Installation Instructions EcoMeter Operation Load 1 EcoMeter LED OFF ON ON OFF Specifications Light Level Sensing:0to200foot-candles Operating Environment: • Temperature:32°F–104°F(0°C–40°C) • RelativeHumidity:20%to90%Non-condensing Housing:Durable,injectionmoldedhousing. PolycarbonateresincomplieswithUL94VO. Size: • MountingPlate/StrapDimensions: 4.195"Hx1.732"W(106.553mmx44mm) • ProductHousingDimensions:2.618"Hx1.752" Wx1.9"D(66.5mmx44.5mmx48.26mm) LED Indicators:RedLEDindicatesPIRdetection; GreenLEDactsasEcoMeterornightlightlocator. EcoMeter OFF Theareaisvacatedandthe lightsturnOFFautomatically ON Increasedawarenessofenergysavings; Actsasanightlightlocator ApersonturnsthelightsOFF manuallyuponexitinganarea ON Increasedawarenessofenergysavingsand remindsindividualstotakecontroloftheir lightingforadditionalsavings;Actsasanight lightlocator Thedaylightfeatureprevents thelightsfromautomatically turningONwhenaperson entersanarea ON Increasedawarenessofenergysavingsand letsindividualknowthatthedaylighting featureisworking TheONW-P-1001-SPOccupancySensingWallSwitchisaPassiveInfrared(PIR)motionsensinglightingcontrol andconventionalWallSwitchall-in-one,usedforenergysavingsandconvenience. Installation TheONW-P-1001-SPcanbeinstalledinanystandardsinglegangbox. ItmaybeinstalledinthesamemannerasanordinaryWallSwitch. • WiretheONW-P-1001-SPasdescribedinthewiringsection. • MounttheONW-P-1001-SPinthejunctionbox. Wiring CAUTION: Before installing or performing any service on a Greengate system, the power MUST be turned OFF at the branch circuit breaker. According to NEC 240-83(d), if the branch circuit breaker is used as the main switch for a fluorescent lighting circuit, the circuit breaker should be marked “SWD.” All installations should be in compliance with the National Electric Code and all state and local codes. NOTE REGARDING COMPACT FLUORESCENT LAMPS: The life of some compact fluorescent lamps (CFLs) is shortened by frequent automatic or manual switching. Check with CFL and ballast manufacturer to determine the effects of cycling. Coverage TheONW-P-1001-SPisdesignedforofficesupto300squarefeet. 36 Description Benefit ONW-P-1001-SP-W ONW-P-1001-SP-V ONW-P-1001-SP-LA ONW-P-1001-SP-G ONW-P-1001-SP-B , , 20 Minor Motion, IR Major Motion, IR PIR Technology Thesensor’ssegmentedlensdividesthefieldofviewintosensorzones,anddetectsthechangesintemperature thatarecreatedwhenaperson,orpartofapersonassmallasahand,passesintooroutofasensorzone. , 8 TheONW-P-1001-SPallowsthecontrolofoneGreengateswitchpackorinputtoaGreengatePanel. Thesensormaybeinterfacedtoanenergymanagementsystemthatacceptseitheranormallyopenornormally closeddrycontactviathesensor’sFormCrelay. ThesensorcanbeconfiguredtoenhanceenergysavingsbysettingtheunitformanualONoperation. InAutomaticONMode,thelightsturnONautomaticallywhenapersonenterstheroom.InManualONMode,the lightsareturnedONbypressingtheuniversallyrecognizedlighticonPushbutton.Ineithermode,thelightsstayON aslongasthesensordetectsmotionintheroom.Whentheroomisvacated,thelightsturnOFFautomaticallyafter apresetTimeDelayinterval. Maximum coverage area may Thesensorincludesself-adaptivetechnologythatcontinuallyadjuststoconditionsbyadjustingsensitivityand vary somewhat according to room