HALO Commercial

HALO Commercial
DESCRIPTION
Type
Catalog #
Recessed 6-inch LED shallow lens downlight is available in
various distributions, lumen and CRI/CCT options. Suitable for
shallow commercial construction and can be used for both new or
renovation work. Insulation must be kept 3” from top and sides of
housing. Use for general area lighting where high efficiency and
visual comfort are required.
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
MECHANICAL
Frame
Boat shaped galvanized steel
frame with adjustable plaster lip
accommodates ceilings up to
1/2” - 2” thick. May be used for
new construction or remodeling
installations. Provided with (2)
remodel clips to secure frame
when installed from below the
ceiling.
Mounting Brackets
Bar hanger receivers adjusts 2”
vertically from above the ceiling
or thru the aperture. Use with
No Fuss™ bar hangers or with
1/2” EMT. Removable to facilitate
installation from below the
ceiling.
No Fuss™ Bar Hangers
Captive preinstalled bar
hanger locks to tee grid with a
screwdriver or pliers. Centering
mechanism allows consistent
positioning of fixtures.
B e a m F o rm i n g O p t i c s
Optional beam forming optics
replace diffuse lens and provide
narrow flood or flood distribution
for long throws of light.
Compliance
- cULus listed for wet location
- cCSAus listed for wet location
Reflector
One piece parabolic aluminum
reflector combines high optical
efficiency with visual comfort.
Attaches to LED module with
(3) speed clamps minimizing
light leaks to lens. Self-flanged
standard with an optional white
painted flange.
-Certified for wet locations,
insulation must be kept 3” from
top and sides.
- IP66 Ingress Protection Rated
- Airtight per ASTM-E283.
PD612
PD618
- Optional City of Chicago
environmental air (CCEA)
marking for plenum
applications.
PDM6
- EMI/RFI emissions per FCC
Trim Retention
47CFR Part 18 non-consumer
Reflectors are retained with two
torsion springs holding the flange limits.
tightly to the finished ceiling
- Contains no mercury or lead
surface.
and RoHS compliant.
ELECTRICAL
- Photometric testing in
Junction Box
accordance with IES LM-79-08.
(6) 1/2” and (2) 3/4” trade size
- Lumen maintenance projections
pry outs positioned to allow
in accordance with IES LM-80-08
straight conduit runs. Listed for
and TM-21-11.
(12) #12 AWG (six in, six out) 90°C
conductors and feed thru branch - Can be used to comply
OPTICAL
LED Module
wiring.
with California Title 24 NonProximity phosphors over chip
Residential Lighting Controls
Driver
on board LEDs provide a uniform
requirements as a LED
Integral UNV 120 - 277V 50/60 Hz
source with high efficiency and
Luminaire.
constant current driver provides
no pixilation. Available in 80 or 90
noise free operation. For 347V
- ENERGY STAR® listed for
CRI minimum, accuracy within 3
input use Halo transformer
commercial applications,
SDCM provides color uniformity.
H347 or H347200. Continuous,
reference database for current
See ordering information for
flicker-free dimming from 100%
listings.
available CRI / CCT options.
to 10% with leading or trailing
Passive thermal management
edge phase cut at 120V or 0 -10V
achieves L70 at 50,000 hours
analog control.
in non IC applications. Integral
Emergency Option
diffuse lens provides visual
Provides 90 minutes of standby
shielding. Integral connector
lighting meeting most life
allows quick connection to
safety codes for egress lighting.
housing flex.
Available with remote charge
indicator and test switch.
