AD D E N D UM Addendum No: Project: 1 Cintas Center SAASS Interior Renovation Date: Project Number: June 17, 2015 15136.00 The following Addendum contains clarifications and revisions to the construction documents issued for bid 6/12/2015 for the above mentioned project. This addendum forms a part of the Contract Documents and modifies all previously issued specifications and drawings. Bidders shall update their Bidding Documents with the information contained in this Addendum. Where new Drawings are enclosed with this Addendum, discard the old Drawing and insert the new. Where Supplemental drawings (Sketches) are enclosed with this Addendum, attach the Supplemental drawing to the documents as noted. Where only written modifications are given, copy the information onto the appropriate Documents and note the Addendum number. All items contained herein shall be included with the Bid. Acknowledge receipt of this addendum by inserting the number and date on the bid form. Note: This addendum does not modify the bid due date of Friday, June 19th. General 1.A This addendum addresses questions received during / after the pre-bid meeting held on Monday, June 15, 2015 and provides clarification for the drawings issued for construction on June 12, 2015. 1.B Please include an additional line item allowance in bid proposal for “Pre-function Room Data/AV” in the amount of $2,750 total. This amount includes the control components for the space, which are not included in the drawings attached. These specific items are still being determined by Xavier. 1.C The permit application was submitted on June 2nd, 2015 to the City of Cincinnati. This was a comprehensive permit application including building, HVAC, plumbing, and electrical work to be completed for this project. 1.D Walls receiving custom paint colors (previously called out as part of a graphics package) are to be included in bids provided by general contractors of this project. See revised sheet A9.0 (attached) for paint selections and locations. Drawings 1.E Sheet: A1.0 a. Sheet Keynote 1.09 added to this drawing, indicating to remove ceiling and salvage lighting in existing lobby area. 1.F Sheet: A2.0 a. Sheet Keynote 2.09 has been updated to reflect the correct amount of four (4) TV’s in the array on the south wall of Pre-function Room #210. This note now includes a description of the type of TV to be installed. b. Sheet Keynote 2.10 has been added to Conference Room #218 for clarification. This TV location was previously called out on electrical drawings only. This note now includes a description of the type of TV to be installed. Addendum Date Page 2 of 4 1.G Sheet: A3.1 a. Interior elevations are included on this sheet showing the pre-function space and location of TV’s in the space. 1.H Sheet: A9.0 a. The surface material locations in the finish legend have been updated to reference the correct room numbers. 1.I Sheet: M2.1 a. This sheet has been updated to reference the correct room numbers and air handling unit types. 1.J Sheet: M5.1 a. The VAV Terminal Unit Schedule has been updated on this sheet. 1.K Sheet: E2.1 a. This sheet has been updated to reference the correct room numbers. 1.L Sheet: E3.1 a. This sheet has been updated to reflect the broadcasting AV requirements in Pre-Function Room 210 and now shows the correct room numbers. 1.M Sheet: E4.1 a. This sheet has been updated to reflect the broadcasting AV requirements in Pre-Function Room 210. 1.N Sheet: E5.2 a. The load calculations on this sheet now include the AV requirements for broadcasting in PreFunction Room 210. Questions Questions from D.A.G. Construction received on Monday, June 15th 1.O Question: Q: Will the owner’s furniture be removed prior to the demolition work starting? A: Owner is responsible for removal of existing furniture from the area of work. 1.P Question: Q: Drawing A2.0 note 2.03 references a branding package. Can you please explain what this is? A: The branding package will be a separate contract for work within the Cintas Center Student Athlete Academic Support Services area that is specific to signage, branding, and graphics. 1.Q Question: Q: Drawing A2.0 calls out the windows in the new construction. Is there a window on the north wall of room 218? If so, which window type is it? A: Window locations are called out on drawing A2.0 (attached). The north wall of Conference Room 218 shows a door and frame with glazing. See sheet A5.0 Building Details from the construction set for door, frame, and glazing information. Addendum Date Page 3 of 4 1.R Question: Q: In the [specifications] it shows the species/veneer for the wood door as per owner. Can you please advise door finish so that we can accurately price? A: Please match the finish of the existing doors to remain on Classroom 202, 203, and 204. 