PORTFOLIO TM D ES C R IPTION Low brightness 7-3/8-inch aperture lensed wall wash for use with (2)18W or 26W Quad tube 4-pin compact fluorescent lamps. The specular reflector and concave spread lens provide uniform light distribution on vertical surfaces. Standard features include low iridescent finish on all reflector colors to eliminate "rainbowing" and one electronic ballast to operate both lamps. Venting ensures maximum lamp life and lumen output. Optics offer smooth wash of light. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S Re f l e c t o r Hous i ng Mountin g Frame S ock et Specular clear upper Alzak® reflector for maximum output. Lower spun parabolic reflector, .050 thick aluminum, available in a variety of Alzak® finishes. Torsion spring mounting pulls trim tight to ceiling. One piece precision die cast aluminum 1-1/2" deep collar accommodates varying dimensions of ceiling materials. 18W 4 pin G24q2 or 26W 4 pin G24q3 base accepts Quad tube lamps. Fatigue free stainless steel lamp spring ensures positive lamp retention. Le n s Concave glass spread lens provides even vertical illumination. Lens is fixed to lower reflector. U ni v e rs a l Moun ting B racket Accepts 1/2" EMT, C Channel, T bar fasteners, and bar hangers. Adjusts 5" vertically from above or below ceiling. Condui t F i tti ngs Electron ic B allast Electronic ballast provides full light output and rated lamp life. Provides flicker free and noise free operation and starting. End of lamp life protection is standard. Die cast screw tight connectors. Trim Ring Options Self flanged or white metal trim ring. So c k e t C o n n e c t or One piece die cast aluminum connection allows venting for maximum thermal performance. Labels J unc ti on Box cULus listed, Wet label. Listed for eight #12AWG (four in, four out) 90°C conductors feed through branch wiring. 1/2" and two 3/4" pry outs. Positioned to allow straight conduit runs. Access to junction box by removing reflector. CLW7218 CLW7226 7491/7493 (2) 18W, 26W Quad Compact Fluorescent STEPREPEAT> 7-Inch Lensed Wall Wash ENERGY DATA 18W DTT Ballast: Electronic 120V Input Watts: 37 Line Amps: 0.32 277V Input Watts: 37 Line Amps: 0.14 Power Factor: >0.99 THD: <10% Min. Starting Temperature: -18°C (0°F) Sound Rating: Class A Standards 7-1/2" [190mm] 26W DTT Ballast: Electronic 120V Input Watts: 52 Line Amps: 0.44 277V Input Watts: 52 Line Amps: 0.19 Power Factor: >0.98 THD: <20% Min. Starting Temperature: 0°F Sound Rating: Class A Standards Top View NOTES: Accessories should be ordered separately. For additional options, please consult your Cooper Lighting Representative. Alzak is a registered trademark of Aluminum Company of America. 7-1/8" [181mm] 13" [330mm] 8" [203mm] 8-3/4" [222mm] 15-1/4" [387mm] Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADP021470 2013-09-27 16:00:00 CLW7218 CLW7226 7491/7493 ORDER ING INFOR M A TION EXAMPLE: CLW7218E 7493W Housing Lamps Wa tt a g e CLW7=7" Lens Wall Wash 2=2 Lamps 18=18W DTT Lamp 26=26W DTT Lamp Ballast Options Tri m s E=120/277V 50/60 Hz Electronic 3E=347V 50/60 Hz Electronic D5LT=120-277V Fifth Light (DALI Dimming) 3D5LT=347V Fifth Light (DALI Dimming) (26W only) D=120-277V Lutron Ecosystem Dimming CP=Chicago Plenum EM=Emergency Module with remote test switch Finish A c c e s s o ri e s Option 7491=Self Flanged 7493=Metal Trim Ring, White WF=White Painted Flanged (Self Flanged only) LI=Low Iridescent Clear H=Haze WMH=Warm Haze G=Gold WH=Wheat W=Gloss White GP=Graphite GPH=Graphite Haze HB26=C Channel Bar Hangers, 26" Long, Pair HB50=C Channel Bar Hangers, 50" Long, Pair FK5=5 Amp Field Installable Fuse Kit 300V Max RMB-22=Wood Joist Bar Hanger, 22" Long, Pair PH OTOM ETR IC S Candlepower Distribution Test No. ITL52163 CLW7226 7493LI Lamp=(2) 26W/DTT Lumens=1800 150 300 Average Luminance Candlepower 450 600 750 0° W all 180 ° Dwnlt 900 2'6" Distance From Wall Deg . 0 0° W al l 474 180° Dwnlt 474 5 15 503 500 434 293 25 35 435 346 167 102 45 55 65 75 247 144 63 17 56 19 1 0 85 90 2 0 0 0 CD/SQM 180° Dwnlt 45 55 1333 8 958 6 3024 1265 65 75 85 569 2 250 8 876 90 0 0 3' Distance From Wall Spacing Between Fixtures DD 1 Deg . 0° W al l –––––– 3' –––––– Single Fixture 2'6" From Wall Distance From Fixture Along W all 6 1' 4 2' 1 3' 0 4' 0 5' 0 6' 0 3 4 14 13 9 11 11 8 5 6 5 2 3 3 1 1 2 0 1 1 0 0 0 5 6 6 4 5 4 4 3 3 2 2 1 1 1 1 1 7 8 3 2 3 2 2 2 2 1 1 1 1 1 1 1 9 2 1 1 1 1 1 0 10 1 1 1 1 1 1 0 DD 1 2 4' Distance From Wall Spacing Between Fixtures –––––– 4' –––––– DD 1 –––––– 3' –––––– 4 3 4 Spacing Between Fixtures –––––– 4' –––––– 3 2 3 DD 1 –––––– 4' –––––– 1 1 1 1 –––––– 6' –––––– 1 1 7 5 7 6 3 6 2 3 18 16 18 15 10 15 12 12 10 8 10 4 5 3 2 3 19 15 13 15 16 16 16 13 11 13 2 3 5 19 2 3 12 19 8 8 8 6 5 6 4 5 16 13 16 12 16 12 12 10 12 9 12 9 4 5 15 13 15 13 15 12 12 10 11 10 12 10 4 5 9 9 9 9 9 9 6 6 6 6 6 6 6 7 10 7 10 7 9 7 7 6 7 6 7 6 6 7 10 8 10 8 10 8 8 6 8 6 8 6 6 7 8 7 8 7 8 7 5 5 5 5 5 5 8 6 5 4 6 5 4 5 4 3 5 4 3 5 4 3 4 4 3 8 7 5 4 7 5 4 6 5 4 5 4 4 5 4 4 5 4 3 8 6 5 4 6 5 4 6 5 4 4 3 3 4 4 3 4 4 3 9 10 Notes: • Illuminance values for multiple centerline of 9 10 Distance From W all New Fc= spacing will Existing Spacing New Spacing Spacing Between Fixtures are based upon the center two units of a four unit arra y. Footcandle values are and centered between • Illuminance values are cosine corrected initial values with no contribution from inter surfaces. Total illumination may increase from contributions from other surfaces. • Changing 9 10 s from other room DD=Distance Down From Ceiling illuminance level. x Average Table Fc Level • When selecting colored cones option, only downlight cone is colored; the wall wash allows the color (CRI, °K) of the light source to be d and maximizes lumen output. is specular clea r. This Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 CL ADP021470 2013-09-27 16:00:00