Roadmap “Liquids-Platform”

advertisement
ROC800 MMI
(13RAS023)
Sales Training Update
Laura Gonzalez
Coriolis Interface Module-Agenda
• Coriolis Interface Module
• Features and Benefits
• The Coriolis Interface Solution
• Typical Applications
• Installation and Setup
• Compatibility
• Conclusion
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 2
Coriolis Interface Module
• Communicates directly with the core processor of Emerson
Coriolis meters (with an Intrinsically Safe barrier) and
transmitters
• Automatically retrieves data for monitoring and control of
–
–
–
–
Key Operating Data
Calibration Information
Diagnostics Information
Can calculate flow based on MODBUS data no pulse transmitter
required
• Communicates with up to six Coriolis Meters in the ROC800
(up to four in the FB107)
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 3
Features and Benefits
• Enables on line calibration using ROCLINK800
• Enables diagnostics with quick access to Coriolis data
• With ROCLINK800 - control and monitor features such as:
– Meter Zeroing
– Smart Meter Verification (SMV)
– Transient Bubble Remediation (TBR)
– Transient Mist Remediation (TMR)
*new*
– Production Volume Reconciliation (PVR)
calculations
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 4
*new*
- Net oil
The Coriolis Interface Solution
Intrinsically Safe
Barrier
Coriolis Interface
Module
• Keep the pulse transmitter - Meet API Chapter 11
• Replace transmitter with IS barrier - Increase value
to customer
- Easier to maintain (only one config tool)
- Reduce total cost of ownership
- Make Allocation measurements
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 5
Typical Applications
• Monitor well head separator performance
• Monitor two phase separators with Gas and Liquid
flow and percent water (Net Oil) calculations
• Monitor three phase separators with Gas, Oil and
Water outputs.
• Measure flow from tanks and LACT skids for truck
loading and unloading
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 6
Installation and Setup
• The Application Guide Part D301753X012 describes the
installation and set up procedure for the ROC800L and the
FB107
• This is similar to the Guide used in the training for the
FB107
• The new areas are
– Adding of TMR and PVR to the Module
– A modification to the setup for ROC800L Liquid Calcs
– A modification for the setup for the gas meter in the
ROC800L
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 7
Adding TMR and PVR
• The following display shows the addition of a panel that
defines the available options in the core processor
– PVR
– SMV
– TBR
– TMR
This defines the options that are available in the Coriolis Meter
being configured.
The calibration display, the diagnostics display and smart
meter verification display did not change
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 8
Coriolis Module Setup Display
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 9
TBR and TMR
• Transient Bubble Remediation (TBR)
– used to handle occasional gas bubbles or slugs of air in the
process fluid.
• Transient Mist Remediation (TMR)
*new with this release*
– used to handle occasional gas mist (water or oil)
appearances in gas flow
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 10
TBR Display
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 11
TMR Display
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 12
The PVR Function
• The PVR feature adds the ability to calculate the % water
content in the Liquid being measured.
• The data inputs required are:
– The reference temperature
– The Oil Base Density
– The Water Base density
• The Core processor then calculates the water cut, the
various flow rates and flow totals.
• This data is retrieved by the Coriolis Interface Module and is
available for use in the Gas measurement and Liquid
Measurement calculations
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 13
The PVR Display
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 14
Compatibility
Version 1.10 of the Coriolis Interface module is compatible
with the following:
– ROC800 v3.61
– ROC800L v1.41
– ROC800L Liquid Calcs User Program v1.04.00
– FB107 v1.70
– FB107 Liquid Allocation Mgmt User Program v1.00
– ROCLink800 v2.41
– Micro Motion Coriolis meter models 700 (v3.2 or later) and 800 (v3.9 or
later)
– Micro Motion Transmitter models 1500, 1700, 2500, 2700 and 3700
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 15
FAQs
• Does the module write down to the core processor?
– No, it does not.
• Can the APM for ROC800 be used instead of the
transmitter?
– No it cannot.
– For custody, a pulse for liquid is required but for gas MODBUS flow rates
can be used to do the gas calculation.
• Can we meet the AGA 1 second update standard?
– A four meter run will meet 1 second updates for AGA but the 6
meter run will not as it takes about 2 Seconds to update the 6
meters.
• Can the MODBUS registers be changed in the module?
– The MODBUS registers used in the CIM are fixed and cannot be
changed.
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 16
Conclusion: Measurement Challenges - Met
Challenge
Solution
Integration of Coriolis meters with
Emerson flow computers is
complicated, and our competitors
make it easy
Coriolis Interface Module
automatically links the MMI
Coriolis with FB107 and ROC800
Customers may not know how
Better monitoring of the separation
effective their production systems
and dump cycle process. (Beta
are – How many dump cycles?
test unit counted 2,000 + dump
How much accumulation of what?
cycles in a day)
Remote solar powered
installations require reduced
power.
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 17
Eliminate the need for transmitters
for reduced system power
requirements (Allocation
applications).
Questions?
• If you have any questions, please feel free to contact me at
LauraGonzalez@Emerson.com.
CIM Sales Training Update • Emerson Confidential • 7/2/15 • Slide 18