1.S Question: Q: Drawing A9.0 finish legend calls for SS-1 (solid surface countertop) for room 102. Can you please advise where room 102 is? A: Please see the revised drawing A9.0 Finish Plan and Schedule (attached) for finish locations and information. 1.T Question: Q: Drawing A9.0 calls for carpet in the existing electrical room. Do you want carpet installed in this area? A: See revised drawing A9.0 (attached) showing Electrical Room 212 with a concrete floor finish. 1.U Question: Q: Drawing A2.0 references interior elevations on A3.1. Can you please send me drawing A3.1? I did not get in the original packet from the university A: The drawing is issued as an attachment to this addendum. Question from Mayers Electric received on Monday, June 15th 1.V Question: Q: Is there [an] electrical specification for the project? What is the spec on the TV's? A: The seven (7) total TV’s in the project should all be the same type – 60” LED TV with ultra-thin bezel as required for TV array installation as indicated in the attached drawings. Questions from Wise Construction Company received on Tuesday, June 16th 1.W Question: Q: Do the electricians provide patch work where they install blocking for the T.V. Brackets? A: Any blocking and patching at TV locations should be coordinated between your electrician and drywall repair subcontractors. 1.X Question: Q: Has the VCT Mastic been tested for asbestos? A: The VCT and mastic were installed in 2000 and 12”x12” dimensions; therefore, they are nonasbestos containing materials. 1.Y Question: Q: Can drywall “Knock Down” frames be used to expedite the schedule? A: Please match the existing frame types that have been used in the space and coordinate new finishes with drawings A5.0 Building Details (provided in the For Construction Set) and A9.0 Finish Plan and Schedule (attached). 1.Z Question: Q: Is [there] 24 hour access [to the job site]? A: This can be arranged with owner. Question received from Beischel Building Company on Tuesday, June 16th 1.AA Question: Addendum Date Page 4 of 4 Q: We need direction on the VAV’s. The model number in the schedule is for a fan powered box. The detail / plan appears to show a regular box. There is quite a cost difference between the two [styles] of VAV’s. Also, the price model FDCG shown on the schedule has been discontinued. Please advise. A: Please see the revised Mechanical Drawings (attached) for unit types and locations. Question received from Atkins & Stang, Inc. on Wednesday, June 17th 1.BB Question: Q: Bid form calls for the EC to provide Voice Data, Televisions, AV wiring. Where is the VD closet? No specification were issued specifically on TV, AV A: The voice data is located in the electric closet, Room 212. Summary of Attachments Drawings A1.0 A2.0 A3.1 A9.0 M2.1 M5.1 E2.1 E3.1 E4.1 E5.2 Mezzanine Level Demo Plans Mezzanine Level Construction Plan Interior Elevations Finish Plan and Schedule Mechanical Mezzanine Level Floor Plan HVAC Details Electric Lighting Mezzanine Level Floor Plan Electric Power Mezzanine Floor Plan Electric Systems Mezzanine Floor Plan Electric Details END OF ADDENDUM 20150615_Addendum 001.doc 06/17/2015 06/17/2015 06/17/2015 06/17/2015 06/17/2015 06/17/2015 06/17/2015 06/17/2015 06/17/2015 06/17/2105 SHEET KEYNOTES 1.01 1.01 1.01 NO WORK IN THIS AREA. 1.02 REMOVE EXISTING WALL, DOOR, FRAME, AND ALL COMPONENTS IN ITS ENTIRETY. 1.03 REMOVE EXISTING 2X2 LIGHTS. EXISTING CEILING GRID TO REMAIN. 1.04 REMOVE WALL TO EXTENTS SHOWN. 1.05 REMOVE FLOOR SURFACES TO EXTENTS SHOWN. 1.06 REMOVE CEILING AND EXISTING LIGHTING TO EXTENTS SHOWN. 1.07 REMOVE FRP FROM ALL WALLS TO REMAIN. 1.08 REMOVE SAFE. 1.09 REMOVE CEILING AND SALVAGE EXISTING LIGHTING. COORDINATE REMOVAL OF SALVAGED LIGHTING WITH OWNER. 1.05 1.06 1 1.01 1.01 MICHAEL N. SCHUSTER #7088 EXP. DATE: 12/31/2015 1.01 1.01 22 22 1.03 1.01 1.03 21 1.03 21 1.05 1.01 1.01 1.03 1.03 20 20 1.03 UP 1.03 1.01 1.01 1 19 19 1.05 1.03 1.05 25 25 1.05 1.03 1.01 1.01 GENERAL NOTES 1.03 1.02 A. 1.09 18 18 B. C. C:\Users\lpetrakis\Documents\CINTAS-SAASS_CENTRAL_v14_lpetrakis.rvt D. 1.05 1.01 1.05 1.05 1.06 1.04 1.07 17 17 E. F. G. 1.05 H. 1.06 I. 1.08 6/17/2015 1:51:46 PM J. 16 16 2 A1.0 PARTIAL DEMO RCP MEZZANINE LEVEL 1/8" = 1'-0" 1 A1.0 PARTIAL DEMO PLAN MEZZANINE LEVEL 1/8" = 1'-0" SEE ALSO CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE SUPPRESSION, AND STRUCTURAL DRAWINGS AND SPECIFICATIONS. GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER FOR SALVAGE OF EXISTING MATERIALS BY OWNER. PROVIDE MINIMUM THREE BUSINESS DAYS' NOTICE PRIOR TO DEMOLITION ACTIVITIES TO ALLOW OWNER TO