COOPER LIGHTING - METALUX

advertisement
COOPER LIGHTING - METALUX
Des c r iption
The Metalux Horizon Surface/Suspended Wall Wash Series features
recessed aesthetics and the latest in Energy Efficient Technology. The
clean architectural design incorporates precision-formed aluminum
reflector features that produces efficient, uniform and continuous vertical
wall illumination.
The Horizon Surface/Suspended Wall Wash Series is specifically
designed for effective use in various retail, merchandising and
commercial wall washing environments. Horizon is ideal for retail
displays, showrooms, corridor walls, art lighting and the elimination of
the “Cave Effect” in office lighting applications.
®
Type
Catalog #
Project
Date
Comments
Prepared by
Spe c ific a tion F ea t u r e s
C on s t r u c t i o n
Fin ish
Reflector Optical Assembly
Nominal 4-1/2” deep 10”x4’
housing designed for use with T8
and biaxial lamps. The housing
is constructed of die formed
code gauge prime cold rolled
steel. Housing incorporates
a longitudinal flange for grid
installation or ceiling tile support.
KO’s for continuous row mounting.
Electrostatically applied baked
white polyester powder enamel
finish. Multistage cleaning cycle,
iron phosphate coating with
rust inhibitor. Conveyorized
application and baking timing
accurately controlled at an elevated
temperature.
The internal aluminum reflector
optical assembly incorporates
an upper “Scoop” and lower
“Kick” reflector design. This
design produces uniform even
illumination on vertical surfaces.
Continuous illumination is
maintained to the junction of the
wall and the ceiling. Reflectors
are precision manufactured from
specular low iridescent aluminum
in a computer-controlled operation.
Electrical*
Ballasts are CBM/ETL Class “P” and
are positively secured. Biax models
use 2G11 base lampholders with
double-edge wiping action pressur
lock contacts and lamp support
clips. T8 models use pressurelock lampholders. UL/CUL listed.
Suitable for damp locations.
RWW
132
232
T1BX40
4-5/8"
[118mm]
1' x 4'
R e c e ss e d
Wall Wash
10"
[254mm]
T8 or Biaxial Lamps
10-3/8"
[264mm]
Vertical Illumination
Luminaire
Mo unting D a ta
Ballast Plate
X X=1-1/2"
[38mm]
Access Plate
7/8" K.O. (2)
[22mm]
10-11/16"
[272mm]
8-13/16"
[224mm]
X X=1-1/2"
[38mm]
4-5/8"
[118mm]
35"
[889mm]
10-3/8"
[264mm]
23-3/8"
[594mm]
47-3/8"
[1203mm]
15-1/8"
[384mm]
1-1/4"
[32mm]
1-1/4"
[32mm]
4-5/8"
[118mm]
10"
[254mm]
10-3/8"
[264mm]
16-1/8"
[410mm]
1"
[25mm]
Input Watts:
Electronic Ballast & STD Lamps
132 (32)
232 (58)
T1BX40 (71)
T1BX50 (106)
T1BX55 (117)
ES Ballast & STD Lamps
132 (30)
232 (55)
1BX50 (54 Watts)
T2BX50 (106 Watts)
4-5/8"
[118mm]
1"
[25mm]
Energy Data
10"
[254mm]
10-3/8"
[264mm]
STD Ballast & STD Lamps
T1BX40 (77)
Ins ta lla tion D a ta
G
Grid/Lay-in
Standard
T
Slot Grid
T
Chicago Metallic
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
2-1/2" [64mm]
Range for bracket
height adj.
2-1/2" [64mm]
Range for bracket
height adj.
2-1/2" [64mm]
Range for bracket
height adj.
Safe and convenient means of
disconnecting power.
