Beam Test Hardware Delivery Status Eduardo do Couto e Silva

advertisement
GLAST LAT Project
Test Beam Meeting, Apr 18, 2006
Beam Test Hardware Delivery Status
Eduardo do Couto e Silva
February 18, 2006
E. do Couto e Silva
1/2
GLAST LAT Project
Test Beam Meeting, Apr 18, 2006
High Level Schedule for Hardware
•
•
•
•
•
•
•
•
•
Review of Flight Hardware Handling Plan
– April 14
Arrival of Ancillary Detector from Bari
– April 27
Arrival from CU Hardware from SLAC
– May 2
Start of CU System tests
– May 15
Workshop 2 in Pisa
– May 15-18
CU and Ancillary Systems Test
– June 19
Workshop 3 in Pisa
– mid June?
Arrival of Hardware at CERN
– July 24
PS Beam Test Starts
– July 27
E. do Couto e Silva
2/2
GLAST LAT Project
Test Beam Meeting, Apr 18, 2006
Update on Reviews
•
Flight Hardware Handling Plan
– Recommendations from Review on Friday (April 14, 2006)
– verify that 1x4 grid has been load tested with dummy loads before we
proceed with hardware integration
» including rotations and additional loads due to transportation)
– avoid usage of water as coolant
– provide control and monitor temperatures and relative humidity
» avoid condensation
– using dray air bottles instead of Nitrogen for transportation from Pisa to
CERN.
– Have one general Healthy & Safety responsible for all operations.
– Ship the assembled unit back to SLAC instead of separate items.
– Outcome
– Praise to Italian Collaborators (Luca et al) for preparing the review
– We were authorized to ship flight hardware spares to Italy
– Upcoming Reviews by the end of the month
– MGSE
– CU procedure for integration (LAT-PS-8132)
E. do Couto e Silva
3/2
GLAST LAT Project
Test Beam Meeting, Apr 18, 2006
Hardware Delivery from SLAC
•
Monday April 17, 2006
– TKRFM8
– ACD FREE card + 2 ACD Tiles
– Breakout Boxes
– the polarity is not standard in one of them. Jeff Tice will send details to Italy
•
Tuesday April 18, 2006
– CAL FM101, CAL FM109
•
Upcoming deliveries by May 10 (hopefully)
– ACD cables (@ SLAC)
– already tested at SLAC, will be sent by FedEx
– Remaining 3 ACD tiles (@ SLAC)
– to be removed from the QualUnit after agreement with I&T
– Two 28 V power supply with remote control
– sent to company to be converted to 240 V and recalibrated
– EGSE for data taking
– need feedback ASAP so that we can start procurement
– see next slides
•
Anything else missing?
E. do Couto e Silva
4/2
GLAST LAT Project
Test Beam Meeting, Apr 18, 2006
CAL Comprehensive Performance Tests @ SLAC
•
Eduardo asked Luca, Johan and
David to look at the data in detail
– 10 min muon run had wrong
thresholds
– but FLE trigger works
E. do Couto e Silva
5/2
GLAST LAT Project
Test Beam Meeting, Apr 18, 2006
EGSE Description (from Ric)
May change after feedback from CERN (via Pasquale)
•
CISCO switch and shelves
– standard 19 inch rack
•
3 computers
• 2 Dell 1850 with a KVM switch
•
Uninterrupted Power Supplies
– back-up and filtering
•
Need feedback to start procurement !!!
– CERN requirements on
– firewall, switches, IP addresses
» current baseline NO firewall
– Pasquale is in contact with CERN
–
UPS requirements
• filtering and power back-up
– Gary is investigating that at SLAC
–
Control Room Requirements
• Cable lengths, space in the control
room, space in rack , are shelves
needed?
– Who?
E. do Couto e Silva
6/2
Diagram from Luca Latronico
PWR1
28V PS
Gary is looking into grounding issues
and will consult with Mike Huffer
TEM
TEM
XXX
VL
BBB
MC
RRR
EB
DDD
TEM
GASU
TPS
GRID
CHO
TKR
Therm
CAL
ISC
TPS
TPS
GND
INS
XY table
INS
XY table motor
PWR2
PWR3
LEGEND
PWR – Multiple power plug
INS - Electrical insulating layer
CHO-Therm – electrical insulator,
thermal conductive for heat dissipation
Control/Signal connection
Page Number
Power connection (including ground)
Direct electrical connection (ground)
VME2
Ancillary
Systems