HALO Commercial DESCRIPTION Type Catalog # Recessed 6 inch aperture lens downlight for vertical PAR30L or PAR38 metal halide lamp. Electronic ballast suitable for 120 volt or 277 volt operation. Fixture is suitable for commercial construction and wet location listed. Insulation must be kept 3" from top and sides of housing. Specify housing and trim separately to complete luminaire. Project Date Comments Prepared by SPECIFICATION FEATURES MECHANICAL Frame Boat shaped galvanized steel frame with 1/2" plaster lip accommodates ceilings up to 2" thick. May be used for new construction or remodeling installations. Provided with (2) remodel clips to secure frame when installed from below the ceiling. Mounting Brackets Bar hanger receivers adjusts 2" vertically from above the ceiling or thru the aperture. Use with No Fuss™ bar hangers or with 1/2" EMT. Removable to facilitate installation from below the ceiling. No Fuss™ Bar Hangers Pre-installed and centered bar hanger locks to tee grid with a screwdriver or pliers. Centering marks on the bar hanger mechanism allows consistent positioning of fixtures. OPTICAL Reflector One piece aluminum reflector secures lens in place with integrated spring clips for a visually comfortable optic and allows for tool-less lens exchange from below the ceiling. Available with clear, diffuse, prismatic, fresnel or drop opal glass lens. Self flanged standard. -Specular Reflectors - Polished flange standard with white painted flange option. -Baffles and White Reflector - White painted flange standard. securely to reflector with turn and lock mechanism. Control Gear Dual input 120V/277V or 347V electronic ballast. Insulation Detector Self heating insulation detector opens circuit if insulation is improperly installed. Code Compliance - Thermally protected and cULus listed for wet locations. Trim Retention -IP44 rated for lens trims Reflector is retained with two torsion springs and held tightly to - EMI/RFI per FCC Title 47 CFR, the finished ceiling surface. Part 18, non consumer limits. ELECTRICAL - High efficacy luminaire may be Junction Box used to meet IECC, ASHRAE, (6) 1/2" and (2) 3/4" trade size pry and Title 24 commercial outs positioned to allow straight standards. conduit runs. Listed for (12) - Meets California T20 and #12 AWG (six in, six out) 90°C conductors and feed thru branch Federal EISA ballast efficiency standards. wiring. Lamp Socket Pulse rated E26 medium base protected porcelain socket with nickel plated brass screw shell. PD6P39E PD6P70E PD6P100E 60V 39, 70, 100W PAR30L, PAR38 Metal Halide 6-Inch Aperture Lens Downlight New Construction or Remodel Socket Cap One piece metal cap attached Non-IC DIMENSIONS 8.887" [225.73mm] 6.375" I.D. [161.93mm] 7.250" [184.15mm] 7.750" O.D [196.85mm] 26.400" [670.56mm] 7.432" [188.77mm] 13.109" [332.98mm] ADV111749 December 11, 2012 1:05 PM HALO Commercial PD6P39E PD6P70E P D 6 P 10 0 E 60V E N E R G Y D ATA PD6P39E, PD6CPP39E Min. Starting Temp -15°C, +5°F PD6P70E, PD6CPP70E Sound Rating Class A Min. Starting Temp -15°C, +5°F Sound Rating Class A PD6P100E, PD6CPP100E Min. Starting Temp -15°C, +5°F Sound Rating Class A EMI/RFI Emissions FCC 47CFR Part 18 Non-Consumer Limits EMI/RFI Emissions FCC 47CFR Part 18 Non-Consumer Limits EMI/RFI Emissions FCC 47CFR Part 18 Non-Consumer Limits Input Frequency 50/60 Hz Power Factor > 0.95 Input Frequency 50/60 Hz Power Factor > 0.95 Input Frequency 50/60 Hz Power Factor > 0.95 THD < 4% @ 120V Input Voltage 120V/277V ±10% THD < 6% @ 120V Input Voltage 120V/277V ±10% THD < 8% @ 120V Input Voltage 120V/277V ±10% THD < 9% @ 277V THD < 12% @ 277V THD < 11% @ 277V Crest factor < 1.5 Ballast factor 1.00 Crest factor < 1.5 Ballast factor 1.00 Crest factor < 1.5 Ballast factor 1.00 Operating Frequency 140 Hz cULus Listed, Type 1 Outdoor Operating Frequency 140 Hz cULus Listed, Type 1 Outdoor Operating Frequency 140 Hz cULus Listed, Type 1 Outdoor Input Power 46W 39PAR30L, CDM35/PAR30L/M/ 39PAR30L, CMH39PAR30L/ 39PAR30LN, MCP39PAR30LN/U/ Input Current 0.39A @ 120V Input Current 0.18A @ 277V 70PAR30L, CDM70/PAR30L/M/ 70PAR30L, CMH70PAR30L/ 70PAR30LN, MCP70PAR30LN/U/ 70PAR38, CDM70/PAR38/ 70PAR38, CMH70PAR38/ 70PAR38, MCP70PAR38/U/ PD6P393E Min. Starting Temp -30°C, -22°F Input Power 81W @ 120V Input Power 80W @ 277V Input Current 0.69A @ 120V Input Power 112W @ 120V 100PAR38, CDM100/PAR38/ 100PAR38, CMH100PAR38/ 100PAR38, MCP100PAR38/U/ Input Current 0.30A @ 277V Input Power 109W @ 277V Input Current 0.96A @ 120V Input Current 0.43A @ 277V Sound Rating Class A PD6P703E EMI/RFI Emissions FCC 47CFR Part 18 Non-Consumer Limits, Subparts C Min. Starting Temp -30°C, -22°F PD6P1003E Sound Rating Class A Min. Starting Temp -30°C, -22°F Sound Rating Class A Input Frequency 50/60 Hz Power Factor > 0.99 EMI/RFI Emissions FCC 47CFR Part 18 Non-Consumer Limits, Subparts C THD < 10% Input Voltage 347V ±10% Input Frequency 50/60 Hz Power Factor > 0.99 Input Frequency 50/60 Hz Power Factor > 0.99 Crest factor < 1.6 Ballast factor 1.00 THD < 10% Input Voltage 347V ±10% THD < 10% Input Voltage 347V ±10% Operating Frequency 170 Hz UL Listed, cUL Certified, Class P, Type 1 Outdoor, HL Crest factor < 1.6 Ballast factor 1.00 Crest factor < 1.6 Ballast factor 1.00 Operating Frequency 170 Hz UL Listed, cUL Certified, Class P, Type 1 Outdoor, HL Operating Frequency 170 Hz UL Listed, cUL Certified, Class P, Type 1 Outdoor, HL 100PAR38, CDM100/PAR38/ 100PAR38, CMH100PAR38/ 100PAR38, MCP100PAR38/U/ Input Power 108W 39PAR30L, CDM35/PAR30L/M/ 39PAR30L, CMH39PAR30L/ 39PAR30LN, MCP39PAR30LN/U/ Input Power 45W Input Current 0.12A @ 347V 70PAR30L, CDM70/PAR30L/M/ 70PAR30L, CMH70PAR30L/ 70PAR30LN, MCP70PAR30LN/U/ 70PAR38, CDM70/PAR38/ 70PAR38, CMH70PAR38/ 70PAR38, MCP70PAR38/U/ Input Power 80W EMI/RFI Emissions FCC 47CFR Part 18 Non-Consumer Limits, Subparts C Input Current 0.31A @ 347V Input Current 0.23A @ 347V ORDERING INFORMATION SAMPLE NUMBER: PD6P70E 60V1GC O r d e r h o u s i n g , r e fl e c t o r a n d l a m p s e p a r a t e l y f o r a c o m p l e t e l u m i n a i r e . Housing PD6P = 6 Inch vertical E26 (protected) PAR metal halide PD6CPP = 6 Inch vertical E26 (protected) PAR metal halide, CCEA listed (Chicago Plenum) Wattage / Ballast Option 39E = 39W MH, M130, 120V/277V 393E = 39W MH, M130, 347V 70E = 70W MH, M98, M139, 120V/277V 703E = 70W MH, M98, M139, 347V 100E = 100W MH, M90, M140, 120V/277V 1003E = 100W MH, M90, M140, 347V www.cooperlighting.com Reflector 60V = 6” vertical Lens Option 1G=Prismatic Glass 2G=Diffuse Glass 3G=Clear Glass 4G=Fresnel Glass Finish Option C=Specular Clear G=Specular Gold H=Semi Specular Clear W=White (White Flange) BB=Black Baffle (White Flange) WB=White Baffle (White Flange) Polymer “Dead Front” Trim 1 1GDF=Prismatic Glass with “Dead Front” Trim 2GDF=Diffuse Glass with “Dead Front” Trim 3GDF=Clear Glass with “Dead Front” Trim 4GDF=Fresnel Glass with “Dead Front” Trim 5GDF=Drop Opal Glass with “Dead Front” Trim Flange Option Blank=Polished Flange (C, G, H) Blank=White flange (W, BB, WB) WF=White Flange (C, G, H) Accessories HB128APK = L channel hanger bar, 26”, ‘No-Fuss’, pair (replacement) RMB22 = 22” long wood joist mounting bars Note: 1 “DF” trim option includes Specular Clear (C) reflector and white polymer flange only. No other finish or flange options apply. HALO Commercial PD6P39E PD6P70E P D 6 P 10 0 E 60V P H OTO M E T RY PD6P100E-60V1GC_100PAR38 Candela Distribution Spacing Criteria = 0.96 Lumens per Watt = 55 LpW Test No. P21695 Test Model: PD6P100E-60V1GC_100PAR38 Candlepower Distribution Curve 90° 80° 70° 60° 50° 40° 30° 0° 10° 20° Luminance Degrees Vertical Candela 0* 4085 5 3958 15 3389 25 35 (Average Candela/M2) Cone of Light Footcandles Avg. 0° Luminance Distance to Illuminated Plane Initial Nadir Footcandles 45 70496 5.5' 55 32288 7' 2781 65 8933 2154 75 612 45 1229 85 153 55 495 65 114 75 6 85 1 90 0 Degree Beam (ft.) L W Length Width 135 5.2 5.2 83 6.6 6.6 8' 64 7.6 7.6 9' 50 8.5 8.5 10' 41 9.5 9.5 12' 28 11.4 11.4 14' 21 13.3 13.3 Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. Zonal Lumen Summary *CBCP Zone Lumens % Lamp % Fixture 0-30 2603.3 40.10 47.60 0-40 3934.47 60.50 72.00 0-60 5336.03 82.10 97.60 0-90 5468.33 84.10 100.00 Note: Specifications and Dimensions subject to change without notice. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 www.cooperlighting.com Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049