COOPER LIGHTING - METALUX ® DESCRIPTION The AccordTM redefines fluorescent lighting by improving on aesthetics, comfort and energy savings. The Accord provides the right amount of light while eliminating surface shadows commonly found in parabolics. Therefore, Accord increases the comfort level while providing significant energy savings. Type Catalog # Project Date Comments The Accord is the ideal solution for offices, schools, hospitals, retail and other applications. Prepared by SPECIFICATION FEATURES Finish Air Return Shallow 3-1/4" deep housing is die formed of code gauge, prime cold rolled steel. Heavy gauge end plates are securely attached with screws for strength and rigidity and the elimination of gaps. Four auxiliary fixture end suspension points are provided. KOs for continuous row wiring. Large access plate for supply connection. Durable cold rolled steel with multistage, iron phosphate pretreatment and white enamel finish to ensure maximum bonding and rust inhibition. Optional Air Return model provides air flow through air slots in the housing. Electrical* Shielding Ballasts are Class “P” and are positively secured. Rotor-lock lampholders ensure positive lamp retention. UL/CUL listed. Suitable for damp locations. Positively retained frosted acrylic profile lenses provide a soft but effective distribution of light. Construction Reflectors Reflector has high reflectance baked matte white enamel finish for luminous uniformity. Controls Fifth Light ballast options are offered for both 0-10V continuous dimming and DALI applications. Combine with energysaving products like occupancy sensors, daylighting controls, and lighting relay panels from Cooper Controls (www.coopercontrol.com) to maximize energy savings. 2AC 214T5 224T5 T5 LAMPS Ballast Access 2' x 2' Recessed Tr o f f e r S e r i e s Ballast can be removed from below without tools. 3-1/4" [83mm] 23-3/4" [603mm] LAMP CONFIGURATIONS MOUNTING DATA 11-3/4" [298mm] Access Plate ENERGY DATA 3-1/4" [83mm] Input Watts: 23-3/4" [603mm] EB Ballast & STD Lamps @ 277V 214T5 (30) 224T5 (52) 1-1/2" [39mm] 23-3/4" [603mm] Luminaire Efficacy Rating LER =FL77 LPW Catalog Number: 2AC-214T5 3-3/8" [86mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.65 3-1/16" [78mm] 24" [610mm] *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. NOTE: 2' x 2' and 2' x 4' allow for row mounting (1' x 4' does not support feature) **Consult Pre Sales Technical Support. ***See Drywall Frame Kit Accessory CEILING COMPATIBILITY G Grid/Lay-in Standard COOPER LIGHTING F Drywall Frame Kit Ceiling Type** Trim Type Exposed Grid Concealed T Slot Grid Flange G G or T G or T *** LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF051721 2AC PHOTOMETRICS 2AC-214T5 Electronic Ballast (2) F14T5/835 lamps 1350 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency 89.4% Test Report: 2AC-214T5.IES LER = FL-77 LPW Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.65 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 755 752 741 723 698 667 630 587 539 487 432 374 314 253 191 131 76 31 0 106 93 80 70 62 55 49 44 40 37 34 106 106 89 85 74 68 62 56 53 47 46 40 41 35 36 31 33 27 29 24 27 22 104 94 85 77 71 65 60 55 51 48 45 104 90 78 68 60 54 48 44 40 36 34 104 87 73 61 53 46 40 36 32 29 27 104 84 68 56 47 40 35 31 27 24 22 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 99 87 75 66 58 52 47 42 39 35 33 95 83 72 63 56 50 45 41 37 34 32 91 80 69 61 54 48 44 40 36 34 31 89 74 61 51 43 37 32 28 25 22 20 99 84 70 60 51 45 40 35 32 29 26 99 81 66 55 46 40 34 30 27 24 22 95 81 68 58 50 44 39 35 31 28 26 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 601 1001 1851 2414 2414 %Lamp 22.3 37.1 68.6 89.4 89.4 || Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 930 927 914 892 861 822 776 723 664 600 532 461 387 311 235 160 92 37 0 Across ⊥ 930 931 927 919 908 890 868 841 808 769 723 670 598 480 337 215 118 43 0 45° 930 928 920 906 886 860 828 790 747 697 642 581 514 441 347 233 129 45 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 106 97 88 80 73 67 61 57 53 49 46 ⊥ Across ⊥ 755 755 752 746 736 722 704 682 656 624 587 544 486 389 274 175 97 35 0 45° 755 753 747 736 719 698 671 641 606 566 521 471 417 358 281 189 105 37 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 2AC-224T5 Electronic Ballast (2) F24T5HO/835 lamps 1750 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency 85% Test Report: 2AC-224T5.IES