EXAMINE EXISTING CONDITIONS AND SALVAGE MATERIALS. COORDINATE DEMOLITION WITH STRUCTURAL DRAWINGS FOR EXISTING STRUCTURE TO REMAIN AND RE-SUPPORT / MODIFICATION OF EXISTING STRUCTURE TO REMAIN. REMOVE ALL EXISTING CONSTRUCTION IN CONFLICT WITH NEW WORK WHETHER OR NOT SPECIFICALLY INDICATED IN THE DRAWINGS. DEMOLITION SHALL INCLUDE, BUT IS NOT LIMITED TO, ALL FLOOR COVERINGS, BASE, RESIDUAL ADHESIVE STAPLES AND NAILS IN FLOOR, WALL COVERINGS, HARDWARE, DOORS, FRAMES, CASEWORK, ABANDONED SUPPORTS, FASTENERS, TRIM, INTERIOR PARTITIONS, ACOUSTIC CEILING PANELS, T-BAR CEILING GRIDS, FLOOR DEVICES, AND ANY OTHER ITEMS AS NOTED ON DRAWINGS. REMOVE ALL PLUMBING, HVAC, AND ELECTRICAL COMPONENTS THAT ARE ASSOCIATED WITH DEMOLISHED WALLS, CEILINGS AND AS NOTED. ALL CEILINGS ARE TO BE REMOVED TO THE DECK UNLESS OTHERWISE INDICATED. REMOVE ALL DEMOLITION DEBRIS FROM SITE AND DISPOSE OF LEGALLY. PATCH PENETRATIONS IN FLOOR AND WALLS RESULTING FROM DEMOLITION. RESTORE DAMAGE TO FIRE-RATED SYSTEMS INCLUDING FIREPROOFING. COORDINATE DEMOLITION OF EXISTING BUILIDNG MASONRY WITH EXISTING CONSTRUCTION (LINTELS / CONTROL JOINTS). PATCH BACK AND TOOTH IN NEW MASONRY AS REQUIRED TO RESTORE EXISTING AREAS AFFECTED BY NEW WORK. PROTECT ALL EXISTING LANDSCAPE TO REMAIN. COORDINATE REMOVAL OF EXISTING LANDSCAPE PLANT MATERIAL FOR POSSIBLE STOCKPILING BY OWNER. COORDINATE WITH OWNER AND LANDSCAPE DRAWINGS. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR STOCKPILING EXISTING TOPSOIL FOR REUSE IN NEW WORK. PLUMBING DEMOLITION: REMOVE ALL PIPING ASSOCIATED WITH FIXTURES / DEVICES THAT ARE TO BE REMOVED. REMOVE BACK TO NEAREST JUNCTION AND CAP. ALL TERMINATIONS SHALL BE CONCEALED BEHIND WALLS OR CEILINGS. REMOVE ALL OLD PLUGGED OR CAPPED PIPES BACK BEHIND FINISHED WALL SURFACE. WHERE PIPING BRANCHES ARE COMPLETELY ELIMINATED, REMOVE BACK TO MAIN DISTRIBUTION. ELECTRICAL DEMOLITION: REMOVE CONDUIT AND WIRE ASSOCIATED WITH DEMOLISHED ELECTRICAL DEVICES BACK TO NEXT ACTIVE DEVICE OR PANELBOARD IF THE CIRCUIT IS COMPLETELY UNLOADED. WIRING SHALL REMAIN WHERE CIRCUITS ARE REQUIRED TO SERVE NEW LOADS OR ELECTRICAL ITEMS THAT ARE REPLACED. Xavier University 1624 Herald Avenue Cincinnati, OH 45207 1.01 Cintas Center SAASS Interior Renovation 1.03 THIS DRAWING AND THE DESIGN CONCEPTS REPRESENTED, AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF MICHAEL SCHUSTER ASSOCIATES INC., AND MAY NOT BE USED, REPRODUCED, OR COPIED IN WHOLE OR PART, FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION OF MICHAEL SCHUSTER ASSOCIATES INC. Copyright Michael Schuster Associates, Inc. dba MSA Architects All Rights Reserved MSA Sport is a division of MSA Architects DATE ISSUED 05/29/2015 06/12/2015 FOR PERMIT FOR CONSTRUCTION NO. DATE 1 REVISION 06/17/2015 ADDENDUM 1 PROJECT NO. 15136.00 DRAWING TITLE MEZZANINE LEVEL DEMO PLANS A1.0 221 STUDY 221 7' - 6" 82 .0 0° 9' - 0" WOMEN'S 207 Sim 13 A5.0 5' - 2 1/2" 26 2. 00 ° 207 6' - 0" CLEAR 8.01 2.01 PROVIDE PLASTIC LAMINATE COUNTERTOP WITH STEEL ANGLE SUPPORTS. REFER TO SHEET A5.0 FOR DETAILS. 2.02 PROVIDE PLASTIC LAMINATE MILLWORK BASE AND WALL CABINETS WITH SOLID SURFACE COUNTERTOP AND COUNTER-MOUNTED SINK. REFER TO SHEET A9.1 FOR DETAILS. 2.03 BRANDING WALL LOCATION. REFER TO BRANDING PACKAGE FOR BLOCKING REQUIREMENTS. 2.04 PROVIDE LED COVE LIGHTING AT THIS LOCATION, FULL HEIGHT OF WALL. COLOR: XAVIER BLUE. 2.05 COPIER/PRINTER BY OWNER. 2.08 ALIGN FINISH FACE OF NEW WALL WITH FACE OF EXISTING WALL. 221A 220A 209 CIRCULATION 209 9' - 0" 220 11' - 3 3/8" 8.07 SHEET KEYNOTES 2.08 STUDY 220 W3 STAIR #1 9' - 0" 9' - 0 7/8" ELEV MEN'S 208 208 2.09 INSTALL ARRAY OF 4 (FOUR) NEW 60" LED TV'S WITH ULTRA-THIN BEZEL THIS AREA. PROVIDE BLOCKING AS NEEDED. SEE ELECTRICAL DRAWINGS. COORDINATE LOCATION / MOUNTING HEIGHT WITH OWNER. 2.10 INSTALL ONE (1) NEW 60" LED TV WITH ULTRA-THIN BEZEL THIS AREA. PROVIDE BLOCKING AS NEEDED. SEE ELECTRICAL DRAWINGS. COORDINATE LOCATION / MOUNTING HEIGHT WITH OWNER. 8.01 GWB SOFFIT. REFER TO CEILING DETAILS FOR MORE INFORMATION. 8.02 LINEAR WALLWASHER LIGHT. REFER TO ELECTRICAL DRAWINGS. 8.03 SPECIALTY ACCENT LIGHTING. REFER TO ELECTRICAL DRAWINGS. 8.04 LED COVE LIGHTING AT THIS LOCATION. REFER TO ELECTRICAL DRAWINGS. 8.06 LINEAR, SUSPENDED LIGHT. BOTTOM OF FIXTURE @ 22'-0" AFF. REFER TO ELECTRIAL DRAWINGS, TYP. OF (10) 8.07 RECESSED CAN LIGHT. REFER TO ELECTRICAL DRAWINGS. 210 8.08 FULL, UNCUT 2X2 TILE. 26' - 0" 8.09 FLOORING TRANSITION BELOW, SHOWN F.R.O. LIGHT FIXTURES TO ALIGN TO FLOORING EDGE. STAIR #2 22 2' - 6" 22 1 204 2.10 21 21 8.09 9 EQUAL SPACES = 76' - 10" 8.03 PRE-FUNCTION 210 203 A3.1 CLASSROOM 203 1 8.06 TYP. 2 2.10 20 20 UP 22' - 0" CLASSROOM 202 STAIR #3 202 REFLECTED CEILING PLAN LEGEND 2.09 2' - 6" 2.03 2.04 19 1 A5.0 205 211 25 6' - 10 3/4" CORRIDOR 211 3 A5.0 6/17/2015 1:51:58 PM 8.01 215A 2.08 2 A5.0 11 1/8 " 2.03 8.07 Sim 4 A5.0 216 9' - 0" 6' - 8" ° .00 135 217 217A 9' - 0" 1 2' 4" 2.02 7 A5.0 217B 135. 