HP9826/9836 HP Pascal Kermit Mike Gallaher, Rutgers University December 1984 WARNING: This document isn't finished yet! Don't be surprised if you can't find a section cited elsewhere in the document... This Kermit is intended to run on the HP9826/9836 workstations under the HP Pascal Language System. It depends on various HP Pascal language extensions, such as modules and string data types. The current implementation is minimal - it will only transfer text files, only one file at a time. It can talk to a server, but it is not smart (i.e., no timeouts). The user interface is display oriented; for example, this Kermit maintains a continuous status display during file transfers. I plan to be adding a lot to this implementation quite soon, to improve the user command interface, error handling, add login packets, and maybe binary transfers. This file tells the following - the history of this implementation what (mis)features this Kermit has plans for future development how to get the Kermit sources onto your HP machine how to compile and link HP Kermit how to use this Kermit program structure and internals This implementation is maintained by US mail: Mike Gallaher Rutgers University Box 879 Piscataway, NJ 08876 Arpanet (preferred to US mail): Gallaher@Rutgers.arpa History ------This implementation of Kermit for the HP9826/9836 workstations is based on the RT-11 OMSI Pascal Kermit that was developed by Philip Murton, University of Toronto Computing Services, and Michael K. Weisberg, Mount Sinai Hospital. The protocol support routines are taken mostly intact from the RT-11 version. The main modifications are in the program structure - it has been split into modules - in the IO mechanisms, and in the user interface. Features of this Kermit ----------------------This implementation is, at the moment, a minimally functional but working Kermit. A lot of extensions are planned, however. The important features (marked by +) and misfeatures (marked by -) of the current version are + + + errors not handled gracefully only transfers one file at a time does not handle wild cards only transfers text files continuous status display during file transfers can talk to a server does not handle timeouts only acts as local Kermit reasonably friendly command interface, loosely modeled after the TOPS-20 COMND facility. The user interface is based on a primitive window display facility. There is a window for the status display, one for command echoing, one for error messages, and one for help messages. The command input interface is loosely based on the TOPS-20 COMND parsing facility, which features keyword recognition, keyword and filename completion, and dynamically available help messages and guide words. The Kermit command interface is much more modest - it allows keyword abbreviation, but at the moment that's about all. Soon to be added are dynamic help messages and keyword completion. Future development -----------------The following extensions are planned, in my own order of priority: o Fix the error handling mechanism, which is the most serious deficiency. o Add the ability to send login packets, to work, for example, in conjunction with a server on a mainframe for file access checking. o Implement multiple file transfers via single command. o Fix the command interface so it really works and add help messages. o Implement wild card file transmission. o Implement binary file transfers. o Add timeout capability. How to get the HP Kermit sources onto your HP machine ----------------------------------------------------This section tells how to get the Kermit sources onto your HP system, where they will be compiled and linked (described in the next section). I'll outline the procedure first, then describe it in detail. First, you need to get the source files from the Kermit distribution tape, or via network from the Kermit repository at Columbia. You will load these files onto some convenient system, which I will hereafter call the host. Any system that can run Kermit, and onto which you can somehow get the HP-Kermit source files, will do as a host. You must rename the files (see below) and then use a primitive downloading program to download a baby Kermit to the HP system. Then you use the baby Kermit to download the full-fledged Kermit source files. The HP Kermit source files, like those of a few other implementations, have different names on the distribution tape than they must have on the system on which they will be compiled and run. This is done to make the names agreeable to as many systems as possible (e.g., making the name less than 9 characters so a VAX/VMS system will like it). Once the files are on whatever host system you are using (having been FTPed or copied from the distribution tape), you must rename them according to the table below before moving them to the target HP system. This is VERY important, because if you don't at least change the extension to .TEXT, the HP file system will store them in the wrong format, and the editor, compiler, etc. will refuse to have anything to do with them. Kermit Distrution Name HP9KER.PAS HP9KER.PAS HP9KER.PAS HP9KER.DOC HP9KER.PAS HP9KER.PAS HP9KER.PAS Modules (reproduced below) (reproduced below) HP Pascal System Name Description KRMCMD.TEXT KRMGUTS.TEXT KRMIO.TEXT KRMDOC.TEXT KRMMAIN.TEXT KRMRPT.TEXT KRMWNDW.TEXT Command Parser Protocol Module I/O Module Documentation Main Program Modules Error Reporting Modules Window Management KRMCOMP.TEXT KRMLINK.TEXT Compilation Procedure Linking Procedure Compiling and Linking this Kermit --------------------------------The program source resides in six files, each of which contains one or more modules (these are more fully documented in the section on program structure): KRMMAIN.TEXT KRMCMD.TEXT The main program Generalized input parsing package, loosely based on TOPS-20 COMND facility. KRMGUTS.TEXT Kermit protocol support routines KRMIO.TEXT Byte-oriented string manipulation and IO facilities, terminal emulation package KRMRPT.TEXT Error and status reporting routines KRMWINDOW.TEXT Generalized, rudimentary window display manager package Each of these files must be compiled, in the order dictated by which modules depend on which other modules, and then linked together to form the executable