COOPER LIGHTING - METALUX

advertisement
COOPER LIGHTING - METALUX
®
DESCRIPTION
The AccordTM redefines fluorescent lighting by improving on aesthetics,
comfort and energy savings. The Accord provides the right amount
of light while eliminating surface shadows commonly found in
parabolics. Therefore, Accord increases the comfort level while
providing significant energy savings.
Type
Catalog #
Project
Date
Comments
The Accord is the ideal solution for offices, schools, hospitals, retail
and other applications.
Prepared by
SPECIFICATION FEATURES
Construction
Ballast Access
Air Return
Shallow 3-1/4" deep housing is die
formed of code gauge, prime cold
rolled steel. Heavy gauge end plates
are securely attached with screws for
strength and rigidity and the elimination of gaps. Four auxiliary fixture end
suspension points are provided. KOs
for continuous row wiring. Large
access plate for supply connection.
Ballast can be removed from
below without tools.
Optional Air Return model
provides air flow through air
slots in the housing.
Electrical*
Reflectors
Ballasts are Class “P” and are positively secured. Rotor-lock lampholders
ensure positive lamp retention.
UL/CUL listed. Suitable for damp
locations.
Reflector has high reflectance
baked matte white enamel finish for luminous uniformity.
Finish
Durable cold rolled steel with multistage, iron phosphate pretreatment and white enamel finish to
ensure maximum bonding and
rust inhibition.
Shielding
Controls
Fifth Light ballast options are
offered for both 0-10V continuous dimming and DALI applications. Combine with energysaving products like occupancy sensors, daylighting
controls, and lighting relay
panels from Cooper Controls
(www.coopercontrol.com) to
maximize energy savings.
2AC
217T8
T8 LAMPS
Positively retained frosted acrylic
profile lenses provide a soft but
effective distribution of light.
2' x 2' Recessed
Tr o f f e r S e r i e s
3-1/4"
[83mm]
23-3/4"
[603mm]
LAMP CONFIGURATIONS
MOUNTING DATA
11-3/4" [298mm]
Access Plate
3-1/4"
[83mm]
ENERGY DATA
23-3/4" [603mm]
Input Watts:
EB Ballast & STD Lamps @ 277V
217T8 (30)
1-1/2"
[39mm]
23-3/4"
[603mm]
Luminaire Efficacy Rating
LER =FL69 LPW
Catalog Number: 2AC-217
3-3/8"
[86mm]
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.47
3-1/16"
[78mm]
24" [610mm]
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
NOTE: 2' x 2' and 2' x 4' allow for row mounting
(1' x 4' does not support feature)
**Consult Pre Sales Technical Support.
***See Drywall Frame Kit Accessory
CEILING COMPATIBILITY
G
Grid/Lay-in
Standard
COOPER LIGHTING
F
Drywall Frame
Kit
Ceiling
Type**
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
G
G or T
G or T
***
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO
LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF080358
2AC
PHOTOMETRICS
Candela
2AC-217
Electronic Ballast
(2) F17T8/TL841 lamps Angle Along II
0
737
1400 lumens
5
735
10
724
Spacing criterion:
15
707
(II) 1.2 x mounting
20
682
height, (⊥) 1.4 x
25
652
mounting height
30
616
35
574
Efficiency 84.3%
40
527
Test Report:
45
476
2AC-217.IES
50
422
55
366
LER = FL-69 LPW
60
308
Yearly Cost of 1000
65
248
188
lumens, 3000 hrs at 70
75
129
.08 KWH = $3.47
80
85
90
Across ⊥
737
737
735
729
720
707
690
669
643
613
576
533
475
380
266
169
92
33
0
45°
737
735
729
719
703
683
658
628
594
555
511
462
408
349
274
181
99
34
0
76
32
0
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
100
91
83
75