00° W1 17 2.04 ALL INTERIOR PARTITION WALLS SHALL BE "G1-A" WITH PARTITION MODIFIER "b" UNLESS NOTED OTHERWISE. REFER TO SHEET A6.1 FOR PARTITION TYPES. B. ALL INTERIOR COLUMN WRAPS SHALL BE "G2-A" WITH PARTITION MODIFIER "b" UNLESS NOTED OTHERWISE. REFER TO SHEET A6.1 FOR PARTITION TYPES. C. COORDINATE FINAL PARTITION LOCATIONS WITH FURRING AT STRUCTURAL ELEMENTS. D. ALL INTERIOR DIMENSIONS ARE TO CENTERLINE OF STUD OR MASONRY UNLESS NOTED OTHERWISE. ANGLED WALL DIMENSIONS ARE TO INSIDE ANGLE OF WALL. E. ALL EXTERIOR AND EXISTING DIMENSIONS ARE TO FINISH FACE OF INTERIOR OF WALL. F. REFER TO SHEET A5.0 FOR OPENING TYPES AND ELEVATIONS. 21' - 0" A5.0 2.01 G. FINAL LOCATION OF WALL-MOUNTED SWITCHES AND A/V CONTROLS SHALL BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. H. ALL DOOR FRAMES TO BE LOCATED 4" FROM FACE OF SHEATHING OR MASONRY UNLESS NOTED OTHERWISE. I. SEE SHEET A9.0 FOR FINISH SCHEDULE INFORMATION. J. ALL FLOOR FINISH TRANSITIONS SHALL OCCUR AT THE CENTERLINE OF THE DOOR IN THE CLOSED POSITION OR THE CENTERLINE OF A FRAMED OPENING. CONSULT WITH ARCHITECT FOR ANY DISCREPENCIES. K. ALL FURNITURE & EQUIPMENT SHOWN IS FOR REFERNCE ONLY. OWNER TO PROVIDE ALL FURNITURE & EQUIPMENT UNLESS NOTED OTHERWISE. L. ALIGN INTERIOR WALLS WITH CENTERLINE OF EXTERIOR MULLIONS UNLESS NOTED OTHERWISE. M. FIELD VERIFY ALL DIMENSIONS AND FINAL CEILING ELEVATIONS. N. CONTRACTOR TO COORDINATE CEILING GRID LOCATION WITH ELECTRICAL DRAWINGS. THIS DRAWING AND THE DESIGN CONCEPTS REPRESENTED, AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF MICHAEL SCHUSTER ASSOCIATES INC., AND MAY NOT BE USED, REPRODUCED, OR COPIED IN WHOLE OR PART, FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION OF MICHAEL SCHUSTER ASSOCIATES INC. Copyright Michael Schuster Associates, Inc. dba MSA Architects All Rights Reserved MSA Sport is a division of MSA Architects DATE ISSUED . 05/29/2015 06/12/2015 . FOR PERMIT FOR CONSTRUCTION NO. DATE 1 REVISION 06/17/2015 ADDENDUM 1 218A 8.08 2.05 2.10 1 2.01 2.08 9' - 0" 219A STORAGE 219 1/8" = 1'-0" A. 5 COMPUTER ROOM 217 6 CONFERENCE 218 PARTIAL RCP MEZZANINE LEVEL OFFICE 216 216A 2.08 8' - 0" OFFICE 215 101 SF 9' - 0" 8 3/4" C:\Users\lpetrakis\Documents\CINTAS-SAASS_CENTRAL_v14_lpetrakis.rvt A5.0 W2 8' - 13 219 GENERAL NOTES ELECTRICAL 212 8' - 8 1/2" 215 7' - 0" 16 EXPOSED, SEE FINISH SCHEDULE 2.04 18 8.02 218 OFFICE 206 7' - 8 1/2" 8' - 10 7/8" 8.04 17 ACT-1, SEE FINISH SCHEDULE 2.04 212 8.04 OFFICE 205 213A 8.04 18 GYP., SEE FINISH SCHEDULE RECEPTION 213 CLASSROOM 201 206 9' - 0" 201 6" 2' - 2" 25 15 A5.0 213 9' - 0" 1' R2 15' - 1 5/8" 8.04 14' - 0 5/8" 19 Xavier University 1624 Herald Avenue Cincinnati, OH 45207 CLASSROOM 204 Cintas Center SAASS Interior Renovation 2.03 8.02 2 A2.0 MICHAEL N. SCHUSTER #7088 EXP. DATE: 12/31/2015 16 1 A2.0 PARTIAL FLOOR PLAN MEZZANINE LEVEL 1/8" = 1'-0" O. CONTRACTOR TO COORDINATE HVAC LAYOUT WITH MECHANICAL DRAWINGS. P. CONTRACTOR TO COORDINATE ALL SPRINKLER HEAD LOCATIONS WITH ELECTRICAL AND HVAC. REFER TO MEP DRAWINGS FOR MORE INFORMATION. Q. RECESSED LIGHT FIXTURES, SPRINKLER HEADS, AND CEILING MOUNTED DEVICES LOCATED IN ACT CEILINGS SHALL BE CENTERED WITHIN THE CEILING TILE, U.O.N. R. CENTER ACOUSTIC CEILING TILE GRID WITHIN ENCLOSED ROOMS, U.O.N. PROJECT NO. 15136.00 DRAWING TITLE MEZZANINE LEVEL CONSTRUCTION PLAN A2.0 Xavier University 1624 Herald Avenue Cincinnati, OH 45207 Cintas Center SAASS Interior Renovation MICHAEL N. SCHUSTER #7088 EXP. DATE: 12/31/2015 PAINT EXISTING CEILING SEE ROOM FINISH SCHEDULE. PAINT EXISTING CEILING SEE ROOM FINISH SCHEDULE NEW RECESSED LIGHT FIXTURES TYP. - SEE ELECTRICAL DRAWINGS ISSUED 06/12/2015 FOR CONSTRUCTION ARRAY OF FOUR (4) NEW 60" LED TV'S WITH ULTRATHIN BEZEL ADJACENT TO DISPLAY CONTINUOUS IMAGE ACROSS ALL SCREENS THIS LOCATION. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFO. PROVIDE BLOCKING AS NEEDED FOR MOUNTING EQ 2 A3.1 PRE-FUNCTION SOUTH WALL 1/8" = 1'-0" REVISION 06/17/2015 ADDENDUM 1 NEW 60" LED TV WITH ULTRA-THIN BEZEL THIS LOCATION. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFO. PROVIDE BLOCKING AS NEEDED FOR MOUNTING EQ EQ CL PAINT EXISTING GWB - SEE ROOM FINISH SCHEDULE FOR PAINT COLOR 1 A3.1 PRE-FUNCTION EAST WALL 1/8" = 1'-0" EQ EQ CL PROJECT NO. TYP. U.N.O. TYP. U.N.O. CUSTOM GRAPHICS THIS WALL - SEE BRANDING PACKAGE FOR ADDITIONAL INFO. EQ 1 NEW PENDANT LIGHT FIXTURE, TYP. SEE ELECTRICAL DRAWINGS. 