64V
1,200 & 1,800
Lumen Series
LED
6-Inch Aperture
Shallow Lens
Downlight
Lumens
1200 Series
Input Voltage
120V
277V
Input Current
0.19A
0.1A
Input Power
Efficiency
Inrush Current
Lumens
23 W
23.2 W
79 LpW
78 LpW
2.14A
4.1A
1800 Series
Input Voltage
120V
277V
Input Current
0.24A
0.12A
Input Power
29.5 W
29.4 W
Efficiency
75 LpW
75 LpW
2.88A
6.94A
Inrush Current
THD: ≤ 20%
PF: ≥ 0.90
T Ambient -30 - +40°C
Sound Rating ≤ 22dba
AHC131423
9/17/2014
HALO Commercial
PD612/PD618
PDM6
64V
OR DERING INFORMATI O N
SAMPLE NUMBER: PD612ED010REM-PDM6827-64VC
A complete luminaire consists of a housing, LED module and reflector, order separately.
Housing
Lumens
Driver
Options
PD6 = 6" aperture LED downlight
PD6CP = 6" aperture LED
downlight, CCEA listed
for City of Chicago
plenum requirements
12 = 1,200 lumens (nominal)
18 = 1,800 lumens (nominal)
ED010 = 120-277V
50/60Hz, 0-10V
and LE/TE phase
cut dimming
REM = Emergency
operation with
remote indicator
and test switch
(REM option not
available with
PD6CP housing),
60 Hz
LED Module
CRI/CCT
PDM6 = Downlight LED
module for PD6
housing, provides
1,200 or 1,800
lumens (nominal)
depending
on connected
housing type
827 = 80 CRI, 2700K CCT
927 = 90 CRI, 2700K CCT
830 = 80 CRI, 3000K CCT
930 = 90 CRI, 3000K CCT
835 = 80 CRI, 3500K CCT
935 = 90 CRI, 3500K CCT
840 = 80 CRI, 4000K CCT
940 = 90 CRI, 4000K CCT
Reflector
Finish Option
Flange Option
Accessories
64V = 6" shallow parabolic reflector
C = Specular clear
G = Specular gold
H = Semi-specular clear
W = White (white flange)
Blank = Polished flange standard with C, G, &
H reflector finishes
Blank = White flange standard with W
WF = White flange option available with C, G, &
H reflector finishes
HB128APK = L channel hanger bar, 26",
‘No-Fuss’, pair (replacement)
RMB22 = 22" long wood joist mounting
bars, pair
BFR56NFL = Beam forming reflector kit,
narrow flood distribution
BFR56FL = Beam forming reflector kit, flood
distribution
BFR56MH = Media holder, accepts one
3.45” lens
L345SF = 3.45” diameter soft focus lens
H347 = Step down transformer for 347V
input, 75VA max
H347200 = Step down transformer for 347V
input, 200VA max
D I ME NSIONS
5"
[127 mm]
7.5"
[190 mm]
6"
[155 mm] ID
7.25"
[184 mm]
7.75"
[197 mm] OD
13"
[333 mm]
26"
[671 mm]
5.1"
[130 mm]
13"
[339 mm]
7.5"
[190 mm]
6"
[155 mm] ID
7.25"
[184 mm]
7.75"
[197 mm] OD
26"
[671 mm]
13"
[333 mm]
HALO Commercial
PD612/PD618
PDM6
64V
C O MP L IANCE TABLE
1200 LUMEN
80 CRI
Catalog #
PD612ED010 - PDM6827
PD612ED010 - PDM6830
PD612ED010 - PDM6835
PD612ED010 - PDM6840
Lumens
LPW
Lumens
LPW
Lumens
LPW
Lumens
LPW
64VC
1654
72
1720
75
1780
77
1811
79
64VCWF
1649
72
1715
75
1775
77
1805
78
64VG
1628
71
1693
74
1752
76
1782
77
64VGWF
1612
70
1676
73
1734
75
1765
77
64VH
1606
70
1670
73
1728
75
1758
76
64VHWF
1596
69
1660
72
1717
75
1747
