Metalux D ES C R IPTION The Paralux IV Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a 4" precision cell louver into a 6-3/4" deep para-contoured fixture housing. This combination creates a high comfort parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The high comfort luminaire is designed to provide a superior visual environment plus the higher shielding louver angle offers excellent cut-off for today‘s lighting requirements. The Paralux IV series is an excellent choice for commercial spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n 6-3/4" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Contoured ballast/ wireway cover easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates, securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have labor saving integral Grid-Lock feature for safety and convenience. Housing features enable fixture to be converted from Grid to T-option or vice versa in the field.* H inging/Latching Positive cam action spring loaded, self locking, black steel latches. Safety lock T-hinges allow hinging and latching either side. E le ctrica l* * Ballast are CBM/ETL Class "P" and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Louver Die formed of semi-specular, vertical grain, aluminum. Finish is anodic oxide coating. Accurate precision parabolic cells are held in place with interlocking feature. True-cut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by polyethylene cover. 2 P GAX 428T8 432 24, 32, 36 Cell 6-3/4" [172mm] 2' X 4' PARABOLIC 4 T8 LAMPS SEMI-SPECULAR LOUVER Paralux IV Recessed Air Supply Troffer 23-3/4" [603mm] MOUNTING D A TA L A MP CONF IGURA T IONS Access Plate 7/8" [22mm] 2/4 LAMP 7/8" [22mm] K.O. (2) 4 LAMP – 24/32/36 CELL 6-3/4" [172mm] 4" [102mm] X=4-3/4" [121mm] 23-3/4" [603mm] ENERGY DATA X 5-3/4" X [146mm] Input Watts: EB Ballast & STD Lamps 428T8 (93), 432 (113) 23-3/4" [603mm] Luminaire Efficacy Rating LER = FP-50 Catalog Number: 2PGAX-432 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.81 4-5/8" [119mm] 3" [77mm] 48" [1217mm] 7-7/8" [201mm] C EILING C OM PA TA BI L I T Y G Grid/Lay-in Standard G Concealed T G Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS (Verify compatibility/ consult factory.) Safe and convenient means of disconnecting power. ADF090549 2015-10-22 10:32:37 PH OTOM ETR IC S Candlepower 2PGAX-432S46I Electronic Ballast F32T8/35K Lamps 2850 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency 62.9% Test Report: 2PGX432S46I.IES LER = FP-54 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.45 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 3226 3212 3133 3036 2915 2771 2610 2426 2223 1983 1697 1338 843 283 84 37 17 4 0 Across ⊥ 3226 3231 3287 3366 3519 3518 3124 2491 2098 1771 1469 1134 437 155 68 30 11 2 0 45° 3226 3220 3208 3194 3173 3169 3117 2834 2312 1794 1429 1069 574 172 63 29 11 2 0 75 68 61 55 50 45 41 37 34 32 29 75 66 58 51 45 40 36 32 29 27 25 75 64 55 48 41 36 32 29 26 24 22 73 69 64 59 55 51 47 44 41 38 36 73 67 60 54 49 44 40 37 34 31 29 73 65 57 50 45 40 36 32 29 27 24 73 63 54 47 41 36 32 29 26 24 21 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 2668 4306 6776 7045 7045 %Lamp 23.8 38.5 60.5 62.9 62.9 FO32T8/35K Lamps 2850 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency 58.1% Test Report: 2PGX432S49I.IES LER = FP-50 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.81 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 3254 3234 3135 3015 2874 2717 2534 2328 2078 1764 1325 830 279 109 55 27 13 2 0 Across ⊥ 3254 3257 3302 3364 3502 3545 3219 2573 2119 1750 1438 1094 399 148 67 30 14 2 0 45° 3254 3245 3218 3172 3119 3084 3026 2748 2225 1671 1241 768 266 99 48 24 12 2 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 