KERMIT.CODE file. There are two command stream files provided to do this: KRMCOMP.TEXT Compiles all the modules in the right order, and then invokes KRMLINK.TEXT to build the .CODE file. Here it is: CKRMWNDW N CKRMRPT N CKRMCMD N CKRMIO N CKRMGUTS N CKRMMAIN N SKRMLINK KRMLINK.TEXT Links the modules together into KERMIT.CODE. Here it is: LOKERMIT IKRMWNDW AIKRMRPT AIKRMCMD AIKRMIO AIKRMGUTS AIKRMMAIN ALKQXKERMIT All the source files and stream files are expected to be found in the current default directory. If they are, then invoking the file KRMCOMP.TEXT (using the S command at the top level) will compile and link all the modules, producing a ready-to-run KERMIT.CODE in the default directory. If you have modified one of the modules, but haven't changed the interface text, you need only compile that module alone, then invoke KRMLINK.TEXT. If you have modified the interface text, say, by adding a new exported routine, then you may have to recompile any modules that depend on objects exported from that module. How to use this Kermit ---------------------When Kermit is started, it clears the screen and prints the command prompt HP-Kermit> and waits for you to enter a command. The valid commands are: EXIT RECEIVE SEND SET SHOW TN Return to top level Request the remote server to send a given file Send a given file to the remote server Set flags and operating parameters Show current flag and parameter settings Open a terminal connection to the remote host The command interface is modeled after the TOPS-20 COMND facility. User input is echoed in the command window as it is typed. Typing Backspace (BS) or Delete (CLR LN on the HP) will cause the last typed character, if any, to be deleted. CTRL-U will cause the entire line to be aborted. At present, Kermit only parses one token at a time - if you type "SEND ", Kermit has already parsed the SEND keyword, and is now expecting a filename; you can't BS past the space. This is an annoyance that will go away in future releases... For now, the only way you can change your mind at this point is to type CTRL-U to abort the entire line, and start over. Typing a question mark ("?") will generally tell you, via a message in the help window, what Kermit is expecting you to type at that point. For example, if you type a "?" immediately after the HP-Kermit> prompt, Kermit will print a list of the valid commands in the help window. Keywords, such as commands and parameter names, can be abbreviated to as few characters as makes the keyword unambiguous. If you type "rec ?" Kermit will recognize the abbreviation for the RECEIVE command, and then print "Input filespec" in the help window in response to the "?". Program structure and internals ------------------------------- System dependencies ------------------Since this implementation is intended to run only on HP equipment, in particular the 9836 workstation, it takes advantage of the HP Pascal language extensions and operating system features, even where this might make it non-transportable. The program uses the following non-standard features: modules - The program consists of several modules, which reside in several different files. string data types - used extensively in all modules. try-recover error trapping mechanism parameters are stored in the file as a string of characters as would be sent in an initialization packet. This didn't turn out to be very useful though, as I instead set the defaults using the relevant CONSTs DEFxxxxx rather than try to figure out how to encode the parameters by hand. The parameters in KERMIT.PRM will override the CONSTs if it exists. If KERMIT.PRM does not exist, the program will just ignore it. (To see if KERMIT.PRM exists, the parameter setting code calls the Exists procedure (in KRMIO.TEXT), which sets a trap on file open errors, tries to open the file, notices whether the trap was taken, and resets the file error trap.) Program structure: This implementation of KERMIT is composed of seven modules: main program is the top level program KRMCMD provides a user command interface modeled after, but not nearly as comprehensive as, the TOPS-20 COMND facility. KRMGUTS contains the routines and data structures that actually implement the KERMIT protocol. ERR_CODES defines the error codes used to identify error and status conditions KRMRPT provides a uniform error reporting and status display facility KRMIO supports the special eight-bit file and serial port I/O facilities needed by KRMGUTS WINDOWLIB provides a rudimentary text window facility, wherein the screen is partitioned into a number of rectangular regions (windows), in which text may be displayed. The modules reside in six files, as follows: File -------KRMMAIN Modules -----------main program KRMGUTS KRMCMD KRMIO KRMWNDW KRMRPT KRMGUTS KRMCMD KRMIO WINDOWLIB ERR_CODES KRMRPT The heirarchical relation among the modules is as follows: KRMMAIN KRMCMD KRMGUTS KRMIO KRMRPT/ERR_CODES KRMWNDW The modules in the left column comprise the user interface, whereas the modules in the right column implement the Kermit protocol. The modules KRMRPT and ERR_CODES, which provide the error and status reporting mechanism, are used by all modules above them. The functions performed by each of the modules is described below. KRMGUTS is the module that does all the work - it actually implements the Kermit protocol. The other modules just interface it to the operating system's file and serial port I/O, and provide a way for the user to type commands to KRMGUTS. ----Date: 20 Nov 85 21:59:33 EST From: Mike Gallaher <Gallaher@BLUE.RUTGERS.EDU> Subject: HP98xx kermit support Please remove my name from the list as the support contact for HP98xx kermit. There are no 98xx's where I now work... I had forgotten I was still on the list until I found a couple of queries in my mailbox! The only machine that the HP98xx kermit was actually run on here was the 9836. HP Pascal is supposed to be, and seems to be, portable across at least the 98xx line. The only questions that people asked me seemed to arise from library functions moving around in the newer HP releases, which were solved by looking in their documentation and using the librarian to hunt them down. Sorry I can't provide more details than that... thanks, Mike Gallaher -------