COOPER LIGHTING - METALUX Des c r iption The Metalux Horizon Recessed Wall Wash Series features recessed aesthetics and the latest in Energy Efficient Technology. The clean architectural design incorporates precision-formed aluminum reflector features that produces efficient, uniform and continuous vertical wall illumination. The Horizon Recessed Wall Wash Series is specifically designed for effective use in various retail, merchandising and commercial wall washing environments. Horizon is ideal for retail displays, showrooms, corridor walls, art lighting and the elimination of the “Cave Effect” in office lighting applications. ® Type Catalog # Project Date Comments Prepared by Spe c ific a tion F ea t u r e s C on s t r u c t i o n Fin ish Reflector Optical Assembly Nominal 4-1/2” deep 10” x 2’ housing designed for use with 40, 50 and 55 watt biaxial 17W T8 lamps. The housing is constructed of die formed code gauge prime cold rolled steel. Housing incorporates a longitudinal flange for grid installation or ceiling tile support. KO’s for continuous row mounting. Electrostatically applied baked white polyester powder enamel finish. Multistage cleaning cycle, iron phosphate coating with rust inhibitor. Conveyorized application and baking timing accurately controlled an eleat vated temperature. The internal aluminum reflector optical assembly incorporates an upper “Scoop” and lower “Kick” reflector design. This design produces uniform even illumination on vertical surfaces. Continuous illumination is maintained to the junction of the wall and the ceiling. Reflectors are precision manufactured from specular low iridescent aluminum in a computer-controlled operation. Electrical* RWW 1BX40 117 217 Ballasts are CBM/ETL Class “P” and are positively secured. Biax models use 2G11 base lampholders with double-edge wiping action pressure lock contacts and lamp support clips. T8 models use pressure-lock lampholders. UL/CUL listed. Suitable for damp locations. 1' x 2' R e c e ss e d W a l l W a s h Biaxial or T8 Lamps Vertical Illumination Luminaire [118mm] [254mm] [264mm] Energy Data Mo unting D a ta X [54mm] [32mm] [32mm] [118mm] [264mm] [254mm] [279mm] [25mm] [25mm] [254mm] [264mm] [264mm] [594mm] [118mm] Input Watts: Electronic Ballast & STD Lamps 1BX40 (43) 1BX50 (54) 1BX55 (60) 117 (19) 217 (34) STD Ballast & STD Lamps 1BX40 (48) 117 (23) 217 (45) ES Ballast & STD Lamps 117 (23) 217 (45) Ins ta lla tion D a ta G Grid/Lay-in Standard T Slot Grid T Chicago Metallic *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF020637 2014-03-31 09:05:35 RWW Ph otom etr ic s RWW-1BX40MI Electronic Ballast F14T5/835 Lamps 3150 Lumens Efficiency 80.4% Test Report #167P117 || Lumens 526 979 1835 2534 2534 %Lamp 16.7 31.1 58.3 80.4 80.4 Along II 196 430 1051 1671 1877 1898 1844 1675 1290 1148 1122 1104 1074 1040 882 496 271 242 0 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 %Fixture 20.7 38.6 72.4 100.0 100.0 45° 196 376 674 1245 1637 1753 1772 1713 1624 1380 1056 920 851 798 728 591 261 157 0 Across ⊥ 196 197 195 192 187 182 174 164 154 145 133 121 109 98 93 88 71 24 0 || 96 83 72 63 55 48 43 38 34 30 27 96 79 66 56 48 41 35 31 26 23 20 96 76 61 51 42 35 30 25 21 18 16 94 85 77 70 63 57 52 48 44 40 37 94 81 70 62 54 47 42 37 33 29 27 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Zone 0-30 0-40 0-60 0-90 0-180 Lumens 451 757 1337 1739 1739 %Lamp 17.3 29.1 51.4 66.9 66.9 %Fixture 25.9 43.6 76.9 100.0 100.0 Along II 461 717 1023 1212 1199 1170 1119 1033 913 799 734 685 637 547 436 314 211 107 0 45° 461 674 864 1078 1177 1140 1091 1029 950 853 721 613 532 472 399 295 184 86 0 Across ⊥ 461 464 458 447 429 406 378 351 321 286 247 205 163 120 79 42 15 3 0 C o e f fi c i e n t s o f U t i l i z a t i o n Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 96 87 79 72 65 59 54 50 45 42 38 Candela Zonal Lumen Summary C o e f fi c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 RWW-217MI Electronic Ballast F17T8/835 Lamps 1400 Lumens Efficiency 66.9% Test Report #167P116 Candlepower 94 78 65 55 47 40 35 30 26 23 20 20% 94 75 61 50 42 35 30 25 21 18 16 50% 50 30 10 30% 50 30 10 50 