9' - 2" AFF B/TV NEW PENDANT LIGHT FIXTURE TYP. - SEE ELECTRICAL DRAWINGS EXISTING GLAZING SHOWN F.R.O. 6/17/2015 3:00:50 PM DATE NO. DATE 9' - 2" AFF B/TV C:\Users\lpetrakis\Documents\CINTAS-SAASS_CENTRAL_v14_lpetrakis.rvt THIS DRAWING AND THE DESIGN CONCEPTS REPRESENTED, AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF MICHAEL SCHUSTER ASSOCIATES INC., AND MAY NOT BE USED, REPRODUCED, OR COPIED IN WHOLE OR PART, FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION OF MICHAEL SCHUSTER ASSOCIATES INC. Copyright Michael Schuster Associates, Inc. dba MSA Architects All Rights Reserved MSA Sport is a division of MSA Architects 15136.00 DRAWING TITLE INTERIOR ELEVATIONS A3.1 1 FINISH LEGEND FINISH KEY BASE RB-1 CEILING FINISH ACT-1 FINISH DESCRIPTION MANUFACTURER PRODUCT / STYLE COLOR SIZE SHEET KEYNOTES STUDY 221 REMARKS / INSTALLATION 9.01 BASE BID: PROVIDE PC-1 FLOORING THIS AREA. ALTERNATE 1: PROVIDE FLOORING AS SHOWN. AFTER REMOVAL OF EXISTING FLOOR COVERING, COORDINATE NEW FLOOR FINISH WITH ARCHITECT. 9.02 BASE BID: PROVIDE LVT-1 FLOORING THIS AREA. ALTERNATE 1: PROVIDE FLOORING AS SHOWN. AFTER REMOVAL OF EXISTING FLOOR COVERING, COORDINATE NEW FLOOR FINISH WITH ARCHITECT. 9.03 APPLY WC-1 TO THIS WALL, TO EXTENTS SHOWN. 9.04 START EDGE OF FINISH TREATMENT AT THIS CORNER. 9.05 APPLY PT-5 TO THIS WALL AT CUSTOM GRAPHICS LOCATION. SEE GRAPHICS PACKAGE FOR ADDITIONAL INFO. 9.02 RUBBER WALL BASE JOHNSONITE ACOUSTICAL CEILING TILE 6" COVE ARMSTRONG 63 BURNT UMBER ULTIMA HIGH NRC SUPRAFINE 9/16" GRID FLOOR FINISH CPT-1 CARPET TILE TANDUS HALFTONE CPT-2 CARPET TILE TANDUS HALFTONE TRANSITION CPT-3 CPT-4 LVT-1 CARPET TILE CARPET TILE LUXURY VINYL TILE TANDUS TANDUS JOHNSONITE HALFTONE HALFTONE I.D. FREEDOM WOODS IN SEASONED OAK BARREL PC-1 POLISHED CONCRETE WCPT-1 WALK-OFF CARPET WOMEN'S 207 WHITE WITH 24" x 24" SQUARE EDGE 18909 MINERAL ORE 18703 CYAN / MINERAL ORE 18913 CYAN 18910 PITCH FRE-P 4697 18" x 36" INSTALL ASHLAR PATTERN 18" x 36" INSTALL ASHLAR PATTERN 18" x 36" 18" x 36" 6" x 48" INSTALL ASHLAR PATTERN INSTALL ASHLAR PATTERN, LOCATED IN OFFICE/CONFERENCE AREAS MEN'S 208 CPT-1 / CPT-2 / CPT-3 ALTERNATES - COORDINATE WITH ARCHITECT AFTER REMOVAL OF EXISTING FLOORING TANDUS ABRASIVE ACTION II POWERBOND CLEAR STUDY 220 CIRCULATION 209 ELEV 122 6' WIDE ROLL 1 SURFACE MATERIAL PL-1 PLASTIC LAMINATE PL-2 PLASTIC LAMINATE SS-1 SOLID SURFACE FORMICA FORMICA CORIAN 3202-90 OTTER 837-58 GRAPHITE ANTRACITE GLOSS FINISH MATTE FINISH WALL FINISH DPT-1 PT-1 PT-2 PT-3 PT-4 PT-5 DRY ERASE PAINT PAINT PAINT PAINT CEILING PAINT PAINT TBD TBD TBD TBD TBD PORTER PAINTS TBD TBD TBD TBD FLAT TBD WHITE PT-6 PAINT PORTER PAINTS TBD WC-1 WALLCOVERING CARNEGIE XOREL METEOR MICHAEL N. SCHUSTER #7088 EXP. DATE: 12/31/2015 APPLY TO VERTICAL CABINET FACES, LOCATED IN ROOM 213 APPLY TO COUNTERTOP SURFACES, LOCATED IN ROOM 217 AND 213 COUNTERTOP, LOCATED IN ROOM 213 STAIR #2 117 1 WHITE XAVIER ATHLETIC BLUE TEAR DROP 517-2 W6427 752 CUSTOM COLOR ON XAVIER UNIVERSITY ACCOUNT 22 9.04 Cintas Center SAASS Interior Renovation CLASSROOM 204 ROOM FINISH SCHEDULE ROOM 1 NAME FLOOR FINISH BASE FINISH WALL FINISH Number MEZZANINE 201 202 203 204 205 NORTH EAST SOUTH WEST CEILING COMMENTS CLASSROOM CLASSROOM CLASSROOM CLASSROOM OFFICE CPT-4 RB-1 WC-1 (1) PT-3 PT-3 PT-3 (2) 206 OFFICE CPT-4 RB-1 PT-3 (1) PT-3 PT-3 PT-3 (2) 207 208 209 210 WOMEN'S MEN'S CIRCULATION PRE-FUNCTION (1) LVT-1 (1) PC-1 RB-1 RB-1 PT-2 PT-5(2) PT-2 PT-6 PT-2 PT-5(2) PT-2 PT-1 211 CORRIDOR (1) LVT-1 RB-1 PT-2 PT-2 / PT-5 (2) PT-2 PT-2 212 213 214 215 216 217 218 219 220 221 ELECTRICAL RECEPTION VESTIBULE OFFICE OFFICE COMPUTER ROOM CONFERENCE STORAGE STUDY STUDY CPT-4 CPT-4 WCPT-1 CPT-4 CPT-4 CPT-4 CPT-4 CPT-4 CPT-4 CPT-4 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 RB-1 PT-3 WC-1 PT-3 PT-3 PT-3 PT-3 PT-3 DPT-1 DPT-1 PT-3 PT-3 PT-3 PT-3 PT-3 PT-3 PT-3 DPT-1 DPT-1 PT-3 PT-3 PT-3 PT-3 PT-3 PT-3 PT-3 DPT-1 DPT-1 PT-3 PT-3 PT-3 PT-3 PT-3 PT-3 PT-3 DPT-1 DPT-1 ACT-1 / GYP (2) (1) SEE FINISH PLAN FOR ALT. FLOORING TYPE + LOCATION. (2) APPLY PT-4 AT GYP. SOFFIT LOCATION (3) (1) SEE FINISH PLAN FOR ALT. FLOORING TYPE + LOCATION. (2) CUSTOM GRAPHICS THIS LOCATION, BRANDING PACKAGE ISSUED SEPARATELY. (3) EXISTING CEILING TO REMAIN THIS AREA. APPLY PT-4 ACT-1 (1) SEE FINISH PLAN FOR ALT. FLOORING TYPE + LOCATION. (2) CUSTOM GRAPHICS THIS LOCATION, BRANDING PACKAGE ISSUED SEPARATELY (3) (3) EXISTING CEILING TO REMAIN THIS AREA. APPLY PT-4 ACT-1 / GYP (2) (1) APPLY PT-4 AT GYP. BOARD SOFFIT LOCATION ACT-1 ACT-1 ACT-1 ACT-1 ACT-1 ACT-1 ACT-1 21 (1) APPLY NEW FINISH OVER EXISTING DRY ERASE PAINT THIS LOCATION. (2) EXISTING CEILING TO REMAIN THIS AREA. APPLY PT-4 (1) APPLY NEW FINISH OVER EXISTING DRY ERASE PAINT THIS LOCATION. (2) EXISTING