75 70 65 60 56 52 48 45 42 39 37 Candlepower 2PGAX-432S49I Electronic Ballast Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 2 P GAX-4 3 2 P H OT OME T RICS %Fixture 37.9 61.1 96.2 100.0 100.0 20% 50% 50 30 10 30% 50 30 10 50 70 64 58 52 47 43 39 36 33 28 28 67 62 56 51 46 42 38 35 32 28 28 64 59 54 49 45 41 37 34 32 27 27 70 63 55 49 44 39 35 32 29 24 24 70 61 53 46 41 36 32 29 26 21 21 67 60 54 48 43 38 35 31 28 24 24 67 59 52 46 40 36 32 28 26 21 21 10% 30 10 64 58 52 47 42 38 34 31 28 24 24 64 58 51 45 40 35 31 28 26 21 21 0% 0 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 63 56 50 44 38 34 30 27 24 20 20 Ty p i c a l VC P Pe r c e n t a g e s Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Along 8.5’ 10.0’ 83 77 88 83 90 86 89 85 90 87 Height Across 8.5’ 10.0’ 88 81 91 86 91 88 91 87 92 89 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 69 65 61 56 52 49 45 42 40 37 35 69 63 57 52 47 42 39 35 33 30 28 69 61 54 48 43 38 34 31 28 26 24 69 60 51 45 39 35 31 28 25 23 21 68 64 59 55 51 48 44 41 39 36 34 68 62 56 51 46 42 38 35 32 30 28 68 60 53 47 42 38 34 31 28 26 24 68 59 51 44 39 35 31 28 25 23 21 20% 50% 50 30 10 30% 50 30 10 50 65 59 54 49 45 41 37 34 32 29 27 62 57 52 48 43 40 36 33 31 29 27 59 55 51 46 42 39 35 33 30 28 26 65 58 52 46 41 37 34 30 28 25 23 65 57 50 44 39 34 31 28 25 23 21 62 56 50 45 40 36 33 30 27 25 23 62 55 49 43 38 34 31 28 25 23 21 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens 2641 4247 6344 6505 6505 %Lamp 23.6 37.9 56.6 58.1 58.1 %Fixture 40.6 65.3 97.5 100.0 100.0 Height Along 8.5’ 10.0’ 91 87 93 90 94 91 93 91 94 91 10% 30 10 59 54 49 44 40 36 33 30 27 25 23 59 53 48 42 38 34 30 27 25 23 21 0% 0 58 52 47 41 37 33 29 26 24 22 20 Height Across 8.5’ 10.0’ 90 85 93 89 93 90 93 89 93 90 ORDER IN G INFOR M A TION SAMPLE NUMBER: 2PGAX-432S49I-120V-EB81-U Rating Blank= Standard ATW-SW4= Chicago Rated HR=Heat Removal (1) Width 2=2' width P=Paralux IV Trim Type G=Grid/Lay-in (Standard) G=Concealed T/Slot Grid (6) F=Aluminum Flange Trim (7) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4) Number of Lamps 4=4 Lamps Wattage (Length) 28T8=28W T8 (48") 32=32W T8 (48") Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (5) Louver Color S=Silver W=White Cell Configuration 46=4 Rows of 6, 24 Cell 48=4 Rows of 8, 32 Cell 49=4 Rows of 9, 36 Cell Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard MI=Specular/Mirrored (Low Iridescent) P=Painted Option – Aluminum Flange Trim (7) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row (1) Lamps Installed Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K L8841=T8 Lamp, 28W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens (2) NOTES: Integral End Plate Grid Lock feature not available in Heat Removal. An EQ Grid Clip is recommended for (3) all 9/16" ceiling systems. Four required per fixture. Products also available in non-US voltages and frequencies for (4) (5) international markets. Not available when specifying emergencies, voltage must be specific. Fixtures equipped (6) with “EL” option may require a 7-1/2" housing depth. If installing in field, must use low profile battery pack. Louver (7) is recessed by 5/16" in Concealed T or Slot Grid T. Specify row configuration, type in catalog number when ordering complete fixture. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% No. of High Ballast Factor >1.15 Ballast 1, 2 or 3 Options PAF=Painted After Fabrication REP=Riveted Endplates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 ACCESSORIES SH IP P ING D A T A EQ-CLIP-U=T-BAR Safety Earthquake Clips(2) Catalog No. 2PGAX-432S46I 2PGAX-432S48I 2PGAX-432S49I Wt. 42 lbs. 42 lbs. 42 lbs. ADF090549 2015-10-22 10:32:37