89 78 67 59 52 46 40 36 32 29 26 86 75 65 57 50 44 39 35 31 28 25 82 72 62 55 48 42 38 34 30 27 24 89 75 63 54 46 39 34 30 26 22 20 89 73 59 49 41 34 29 25 21 18 15 86 72 61 52 45 38 33 29 25 22 19 86 70 58 48 41 34 29 25 21 18 15 10% 30 10 82 70 59 51 44 37 33 29 25 22 19 0% 0 82 68 57 48 40 34 29 25 21 18 15 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 80 67 55 46 38 32 27 23 19 16 14 80 73 67 61 56 51 47 43 40 36 34 80 70 61 54 48 42 38 34 30 27 25 80 67 57 49 42 36 32 28 24 21 19 80 65 53 44 38 32 27 24 20 18 15 78 71 65 59 54 49 45 42 38 35 33 78 68 60 53 47 41 37 33 30 27 24 78 66 56 48 42 36 31 28 24 21 19 20% 78 64 52 44 37 32 27 24 20 18 15 50% 50 30 10 30% 50 30 10 50 74 66 58 51 45 40 36 32 29 26 24 71 63 55 49 44 39 35 31 28 25 23 68 61 53 47 42 37 34 30 27 24 22 74 63 54 47 41 35 31 27 24 21 19 74 62 51 43 37 31 27 23 20 17 15 71 61 53 46 40 34 30 27 23 21 18 71 60 50 43 36 31 27 23 20 17 15 10% 30 10 68 59 51 44 39 34 30 26 23 20 18 68 58 49 42 36 31 27 23 20 17 15 0% 0 67 56 47 40 34 29 25 22 19 16 14 Wal l Illum ina nc e Individual Unit* 0' Ceiling 8' 7' 6' 5' 4' 3' 2' 1' Floor 57 54 36 29 22 15 11 8 1' 47 46 32 27 21 15 10 8 2' 3' 27 31 24 21 17 13 9 7 4' 5' 13 6 17 10 15 10 14 9 13 9 10 8 8 6 6 5 3 5 6 6 6 5 5 4 Continuous Row* Multiple Units* 6' 7' 2 3 4 4 4 4 4 3 1 2 2 3 3 3 3 3 0' 8' 1 1 1 2 2 2 2 2 *Units located 3’ from wall. Data provided for RWW-232MI Unit Ceiling 8' 7' 6' 5' 4' 3' 2' 1' Floor 1' 2' 3' 4' 0' 1' 2' 4' 72 77 59 52 44 34 27 22 66 73 58 52 45 35 28 23 60 69 57 53 45 36 28 24 3' 4' 5' 6' 66 73 58 53 45 36 29 24 72 77 60 53 45 36 29 24 62 62 44 39 32 24 19 16 52 55 42 37 31 24 19 16 35 43 37 34 30 24 19 16 28 37 33 32 29 24 19 16 35 43 36 34 30 24 20 16 52 55 42 37 31 25 20 17 0' 1' 2' 3' 4' 5' 6' 7' 8' 131 146 115 104 89 70 55 46 131 146 116 105 90 71 56 47 131 146 116 105 91 72 57 48 131 147 116 105 91 72 57 48 131 147 116 106 91 72 58 48 131 147 116 106 91 72 58 49 131 147 116 106 91 72 58 49 131 147 116 106 91 72 58 49 131 147 116 106 91 72 58 49 6' 62 62 44 39 32 25 20 16 Ceiling 8' 7' 6' 5' 4' 3' 2' 1' Floor Fixture Location: 36" from center of luminaire to wall. Mounting Height: 9ft. Order ing I nfor m a tion S A M P L E N U M B E R : R W W - 1 B X 4 0 M I - 1 2 0 V- E B 5 1 - U Series RWW=Recessed Wall Wash Number of Lamps (Not included) 1=1- Lamp 2=2- Lamp Wattage (Length) 17=17W T8 (24") BX40=40W Biax (24") (3) (4) BX50=50W Biax (24") (3) (4) BX55=55W Biax (24") (3) (4) Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard MI=Specular/Mirrored (Low Iridescent) Voltage (1) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (2) Options GL=Single Element Fuse GM=Double Element Fuse EL=Emergency installed Ballast Type Blank=Standard Magnetic Ballast (40W Biax only) EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10%. High Ballast Factor > 1.15. ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% EB5 =T5 Biax Electronic Instant Start Total Harmonic Distortion < 20% (5) TEB5 =T5 Biax Electronic Instant Start Total Harmonic Distortion < 10% (5) ER5 =T5 Biax Electronic Program Rapid Start. Total Harmonic Distortion < 10% Options RLS=Rotor-Lock Socket (T8 Lamps Only) Accessories TBW2=Thin White Baffle Accessory (2' Fixture) (2) TBW4=Thin White Baffle Accessory (4' Fixture) (2) CAL2=Clear Acrylic Lens (2' Fixture) CAL4=Clear Acrylic Lens (4' Fixture) DF-102-W=2' Version Drywall Frame Kit Number of Ballasts 1=1 Ballast 2=2 Ballasts NOTES: (1) Products also available in non-US voltages and frequencies for international markets. (2) UNV available in T5 and T8 linear only. Not available when specifying emergencies, voltage must be specific. (3) Electronic ballast only. (4) Biax only available in 1 lamp cross section. (5) Not available in UNV voltages. Must specify voltage. SHIPPING DATA Catalog No. Wt. RWW-1BX4011.0 RWW-11711.0 RWW-21711.0 Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Packaging U=Unit Pack PALC=Job Pack, in carton Eaton’s Cooper Lighting Business 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com Specifications and dimensions subject to change without notice. ADF020637 2014-03-31 09:05:35