TimeDelayinReal-time.ByadjustingsensitivityandTimeDelayautomatically,thesensorismaximizingthepotential shape and the presence of obstacles. energysavingsthatareavailableintheparticularapplication. TheEcoMeterprovidesavisualindicatorofenergyusage,increasingenduserawarenessandreminding individualstotakecontroloftheirlightingtomaximizeenergysavings. TheDaylightingfeaturepreventslightsfromturningON,whentheroomisadequatelyilluminatedbynaturallight. Walk-ThroughfeaturemaximizesenergysavingsbynotleavingthelightsONafteramomentaryoccupancy.The Location sensorwillswitchthelightsONwhenitdetectsapersonenteringthearea.Ifthesensordoesnotcontinuetodetect WheninstallingtheONW-P-1001-SPinanewjunctionbox,choosetheswitchlocationcarefullytoprovide motion20secondsfollowingtheinitialactivation,itwillautomaticallygotoashorter2minuteTimeDelay. optimumcoverageoftheoccupiedarea.WhenreplacinganexistingWallSwitch,bearinmindthattheremustbea TrackingModeallowstheloadconnectedtotheFormCrelaytofollowthestateofthesensor’sbluelead. HVACModeallowstheloadconnectedtotheFormCrelaytoremainONwhenthelightsareturnedOFFmanually. clearLine-of-sightbetweenthesensorandtheareatobecovered.AvoidpointingtheONW-P-1001-SPdirectlyinto thehallwaywhereitmaydetectpassers-by. ApplicationsmayincludekeepingtheroomatadesiredtemperaturewhilegivingapresentationandthelightsareOFF. 1.MakesurepoweristurnedOFFatthebranchcircuitbreaker. 2.Wireunitsasshowninwiringdiagramsperapplicablevoltagerequirements. 3.MountunittoWallBox. 4.TurnpowerbackONatthebranchcircuitbreakerandwait2minutesfortheunittostabilize. 5.Makenecessaryadjustments.(SeeCheckoutandAdjustmentssection) 6.InstallWallSwitchplate. Wiring Diagram 1 HOT LINE NEUTRAL WHITE Technology:PassiveInfrared(PIR) Electrical Ratings: Input: • 10-30VDCfromGreengateSwitchpackor GreengateSystem.Maximumcurrentneededis 25mApersensor. Output: • OpencollectorouputtoswitchuptotenGreengate Switchpacks. • IsolatedFormCRelay • IsolatedFormCRelayRatings:1A30VDC/VAC Time Delays:Self-Adjusting,15seconds/test(10min Auto),Selectable5,15,30minutes Coverage:Majormotion–1000sq.ft. Minormotion–300sq.ft. Action Apersonentersthespaceand theloadisactivated HOT • ForusewithGreengateSwitchpacks&Systems Only.Forusewithothersystems,contact TechnicalSupport • DonotrunanyGreengateLowVoltagewiringinthe sameconduitaspowerconductors # # # # # LOAD BLUE BLUE ORANGE (N.O.) RED (10-30VDC) GRAY (COMMON) BLUE (CONTROL) PURPLE (N.C.) BLACK (COMMON) BLACK • Readallinstructionsonbothsidesofthissheetfirst • InstallinaccordancewithALLlocalcodes • Forindooruseonly BLUE General Information Model Model Model Model Model RED P/N 9850-000350-01 NeoSwitch Passive Infrared (PIR) Technology Low Voltage Occupancy Sensing Wall Switch CAUTION: If a room is wired for two circuits using two separate hot leads, it is very important to connect only one circuit per relay. Both circuits must be fed from the same phase. Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, Georgia 30269 www.coopercontrol.com DIP Switch Settings DIP Switch Legend Time Delay DIP Switch Activation Isolated Relay PIR Sensitivity Walk-Through Mode Override EcoMeter Relay 1 1 2 Auto* 5 Minutes Auto Tracking Full Disable Enable Disable Manual HVAC 50% Enable Disable Enable 15 Minutes 30 Minutes *Self-Adjusts to 10 min. user mode 3 4 6 5 7 8 Default = 1 2 3 4 5 6 7 8 Checkout and Adjustment AdjustmentsshouldbemadewiththeHVACsystemonsothattheinstallerwillbeabletodetecttheeffectof airflowontheoperationoftheONW-P-1001-SP.Useonlyinsulatedtoolstomakeadjustments. Immediatelyafterapplyingpowertothe lightingcircuit,waitapproximatelytwominutes fortheswitchtopowerupandstabilize. Red (PIR) Self-Adjust Detection LEDs Sensorisshippedinself-adjustmode.This PIR Lens appliestoTimeDelayandPIRsensitivity.In Daylight preparationfortheInstallerTest,theTime Sensor Level Delayissetto15seconds,afterthesensoris Adjustment installed,poweredONandhasstabilized,the unitwillTime-out15secondsafterthelast DIP Switches motiondetected.Coverageandsensitivity canbeconfirmedbywatchingtheRed(PIR) indicatorLEDonthefrontofthesensor,while movingaroundtheroom. 1.WalkaroundtheroomandmonitorLEDs. 2.Standindifferentpartsoftheroom ON/OFF Button andwaveyourhands.LEDshouldonly turnONforonesecondwitheachmotion.(IfLEDdoesnotturnON,gotoInstallerAdjustments–Sensitivity AdjustmentSection) 3.Standstillthreetofourfeetawayfromsensorforfiveseconds.LEDshouldnotturnON.(IfLEDturnsON,goto InstallerAdjustments–SensitivityAdjustmentssection) 4.Walkoutsidetheroomandwait15secondsforthelightstoturnOFF.(IflightsdonotturnOFFgotoInstaller AdjustmentsSection) 5.Re-entertheroomtoactivatesensor.(IflightsdonotturnONgotoTroubleshootingSection) 6.Atthispointyoucanexittheroomandletthesensortime-out.WhenthesensorTimes-outandisOFFforfive minutes,theunitwillgotoa10minuteTimeDelayusermodesetting. Daylight Adjustments ThedaylightingfeaturepreventsthelightsfromturningONwhenthe roomisadequatelyilluminatedbynaturallight.Ifthereisenoughlightin theroomregardlessofoccupancy,thesensorwillholdthelightsOFF.If thereisnotenoughlightintheroom,thesensorwillallowthelightsto turnONwhenoccupied.Thesensorwillnotallowthedaylightingfeature toturntheloadOFFuntilthespaceisvacantorthelightlevelrisesabove thesetpointandtheTimeDelayexpires.WhileinManualActivationMode, ifsomeoneattemptstoturntheloadONandthereissufficientdaylight availabletheDaylightingfeaturewillholdthelightsOFF. 1.Setthelightlevelwhentheambientlightisatthelevelwhereno artificiallightisneeded.Ifthisfeatureisnotneeded,leavethelight levelatmaximum(fullyCW). 2.Withtheload(s)ON,putthesensorintoTestMode.Toplaceinto TestMode,toggleDIPSwitch8outofitscurrentposition,wait3 secondsandthenbackintoitsoriginalposition. 3.SettheLightleveltominimum(fullyCCW). 4.LetthesensorTime-outsolightsareOFF.EnterthespaceandlightsshouldremainOFF. 5.MakesurenottoblockthesensorfromthedaylightsourceandadjustthelightlevelpotentiometerCWinsmall increments.(Pause5secondsbetweeneachadjustment) 6.LightswillnotturnONuponoccupancyactivation,whenthe ambientlightlevelexceedsthedaylightthresholdsetting. Time Delay Adjustments Peoplewhoremainverystillforlongperiodsoftimemayneed alongerTimeDelaythanthedefaultsettingof10minutes.As 1 2 3 4 5 6 7 8 DIP Switches longastheself-adjustingfeatureisenabled,theswitchwill 1&2 respondtoeachpairofFalse-offswithnonormalOFFinbetween, byalternatelymakingslightadjustmentstoeitherTimeDelay(by 2minuteincrements)orsensitivity,sothereshouldbenoneed formanualadjustment.Ifmanualadjustmentisdesired,referto TimeDelaysettingsinDIPSwitchlegend. ResetsensorTimeDelaytofactorysettingsbymovingDIPSwitches1and2down.