lighting. • Energy-efficient fluorescent aisle lighter available with integrated sensor to increase energy savings in infrequently occupied, high piled storage aisles. • Four foot configurations available with extended body end mount sensor. • Eight foot configurations available with center mounted sensor. • Low profile allows mounting closer to the ceiling than standard Metal Halide systems reducing potential forklift damage. • A width of only 6.28"; clearance for fire sprinklers is not an issue. • Available up to 2 lamp cross section. • Optional wireguard or lens. • Fluorescent technology is proven long life. • Excellent lumen maintenance (95% versus ~65% for typical metal halide). • Superior color rendering (82 CRI, versus 65-70 for metal halide). • Made In USA. Meets ARRA & Buy American requirements. Construction • • • • • • • Heavy duty aluminum ventilated body and endplates dissipate heat Reflector improves uniformity; see ordering information below for optic availability Standard mounting holes and v-hangers included Additional Mounting hardware available Optional integrated sensor Optional lens or wireguard Weight: 1x4-6lbs. 1x8-13lbs. Certifications • UL 1598 listed for Canada and U.S. • Luminaires bear appropriate listing labels. • Emergency-equipped fixtures labeled UL 924. Application Electrical • • • • • • • • • Open fixtures suitable up to 50°C/122°F • Suitable for use with most wired or wireless lighting control systems • Suitable for dry & damp locations: • Aisles • Industrial • Assembly • Factory • Manufacturing • Storage • Warehouses • Low-Bay • Commercial Input Voltage Range: 100-277 VAC Nom. (90-305 V Min/Max) Lamp frequency: > 42 kHz Power Factor: >0.9% @ full load, 100V through 277V Harmonic Distortion: THD < 20% @ full load Protection: Over-Voltage, Over-Current & Short Circuit with self-recovery Compliant to FCC 47CFR Part 18 Non-consumer Class A Sound Rating Optional emergency battery backup Optional step down transformer, drops 480 VAC to 277 VAC ORDERING INFORMATION – MODEL HAL Aisle Lighter, Narrow SIZE 1x4 1x4 Nominal 1x8 1x8 Nominal LAMP QTY 1L 1 Lamp 2L 2 Lamp 4L 4 Lamp – – – EXAMPLE HAL-1X4-2L-T5HO-UL1-MN-PS-ST-EA-NO – – – – LAMP TYPE BALLAST FACTOR2 BALLAST GRADE T5HO T5HO T8 T8 LP Low Power ST Standard BALLAST VOLTAGE1 UL x Universal 120-277 VAC UHx 347-480 VAC (.75-.78) MP Medium Power (.85-.88) MN Neutral Power (.97-1.04) HP High Power (1.15-1.20) BALLAST STARTING3 Grade UE Ultra Efficient T8 REFLECTOR MATERIAL EA Enhanced Aluminum 95% MM Micro Matte 91-93% WA White Aluminum Reflector 90-91% IS Instant Start ISD Instant Start Step Dimming PS Programmed Start FOOTNOTES 1. Numeral indicates number of ballasts per fixture. 2. "MN" Ballast factor not for use with T8/ISD or T8/PS. 3. When using UL2, identify number of lamps powered by each ballast before starting method. Largest number first. Ex: 22PS = 4LT5HO. 4. Contact factory for additional cord & mounting options. 5. Numeral indicates number of lamps controlled, HBA is std. For Wattstopper, specify -WS after sensor option. OTHER CA WG WW LRS Clear Acrylic – – – OPTICS – – OCC SENSOR5 MO Medium Optics (Std.) NO Narrow Optics SHx Standard 360° WO Wide Optics RHx Rectangular Aisle (Focused on Aisle Center) (Focused on Aisle Walls) CORD PLUG4 C6 C6/ L715 C6/515 6' Cord, No Plug 6' Cord & Plug (L7-15P) View High-Bay Sensor View High-Bay Sensor SLx Standard 360° View Low-Bay Sensor RLx Rectangular Aisle View Low-Bay Sensor OTHER LF Factory Lamps (Lamp spec elsewhere) TRS Step Down Transformer (Takes 480 to 277 VAC) EB Emergency Battery Backup 1PK Individually Boxed Fixture 6' Cord & Plug (515P) PQC15 15' Cord/Quick Connect Zinc Wireguard White Wireguard Lamp Retainer Strap HB 2 Point Mount Dedicated Hanging Brackets Page 1/4 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com HAL Center Sensor Aisle Lighter, Narrow PHOTOMETRIC DATA PHOTOMETRIC DATA: HAL-1X4-2L-T5HO-UL1-MN-PS-ST-EA-NO LUMINAIRE DATA INDOOR CANDELA PLOT 90 Luminaire RCR 80 70 109 100 91 83 76 70 65 60 56 52 49 50 109 95 83 74 65 58 52 48 43 40 36 10 109 88 72 60 51 44 39 34 30 27 24 70 106 97 88 81 74 68 63 58 54 51 47 50 106 93 82 72 64 57 52 47 43 39 36 29 48 82 100 2813 60 AVG. LUMINANCE (Candela/Sq. M.) 4220 50 5626 0 10 20 50 30 106 90 76 65 57 50 44 39 35 32 29 %Fixt 26 44 75 91 70 70 30 109 92 77 66 57 50 44 40 36 32 29 %Lamp 2632 4384 7467 