76
64VW
1648
72
1714
75
1774
77
1804
78
90 CRI
Catalog #
PD612ED010 - PDM6927
PD612ED010 - PDM6930
PD612ED010 - PDM6935
PD612ED010 - PDM6940
Lumens
LPW
Lumens
LPW
Lumens
LPW
Lumens
LPW
64VC
1283
56
1379
60
1493
65
1492
65
64VCWF
1279
56
1375
60
1488
65
1488
65
64VG
1263
55
1357
59
1469
64
1469
64
64VGWF
1251
54
1344
58
1455
63
1454
63
64VH
1246
54
1339
58
1449
63
1449
63
64VHWF
1238
54
1331
58
1440
63
1439
63
64VW
1279
56
1374
60
1488
65
1487
65
1800 LUMEN
80 CRI
Catalog #
PD618ED010 - PDM6827
PD618ED010 - PDM6830
PD618ED010 - PDM6835
PD618ED010 - PDM6840
Lumens
LPW
Lumens
LPW
Lumens
LPW
Lumens
LPW
64VC
2009
68
2096
71
2174
74
2213
75
64VCWF
2003
68
2089
71
2168
73
2206
75
64VG
1977
67
2062
70
2140
73
2178
74
64VGWF
1958
66
2042
69
2119
72
2156
73
64VH
1950
66
2034
69
2111
72
2148
73
64VHWF
1938
66
2022
69
2097
71
2135
72
64VW
2002
68
2088
71
2166
73
2205
75
90 CRI
Catalog #
PD618ED010 - PDM6927
PD618ED010 - PDM6930
PD618ED010 - PDM6935
PD618ED010 - PDM6940
Lumens
LPW
Lumens
LPW
Lumens
LPW
Lumens
LPW
64VC
1567
53
1684
57
1817
62
1841
62
64VCWF
1562
53
1678
57
1812
61
1835
62
64VG
1542
52
1657
56
1789
61
1812
61
64VGWF
1527
52
1641
56
1771
60
1794
61
64VH
1521
52
1634
55
1764
60
1787
61
64VHWF
1512
51
1624
55
1753
59
1776
60
64VW
1561
53
1677
57
1811
61
1834
62
ES, T24
ES = ENERGY STAR® Qualified
T24 = Can be used to comply with California Title 24 Non-Residential
HALO Commercial
PD612/PD618
PDM6
64V
P H O T OMETRY
PD612ED010- PDM6835-64VC
Candela Distribution
Spacing Criteria = 0.93
Lumens per Watt = 77.4 LpW
Test No. P114162
Test Model: PD612ED010- PDM6835-64VC
Candlepower Distribution
Eyeball at 0-degrees
90º
75º
450
60º
900
Degrees
Vertical
Candela
0*
1289
Luminance
Cone of Light Footcandles
(Average Candela/M2)
Degree
Avg. 0°
Luminance
Distance to
Illuminated
Plane
Initial Nadir
Footcandles
W
Width
5
1277
45
32383
5.5'
42.6
5
5
1122
55
19966
7'
26.3
6.4
6.4
25
864
65
6603
8'
20.1
7.4
7.4
35
608
75
0
9'
15.9
8.2
8.2
45
418
85
0
10'
12.9
9.2
9.2
55
209
12'
9
11
11
65
51
75
0
85
0
90
0
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss factors where necessary.
Zonal Lumen Summary
*CBCP
1350
15º
Length
15
45º
0º
Beam (ft.)
L
30º
Scaling factor for the Battery back up:
Zone
Lumens
% Fixture
0-30
829
46.6
0-40
1213
68.1
0-60
1721
96.7
0-90
1780
100
- 1800 Lumen = 0.33
- 1200 Lumen = 0.27
PD612ED010- PDM6930-64VC
Candela Distribution
Spacing Criteria = 0.93
Lumens per Watt = 60 LpW
Test No. P114165
Test Model: PD612ED010- PDM6930-64VC
Candlepower Distribution
Eyeball at 0-degrees
90º
75º
350
60º
700
45º
1050
0º
15º
30º
Scaling factor for the Battery back up:
- 1800 Lumen = 0.33
- 1200 Lumen = 0.27
Degrees
Vertical
Candela
0*
999
Luminance
Cone of Light Footcandles
(Average Candela/M2)
Degree
Avg. 0°
Luminance
Distance to
Illuminated
Plane
Beam (ft.)
