6238 version 5 Page 1 of 4 Operate a knapsack motorised mist blower for agrichemical application Level 3 Credits 6 Purpose People credited with this unit standard are able to: prepare the knapsack motorised mist blower for use; operate the knapsack motorised mist blower; and carry out post-operational procedures. Subfield Rural Contracting Domain Agrichemical Application Status Registered Status date 25 June 2007 Date version published 25 June 2007 Planned review date 31 December 2012 Entry information Open. Accreditation Evaluation of documentation and visit by NZQA and industry. Standard setting body (SSB) Infrastructure ITO Accreditation and Moderation Action Plan (AMAP) reference 0101 This AMAP can be accessed at http://www.nzqa.govt.nz/framework/search/index.do. Special notes 1 The following legislation and requirements apply to this unit standard: Hazardous Substances and New Organisms Act 1996; Health and Safety in Employment Act 1992; Resource Management Act 1991; NZS 8409:2004 Management of agrichemicals (NZS 8409), available from http://www.standards.co.nz; Guidelines for the Provision of Safety, Health and Accommodation in Agriculture (Wellington: Department of Labour, 1996), available from http://www.osh.govt.nz/order/catalogue; Territorial authority and/or regional council (TA/RC) requirements; Label directions; Manufacturer’s instructions. New Zealand Qualifications Authority 2016 6238 version 5 Page 2 of 4 Any legislation or other requirement superseding any of the above will apply, pending review of this unit standard. 2 Assessment against this unit standard must be based on evidence from a workplace context. 3 Personal protective equipment, appropriate to job requirements, is to be selected and used in accordance with company requirements, NZS 8409, and manufacturer’s instructions. 4 Definitions Agrichemical – any substance, whether inorganic or organic, man-made or naturally occurring, modified or in its original state, that is used in any agriculture, horticulture, or related activity to eradicate, modify, or control flora or fauna. Company requirements refer to all policies, procedures, and methodologies the candidate’s organisation has in place including but not limited to those relating to health, safety, environment, quality, and operations. Manufacturer’s instructions may include specifications, installation, handling, use, and maintenance instructions and safety data sheets. ULV – ultra-low volume. Elements and performance criteria Element 1 Prepare the knapsack motorised mist blower for use. Performance criteria 1.1 Mist blower is checked for function and soundness in accordance with company requirements. Range tank, hose lines, screens and/or filters, nozzles, ULV slides, power pack. 1.2 Mist blower is adjusted for use in accordance with manufacturer’s instructions, company requirements, and intended use. 1.3 Mist blower is fuelled ready for operation and in accordance with manufacturer’s instructions. 1.4 Mist blower is calibrated for the task specified in accordance with NZS 8409 and manufacturer’s instructions. Range standard volume, ULV. New Zealand Qualifications Authority 2016 6238 version 5 Page 3 of 4 Element 2 Operate the knapsack motorised mist blower. Performance criteria 2.1 Operation produces consistent and complete coverage with minimal overlaps. 2.2 Chemical trespass is avoided. 2.3 Any blockages are rectified in accordance with manufacturer’s instructions and company requirements. Element 3 Carry out post-operational procedures. Performance criteria 3.1 Contaminating residues are removed and washings are managed, in accordance with NZS 8409 and TA/RC requirements. Range equipment, protective clothing. 3.2 Any surplus agrichemical mix is managed in accordance with NZS 8409 and TA/RC requirements. 3.3 Any damage or faults including any missing, bent, broken, or loose parts are identified and are repaired, replaced, or reported in accordance with manufacturer's instructions and/or company requirements. 3.4 Equipment is stored in a safe condition and location in accordance with NZS 8409 and company requirements. 3.5 Application records are made in accordance with NZS 8409 and TA/RC, company, and client requirements, and are stored in accordance with company requirements. Please note Providers must be accredited by NZQA, or an inter-institutional body with delegated authority for quality assurance, before they can report credits from assessment against unit standards or deliver courses of study leading to that assessment. Industry Training Organisations must be accredited by NZQA before they can register credits from assessment against unit standards. Accredited providers and Industry Training Organisations assessing against unit standards must engage with the moderation system that applies to those standards. New Zealand Qualifications Authority 2016 6238 version 5 Page 4 of 4 Accreditation requirements and an outline of the moderation system that applies to this standard are outlined in the Accreditation and Moderation Action Plan (AMAP). The AMAP also includes useful information about special requirements for organisations wishing to develop education and training programmes, such as minimum qualifications for tutors and assessors, and special resource requirements. Comments on this unit standard Please contact Infrastructure ITO askus@infratrain.co.nz if you wish to suggest changes to the content of this unit standard. New Zealand Qualifications Authority 2016