2150 version 3 28-Jun-16 1 of 3 PLUMBING Design water supply backflow protection systems level: 5 credit: 6 planned review date: April 1998 sub-field: Plumbing, Gasfitting and Drainlaying purpose: This unit standard is for people who work, or intend to work in plumbing. People credited with this unit standard will be able to determine system requirements and design water supply backflow protection systems. entry information: Open. accreditation option: Evaluation of documentation and visit by NZQA and industry. moderation option: A centrally established and directed national moderation system has been set up by The Skills Organisation. special notes: New Zealand Building Code and Approved Documents:, G10 Piped Services, G12 Water Supplies, Manufacturers' specifications, Water supply protection regulations, NZS 3501: 1976, NZS 4219: 1983, NZS 5807 Part 2: 1980, BS 1723 Part 1: 1986, BS 1845: 1984, AS 1167 Part 1: 1984, AS 3500 Part 1: 1992, Health and Safety in Employment Act 1992. New Zealand Qualifications Authority 2016 2150 version 3 28-Jun-16 2 of 3 PLUMBING Design water supply backflow protection systems Elements and Performance Criteria element 1 Determine water supply backflow protection system requirements. performance criteria 1.1 Water supply backflow hazard is identified and listed. 1.2 Hazard type is categorised in accordance with Acts and Codes, refer special note. 1.3 Devices and components are selected in accordance with Acts and Codes, refer special note. element 2 Design water supply backflow protection system. Range: air gap, reduced pressure backflow prevention device, double check valve, hose connection vacuum break, single check valve. performance criteria 2.1 The water supply backflow protection systems are explained 2.2 Water supply backflow protection system design and detail specifications conform to provisions of Acts, Standards Codes and manufacturers' instructions, refer special note. New Zealand Qualifications Authority 2016 2150 version 3 28-Jun-16 3 of 3 PLUMBING Design water supply backflow protection systems element 3 Maintain safe working environment. performance criteria 3.1 Work practices are carried out without injury to worker, public, or damage to building, other services, tools or equipment, refer special note. Comments to: The Skills Organisation Freepost 5164 PO Box 24-469 Royal Oak Auckland 1345 . Please Note: Providers must be accredited by the Qualifications Authority before they can offer programmes of education and training assessed against unit standards. Accredited providers assessing against unit standards must engage with the moderation system that applies to those unit standards. [Please refer to relevant Plan ref: 0008] New Zealand Qualifications Authority 2016