69
63
58
54
50
46
44
100
87
76
66
58
52
46
42
38
35
32
100 100
84 80
70 65
59 53
50 45
44 38
38 33
34 29
31 26
28 23
25 21
98
89
80
73
67
61
56
52
48
45
42
98
85
74
65
57
51
46
41
38
34
32
98
82
68
58
50
43
38
34
30
28
25
98
79
64
53
44
38
33
29
26
23
21
20%
50%
50 30 10
30%
50 30 10
50
94
82
71
62
55
49
44
40
36
33
31
90
78
68
60
53
47
43
39
35
32
30
86
75
66
57
51
46
41
37
34
32
29
94
79
66
56
49
42
37
33
30
27
25
94
76
62
52
44
37
33
29
25
23
21
90
76
64
55
47
41
37
33
30
27
24
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
588
979
1813
2360
2360
%Lamp
21.0
35.0
64.7
84.3
84.3
%Fixture
24.9
41.5
76.8
100.0
100.0
Average
0-Deg
cd/sm
1830
1735
1595
1355
998
90
74
61
51
43
37
32
28
25
23
21
Average
45-Deg
cd/sm
2134
2190
2245
1901
1060
10%
30 10
86
73
62
53
46
41
36
32
29
26
24
86
72
59
50
42
37
32
28
25
23
21
0%
0
84
70
58
48
41
35
30
26
23
21
19
Average
90-Deg
cd/sm
2357
2526
2444
1775
1029
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
4/13
ADF080358
ORDERING INFORMATION
SAMPLE NUMBER: 2AC-217-UNV-EB82-U
Rating
Blank=
Standard
NY=New York
Rated
ATW-SW4=
Chicago
Rated
Width
2=2' Width
Series
AC=Accord Series
Number of Lamps
(Not included)
2=2 Lamp
Wattage (Length)
17=17W T8 (24")
Shielding
Blank=Frosted Acrylic
SQP=Lens with Square
Pattern Insert
RDP=Lens with Round
Pattern Insert
Lamps
L8835=T8 Lamp,
17W and 32W,
3500K
L8841=T8 Lamp,
17W and 32W,
4100K
Voltage (1)
UNV=Universal
Voltage 120-277
Options
GL=Single Element Fuse
GM=Double Element Fuse
Flex=Flex installed
Type
A=Air (optional)
(1)
(2)
NOTES: Products also available in non-US voltages and frequencies for international markets. For a complete listing of
(3)
Fifthlight Technology products and other solutions from Cooper Controls, visit www.coopercontrol.com. 0-10V ballast do not
(4)
include DALI feature. Please select DALI ballast for use with Fifth Light system. Specification grade 0-10V dimming ballast are
NEMA premium and CEE listed. They are compatible with low mercury and energy saving lamps.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without
notice. Consult your Cooper Lighting Representative for availability and ordering information.
Ballast Type
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8 /PLUS= T8 Electronic Instant Start.
High Ballast Factor >1.13.
Total Harmonic Distortion < 20%
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
High Performance T8 Ballasts
HB8 L=T8 Electronic Instant Start.
Low Ballast Factor .77
HB8 =T8 Electronic Instant Start.
Ballast Factor .88
HB8 N=T8 Electronic Instant Start.
Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start.
High Ballast Factor 1.15-1.2
HR8 DIM=T8 Electronic Program Start
Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Start.
Low Ballast Factor .77
HR8 =T8 Electronic Program Start.
Ballast Factor .88
HR8 H=T8 Electronic Program Start.
High Ballast Factor 1.15-1.2
Packaging
U=Unit Pack
PALC=Job
Pack, in carton
0-10V Dimming Ballasts (3)
5LTV8=T8 0-10V Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 0.87
5LTVS8=T8 0-10V Spec Grade Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 0.87 (4)
Fifth Light DALI Ballasts (2)
5LT8 =T8 DALI Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 1.0
Number of Ballasts
1=1 Ballast
2=2 Ballasts
ACCESSORIES
T3A END E.Q. BRACKET PARTS BAG
SHIPPING INFORMATION
Catalog No.
2AC-217
Wt.
28 lbs.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 4/13
ADF080358
Download