Technical Data Effective August 22, 2014 DALI Dimming Module Catalog# Prepared by Project Date Comments Type Overview Fifth Light’s DALI Dimming Module provides continuous dimming control for incandescent and magnetic low voltage loads. Features Integrated DALI communication interface (can be run in the same conduit as power lines) Forward phase dimming control for incandescent and magnetic low voltage loads Ideal for use in applications requiring finely tuned continuous dimming control Automatic loss of DALI power detection circuit defaults to a programmable state Form factor allows for simple connection to 4” square junction box Technical Data DALI Dimming Module August 2014 Specifications Catalog # LCP Input Voltage Maximum Load Minimum Load 120 VAC +/- 10% 20 Amps Input Frequency 50/60 Hz Operating Environment Dimensions 32°F to 104°F (0°C to 40°C) For indoor use only Wiring & Mounting Power Wiring: Line in, Neutral, Dimmed Line Out, Ground 12 AWG stranded TFN Dimensions (Inches/mm) Top VIEW TOP VIEW 0.125 Amps SIDE VIEW 4.19/ 106.43 8.25"H x 4.19"W x 2.19"D (209.55mm x 106.43mm x 55.36mm) 5.13/ 130.17 DALI: 18 AWG stranded PTFE plenum rated nonpolarized pair 8.2 209 3.13/ 79.38 Grounding: Ground wire must be connected to earth ground TOP VIEW Control Specification Standards Mounting: Mounts to 4" square junction box. Position the heat sink fins vertically. Ensure that there is sufficient area around the heat sink to allow for convection cooling. Communication Interface: Digital Addressable Lighting Interface (DALI) DALI Current Draw: 2mA Analog Dimming: Forward phase line voltage dimming SIDE VIEW 4.19/ 106.43 2.19/ 55.56 8.25/ 209.55 CSA C22.2 No. 184-M1988 (R2009) - Solid State 5.13/ 3.13/ Lighting Controls 130.17 79.38 ANSI/UL Std No. 244A - Solid State Controls for Appliances Side view The DALI Dimming Module is equipped with a bracket for mounting to a 4” junction box. Wires are passed from the underside of the module and through the bracket. Wiring Diagram DALI DALIDimming DALIDimming Module Module (Dual Channel) DALI Line In Neutral Ground Line Out (Dimmed) Lighting Load NNote: Install in accordance with all applicable national and local electrical & building codes. NNote: Specifications subject to change without notice. 2 www.coopercontrol.com Line I Neutr Grou Li Li Technical Data DALI Dimming Module August 2014 Sample System Topology DALI COMMUNICATION BUS Maximum of up to 64 devices on each DALI Bus. All devices must be within 900 feet of the Lighting Control Panel (LCP). 16/2 AWG recommended wire. Scene 1 Scene 2 Scene 3 Scene 4 DALI FIELD RELAY DALI DIMMABLE BALLAST 11:46 06/26/09 DALI MULTI SENSOR DALI DAC 0-10 VDC 10% 10% 20% 3 30% 4 40% DALI Wallstation 1000 FIFTH LIGHT TECHNOLOGY 1 2 DALI DIMMING MODULE DALI RELAY PANEL Units Are: 1027.1028 LIGHTS LIGHTING CONTROL PANEL GROUPS SCENES SUPPORT VOIP PHONE TOUCH SCREEN MOBILE APP ETHERNET NETWORK SWITCH CENTRAL SERVER UNIT Ordering Catalog # Description FLT-HPDM-DALI Single circuit, forward phase, 20 amp dimming module Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, GA 30269 CooperControl.com © 2014 Eaton All Rights Reserved Printed in USA Publication No. ACC140032 August 22, 2014 Eaton is a registered trademark. All other trademarks are property of their respective owners.