CEILING TO REMAIN THIS AREA. APPLY PT-4 4' - 6" PRE-FUNCTION 210 9.01 CLASSROOM 203 20 UP CLASSROOM 202 Xavier University 1624 Herald Avenue Cincinnati, OH 45207 9.04 19 9.03 OFFICE 205 RECEPTION 213 25 OFFICE 206 CLASSROOM 201 1 CORRIDOR 211 9.02 ELECTRICAL 212 THIS DRAWING AND THE DESIGN CONCEPTS REPRESENTED, AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF MICHAEL SCHUSTER ASSOCIATES INC., AND MAY NOT BE USED, REPRODUCED, OR COPIED IN WHOLE OR PART, FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION OF MICHAEL SCHUSTER ASSOCIATES INC. Copyright Michael Schuster Associates, Inc. dba MSA Architects All Rights Reserved MSA Sport is a division of MSA Architects 9.05 18 OFFICE 215 1 OFFICE 216 C:\Users\lpetrakis\Documents\CINTAS-SAASS_CENTRAL_v14_lpetrakis.rvt 9.05 FLOORING FILL LEGEND COMPUTER ROOM 217 17 CONFERENCE 218 CPT-4 CPT-2 WCPT-1 CPT-3 PC-1 A. STORAGE 219 16 1 A9.0 FINISH PLAN MEZZANINE LEVEL 1/8" = 1'-0" C. D. E. ISSUED 05/29/2015 06/12/2015 FOR PERMIT FOR CONSTRUCTION NO. DATE 1 REVISION 06/17/2015 ADDENDUM 1 LVT-1 GENERAL NOTES B. 6/17/2015 1:52:17 PM CPT-1 DATE ALL FLOOR FINISH TRANSITIONS SHALL OCCUR AT THE CENTERLINE OF THE DOOR IN THE CLOSED POSITION OR THE FINISH FACE OF A FRAMED OPENING. CONSULT WITH ARCHITECT FOR ANY DISCREPENCIES. UNLESS OTHERWISE NOTED, PAINT ALL GYP. BD. CEILINGS P-1. PAINT VERTICAL FACE OF SOFFITS TO MATCH ADJACENT PARTITION, UNLESS OTHERWISE NOTED. ALL WALLS SHALL BE PAINTED PT-1 WITH BASE RB-1, UNLESS OTHERWISE NOTED. USE JOHNSONITE SLIM LINE TRANSITION AS REQUIRED. CONFIRM ACCENT PAINT LOCATIONS W/ ARCHITECT PRIOR TO PAINTING. PROJECT NO. 15136.00 DRAWING TITLE FINISH PLAN AND SCHEDULE A9.0 GENERAL NOTES: A. ALL CONDUITS SHALL BE 3/4" UNLESS OTHERWISE NOTED. HOMERUNS: LESS THAN 50' - No. 12 CONDUCTOR 50' TO 100' - No. 10 CONDUCTOR 100' OR MORE - No. 8 CONDUCTOR ALL CONDUCTORS INCLUDING BRANCH CIRCUIT CONDUCTORS AND CONTROL WIRING SHALL BE INDIVIDUALLY IDENTIFIED AT BOTH ENDS AND AT EACH TERMINATION. C. ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH THE LATEST EDITIONS OF CODES AND STANDARDS AS FOLLOWS. ELECTRIC WORK SHALL BE PERFORMED IN ACCORDANCE WITH NFPA NATIONAL ELECTRIC CODE, NBS NATIONAL ELECTRIC SAFETY CODE, NFPA STANDARDS. ELECTRIC MATERIALS SHALL BE U.L. LISTED AND COMPLY WITH NEMA STANDARDS. D. METAL CONDUITS, WIREWAYS, AND EQUIPMENT ENCLOSURES SHALL NOT BE USED AS EQUIPMENT GROUND CONDUCTORS. E. ALL BRANCH CIRCUIT WIRING IN CHANNELS, WIREWAYS, FIXTURES OR CONDUITS SHALL BE TYPE THHN STRANDED AND FACTORY COLOR CODED. F. CONDUIT CONCEALED ABOVE CEILINGS OR IN WALLS SHALL BE EMT TYPE UNLESS OTHERWISE NOTED - SEE SPECS. THE ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND CHECK AND VERIFY ALL EXISTING CONDITIONS BEFORE BIDDING. ANY DISCREPANCIES DISCOVERED BETWEEN EXISTING CONDITIONS AT THE SITE AND THOSE SHOWN ON THE DRAWING SHALL BE REPORTED IMMEDIATELY TO THE ENGINEER, IN WRITING. H. ELECTRIC CONTRACTOR SHALL BE LICENSED AND CERTIFIED IN THE STATE OF OHIO. I. WHERE ANY NEW CONDUIT PASSES THROUGH EXISTING WALLS, ELECTRIC CONTRACTOR SHALL PROVIDE ALL CUTTING, PATCHING OF WALLS AND PROTECT OPENING WITH THROUGH-PENETRATION FIRESTOP SYSTEM. J. THE CONTRACTOR SHALL EXERCISE ADEQUATE PROTECTIVE AND SAFETY MEASURES FOR ALL PERSONS AND PROPERTY AND SHALL BE RESPONSIBLE FOR ANY DAMAGES OR INJURIES ARISING FROM THE EXECUTION OF THIS WORK. CODED NOTES: # 1. NO WORK TO BE PERFORMED IN THIS AREA. EXISTING TO REMAIN. 3. REMOVE EXISTING LIGHT FIXTURES IN THIS AREA. 5/29/2015 4:03:44 PM L:\ACAD\PROJECTS\MOTZ\XAVIER UNIVERSITY\XU.2014.06 (STUDENT ATHLETE ACADEMIC SUPPORT SERVICES)\E-2.1.DWG 2. A XU Cintas Center SAASS Interior Renovation G. O Xavier University 1624 Herald Avenue Cincinnati, OH 45207 B. THIS DRAWING AND THE DESIGN CONCEPTS REPRESENTED, AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF MICHAEL SCHUSTER ASSOCIATES INC., AND MAY NOT BE USED, REPRODUCED, OR COPIED IN WHOLE OR PART, FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION OF MICHAEL SCHUSTER ASSOCIATES INC. Copyright Michael Schuster Associates, Inc. dba MSA Architects All Rights Reserved MSA Sport is a division of MSA Architects DATE 06-12-15 NO. DATE 1 ISSUED FOR CONSTRUCTION REVISION 06-17-15 ADDENDUM 1 PROJECT NO. 15136.00 N W E FLOOR PLAN SCALE: 1/8" = 1'-0" DRAWING TITLE S ELECTRIC LIGHTING MEZZANINE FLOOR PLAN E2.1 CODED NOTES: # 1. NO WORK TO BE PERFORMED IN THIS AREA. 2. EXISTING TO REMAIN. 