6117 version 6 Page 1 of 3 Apply paper faced plaster cove Level 2 Credits 2 Purpose People credited with this unit standard are able to fix and finish paper faced plaster cove to wall and ceiling areas, and clean up after work is completed. Subfield Construction Trades Domain Plaster Board Status Registered Status date 20 April 2006 Date version published 25 January 2008 Planned review date 31 December 2011 Entry information Open. Accreditation Evaluation of documentation and visit by NZQA and industry. Standard setting body (SSB) Building and Construction Industry Training Organisation Accreditation and Moderation Action Plan (AMAP) reference 0048 This AMAP can be accessed at http://www.nzqa.govt.nz/framework/search/index.do. Special notes 1 All work practices must comply with the following: Health and Safety in Employment Act 1992; Health and Safety in Employment Regulations 1995; Resource Management Act 1991; Building Act 2004; AS/NZS 2589:2007 Gypsum linings – Application and finishing, available from Standards NZ (http://www.standards.co.nz); Approved Code of Practice for the Safe Erection and Use of Scaffolding (Wellington: Occupational Safety and Health Service, Department of Labour, 1995) available at http://www.osh.govt.nz. 2 Credit for this unit standard can be achieved on site through a registered assessor, or off site with an accredited training provider. New Zealand Qualifications Authority 2016 6117 version 6 Page 2 of 3 Elements and performance criteria Element 1 Fix and finish paper faced plaster cove to wall and ceiling areas. Performance criteria 1.1 Substrate surface is checked for suitability for fixing and finishing of paper faced plaster cove in accordance with the manufacturer’s recommendations. 1.2 Access for wall and ceiling areas is arranged and complies with the Health and Safety in Employment Regulations 1995. 1.3 Paper faced plaster cove is fixed and finished to requirements of the manufacturer and in accordance with site practice. 1.4 All operations are completed without damage to the workplace, tools, or plant. Element 2 Clean up after work is completed. Performance criteria 2.1 Tools and plant are maintained, cleaned, and stored in accordance with site practice. 2.2 Waste material is disposed of and workplace is cleaned in accordance with site practice. Please note Providers must be accredited by NZQA, or an inter-institutional body with delegated authority for quality assurance, before they can report credits from assessment against unit standards or deliver courses of study leading to that assessment. Industry Training Organisations must be accredited by NZQA before they can register credits from assessment against unit standards. Accredited providers and Industry Training Organisations assessing against unit standards must engage with the moderation system that applies to those standards. New Zealand Qualifications Authority 2016 6117 version 6 Page 3 of 3 Accreditation requirements and an outline of the moderation system that applies to this standard are outlined in the Accreditation and Moderation Action Plan (AMAP). The AMAP also includes useful information about special requirements for organisations wishing to develop education and training programmes, such as minimum qualifications for tutors and assessors, and special resource requirements. Comments on this unit standard Please contact the Building and Construction Industry Training Organisation national.office@bcito.org.nz if you wish to suggest changes to the content of this unit standard. New Zealand Qualifications Authority 2016