ADF020635
2014-03-31 09:06:37
RWW
Ph otom etr ic s
Candela
RWW-232MI
Electronic Ballast
F32T8/835 Lamps
2800 Lumens
Efficiency 69.7%
Test Report:
RWW232MI.IES
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
0-180
Lumens
959
1640
2973
3902
3902
%Lamp
17.1
29.3
53.1
69.7
69.7
%Fixture
24.6
42.0
76.2
100.0
100.0
Along II
45°
Across ⊥
943
1435
2087
2601
2656
2595
2479
2332
2136
1817
1667
1554
1416
1197
938
663
422
184
0
943
1319
1803
2227
2529
2556
2436
2317
2155
1961
1737
1442
1258
1111
912
657
406
166
0
943
940
930
910
880
839
791
736
675
607
532
454
379
305
234
166
110
59
0
Zone
0-30
0-40
0-60
0-90
0-180
83
73
63
56
49
43
39
35
31
28
25
83
70
59
50
43
37
32
28
25
22
19
83
67
55
46
39
32
28
24
21
18
15
81
74
67
61
56
51
47
43
40
36
34
81
71
62
55
49
43
38
34
30
27
25
Lumens
1095
1998
3648
5031
5031
%Lamp
17.4
31.7
57.9
79.9
79.9
%Fixture
21.8
39.7
72.5
100.0
100.0
Along II
419
931
2342
3471
3766
3847
3629
3145
2378
2092
2014
2006
1961
1899
1631
1099
675
405
0
45°
419
826
1586
2733
3408
3601
3573
3500
3154
2635
1960
1721
1593
1514
1382
1146
653
326
0
Across ⊥
419
423
419
412
403
389
371
349
328
306
283
260
236
219
209
203
191
99
0
C o e f fi c i e n t s o f U t i l i z a t i o n
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
83
76
69
63
58
53
48
44
41
37
35
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Zonal Lumen Summary
C o e f fi c i e n t s o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Candela
RWW-T1BX40
Electronic Ballast
F40BX/835/RS Lamps
3150 Lumens
Efficiency 79.9%
Test Report:
RWWT1BX40MI.IES
81
68
58
50
43
37
32
28
25
22
19
81
66
54
45
38
32
28
24
21
18
15
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
20%
50%
50 30 10
30%
50 30 10
50
77
68
60
53
47
41
37
33
30
26
24
74
65
57
51
45
40
36
32
29
26
23
71
63
55
49
44
39
35
31
28
25
23
77
66
56
48
42
36
31
28
24
21
19
77
64
53
45
38
32
27
24
20
18
15
7'
8'
74
64
54
47
41
35
31
27
24
21
19
74
62
52
44
37
32
27
24
20
17
15
10%
30 10
71
61
53
46
40
34
30
27
23
21
18
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
0%
0
71
60
51
43
37
31
27
23
20
17
15
70
59
49
42
35
30
26
22
19
16
14
95
86
78
71
65
59
54
50
45
42
39
95
82
71
62
55
48
43
38
34
30
27
6' 7'
8'
95
79
66
56
48
41
35
31
27
23
20
95
76
61
50
42
35
30
26
22
18
16
93
84
76
69
63
57
52
48
44
40
37
93
81
70
61
54
47
42
37
33
30
27
93
77
65
55
47
40
35
30
26
23
20
20%
93
74
60
50
42
35
30
25
22
18
16
50%
50 30 10
30%
50 30 10
50
89
77
67
59
52
45
40
36
32
29
26
85
74
64
57
50
44
39
35
31
28
25
81
71
62
54
48
42
38
34
30
27
24
89
74
63
53
46
39
34
30
26
23
20
89
72
59
49
41
34
29
25
22
18
16
85
72
61
52
45
38
33
29
26
22
20
85
70
57
48
41
34
29
25
21
18
16
10%
30 10
81
69
59
51
44
38
33
29
25
22
19
0%
0
81
68
56
47
40
34
29
25
21
18
16
80
66
54
45
38
32
27
23
20
16
14
Wal l Illum ina nc e
Individual Unit*
0'
Ceiling
8'
7'
6'
5'
4'
3'
2'
1'
Floor
65
82
64
50
35
25
18
14
1'
59
74
59
46
33
24
