Modular Receptacles Project Name: Prepared By: Project Number: Date: Catalog Number: Type: Ground Fault Circuit Interrupter Receptacles 2-Pole, 3-Wire Grounding 15A 125V/AC 20A 125V/AC Hospital Grade GFCIs FEATURES • ArrowLink modular plug and connector incorporate a first make/last break grounding design. • Wire leads (where applicable) are crimped and resistance welded to plug and connector terminals. • Audible “click” when mating plug and connector indicates proper assembly. • Pre-wired plugs provide 100% inspected and consistent torque settings. Back Wire & Side Wire • Exclusive screw terminal guards insulate conductive surfaces. • Hospital Grade models UL Listed, fully compliant with all latest UL943 (4th edition) Class A GFCI and UL498 Hospital Grade requirements. • Tamper Resistant models comply with 2008 NEC® Article 406.11 for all dwelling units. • ShockSentry™ lock-out function prevents miswired line-load connections and GFCI circuitry damage. Tamper Resistant 15A, 125V NEMA 5-15R 426 Catalog No. Color Suffix Description Hospital GFCI 4.19" (106.4mm) 3.28" (83.3mm) Depth with ArrowLink 1.65" (41.9mm) VGFH20_MOD 426 Catalog No. Color Suffix ■ VGFH15___MOD • ■ VGFH20___MOD B, GY, LA, RD, V, W • ■ VGFH20F___MOD B, GY, LA, RD, V, W B, GY, LA, RD, V, W Hospital GFCI NAFTA Compliant 20A, 125V NEMA 5-20R 1.30" (33.0mm) • ■ VGFH15F___MOD B, GY, LA, RD, V, W • Tamper Resistant Hospital GFCI ■ TRVGFH15___MOD Tamper Resistant Hospital GFCI NAFTA Compliant ■ TRVGFH15F___MOD B, GY, LA, RD, V, W • • • B, GY, LA, RD, V, W ■ TRVGFH20F___MOD • • B, GY, LA, RD, V, W Lead Length: 6.00” (152.4mm) 0.58" (14.7mm) • ■ TRVGFH20___MOD B, GY, LA, RD, V, W • 1.46" (37.1mm) • including ground screw & ring terminal 1.38" (35.1mm) Receptacle SPD Push-In Connector 1.46" (37.1mm) Includes standard size unbreakable wallplate Lead Length: 6.00” (152.4mm) 0.57" (14.5mm) 1.33" (33.8mm) ArrowLink Receptacle Connectors Type Description Catalog No. ArrowLink SPD Push-In Building Wire Connector ■ MCR300FTPI Push-In Building Wire Connector, No Ground Conductor ■ MCR300FTPING ArrowLink SPD Screw Terminal Building Wire Connector ■ MCR300FTST Screw Terminal Building Wire Connector, No Ground Conductor ■ MCR300FTSTNG 125V Solid Wire Building Wire Connector ■ MCR125SOL 125V Stranded Wire Building Wire Connector ■ MCR125STR 250V Solid Wire Building Wire Connector ■ MCR250SOL 250V Stranded Wire Building Wire Connector ■ MCR250STR ArrowLink Receptacle SPD Screw Terminal Connector 1.42" (36.1mm) Lead Length: 6.00” (152.4mm) 0.51" (13.0mm) 1.15" (29.2mm) Leaded Receptacle Connector 1.42" (36.1mm) Patent Pending 0.40" (10.2mm) 1.08" (27.4mm) Receptacle Plug Icon Key Hospital Grade Build-To-Spec Customizable Devices NAFTA Compliant, see Arrow Hart Buyer’s Guide pg O-30 for more information TESTING & CODE COMPLIANCE MATERIAL CHARACTERISTICS • Base Device: cULus Listed to UL 498 and UL 943, file no. E60120; meets all UL 943 (GFCI), UL 498 (Receptacles), UL 498 Hospital Grade and applicable CSA requirements • ArrowLink: Plug & connector cULus Listed to UL 2459 file no. E325188 • Combined: cULus Listed wiring assembly, UL file no. E326691 • Nylon with PVC terminal guards, except single: adhesive terminal barrier • Environmental, Base Device: Flammability meets UL 94 requirements; V2 rated; temperature rating: -20ºC to 90ºC (-4ºF to 194ºF), except single: -20ºC to 60ºC (-4ºF to 140ºF) • Environmental, ArrowLink: Flammability meets UL 94 requirements; V2 rated; temperature rating: -20ºC to 90ºC (-4ºF to 194ºF) max. www.cooperwiringdevices.com Modular Receptacles Specification & Performance Data Project Name: Prepared By: Project Number: Date: Catalog Number: Type: Hospital Specification Grade Ground Fault Circuit Interrupter Receptacles Hospital Grade Tamper Resistant Duplex GFCI 15A & 20A: TRVGFH__MOD and TRVGFH__F__MOD Series ArrowLink: MCR125_, MCR250_, MCR300_ Series Back & side wire Integral wire leads, crimped & resistance welded Backwire feed through Combined Hospital Grade Duplex GFCI 15A & 20A: VGFH_MOD Series and VGFH__F__MOD ArrowLink: MCR125_, MCR250_, MCR300_ Series Back & side wire Integral wire leads, crimped & resistance welded Backwire feed through • cULus Listed to UL 498 and UL 943, file no. E60120 • Meets all UL 943 (GFCI), UL 498 (Receptacles), UL 498 Hospital Grade and applicable CSA requirements • NOM certified • Plug & connector cULus Listed to to UL 2459, file no. E325188 • cULus Listed wiring assembly, UL file no. E326691 Flammability Meets UL 94 requirements; V2 rated Meets UL 94 requirements; V2 rated Temperature Rating -35ºC to 66ºC (-31ºF to 150.8ºF) -35ºC to 66ºC (-31ºF to 150.8ºF) Flammability Meets UL 94 requirements; V2 rated Meets UL 94 requirements; V2 rated Temperature Rating -35ºC to 66ºC (-31ºF to 150.8ºF) -35ºC to 66ºC (-31ºF to 150.8ºF) Device Type Testing & Code Compliance Wiring Type Base Device ArrowLink ArrowLink SPD Base Device ArrowLink Base ArrowLink Device Specifications: Environmental 2-Pole, 3-Wire Grounding 15A, 125V/AC; 20A, 125V/AC NEMA 5-15, 5-20 Withstands 2000V per UL 498 Yes, at full-rated current Max. 30ºC (86°F) after 100 cycles of overload @ 150% of rated Temperature Rise current (DC) 0.025 seconds (Class A) Trip Time 60 Hz; Voltage: 125V; Amperage: 15A/20A 20A Feed Through Frequency Meets and exceeds 10 kA Short Circuit Testing Maximum Interrupting Capacity 20 Amps 300V/AC Max. Working Voltage 20A Max. Continuous Current 52.5A/AC for 10 cycles Overload Withstands 1600V per UL 2459 Dielectric Voltage Limited cycles at full-rated current Current Interrupting Max. 50ºC (122°F) while conducting 35A after 10 cycles of Temperature Rise overload @ 52.5A/AC ArrowLink Specifications: Electrical Base Device Dielectric Voltage Current Interrupting Specifications: Mechanical Base Device Terminal Accommodation ArrowLink Wire Leads ArrowLink SPD Screw Terminals ArrowLink SPD Ground ArrowLink ArrowLink SPD Materials: Base Device Specifications: Screw Terminal Guards Voltage Rating ArrowLink Models Only Top Housing Bottom Housing Strap Line Contacts Terminal & Ground Screws Terminal Clamps Housing • cULus Listed to UL 498 and UL 943, file no. E60120 • Meets all UL 943 (GFCI), UL 498 (Receptacles), UL 498 Hospital Grade and applicable CSA requirements • NOM certified • Plug & connector cULus Listed to to UL 2459, file no. E325188 • cULus Listed wiring assembly, UL file no. E326691 Withstands 2000V per UL 498 Yes, at full-rated current Max. 30ºC (86°F) after 100 cycles of overload @ 150% of rated current (DC) 0.025 seconds (Class A) 60 Hz; Voltage: 125V; Amperage: 15A/20A 20A Feed Through Meets and exceeds 10 kA 20 Amps 300V/AC 20A 52.5A/AC for 10 cycles Withstands 1600V per UL 2459 Limited cycles at full-rated current Max. 50ºC (122°F) while conducting 35A after 10 cycles of overload @ 52.5A/AC #14 - #10 AWG #14 - #10 AWG #12 AWG #12 AWG Accepts #12-#14 stranded and solid wire Accepts #12-#14 stranded and solid wire Integral THHN #12 AWG 6" lead with ring terminal and #10 ground screw Permanently marked on device Integral THHN #12 AWG 6" lead with ring terminal and #10 ground screw Permanently marked on device Material: UL recognized insulating material Dielectric Strength: 2,000V min. HWI Rating: 4 min. Relative temperature index, electrical: 80ºC (176ºF) Flammability: V0 (UL 94) Material: UL recognized insulating material Dielectric Strength: 2,000V min. HWI Rating: 4 min. Relative temperature index, electrical: 80ºC (176ºF) Flammability: V0 (UL 94) Thermoplastic, nylon Polycarbonate 0.047" thick steel, zinc plated 0.030" thick brass #8-32 steel, brass plated; neutral screw nickel plated, ground screw green 0.070" thick steel Thermoplastic, nylon Polycarbonate 0.047" thick steel, zinc plated 0.030" thick brass #8-32 steel, brass plated; neutral screw nickel plated, ground screw green 0.070" thick steel Polycarbonate Polycarbonate Contacts Copper alloy Copper alloy Wire Leads Solid or stranded THHN #12 AWG Solid or stranded THHN #12 AWG Housing Polycarbonate Polycarbonate Contacts Copper alloy Copper alloy Specifications subject to change without notice. 2-ALMSPSH7-0311 www.cooperwiringdevices.com