LER = FL-93 LPW Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.58 Candela %Fixture 24.9 41.4 76.7 100.0 100.0 Average 0-Deg cd/sm 1872 1772 1627 1376 967 95 78 64 54 46 39 34 30 27 24 22 Average 45-Deg cd/sm 2176 2232 2303 1985 1154 91 78 66 57 49 43 38 34 31 28 26 91 76 63 53 45 39 34 30 27 24 22 Average 90-Deg cd/sm 2399 2578 2502 1838 1092 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 101 92 83 76 69 63 58 54 50 47 44 101 88 76 66 59 52 47 42 38 35 32 101 84 70 59 51 44 39 35 31 28 26 101 81 65 53 45 38 33 29 26 23 21 99 90 81 74 67 61 57 52 49 46 43 99 86 74 65 57 51 46 41 38 35 32 99 82 69 58 50 44 38 34 31 28 25 99 79 64 53 45 38 33 29 26 23 21 20% 50% 50 30 10 30% 50 30 10 50 94 82 71 62 55 49 44 40 37 34 31 90 79 69 60 53 48 43 39 36 33 30 87 76 66 58 51 46 41 38 35 32 29 94 79 67 57 49 43 38 34 30 27 25 94 77 63 52 44 38 33 29 26 23 21 90 77 65 55 48 42 37 33 30 27 25 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 740 1232 2279 2973 2973 %Lamp 21.1 35.2 65.1 85.0 85.0 %Fixture 24.9 41.5 76.7 100.0 100.0 90 74 61 51 43 37 32 29 25 23 21 Average 0-Deg cd/sm 2305 2184 1999 1679 1153 Average 45-Deg cd/sm 2678 2752 2835 2446 1403 10% 30 10 87 74 63 54 47 41 36 32 29 27 24 87 72 60 50 43 37 32 28 25 23 21 0% 0 85 70 58 48 41 35 30 27 24 21 19 Average 90-Deg cd/sm 2955 3173 3086 2257 1340 Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 4/13 ADF051721 2AC ORDERING INFORMATION SAMPLE NUMBER: 2AC-214T5-UNV-EBT1NDIM Rating Blank= Standard NY=New York Rated ATW-SW4= Chicago Rated Width 2=2' Width Series AC=Accord Series Type A=Air (optional) Number of Lamps (Not included) 2=2 Lamp Wattage (Length) 14T5=14W T5 (24") 24T5=24W T5HO (24") Shielding Blank=Frosted Acrylic (standard) SQP=Lens with Square Pattern Insert RDP=Lens with Round Pattern Insert Voltage (1) UNV=Universal Voltage 120-277 Options GL=Single Element Fuse GM=Double Element Fuse Flex=Flex installed EL=Emergency Installed Lamps L5835=T5 Lamp, 3500K L5841=T5 Lamp, 4100K L5835HL=T5 Lamp, 28W, 3500K, 2900 Lumens L5841HL=T5 Lamp, 28W, 4100K, 2900 Lumens (1) (2) NOTES: Products also available in non-US voltages and frequencies for international markets. Step dimming ballast available (3) (4) for 14W T5 lamps only. .90 and 1.15 ballast factor available for 2 or 3 14W T5 lamps only. Step dimming ballast available for 2 or (5) 3 lamp 14WT5 lamps only. 1 lamp step dimming ballast in a normal ballast factor not available. 2 lamp ballast will not operate 1 (6) (7) lamp. 1 lamp ballast in a high ballast factor not available. For a complete listing of Fifthlight Technology products and other solu(8) tions from Cooper Controls, visit www.coopercontrol.com. 0-10V ballast do not include DALI feature. Please select DALI ballast for (9) use with Fifth Light system. Specification grade 0-10V dimming ballast are NEMA premium and CEE listed. They are compatible (10) with low mercury and energy saving lamps. Standard 0-10V ballast not available for 24W T5HO lamps. (11) Specification Grade 0-10V ballast not available for 24W T5HO lamps. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Ballast Type (1) EBT =T5/T5HO Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor=1.0 Packaging U=Unit Pack PALC=Job Pack, in carton Ballast/FactorType EBT N=T5/T5HO Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Normal Ballast Factor=.90 (3) EBT H=T5/T5HO Electronic Program Rapid Start. Total Harmonic Distortion< 10%. High Ballast Factor=1.15 (3), (6) EBT NDIM=T5/T5HO Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming, Normal Ballast Factor=.95-1.0 (4), (5) EBT HDIM=T5/T5HO Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming, High Ballast Factor=1.15 (4) 0-10V Dimming Ballasts (8) 5LTV5 =T5 0-10V Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 5LTVS5 =T5 0-10V Spec Grade Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 (9) 5LTV5H =T5HO 0-10V Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 (10) 5LTVS5H =T5HO 0-10V Spec Grade Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 (9), (11) Fifth Light DALI Ballasts (7) 5LT5 =T5 DALI Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 5LT5H =T5HO DALI Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 Number of Ballasts 1=1 Ballast 2=2 Ballasts ACCESSORIES T3A END E.Q. BRACKET PARTS BAG SHIPPING INFORMATION Catalog No. Wt. 2AC-214T5 2AC-224T5 28 lbs. 28 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 4/13 ADF051721