INSTALLATION INSTRUCTIONS V90087 REV D Avoid Fire or Electric Shock QUIET CEILING SQUARE REMODEL QCT905 AND QCM514 BASED SERIES Page 1 of 2 THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. *Installation Instructions for qualified electricians only. *Install per National Electrical Code and local regulations. *Read Installation Instructions completely before installation. *Failure to follow Installation Instructions may void warranties. Above Ceiling Clearance Fixture Housing Cover J-Box J-Box Door Fixture Knockouts Insulation Detector Ceiling Cutout 14.29" x 7.38" 5.39 Dimension measure from below ceiling to top of fixture Ceiling Wing nut Rotational Clamp Bracket(Folded) Figure 1 Pre-Installation Preparation: 1. 2. Perforated Mudding Frame Check for Above Ceiling Clearance of 5.39. See Fig.1. Make 14.29" x 7.38" Cutout in Ceiling.See Fig.1. 9. Electrical Connection: 3. Turn OFF Electrical service. 4. All appropriate electrical "rough" wiring should be completed. 5. Remove J-Box door with provided wing nut.See Fig.2.Connect wiring inside J-Box to Existing Service through knockouts provided.Open Fixture Housing Cover while wiring for ease of connection.See Fig.2. 6. Figure 2 Holding Fixture firm to ceiling surface,drive the four (4) #8 X 3" Set Screws (See Fig.5.) located on the underside of Perforated Mudding Frame(See Fig 5) clockwide to rotate and lock the Rotational Clamps Brackets to ceiling.DO NOT over tighten the screws or rotational clamp Brackets.Over tightening may crack ceiling material. Optional: Install additional drywall/zip screws into perforated Mudding Frame to guarantee flatness Mudd-In. 10. Tape and Mudd Perforated Mudding Frame until sufficiently smooth. Folded Rotational Clamp Bracket Reattach J-Box door to Housing with wing nut and close the fixture housing cover. Unfolded Rotational clamp Bracket Note: Single circuit cable only and/or single fixture with next jumper.Wire Single fixture or wire through with second cable(to next fixture) in J-Box. Installation of Housing: 7. Fold four(4) rotational Clamp brackets tight against Fixture (See Fig.3.) making sure Brackets are in upper most(highest) threaded position(see fig.4) to accommodate largest ceiling thickness. 8. Carefully insert wired fixture through ceiling cutout into available ceiling area avoiding all insulation and combustible surface by 3" all around.See Fig.1. Perforated Mudding Frame # 8 Set Screw Figure 3 (View From Below Ceiling, Hidden Lines shown) INSTALLATION INSTRUCTIONS V90087 REV D Avoid Fire or Electric Shock QUIET CEILING SQUARE REMODEL QCT905 AND QCM514 BASED SERIES Page 2 of 2 THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. *Installation Instructions for qualified electricians only. *Install per National Electrical Code and local regulations. *Read Installation Instructions completely before installation. *Failure to follow Installation Instructions may void warranties. J-Box Door Trim Installation: Fixture Rotational Bracket Clamp # 8 Set Screw Ceiling Figure 4 Rotational Clamp Bracket Bracket Fixture Safety Cable Ceiling # 8 Set Screw Trim Mechanism Ball Detent Catch Figure 5 11. Connect Safety Cable attached to Trim to Fixture by inserting Safety Cable through opening in Fixture and inserting Snap Hook (See Fig. 5) on end of Safety Cable into hole in Bracket attached to inside of fixture. 12. Install Trim Mechanism into fixrue by pressing firmly to seat ball detent catches. See Fig.5.