COOPER LIGHTING - METALUX

advertisement
COOPER LIGHTING - METALUX
D ES C R IPTION
The Accord™ redefines fluorescent lighting by improving on aesthetics,
comfort and energy savings. The Accord™ provides the right amount of
light while eliminating surface shadows commonly found in parabolics.
Therefore, Accord™ increases the comfort level while providing
significant energy savings.
The Accord™ is the ideal solution for offices, schools, hospitals, retail
and other applications.
®
Type
Catalog #
Project
Date
Comments
Prepared by
S PEC IFIC A TION FEA T U R E S
Construction
F in ish
A ir V ented
Housing is die formed of code
gauge, prime cold rolled steel.
Heavy gauge end plates are
securely attached with screws
for strength and rigidity and the
elimination of gaps. Four auxiliary
fixture end suspension points are
provided. Large access plate for
supply connection.
Durable cold rolled steel with
multistage, iron phosphate
pretreatment and white enamel
finish to ensure maximum bonding
and rust inhibition.
Optional air vented model provides
air flow through air slots in the
housing.
Re f le cto rs
Reflector has high reflectance
baked matte white enamel finish
for luminous uniformity.
El e c t r i c a l *
Ballasts are Class “P” and are
positively secured. Rotor-lock
lampholders ensure positive lamp
retention. UL/CUL listed. Suitable
for damp locations.
Sh ie ld in g
Positively retained frosted acrylic
profile lenses provide a soft but
effective distribution of light.
Controls
Fifth Light ballast options are
offered for both 0-10V continuous
dimming and DALI applications.
Combine with energysaving
products like occupancy sensors,
daylighting controls, and lighting
relay panels from Cooper Controls
(www.coopercontrol.com) to
maximize energy savings.
AC
132T8
B al l a s t A c c e s s
1' X 4' RECESSED
T8 LAMP
Ballast can be accessed from below
without tools through hinged door
assembly.
Troffer Series
5-3/8"
[137mm]
11-5/8" [295mm]
MOUNTING D A TA
L A MP CONF IGURA T IONS
7-3/4"
[197mm]
ENERGY DATA
1 LAMP
6-1/4"
[159mm]
Input Watts:
5-3/8"
[137mm]
EB Ballast & STD Lamps @ 277V
132T8 (28)
11-5/8" [295mm]
11-5/8"
[295mm]
Luminaire Efficacy Rating
LER =FL73 LPW
Catalog Number: AC-132
5-13/16"
[148mm]
X=3-1/2"
[90mm]
X
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.29
48" [1217mm]
NOTE: 1' x 4' allows for row mounting
*Reference the lamp/ballast data in
the Technical Section for specific
lamp/ballast requirements.
**Consult Pre Sales Technical
Support.
***See Drywall Frame Kit Accessory
CE IL ING COMP A T A BIL IT Y
G
Grid/Lay-in
Standard
F
Drywall Frame
Kit
Ceiling
Type**
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
G
G or T
G or T
***
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF131791
2014-05-20 13:24:15
AC 1 ' X 4 '
PH OTOM ETR IC S
90˚
75˚
300
60˚
600
45˚
900
0˚
15˚
AC-132
Electronic Ballast
(1) F32W T8 Lamp
3100 Lumens each
Candlepower
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.3 x
mounting height
Efficiency 75.6%
Test Report:
AC-132-UNV-EB81U.IES
30˚
LER = 73.0
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.29
Along II
793
791
780
762
735
702
664
618
568
515
457
398
334
274
210
145
85
32
0
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
45°
793
789
780
766
745
718
688
652
613
567
518
465
397
314
224
143
74
24
0
Across ⊥
793
793
786
775
759
738
714
686
652
614
559
484
389
283
187
115
60
19
0
C o e ffi c i e n t s o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
90
82
75
68
62
57
53
49
45
42
40
90
79
69
60
53
47
43
39
35
32
30
90
76
64
54
47
41
36
32
29
26
24
90
73
59
49
41
36
31
27
24
22
20
88
80
73
66
61
56
51
48
44
41
39
88
77
67
59
52
47
42
38
35
32
29
88
74
63
53
46
40
35
32
28
26
24
88
72
58
49
41
35
31
27
24
22
20
20%
50%
50 30 10
30%
50 30 10
50
84
74
65
57
50
45
41
37
34
31
29
80
71
62
55
49
43
39
36
33
30
28
77
68
60
53
47
42
38
35
32
29
27
84
71
61
52
45
39
35
31
28
25
23
84
69
57
48
41
35
31
27
24
22
20
80
69
59
50
44
39
34
31
28
25
23
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
624
1033
1872
2345
2345
%Lamp
20.1
33.3
60.4
75.6
75.6
%Fixture
26.6
44.0
79.8
100.0
100.0
Average
0-Deg
cd/sm
2351
2240
2093
1808
1185
80
67
56
47
40
35
30
27
24
21
19
Average
45-Deg
cd/sm
2588
2617
2398
1784
889
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
10%
30 10
77
67
57
49
43
38
34
30
27
25
23
77
65
55
46
39
34
30
27
24
21
19
0%
0
76
64
53
44
38
33
28
25
22
20
18
Average
90-Deg
cd/sm
2803
2724
2162
1434
704
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Specifications and
dimensions subject to
change without notice.