Initial Nadir
Footcandles
L
Length
W
Width
5
990
45
25096
5.5'
33
5
5
15
870
55
15464
7'
20.4
6.4
6.4
25
669
65
5111
8'
15.6
7.4
7.4
35
471
75
0
9'
12.3
8.2
8.2
45
324
85
0
10'
10
9.2
9.2
55
162
12'
6.9
11
11
65
39
75
0
85
0
90
0
*CBCP
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss factors where necessary.
Zonal Lumen Summary
Zone
Lumens
% Fixture
0-30
643
46.6
0-40
940
68.1
0-60
1333
96.7
0-90
1379
100
HALO Commercial
PD612/PD618
PDM6
64V
P H O T OMETRY
PD618ED010- PDM6835-64VC
Candela Distribution
Spacing Criteria = 0.93
Lumens per Watt = 73.7 LpW
Test No. P114146
Test Model: PD618ED010- PDM6835-64VC
Candlepower Distribution
Eyeball at 0-degrees
90º
75º
550
60º
1100
Degrees
Vertical
Candela
0*
1574
Luminance
Cone of Light Footcandles
(Average Candela/M2)
Degree
Avg. 0°
Luminance
Distance to
Illuminated
Plane
Length
W
Width
5
1560
45
39554
5.5'
52
5
5
1488
55
24381
7'
32.1
6.4
6.4
25
1371
65
8055
8'
24.6
7.4
7.4
35
743
75
0
9'
19.4
8.2
8.2
45
510
85
0
10'
15.7
9.2
9.2
55
255
12'
10.9
11
11
65
62
75
0
85
0
90
0
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss factors where necessary.
Zonal Lumen Summary
*CBCP
1650
15º
L
15
45º
0º
Beam (ft.)
Initial Nadir
Footcandles
30º
Scaling factor for the Battery back up:
Zone
Lumens
% Fixture
0-30
1013
46.6
0-40
1482
68.1
0-60
2102
96.7
0-90
2174
100
- 1800 Lumen = 0.33
- 1200 Lumen = 0.27
PD618ED010- PDM6930-64VC
Candela Distribution
Spacing Criteria = 0.93
Lumens per Watt = 57.1 LpW
Test No. P114149
Test Model: PD618ED010- PDM6930-64VC
Candlepower Distribution
Eyeball at 0-degrees
90º
75º
450
60º
900
Degrees
Vertical
Candela
0*
1219
Luminance
Cone of Light Footcandles
(Average Candela/M2)
Degree
Avg. 0°
Luminance
Distance to
Illuminated
Plane
Initial Nadir
Footcandles
W
Width
5
1208
45
30631
5.5'
40.3
5
5
1061
55
18876
7'
24.9
6.4
6.4
25
817
65
6239
8'
19
7.4
7.4
35
575
75
0
9'
15.1
8.2
8.2
45
395
85
0
10'
12.2
9.2
9.2
55
198
12'
8.5
11
11
65
48
75
0
85
0
90
0
Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss factors where necessary.
Zonal Lumen Summary
Zone
*CBCP
1350
15º
L
Length
15
45º
0º
Beam (ft.)
30º
Scaling factor for the Battery back up:
Lumens
% Fixture
0-30
785
46.6
0-40
1147
68.1
0-60
1628
96.7
0-90
1684
100
- 1800 Lumen = 0.33
- 1200 Lumen = 0.27
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
© 2014 Eaton
All Rights Reserved
Printed in USA
Publication No. AHC131423
September 2014
Specifications and
dimensions subject to
change without notice.