18
14
2'
42
56
47
38
29
21
16
13
3'
4'
5'
24 13
35 20
33 21
28 19
23 17
18 14
14 11
11 10
7
11
13
13
12
10
9
8
6'
4
7
8
8
8
8
7
6
Continuous Row*
Multiple Units*
2
4
5
6
6
6
5
5
2
3
3
4
4
4
4
4
0'
1'
2'
3'
4'
5'
0'
8'
4'
Ceiling
8'
7'
6'
5'
4'
3'
2'
1'
Floor
69
88
72
59
45
34
28
23
63
81
68
56
43
34
27
23
48
65
58
50
40
33
27
23
33
49
48
44
37
31
26
23
27
42
44
42
36
31
26
23
33
49
48
44
37
31
26
23
48
65
58
50
40
33
27
23
63
81
68
56
43
34
27
23
Ceiling
8'
7'
6'
5'
4'
3'
2'
1'
Floor
69
88
72
59
45
34
28
23
1'
2'
3'
4'
5'
6'
7'
8'
95 95 95 95 95 95 95 95 95
128 129 129 129 129 129 129 129 129
113 113 114 114 114 114 114 114 115
96 97 98 98 99 99 99 99 99
76 78 78 79 79 79 80 79 79
60 62 62 63 63 63 64 64 64
49 50 51 51 52 52 52 52 52
41 43 43 44 44 44 45 45 45
*Units located 3’ from wall. Data provided for RWW-232MI Unit
Or d er ing I nfor m a tion
S A M P L E N U M B E R : R W W - 2 3 2 M I - 1 2 0 V- E B 8 1 - U
Series
RWW=Recessed
Wall Wash
Number
of Lamps
(Not included)
1=1 Lamp
2=2 Lamp
T1=2' x 4' Fixture with one
Biax Lamp at each end
Wattage (Length)
32=32W T8 (48")
BX40=40W Biax (24") (3) (4)
BX50=50W Biax (24") (3) (4)
BX55=55W Biax (24") (3) (4)
Louver Finish
I=Semi-Specular/Haze
(Low Iridescent)
Standard
MI=Specular/Mirrored
(Low Iridescent)
Voltage (1)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal Voltage
120-277 (2)
Options
GL=Single Element Fuse
GM=Double Element Fuse
EL=Emergency installed
Ballast Type
Blank=Standard Magnetic Ballast (40W Biax only)
EB8 =T8 Electronic Start.
Total Harmonic Distortion < 10%
EB8 /PLUS= T8 Electronic Start.
Total Harmonic Distortion < 10%.
High Ballast Factor > 1.15.
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
EB5 =T5 Biax Electronic Instant Start
Total Harmonic Distortion < 20% (5)
TEB5 =T5 Biax Electronic Instant Start
Total Harmonic Distortion < 10% (5)
ER5 =T5 Biax Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
Options
RLS=Rotor-Lock
Socket
(T8 Lamps Only)
Packaging
U=Unit Pack
PALC=Job
Pack, in carton
Accessories
TBW2=Thin White Baffle Accessory (2' Fixture) (2)
TBW4=Thin White Baffle Accessory (4' Fixture) (2)
CAL2=Clear Acrylic Lens (2' Fixture)
CAL4=Clear Acrylic Lens (4' Fixture)
DF-104-W=4' Version Drywall Frame Kit
Number of Ballasts
1=1 Ballast
2=2 Ballasts
NOTES: (1) Products also available in non-US voltages and frequencies for international markets.
(2)
UNV available in T5 and T8 linear only. Not available when specifying emergencies, voltage
must be specific. (3) Electronic ballast only. (4) Biax only available in 1 lamp cross section. (5) Not
available in UNV voltages. Must specify voltage.
Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
SHIPPING DATA
Catalog No.
Wt.
RWW-13217.5
RWW-23217.5
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Specifications and
dimensions subject to
change without notice.
ADF020635
2014-03-31 09:06:37
Download