(IfDIPSwitches1and2are alreadydown,toggleDIPSwitch1outofitscurrentposition,wait3seconds,andthenbacktoitsoriginalposition) Tracking/HVAC WhentheoccupancysensorturnsthelightsONorOFFeitherbydetectionoramanualpress,thelightscanbeturned OFFmanuallybypressingthePushbutton.ThelightswillremainOFFaslongasthereismotionintheroom,oncethe occupancysensornolongerdetectsmotionandtheTimeDelayexpires,thesensorwillrevertbacktoitsnormal operation. TrackingMode–Isolatedrelaywillfollowoperationofsensorinallmodes.Relaystatewillchangewhenoccupancy sensorisactivatedand/orturnedONorOFFmanually. HVACMode–IsolatedrelaywillonlychangestateinAuto/ManualONandAutoOFFmodes.Thestatewillnot change,iftheoccupancysensoristurnedOFFmanually.TherelaywillchangestateoncetheTimeDelayexpires. Override Theoverridesettingallowsthesensortooperateasaserviceswitchintheunlikelyeventoffailure. 1.MoveDIPSwitch8up. 2.ThePushbuttoncanbeusedtomanuallyturnlightsONorOFF. Troubleshooting Issue Possible Causes Suggestions SensorisinManualONmode PressPushbutton.IfAutoMode isdesiredchangeActivationModetoAuto. SensorwasturnedOFFmanually.IftheSensor wasturnedOFFmanuallybeforetheTimeDelay Lights Will Not expired,lightswillremainOFFfortheremainder Turn ON oftheTimeDelay. automatically Lights Will Not Turn ON manually CheckEcoMeterLED.IfLEDisONthisis anindicationthatthelightswereturnedOFFmanually. PressthePushbuttontoturnthelightsbackON. DaylightFeatureEnabled IfalllightsarerequiredtoturnON adjustdaylightpotentiometer. Powerinterruption Checkincomingvoltageand/orwiring. DaylightFeatureEnabled IfalllightsarerequiredtoturnON adjustdaylightpotentiometer. Powerinterruption Checkincomingvoltageand/orwiring. If lights will still not turn ON, set sensor to override mode and call Technical Services at 1-800-553-3879 Override MakesuresensorisnotinOverrideMode(DIPSwitch8up). Self-Adjust IfsensorisinSelf-AdjustMode,itmaybepossibleforthe unittohaveincreasedtheTimeDelaytoa30minutedelay. IfthelightsdonotturnOFFafter30minutesfollownextstep. 30MinuteDelay MaximumTimeDelayis30Minutes.CheckDIPSwitches toverifyDIPSwitchsettings.IflightsdonotturnOFFatthe setTimeDelay,checknextstep. PIRactivatedbyheatsourceotherthanoccupant MoveDIPSwitch5up. Lights Will Not Turn OFF automatically Lights Will Not Turn OFF manually CallTechnicalServices If lights will still not turn OFF, call Technical Services at 1-800-553-3879 Warranties and Limitation of Liability Pleaserefertowww.coopercontrol.comundertheLegalsectionforourtermsandconditions. Note:ToplaceintoTestMode,toggleDIPSwitch8outofitscurrentposition,wait3seconds,andthenbackintoitsoriginalposition. Installer Adjustments PIR Sensitivity 1.Standindifferentareasoftheroomandwaveyourhands. 2 IftheRedLEDdoesnotturnON,checkforanyobstructions. 3 Standstillthreetofourfeetawayfromsensorforfiveseconds.LEDshouldnotturnON. 4 IfRedLEDturnsONwithoutmotionorisconstantlyONadjustPIRsensitivityto50%bymovingDIPSwitch5up. Field-of-view outside the space 1. AdjustPIRsensitivityto50%bymovingDIPSwitch5up. 2. Usenon-reflectivetapestripstocovertheportionsofthesensorlensthatviewoutsidethespace. Printed in Malaysia Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, Georgia 30269 www.coopercontrol.com