Technical Data Effective November 17, 2014 DALI Field Relay Catalog# Prepared by Project Date Comments Type Overview Fifth Light’s Field Relay provides ON/OFF control and network connectivity in order to conserve energy and effectively manage the lighting system. The Field Relay uses advanced switching technology specifically designed to handle the large in-rush currents and inductive loads found in lighting applications. Features Integrated DALI communication interface connects to Eaton's Fifth Light system or any other DALI System for ON/OFF control of lighting and/or receptacles Universal Voltage Input (120V - 347V) Designed with safety in mind, a loss of power on the DALI bus will automatically set the relay to the closed (ON) position Rated for Lighting and Receptacle loads Technical Data DALI Field Relay November 2014 Specifications 120-347 VAC +/- 10% 20 Amps 50/60 Hz 32° F to 158° F (0°C to 70°C) For indoor use only Purple Input Voltage Maximum Load Input Frequency Operating Environment Dimensions Wiring Diagram Power Wires 1.53"H x 3.13"W x 3.44"L (38.86mm x 79.40mm x 87.38mm) Po W DALI Field Relay Line In Relay: 12 AWG stranded THHN non-polarized pair DALI: 18 AWG stranded PTFE plenum rated non-polarized pair Mounting: Fixture or junction box 1/2" knockout Control Communication Interface: Digital Addressable Lighting Interface (DALI) Specification DALI Current Draw: 3.75mA Number of cycles before recharge: 4 Charging time: 20 seconds/cycle Last state upon full depletion: On Note: The relay always maintains enough internal Communication energy to allow users to turn the light on. Wires (DALI) The DALI Field Relay is designed for low frequency Important Note Powerswitching applications, i.e. less than 4 cycles in 2 DALI Wiresminutes Field Relay StandardsLine In Line Out Communication Wires (DALI) Line Out Wiring & Mounting Neutral C Purple Purple Lighting Load Power Wires DALI Field Relay Line In US Communication Wires (DALI) Line Out Neutral Neutral Dimensions Lighting Load (Inches/mm) TOP VIEW Top VIEW SIDE VIEW NNote: Install in accordance with all applicable national and local electrical & building codes. NNote: Specifications subject to change without notice. 1.53/ 38.86 3.13/ 79.38 3.44/ 87.31 2.91/ 78.82 SIDE VIEW Side view 1.53/ 38.86 3.13/ 79.38 3.44/ 87.31 2 0.5/ 12.7 www.coopercontrol.com Lin Technical Data DALI Field Relay November 2014 Sample System Topology DALI COMMUNICATION BUS Maximum of up to 64 devices on each DALI Bus. All devices must be within 900 feet of the Lighting Control Panel (LCP). 16/2 AWG recommended wire. Scene 1 Scene 2 Scene 3 Scene 4 DALI FIELD RELAY DALI DIMMABLE BALLAST 11:46 06/26/09 DALI DAC 0-10 VDC DALI MULTI SENSOR 10% 10% 20% 3 30% 4 40% DALI Wallstation 1000 FIFTH LIGHT TECHNOLOGY 1 2 DALI DIMMING MODULE DALI RELAY PANEL Units Are: 1027.1028 LIGHTS LIGHTING CONTROL PANEL GROUPS SCENES SUPPORT VOIP PHONE TOUCH SCREEN MOBILE APP ETHERNET NETWORK SWITCH CENTRAL SERVER UNIT Ordering Catalog # Description Input Voltage Current FLT-HPRS-DALI Single pole, single throw, 20A latching relay 120/277/347V 20A Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, GA 30269 CooperControl.com © 2014 Eaton All Rights Reserved Printed in USA Publication No. ACC141025 November 17, 2014 Eaton is a registered trademark. All other trademarks are property of their respective owners.