HALO® INSTALLATION INSTRUCTIONS FOR L2004 POWER SUPPLY WARNING Avoid Fire or Electric Shock • Follow installation instructions carefully. • If unsure about electrical installation consult a qualified electrician. SAFETY INFORMATION IMPORTANT SAFETY INSTRUCTIONS. READ CAREFULLY FOR YOUR PROTECTION AND SAVE ALL INSTRUCTIONS. • • • • • • • • Disconnect power before installing power supply on track. Wear rubber-soled shoes and work on a sturdy wooden ladder. This power supply must be installed according to the National Electrical Code and local building codes. To avoid a hazard to children, account for all parts and destroy all packing materials. If you are unsure about the installation or use of this power supply consult a qualified electrician. CAUTION: To reduce the risk of fire and electrical shock, use only fixtures and fittings intended for use with Halo and Lazer by Halo track systems only. This device is not suitable for use with L963 Four-Circuit Track Adapter, L973 Canopy Adapter, L918 Series Extension Wands, L917 Slope Adapter, L972 C-Clamp Adapter, 477 Trac Adapter Trim, L967 Lampholder Adapter with Switch, L968 Lampholder Adapter with Dimmer Switch, LZR209 and LZR210 Monopoints. This device should not be used with wedge base lamp holders, LV301 and LV302 LOW VOLTAGE CAUTIONS Applications Low voltage electronic power supplies should not be installed in such a manor as to entrap excessive ambient heat around the power supply such as enclosed display windows, showcases, alcoves, recessed covers, etc. Consult a qualified lighting designer if uncertain of the suitability for a given application. Dimming Dimming quartz halogen lamps may reduce life and emit sound. Low voltage electronic power supplies require proper dimming equipment. An improper dimmer may cause damage to the power supply and shorten lamp life. Using this device on more than one dimmer circuit may produce interference between dimmer circuits. A magnetic inductor (choke) is recommended to reduce this condition in the dimmed mode. Consult the dimmer manufacturer for dimmer equipment recommendations. Operation This device is designed to adapt Linea LV300 series low voltage fixture fittings to Halo and Lazer by Halo line voltage track. It converts the 120V 60HZ input to 12V 50W maximum. This device is overload and short circuit protected. In the event of an overload or short circuit, the power supply will shut down and periodically attempt to restart. In the event of a shut down, clear the overload or short circuit and restart the power supply. Please note the power supply has a soft start feature designed to extend the life of the lamp and reduce in-rush current. Slow lamp turn on is normal operation. NOTICE: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A RADIO FREQUENCY LIGHTING DEVICE PURSUANT TO PART 18 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE WITH ELECTRONIC DEVICES SUCH AS: RADIOS, TELEVISIONS, WIRELESS TELEPHONES OR REMOTE CONTROLS. IF INTERFERENCE OCCURS IT MAY BE POSSIBLE TO CORRECT THE INTERFERENCE BY ONE OR MORE OF THE FOLLOWING MEASURES: • • • REORIENT OR RELOCATE ANTENNA OF THE RECEIVING DEVICE. INCREASE THE SEPARATION BETWEEN THIS EQUIPMENT AND THE DEVICE. CONNECT THIS EQUIPMENT OR THE DEVICE INTO A DIFFERENT OUTLET OR CIRCUIT. THIS EQUIPMENT SHOULD NOT BE USED: • CLOSER THAN THREE (3) FEET FROM ANY SENSITIVE ELECTRONIC EQUIPMENT. • NEAR MARITIME SAFETY, NAVIGATION, OR COMMUNICATIONS EQUIPMENT OPERATING BETWEEN 0.45 MHz AND 30 MHz. Service There are no user serviceable parts inside. Opening unit will void warranty. Contact point of purchase for service. Customer First Center • 1121 Highway 74 South•Peachtree City, GA 30269 • 770.486.4800 • Fax 770.486.4801 702311 HALO® Assembly FIG 1 To install the LInea LV300 series fixture fitting to the power supply, align the fixture fitting adapter as shown, insert into the mating slot while holding the outside collar down and turn 90° allowing the tabs on the collar to lock the fixture adapter to the power supply. Please refer to the instruction sheet provided with the fixture fitting for additional installation information (Fig. 2). Installation The L2004 power supply can be used with Halo and Lazer by Halo single circuit track and Halo-2 two circuit track. An adjustable contact allows you to select the circuit position. Use a narrow blade screwdriver as shown to adjust the contact. Lift or lower the contact until it touches the upper or lower plastic stop of the contact assembly (Fig. 3). To use with Halo or Lazer by Halo single circuit track the adjustable contact must be in the circuit #1 or lower position. To use with Halo-2 two circuit track adjust the contact position to the desired circuit position, circuit #1 down or circuit #2 up position (Fig. 3). To install the power supply to the track, insert the contact assembly into the track and rotate the power supply 90° so the polarity line on the power supply aligns with the polarity line on the track. Pull back and release the thumb latch allowing the power supply to lock into position (Fig. 4). FIG 3 Circuit #2 (Up) To remove the power supply, slide thumb latch down until latch is clear of the track channel opening. Twist the power supply housing 90° until the contact assembly is free and remove power supply from track (Fig. 4) Circuit #1 (Down) FIG 1 Polarity Groove FIG 4 Polarity Groove Thumb Latch L2004 Adapter Track Customer First Center • 1121 Highway 74 South•Peachtree City, GA 30269 • 770.486.4800 • Fax 770.486.4801 702311