ADF131791
2014-05-20 13:24:15
AC 1 ' X 4 '
ORDER ING INFOR M A TION
SAMPLE NUMBER: AC-132-UNV-EB81-U
Rating
Blank=
Standard
ATW-SW4=
Chicago
Rated
Width
Blank=1' Width
Series
AC=Accord Series
Type
A=Air Vented (Optional)
Number of
Lamps
(Not included)
1=1 Lamp
Wattage (Length)
32=32W T8 (48")
Shielding
Blank=Frosted Acrylic
(standard)
SQP=Lens with Square
Pattern Insert
RDP=Lens with Round
Pattern Insert
Voltage (1)
UNV=Universal Voltage
120-277
Options
Emergency
EL=Emergency Installed
Lamps
L8835=T8 Lamp, 17W and 32W, 3500K
L8841=T8 Lamp, 17W and 32W, 4100K
L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens
L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens
Flex
Multiple Configurations Available
(1)
(2)
NOTES: Products also available in non-US voltages and frequencies for international markets. For a complete listing
(3)
of Fifthlight Technology products and other solutions from Cooper Controls, visit www.coopercontrol.com. 0-10V ballast do
(4)
not include DALI feature. Please select DALI ballast for use with Fifth Light system. Specification grade 0-10V dimming ballast
are NEMA premium and CEE listed. They are compatible with low mercury and energy saving lamps.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change
without notice. Consult your Cooper Lighting Representative for availability and ordering information.
Ballast Type
EB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%
EB8 /PLUS= T8 Electronic Instant Start.
High Ballast Factor >1.13.
Total Harmonic Distortion < 20%
ER8 =T8 Electronic Program Start.
Total Harmonic Distortion < 10%
High Performance T8 Ballasts
HB8 L=T8 Electronic Instant Start.
Low Ballast Factor .77
HB8 =T8 Electronic Instant Start.
Ballast Factor .88
HB8 N=T8 Electronic Instant Start.
Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start.
High Ballast Factor 1.15-1.2
HR8 DIM=T8 Electronic Program Start
Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Start.
Low Ballast Factor .77
HR8 =T8 Electronic Program Start.
Ballast Factor .88
HR8 H=T8 Electronic Program Start.
High Ballast Factor 1.15-1.2
Packaging
U=Unit Pack
PALC=Job Pack,
in carton
0-10V Dimming Ballasts (3)
5LTV8 =T8 0-10V Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 0.87
5LTVS8 =T8 0-10V Spec Grade Program Rapid
Start. Total Harmonic Distortion < 10%.
Ballast Factor 0.87 (4)
Fifth Light DALI Ballasts (2)
5LT8 =T8 DALI Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 1.0
Number of Ballasts
1=1 Ballast
2=2 Ballasts
ACCESSORIES
T3A END E.Q. BRACKET PARTS BAG
DF-14-W=1' x 4' Drywall Frame Kit
SH IP P ING D A T A
Catalog No.
AC-132T8
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Specifications and
dimensions subject to
change without notice.
Wt.
22 lbs.
ADF131791
2014-05-20 13:24:15
Download