3. EXTEND EXISTING BRANCH CIRCUITING TO NEW TERMINAL UNIT. O 5/29/2015 4:03:44 PM Xavier University 1624 Herald Avenue Cincinnati, OH 45207 L:\ACAD\PROJECTS\MOTZ\XAVIER UNIVERSITY\XU.2014.06 (STUDENT ATHLETE ACADEMIC SUPPORT SERVICES)\E-3.1.DWG XU Cintas Center SAASS Interior Renovation A THIS DRAWING AND THE DESIGN CONCEPTS REPRESENTED, AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF MICHAEL SCHUSTER ASSOCIATES INC., AND MAY NOT BE USED, REPRODUCED, OR COPIED IN WHOLE OR PART, FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION OF MICHAEL SCHUSTER ASSOCIATES INC. Copyright Michael Schuster Associates, Inc. dba MSA Architects All Rights Reserved MSA Sport is a division of MSA Architects DATE 06-12-15 NO. DATE 1 ISSUED FOR CONSTRUCTION REVISION 06-17-15 ADDENDUM 1 PROJECT NO. 15136.00 N W E FLOOR PLAN SCALE: 1/8" = 1'-0" DRAWING TITLE S ELECTRIC POWER MEZZANINE FLOOR PLAN E3.1 LEGEND 2D FIRE ALARM CONTROL PANEL 2 NOTIFICATION APPLIANCE EXTENDER PANEL REMOTE ANNUNCIATOR PANEL 1 MANUAL FIRE ALARM PULL STATION SMOKE DETECTOR 4D 48" AFF 2 2D W3 SD DUCT MOUNTED SMOKE DETECTOR CM ADDRESSABLE CONTROL MODULE IAM ADDRESSABLE INDICATING MODULE H WALL MOUNTED HORN/STROBE UNIT - NO RATING INDICATES 15cd O WALL MOUNTED STROBE UNIT - NO RATING INDICATES 15cd H 75cd 75cd 1 HS WALL MOUNTED HORN/STROBE UNIT - CANDELA RATING AS INDICATED WALL MOUNTED STROBE UNIT - CANDELA RATING AS INDICATED A CEILING MOUNTED HORN/STROBE UNIT - NO RATING INDICATES 15cd CEILING MOUNTED STROBE UNIT - NO RATING INDICATES 15cd HS 75cd CEILING MOUNTED HORN/STROBE UNIT - CANDELA RATING AS INDICATED CEILING MOUNTED STROBE UNIT - CANDELA RATING AS INDICATED 75cd TS TAMPER SWITCH FS FLOW SWITCH DH DOOR HOLD OPEN DEVICE JUNCTION BOX 1 CONDUIT - CONCEALED IN WALL OR ABOVE CEILING CONDUIT - EXPOSED D CONDUIT STUBBED UP 2 2D (ETHERNET) D (ANALOG PHONE) D (ISDN) CONDUIT STUBBED DOWN 1 W.P. DENOTES WEATHER PROOF W.G. DENOTES WIRE GUARD N.T.S. NOT TO SCALE A.F.F. ABOVE FINISHED FLOOR 1 CODED NOTES: # FLATSCREEN TV 127" AFF 2D 21 1. NO WORK TO BE PERFORMED IN THIS AREA. 2. EXISTING TO REMAIN. 1 FLATSCREEN TV 127" AFF 2D 20 1 FLATSCREEN TV TYP. 2 93" AND 127" AFF 2D FLATSCREEN TV TYP. 2 93" AND 127" AFF 2D 19 5/29/2015 4:03:44 PM L:\ACAD\PROJECTS\MOTZ\XAVIER UNIVERSITY\XU.2014.06 (STUDENT ATHLETE ACADEMIC SUPPORT SERVICES)\E-4.1.DWG 4D 1 4D 25 1 Xavier University 1624 Herald Avenue Cincinnati, OH 45207 22 XU Cintas Center SAASS Interior Renovation CONDUIT - CONCEALED IN FLOOR 1 THIS DRAWING AND THE DESIGN CONCEPTS REPRESENTED, AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF MICHAEL SCHUSTER ASSOCIATES INC., AND MAY NOT BE USED, REPRODUCED, OR COPIED IN WHOLE OR PART, FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION OF MICHAEL SCHUSTER ASSOCIATES INC. Copyright Michael Schuster Associates, Inc. dba MSA Architects All Rights Reserved MSA Sport is a division of MSA Architects W2 1 18 DATE REMOVE EXISTING HORN STROBE AND REPLACE WITH NEW. 06-12-15 ISSUED FOR CONSTRUCTION 2D HS 2D RELOCATED HS 1 RELOCATE W1 NO. DATE D D D D D D D D D D D 1 D REVISION 06-17-15 ADDENDUM 1 RELOCATE RELOCATED 4D D 17 1 D D D LED FLATSCREEN 55" AFF D D PROJECT NO. 15136.00 N 16 FLOOR PLAN SCALE: 1/8" = 1'-0" W DRAWING TITLE E 4D S ELECTRIC SYSTEMS MEZZANINE FLOOR PLAN E4.1 O EXISTING PANEL No. RP-HA (SECTION 2) C/B ACC CONV RECEPT PHASE 1 AMP 20 POLE 1 NO 1 CONV RECEPT PHASE 1 20 1 3 WINDOW SHADES 1 20 1 20 1 7 CEILING PROJECTOR 20 1 9 STUDY 121 RECEPT 20 1 11 CONFERENCE 109 RECEPT 20 1 13 CONV RECEPT PHASE 1 20 1 15 CLASSROOM RECEPTS 20 1 17 CLASSROOM RECEPTS 20 1 19 CARD READER / DOOR ACCESS 20 1 21 20 1 AMPERE A 0.0 0.0 B 20 1 25 RADIO BROADCAST CENTER POWER 20 1 27 RADIO BROADCAST CENTER POWER 20 1 29 PODIUM POWER 20 1 31 CONV RECEPT PHASE 1 20 1 33 CONV RECEPT PHASE 1 20 1 35 OLD 29 (ICE MACHINE) 20 1 37 STUDY ROOM RECEPTS 20 1 39 STUDY ROOM RECEPTS 20 1 41 C NO C/B AMP 20 2 3.0 8.0 2.5 8 0.0 0.0 6 20 1 VENDING MACHINE 20 12 20 14 0.0 0.0 16 6.0 0.0 6.0 0.0 20 20 18 20 0.5 0.0 5.0 0.0 0.0 0.0 20 7.5 0.0 0.0 0.0 PREFUNCTION 112 TV RECEPT/WALL GRAPH. 1 20 20 20 36 20 20 40 4.5 0.0 42 20 20 1 WINDOW SHADES 20 1 45 WINDOW SHADES 20 1 47 PODIUM POWER 20 1 49 PODIUM POWER 20 1 51 PODIUM POWER 20 1 53 1 55 1 57 FVE-2 *40/2P CLASSROOM RECEPTS 20 1 59 CLASSROOM RECEPTS 20 1 61 1 - 20 1 63 OFFICE 106/107 RECEPT 1 - 20 1 65 - 20 1 67 - 20 1 69 CEILING PROJECTORS 20 1 71 CEILING PROJECTORS 20 1 73 CEILING PROJECTORS 20 1 75 CLASSROOM RECEPTS 20 1 77 CLASSROOM RECEPTS 20 1 79 MEZZ RECEPT DESK 20 1 81 BEHIND WALL TV 20 1 83 CONV RECEPT PHASE 1 1 1 1 AV POWER DINING OFFICE 1 - 1 1 ACC MAINS : 225 AMP M.L.O. 25% OF CONTINUOUS LOAD - - - VOLTAGE RATING : 208Y/120V, 3PH, 4W NON-CONTINUOUS LOAD - - - SHORT CIRCUIT RATING : 10,000 AMPS AIC 1.0 1.0 1.0 PANEL MOUNTING : SURFACE DERATED NON-CONTINUOUS LOAD - - - FEEDER SIZE : - TOTAL NEC LOAD - - - FEEDER O/C DEVICE : - TERM BOX CVB19-6 AMP 15/3P POLE 1 NO 1 1 3 1 TERM BOX CVB24-6 TERM BOX CVB18-6 TERM BOX QUAD D EVENT 30 15/3P 