9141 80 30 40 COEFFICIENTS OF UTILIZATION (%) RC Lumens 0-30 0-40 0-60 0-90 1407 0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _ RW 0 1 2 3 4 5 6 7 8 9 10 Zone 10 106 87 71 60 51 44 38 34 30 27 24 50 102 89 79 69 62 55 50 45 41 38 35 30 102 87 74 64 55 49 43 39 35 31 29 0 10 102 84 70 59 50 43 38 34 30 27 24 0 91 77 65 55 47 41 35 31 28 25 22 Average Luminance Angle HAL-1X4-2L-T5HO-UL1-MN-PS-ST-EA-NO 1x4 Aisle Lighter Narrow Ballast ICN-2S54 Ballast Factor 1.00 Lamp FP54 Fixture Lumens 9141 Watts 117 Fixture Efficiency 91% Mounting Suspended Shielding Angle 0° = 90 90° = 90 Spacing Criterion 0° = 1.26 90° = 0.74 Luminous Opening Length: 3.86 in feet Width: 0.47 Height: 0.00 ZONAL LUMEN SUMMARY 0 5 15 25 35 45 55 65 75 85 0.0 22.5 45.0 67.5 90 5368 5626 5389 4904 4231 3367 2465 1486 500 23 5368 5623 5253 4503 3579 2034 1418 868 258 27 5368 5393 4739 3450 2228 1877 1212 542 276 38 5368 5094 4155 2607 2320 1661 860 532 269 44 5368 4982 3925 2467 2212 1549 780 526 245 44 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance MOUNTING OPTIONS - SUSPENDED DOTTIE SLOT WITH V-HANGER GRIPPLE LOOP Included Order Separately HB 2-POINT HANGING BRACKETS V-HANGER Optional - Factory Installed Included DOTTIE SLOT WITH V-HANGER GRIPPLE LOOP Order Separately TOP BOX FOR POWER SUPPLY Included Optional 4" OR GRIPPLE LOOP Order Separately 4" 2" Page 2/4 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com HAL Center Sensor Aisle Lighter, Narrow FIXTURE DIMENSIONS 1L & 2L T8 CROSS SECTION 6.280" 6.280" 3.175" 3.175" w/Sensor w/Sensor 1L & 2L T5HO CROSS SECTION 6.280" 6.280" 3.175" 3.175" w/Sensor w/Sensor HAL-1X4 HAL-1X8 T8 = 48" (+ 6" With Integrated End Sensor = 54") T5HO = 46" (+ 6" With Integrated End Sensor = 52") T8 = 96" (+ 6" With Integrated End Sensor = 102") T5HO = 92" (+ 6" With Integrated End Sensor = 98") 98.000" 6.280" 6" Mounting Location 12" K.O. 102.000" 6.280" 14.25" K.O. 6" Mounting Location *Drawings N.T.S. Page 3/4 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com HAL Center Sensor Aisle Lighter, Narrow EXISTING VS. PROPOSED HIGH-BAY SYSTEM Existing High-Bay System MH250 MH320PS MH400 HPS400 Proposed High-Bay System Lamp Quantity & Type 1 1 1 1 Std. MH250 PS MH320 Std. MH400 Std. HPS400 Lamp Quantity & Type Initial Lamp Lumens Lumen Maintenance EOL (1) Lumens All Lamps Total Fixture Lumens 20,500 31,700 38,000 50,000 58% 62% 58% 70% 11,890 19,654 22,040 35,000 11,890 19,654 22,040 35,000 Initial Lamp Lumens Lumen Maintenance EOL (1) Lumens All Lamps Total Fixture Lumens EOL (1) Ballast Fixture Lumens Per Factor Efficiency Fixture 1.00 1.00 1.00 1.00 0.75 0.75 0.75 0.75 8,198 14,741 16,530 26,250 EOL (1) Ballast Fixture Lumens Per Factor Efficiency Fixture S/P (2) Ratio Net (3) EOL Lumens Fixture Input Watts 1.49 1.49 1.49 0.62 12,171 20,119 22,561 18,080 295 368 458 464 S/P (2) Ratio Net (3) EOL Lumens Fixture Input Watts 2L-T5HO 4L-T5HO 2L-T8 Plus 2 4 2 FP54T5HO FP54T5HO F32T8/841 5,000 5,000 2,950 93% 93% 90% 4,650 4,650 2,655 9,300 18,600 5,310 1.00 1.00 1.15 0.92 0.92 0.90 8,556 17,112 5,496 1.62 1.62 1.62 12,465 24,930 8,007 117 234 73 4L-T8 Plus 4 F32T8/841 2,950 90% 2,655 10,620 1.14 0.90 10,896 1.62 15,874 147 (1) EOL = End of life (2) S/P Ratio = Scotopic to Photopic Lumens (3) Net EOL Lumens = EOL Lumens Per Fixture x (S/P).78 [.78 exponent] *Lamp/ballast system values shown are a general reference intended to supply a quick comparison of several common lamp/ballast systems, the associated energy consumption, and net lumen output. *Values shown are based on normal operating temperatures (25°C T8 and 35°C T5) and at 277 volts. *Fixture efficiency percentages are generally representative of each system type, actual values will vary. *There are many operating variables that affect system output, in addition to rating variances from brand to brand. *All T8 electronic ballast values shown are based on Ultra Efficient (aka 3rd Generation) T8 ballasts. *All T5 and T8 lamp values shown are for basic grade lamps. Extended life and higher lumen lamp types are available. *In addition to those shown, there are a wide variety of systems to choose from, each with distinct features and cost points. *Please consult the lamp/ballast manufacturer's catalogs for the detailed information required to model your system. Page 4/4 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com