Specification grade 32 Watt triple tube compact fluorescent
fixture rated for direct contact with insulation, for use in wet
locations. The AIRTITE™ housing prevents airflow between
attic and living areas. Veined Italian dropped glass diffuser
provides a soft smooth illumination pattern.
®
Type
Catalog #
Project
Date
Comments
Prepared By
S P E C I F I C AT I O N F E AT U R E S
Reflector/Lens
High purity 0.040° thick machine-spun
aluminum upper reflector with white
powdercoat finish. Etched satin glass
obscures lamp image.
Attachment
Positive torsion springs pull glass
tight to ceiling. Gasket is a closed cell
foam.
Lamp Socket
4 pin Gx24 (q-3) + (q-4) base for
26/32W PLT, TBX and TTT lamps.
Fatigue free stainless steel spring
ensures positive lamp retention. Fixed
socket height ensures consistent lamp
position.
Electronic Ballast
Thermally protected, current
controlled rapid start 120VAC Input
ballast produces full light output and
rated lamp life. Provides flicker free
and noise free operation and starting.
Meets stringent FCC requirements for
EMI/RFI consumer limits.
Lamp
Generic Compact Fluorescent Lamp
Designations (by others)
• CFTR32W/GX24q 2700K
• CFTR32W/GX24q 3000K
• CFTR26W/GX24q 2700K
• CFTR26W/GX24q 3000K
12,000 hour rated average life.
82 CRI rated lamps provide excellent
color and high visual comfort. Color
temperature (warm to cool) options
offer 2700K warm or 3000K medium
warm incandescent-like light.
Frame/Housing
Hot dipped galvanized 20 gauge steel
frame with built in 1/2 inch plaster
lip. Gunsights allow for consistent
alignment. Aluminum .032 thick
housing allows for heat dissipation
and reduces weight.
Bar Hangers
No Flex® bar hangers with positive
locking, for use with wood,
engineered wood and steel frame
joists spaced up to 24" O.C. ship with
platform. Integralnail and locator lip
provide consistent installation height.
Codes
Thermally protected, IP labeled for
use in direct contact with insulation.
Compliance
• State of California Title 24
• Washington State Energy Code
• New York State Energy Conservation
Construction Code
• International Energy Conservation Code
Labels
UL and cUL listed, standard wet label,
IBEW union made.
P532ICAT
E5LUNA
26/32W TTT
Compact Fluorescent
5-Inch Dropped Lens Showerlight
Junction Box
18 cubic inches, listed for 4 #12
AWG or 6 #14 AWG 90° C additional
feed through conductors, has
(6) 1/2 inch pryouts.
9"
[229mm]
15-3/4"
[401mm]
7-7/8"
[201mm]
10"
[254mm]
Ceiling Cutout 6-1/6" [159mm]
ENERGY DATA
2-1/4"
[54mm]
EMI/RFI Emissions FCC Part 18 Consumer Limits
Input Frequency 50/60 Hz
Power Factor > 0.98
THD < 10%
Input Voltage 120V
26W
6-1/4"
[159mm]
7-1/4"
[184mm]
32W
Input Power
29W
Input Current
.24A
Input Power
36W
Input Current
0.306A
O R D E R I N G I N F O R M AT I O N : C o m p l e t e l u m i n a i r e c o n s i s t s o f a h o u s i n g p l a t f o r m a n d o p t i c a l e l e m e n t .
Example: P532ICAT + E5LUNA
P l a t fo rm
Optical Element
P532ICAT
E5LUNA
P532ICAT =5" Airtight IC rated
housing with electronic ballast
120V input
A c c e s s o ri e s
E5LUNA = 5" Dropped PLE5 = Plaster Lip Extension for Max
Lens Showerlight
2" Thick Ceiling
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADI041417
2012-03-22
IRIS
P H OTO M E T R I C S ®
P 5 3 2 I C AT E 5 L U N A
Photometric Results
Candlepower Distribution
Efficiency = 35.9%
Cone of Light
Candelas
Downlight
Test No. H36081
Vertical
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
48
59
84
114
144
173
196
211
218
219
219
Platform = P532ICAT
Element = E5LUNA
Lumens = 2400
Lamp = 32W PLT
32TTT
D
FC
Beam
Diameter
4'6"
11
6'0"
5'6"
7
7'0"
6'6"
5
8'6"
8'0"
3
10'6"
10'0"
2
13'0"
12'0"
2
15'5"
Zonal Lumens Summary
Zone
Lumens % Lamp % Luminaire
0-30
180
7.5
20.8
0-40
302
12.6
35.0
0-60
565
23.5
65.5
0-90
832
34.7
96.4
90-180
31
1.3
3.6
0-180
863
35.9
100.0
0˚
Single Fixture 2'0" Distance From Wall
DD
1
2
3
4
5
6
7
8
9
10
21
15
8
5
3
2
1
1
1
0
1'
2'
3'
4'
15
12
7
4
3
2
1
1
1
0
7
7
5
3
2
1
1
1
1
0
3
4
3
2
2
1
1
1
0
0
2
2
2
2
1
1
1
1
0
0
Coefficients of Utilization
Ceiling
Reflectance
Wall
Reflectance
RCR
0
1
2
3
4
5
6
7
8
9
10
80%
70%
50%
30%
0%
70
50
30
10
50
10
50
10
50
10
0
43
38
34
31
29
26
24
22
20
19
18
43
36
31
27
24
21
19
17
15
14
13
43
34
28
24
21
18
16
14
12
11
10
43
32
26
21
18
15
13
11
10
9
8
41
35
30
26
23
21
19
17
15
14
12
41
32
26
21
18
15
13
11
10
9
8
39
33
29
25
22
20
18
16
14
13
12
39
31
25
21
18
15
13
11
10
8
7
37
32
27
24
21
19
17
15
14
13
11
37
29
24
20
17
15
13
11
10
8
7
35
27
22
19
16
14
12
10
9
8
7
N OT E S A N D F O R M U L AS P 5 3 2 I C AT E 5 L U N A
Cone of Light:
• Beam diameter is at 50% of maximum footcandles, rounded to the nearest half-foot.
• Footcandle values are initial. Apply appropriate light loss factors where neccessary.
Wall Illumination:
• Illuminance values are cosine corrected initial values with no contribution
from inter reflections from other room surfaces. Total illumination may
increase from contributions from other surfaces.
• DD = Distance Down from Ceiling
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADI041417