20 7 1 9 13 1 15 L:\ACAD\PROJECTS\MOTZ\XAVIER UNIVERSITY\XU.2014.06 (STUDENT ATHLETE ACADEMIC SUPPORT SERVICES)\E-5.1.DWG 5/29/2015 4:03:44 PM - CLASSROOM LIGHTING 20/3P 20 19 1 21 1 20 1 25 CLASSROOM LIGHTING 20 1 27 LIGHTING DINING CLASSROOM LIGHTING LIGHTING QUAD D EVENT 20 20 20 1 1 1 0.0 0.0 0.0 0.0 LIGHTING QUAD D EVENT 20 1 35 LIGHTING QUAD C/D EVENT 20 1 37 LIGHTING 01C01 20 1 39 COMMON AREA LIGHTS 20 1 41 15/3P 0.0 0.0 0.0 0.0 15/3P 8.9 0.0 8.9 0.0 15/3P 4.5 0.0 8.9 0.0 0.0 0.0 0.0 0.0 0.0 0.0 15/3P 1 1 1 1 15/3P 1 32 1 20/3P 36 40 42 1 4-WELL CO/D PAN 46 20 1 PROJECTION SCREENS 48 20 1 PROJECTION SCREENS 50 20 1 PROJECTION SCREENS 52 20 1 CLASSROOM RECEPTS 54 20 1 CLASSROOM RECEPTS 56 20 1 CONV RECEPTS 58 20 1 - 60 20 1 - 20/3P 1 TOASTER 68 20 1 CONV RECEPT PHASE 1 70 20 1 CONV RECEPT PHASE 1 64 0.0 0.0 0.0 0.0 0.0 0.0 8.0 0.0 8.0 0.0 66 72 20/2P 6.0 0.0 6.0 0.0 0.0 0.0 AV POWER DINING OFFICE 1 74 8.0 0.0 1 76 20 1 AV POWER DINING OFFICE 78 20 1 - 80 20 1 - 82 20 1 - 0.0 0.0 84 20 1 225 AMP M.L.O. 25% OF CONTINUOUS LOAD - - - VOLTAGE RATING : 208Y/120V, 3PH, 4W NON-CONTINUOUS LOAD - - - SHORT CIRCUIT RATING : 10,000 AMPS AIC 1.0 1.0 1.0 PANEL MOUNTING : SURFACE DERATED NON-CONTINUOUS LOAD - - - FEEDER SIZE : - TOTAL NEC LOAD - - - FEEDER O/C DEVICE : - DEMAND FACTOR CIRCUIT DESCRIPTION CIRCUIT DESCRIPTION ACC C/B ACC TERM BOX B6A-6 TERM BOX B6B-6 TERM BOX B7A-6 TERM BOX B7B-6 1 TERM BOX B8A-6 TERM BOX B8B-6 CCT AMP POLE 1 NO 1 1 3 - 20/3P 1 5 1 7 1 9 AMPERE A 0.0 0.0 B - 100/3P 1 11 1 13 1 15 TRANSFORMER RPHA 90/3P 1 17 CIRCULATION LIGHTS 20 1 19 GRAPHIC LIGHTS 20 1 21 PREFUNCTION LIGHTS 20 1 23 PREFUNCTION STRIP LIGHTING 20 1 25 - 20 1 27 - 20 1 29 - 20 1 31 - 20 1 33 - 20 1 35 - 20 1 37 20 20 20 1 1 1 TERM BOXES MISC - 20 1 39 - 20 1 41 - MAINS : 400 AMP M.L.O. 25% OF CONTINUOUS LOAD - - - VOLTAGE RATING : 480V, 3PH, 3W NON-CONTINUOUS LOAD - - - SHORT CIRCUIT RATING : 22,000 AMPS AIC 1.0 1.0 1.0 PANEL MOUNTING : SURFACE NO C/B AMP 2 4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 5.4 0.0 0.1 0.0 2.2 0.0 10.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 50/3P 1 8 1 20/3P 1 12 1 14 1 100/3P 1 18 1 20 1 22 CIRCUIT DESCRIPTION ACC 1 1 16 0.0 0.0 POLE 6 10 0.0 0.0 LIGHTING QUAD D EVENT - C 0.0 0.0 EC-1 01D03, 4, 10, 12 - CCT 0.0 0.0 1 SUBTOTAL : CONTINUOUS LOAD DEMAND FACTOR 20 MAINS : 1 1 6.9 0.0 44 62 0.0 0.0 1 38 0.0 0.0 POLE 30 34 ACC - 1 24 28 6.0 0.0 1 26 8.9 0.0 POLE - 1 18 22 6.0 0.0 1 20 0.0 0.0 AMP - 1 12 16 25.9 6.0 1 14 0.0 0.0 NO SUBTOTAL : CONTINUOUS LOAD 1 6 10 0.0 0.0 33 AMP 8 0.0 0.0 29 31 4 0.0 0.0 23 CLASSROOM LIGHTING NO C/B 2 17 1 C CIRCUIT DESCRIPTION EXISTING PANEL No. LP-H (SECTION 2) CCT 0.0 0.0 11 1 1 B 5 1 1 A 0.0 0.0 25.9 6.0 - - AMPERE 7.5 6.0 - - CCT 7.5 6.0 TV POWER DINING HALL 1 C/B A 7.5 5.0 AV POWER DINING OFFICE 1 C 1.5 5.0 RADIO BROADCAST CENTER POWER - C/B B CCT 1.5 5.0 CONV RECEPT PHASE 1 EXISTING PANEL No. LP-H (SECTION 1) CIRCUIT DESCRIPTION A 1.5 0.0 RECEPTION 102 RECEPT SUBTOTAL : CONTINUOUS LOAD DEMAND FACTOR NO 43 RECEPTION 102 RECEPT COMPUTER ROOM 108 RECEPT 38 4.5 0.0 1 1 30 POLE 1 ITEM B2 20 34 0.0 0.0 1 24 20 AMP 20 AMPERE STUDY 120 RECEPT COMPUTER ROOM 108 RECEPT 32 0.0 0.0 1 1 20 WINDOW SHADES VENDING MACHINE 20 28 0.0 0.0 1 22 26 0.0 0.0 CCT ITEM D23 1 ITEM D24 20 C/B ACC 1 20 CIRCUIT DESCRIPTION ACC 20 10 0.0 0.0 POLE CIRCUIT DESCRIPTION 4 8 4.0 0.0 23 RADIO BROADCAST CENTER POWER CCT 0.0 0.0 5 PROJECTOR SCREEN SVN-1 1 CCT 100/3P 24 1 - - TRANSFORMER RPHC - 1 26 20 1 - 28 20 1 - 30 20 1 - 32 20 1 - 34 20 1 - 36 20 1 - 38 20 1 - 40 20 1 - 0.0 0.0 42 20 1 - SUBTOTAL : CONTINUOUS LOAD - - - MAINS : 400 AMP M.L.O. 25% OF CONTINUOUS LOAD - - - VOLTAGE RATING : 480V, 3PH, 3W NON-CONTINUOUS LOAD - - - SHORT CIRCUIT RATING : 22,000 AMPS AIC 1.0 1.0 1.0 PANEL MOUNTING : SURFACE DEMAND FACTOR THIS DRAWING AND THE DESIGN CONCEPTS REPRESENTED, AS INSTRUMENTS OF SERVICE, ARE THE SOLE PROPERTY OF MICHAEL SCHUSTER ASSOCIATES INC., AND MAY NOT BE USED, REPRODUCED, OR COPIED IN WHOLE OR PART, FOR ANY PURPOSE WITHOUT PRIOR WRITTEN AUTHORIZATION OF MICHAEL SCHUSTER ASSOCIATES INC. Copyright Michael Schuster Associates, Inc. dba MSA Architects All Rights Reserved MSA Sport is a division of MSA Architects DATE 06-12-15 NO. DATE 1 DERATED NON-CONTINUOUS LOAD - - - FEEDER SIZE : - DERATED NON-CONTINUOUS LOAD - - - FEEDER SIZE : - TOTAL NEC LOAD - - - FEEDER O/C DEVICE : - TOTAL NEC LOAD - - - FEEDER O/C DEVICE : - Xavier University 1624 Herald Avenue Cincinnati, OH 45207 CIRCUIT DESCRIPTION XU Cintas Center SAASS Interior Renovation EXISTING PANEL No. RP-HA (SECTION 1) ISSUED FOR CONSTRUCTION REVISION 06-17-15 ADDENDUM 1 PROJECT NO. 15136.00 DRAWING TITLE ELECTRIC DETAILS E5.2