Metalux D ES C R IPTION The Paralux IV Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a 4" precision cell louver into a deep para-contoured fixture housing. This combination creates a high comfort parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The high comfort luminaire is designed to provide a superior visual environment plus the higher shielding louver angle offers excellent cut-off for today‘s lighting requirements. The Paralux IV series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by S PEC IFIC A TION FEA T U R E S Construction E le ctrica l* * H inging/Latching 7-5/8" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Ballast/ wireway cover easily removed. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates, securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have integral Grid-Lock feature for safety and convenience. Housing features enable fixture to be converted from Grid to T-option or vice versa in the field.* Ballast are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. Positive cam action spring loaded, self locking, black steel latches. Louver retained by four safety chains. Provided for field installation. F in ish Louver Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Die formed of semi-specular, vertical grain, aluminum. Finish is anodic oxide coating. Accurate precision parabolic cells are held in place with interlocking feature. True-cut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by polyethylene cover. PGAX 128T8 132 228T8 232 16 Cell 1' X 4' PARABOLIC 1 OR 2 T8 LAMPS SEMI-SPECULAR LOUVER 7-5/8" [194mm] Paralux IV Recessed Air Supply Troffer 11-3/4" [298mm] ENERGY DATA MOUNTING D A TA L A MP CONF IGURA T IONS 7/8" [22mm] K.O. (2) Access Plate 7/8" [22mm] K.O. (2) 1-1/2" [38mm] 1 LAMP 2 LAMP 7-5/8" [194mm] 7-5/8" [194mm] 4" [102mm] 11-3/4" [298mm] 11-3/4" [298mm] 4" [102mm] X=3-1/4" [83mm] Input Watts: EB Ballast & STD Lamps 128T8 (27), 132 (30), 228T8 (48), 232 (55) X 11-3/4" [298mm] 5-1/4" [133mm] 3-1/2" [89mm] Luminaire Efficacy Rating LER = FP-43 Catalog Number: PGAX-132 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $5.53 6-1/4" [159mm] 48" [1219mm] *Convertibility applies to housing only. Appropriate shielding media assemblies must be utilized. C EILING C OM PA TA BI L I T Y G Grid/Lay-in Standard T Concealed T T Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G or T G or T F MZ MZ **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS (Verify compatibility/ consult Pre Sales Technical Support.) Safe and convenient means of disconnecting power. ADF020514 2015-10-13 16:32:52 P GAX PH OTOM ETR IC S Coefficients of Utilization PGAX-132S28I Energy Saving Ballast FO32T8/35K lamps 2850 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 2.0 x mounting height Efficiency = 52.6% Test Report: PGX132S28I.IES rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 63 59 54 50 46 43 39 36 34 32 29 63 57 51 46 41 37 33 30 27 25 23 63 55 48 42 37 32 29 26 23 21 19 63 53 46 39 34 29 26 23 20 18 16 61 57 53 49 45 42 38 36 33 31 29 61 56 50 45 40 36 33 29 27 24 22 61 54 47 41 36 32 29 25 23 21 19 61 53 45 39 33 29 26 21 20 18 16 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 58 53 48 43 39 35 32 29 26 24 22 56 51 46 42 38 34 31 28 26 23 21 54 50 45 41 37 33 30 27 25 23 21 53 47 41 36 31 27 24 21 19 17 15 58 52 46 40 36 32 28 25 22 20 18 58 51 44 38 33 29 25 22 20 18 16 56 50 45 39 35 31 28 25 22 20 18 56 49 43 37 33 29 25 22 20 18 16 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 0-90 0-180 Lumens %Lamp %Fixture 421 813 1437 1473 1473 15.0 29.0 51.3 52.6 52.6 28.6 55.2 97.6 100.0 100.0 60 x 30 60 x 60 Height Along 8.5’ 10.0’ 92 91 93 93 94 93 94 93 93 93 54 49 43 39 34 30 27 24 22 20 18 54 48 42 37 32 28 25 22 20 18 16 Height Across 8.5’ 10.0’ 93 91 94 93 94 93 94 93 94 93 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 45° Across⊥ 461 460 451 437 421 405 387 364 335 294 240 167 83 28 13 7 2 0 0 461 463 465 476 493 517 541 582 671 680 497 217 59 23 11 5 1 0 0 461 469 487 526 579 632 768 961 978 702 353 130 53 27 15 6 2 0 0 Luminance Data LER = FP-43 Angle in Deg 45 55 65 75 85 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH=$5.53 Average 0-Deg cd/sm 1609 1126 256 105 0 Average 45-Deg cd/sm 3721 1464 211 75 0 Average 90-Deg cd/sm 3841 877 247 90 0 ORDER ING INFOR M A TION SAMPLE NUMBER: PGAX-132S28I-120V-EB81-U Rating Blank= Standard ATW-SW4= Chicago Rated Heat Removal (1) HR=Heat Removal HRDO=Heat Removal Damper Open HRDC=Heat Removal Damper Closed Width Blank=1' width or 20" width P=Paralux IV Trim Type (2) G=Grid/Lay-in – Standard T=Concealed T /Slot (3) F=Aluminum Flange Trim (6) MZ=Modular Trim Air Supply AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply AVX=Air Supply Floating Louver with Directional Air Vane Voltage (4) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (5) Number of Lamps 1 or 2 lamps Wattage 28T8=28W T8 (48") 32=32W T8 (48") Louver Color S=Silver W=White Cell Configuration 28=2 Rows of 8, 16 Cell (1' x 4') Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard MI=Specular/Mirrored (Low Iridescent) P=Painted Option – Aluminum Flange Trim (6) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed Lamps Installed Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K L8841=T8 Lamp, 28W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens (1) NOTES: Integral End Plate Grid Lock feature not available in Heat Removal. (2) Convertibility applies to housing only, appropriate shielding media assemblies must (3) be utilized. Fixture also adaptable with flanged or modular trims. An EQ Grid Clip is (4) recommended for all 9/16" ceiling systems. Four required per fixture. Products also (5) available in non-US voltages and frequencies for international markets. Not available (6) when specifying emergencies, voltage must be specific. Specify row configuration, type in catalog number when ordering complete fixture. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% No. of High Ballast Factor >1.15 Ballast 1, 2 or 3 Options PAF=Painted After Fabrication REP=Riveted Endplates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips (3) SH IP P ING D A T A Catalog No. PGAX-132S28I PGAX-232S28I Wt. 19 lbs. 19 lbs. ADF020514 2015-10-13 16:32:52