Fail-Safe

advertisement
Fail-Safe
D ES C R IPTION
The fully enclosed MNAE offers ambient and/or exam illumination,
dimmable to the appropriate illumination levels. The small aperture
MNAE is flush to the ceiling line, enabling quick, easy, and effective
wipe-down. Separately switched ambient and exam functions provide
flexibility to accommodate the many necessary activities performed
in the patient room. Specify the nightlight for an additional function.
Typically used in pairs, along both sides of the bed, the MNAE offers
glare and shadow free illumination. Specify the LED reading and/or chart
light for an additional function in the patient room.
Type
Catalog #
Project
Date
Comments
Prepared by
SP EC IFIC A TION FEA T U R E S
Ap p l i c a t i o n
L e ns
Driver
Designed for use in healthcare
facilities. Ideal for patient rooms,
exam rooms and recovery areas,
where exam, ambient iillumination
are required.
0.080” thick frosted acrylic lens.
Electronic driver. 0-10V dimming
standard.
D oor
Housing
Inset die-formed steel, painted antimicrobial powder coat matte white.
Two stainless steel aircraft cables
attach door to housing.
Die-formed steel, white powder
coat finish.
L ED
Mounting
Recessed grid. For flange
applications, specify the DFCL
drywall framing kit.
LEDs available in 3000K, 3500K,
4000K and 5000K. Projected life
is 50,000 hours at 70% lumen
maintenance.
R atin g s
ETL listed for damp locations. Wet
location under covered ceiling,
available. Non-IC rated. One
thermal protector per circuit.
R eading /Ch art Lig h t
MNAE LED
Adjustable 7.5W MR16 LED, GU5.3
base. Available in 10°, 25°, 36°
beam angle. 2700K and 3000K
available. 95 CRI minimum.
8" Width
LD4 LED
Healthcare
Re fl e c tor
Fin i s h
Housing and internal components
are electrostatically applied, white
powder coat finish. Door frame is
anti-microbial matte white finish.
Die formed aluminum white paint
finish.
5 FUNCTION
Exam
Ambient
Night Light
Reading Light
Chart Light
Used in Pairs
Adjacent to Bed
5-1/8" [131mm]
5"
[127mm]
AMBIENT
LINEAR
NIGHT LIGHT
EXAM
Illumination Level
4' Ambient
7-3/4" [197mm]
4' Exam
Input Delivered
Watts Lumens
LO
25
1925
STD
35
2560
HI
45
3140
LO
25
1840
STD
35
2450
HI
45
2970
RATINGS
ETL listed (Standard)
Anti-microbial (Standard)
Wet location (Optional)
Non-IC
ADC142662
2016-04-26 09:05:44
M NAE LE D
ORDERIN G IN F O R M A T I O N
SAMPLE NUMBER (single unit): MNAE-G-48-LD4-HI/HI-35-89DA-ALW-277-EDC2-SCL/L
MNAE
LD4
Product Family
MNAE=Medical
Narrow
Ambient/
Exam1
Illumination Level,
Ambient
STD=Standard
LO=Low
HI=Hig
Ceiling 2
G=NEMA Type
G System
Illumination Level,
Exam
STD=Standard
LO=Low
HI=High
Length 9
36=36"
48=48"
54=54"
60=60"
Diffuser
89DA=0.80" Thick,
Highly Transmissive
Diffuse Acrylic Lens
EDC2=Electronic Driver 0-10V Non-Dimming,
Dual Circuit
EDD2=Electronic Driver 0-10V Dimming, 10%,
Dual Circuit
ED1D2=Electronic Driver 0-10V Dimming, 1%,
Dual Circuit
Door Frame
CRSW=Fabricated Steel,
Anti-microbial Matte White
Paint Finish, Inset
ALW=Fabricated Aluminum
Anti-microbial Matte
White Paint
Color Temperature
30=3000K
35=3500K
40=4000K
50=5000K
LD4=Linear LED Version, 4.0
Driver 10
Options
LVCP=Low Voltage Relay, 2 Load 8
LLNL30=Linear LED Night Light, 600 Delivered Lumens,
3000K, Dimmable
LLNL35=Linear LED Night Light, 600 Delivered Lumens,
3500K, Dimmable
LLNL40=Linear LED Night Light, 600 Delivered Lumens,
4000K, Dimmable
LLNLA=Linear LED Night Light, Amber, Dimmable
GLR=Fuse and Holder
EL7W=Emergency Battery Pack, 7W Output
EL10W=Emergency Battery Pack, 10W Output 4
EL14W=Emergency Battery Pack, 14W Output
ALH=Aluminum Housing
WL=Wet location under covered ceiling
IP66=IP66 rating
NSF=NSF2 listed (non-food, splash zone)
Voltage
120V
277V
Notes:
1 Fixture ordered as single unit. Typically used in pairs; order (2) fixtures.
2 For flange applications, specify the DFCL dry wall framing kit (see below ordering info).
3 Voltage dimming leads connected and presented at wiring access point.
4 Available LO and STD illumination levels. HI not available. Specify Voltage.
5 See below for orientation.
6 For LED reading light and chart light, specify both the SCL_ and SRL_ on fixture line item
7 MR16 LED lamps ordered on seperate line item.
8 Default load connection is to ambient and exam.
9 See configuration chart below for nominal lengths.
10 Linear LED portion of Luminaire defaults to 2 circuits, (1 Ambient, 1 Exam).
night light, reading light, chart light, default to single circuit each.
11 SCL_ and SRL_ are not available on 36” length luminaire.
SCL/L=LED Chart Light, L/H 5,6,7,11
SCL/R=LED Chart Light, R/H 5,6,7,11
SRL/L=LED Reading Light, L/H 5,6,7,11
SRL/R=LED Reading Light, R/H 5,6,7,11
LED Reading and Chart Light: Catalog # Logic
SRL/R
or
SCL/R
SRL/L
or
SCL/L
SCL/L
SRL/L
48"
or
54"
48"
or
54"
8"
exam
Bed
54"
or
60"
8"
ambient
ambient
SCL/R
SRL/R
order as
SCL/SRL/L
Bed
8"
exam
exam
54"
or
60"
order as
SCL/SRL/R
8"
ambient
ambient
exam
Accessories
DFCL0836W-U= Drywall Framing Kit, Cleanroom, 8"x 36"
DFCL0836AMW-U= Drywall Framing Kit, Cleanroom, 8"x 36",
Anti-Microbial Matte White Paint
DFCL0848W-U
DFCL0848AMW-U
DFCL0854W-U
DFCL0854AMW-U
DFCL0860W-U
DFCL0860AMW-U
LED Night Light and Chart Light - MR16 LED Lamps
CONF IGURA T ION CH A RT
Nominal
8" x 48"
7
Nominal
8" x 48"
Nominal
8" x 54"
Nominal
8" x 54"
Nominal
8" x 60"
Nominal
8" x 36"
Example: SMR16LED53/7/27/9/36
Lamp
SMR16LED53
Fail-Safe MR16
LED, GU5.3
Base
Wattage
Color Temp
7=7.5W
27=2700K
30=3000K
CRI
9= 95
Beam Angle
10= 10°
25= 25°
36= 36°
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
ADC142662
2016-04-26 09:05:44
Download