COOPER LIGHTING - METALUX D es c r iption The OpticaHP series is an energy saving solution for a multitude of applications. The OpticaHP series incorporates a 2" high, 6-cell louver combined with a precision engineered cross blade to create a soft, even distribution while delivering a highly efficient T8 luminaire. The OpticaHP series is an excellent choice for new commercial office spaces, schools, hospitals or retail merchandising areas. ® Type Catalog # Project Date Comments Prepared by Spec ific a tion F ea t u r e s Construction Ele ctrica l* * H inging/Latching 4-3/4" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Full length die formed stiffeners for added strength. Contoured ballast/ wireway cover, easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates, securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have integral Grid-Lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. Positive cam action spring loaded, self locking, steel latches with safety lock T-hinges allow hinging and latching from either side. Controls Fin ish Cold rolled steel w/multistage iron phosphate pretreatment for maximum bonding and a highly reflective matte white finish on reflective surfaces for increased efficiency. Op tics Fifth Light ballast options are offered for both 0-10V continuous dimming and DALI applications. Combine with energy-saving products like occupancy sensors, daylighting controls, and lighting relay panels from Cooper Controls (www.coopercontrol.com) to maximize energy savings. Die formed white louver w/faceted straight-blade cross-members are engineered for optimal efficiency and performance. True-cut mitered corners and interlocking features provide strength and durability. Louver is protected by polyethyline cover when shipped w/fixture. OpticaHP Series 128T8 132 228T8 232 6 Cell 1' x 4' 1 or 2 Lamps 6-5/8" [168mm] 11-3/4" [298mm] Energy Data Mounting D a ta L a mp Conf igura t ions 7/8" [22mm] K.O. (2) Access Plate 7/8" [22mm] K.O. (2) 1-1/2" [38mm] 11-3/4" [298mm] 1 LAMP 2 LAMP 6-5/8" [168mm] 6-5/8" [168mm] 2" [51mm] 11-3/4" [298mm] 2" [51mm] X=1-3/4" [44mm] Input Watts: HB Ballast & HL Lamps 128T8 (27), 132 (30) 228T8 (48), 232 (55) X 11-3/4" [298mm] Luminaire Efficacy Rating LER = FP-79 Catalog Number: OPG-232FB16W Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.04 5-1/4" [133mm] 3-1/2" [89mm] 6-1/4" [159mm] 48" [1219mm] *Convertibility applies to housing only. Appropriate shielding media assemblies must be utilized. Ceil ing C om pa tib il i t y G Grid/Lay-in Standard F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or “Z” Metal Pan G G G F MZ MZ (Verify compatibility/ consult Pre Sales Technical Support.) Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF092092 2013-04-10 13:33:37 O p t ic aH P 1 ' x 4 ' Ph otom etr ic s OPG-232FB16W Candlepower Electronic Ballast F32T8/50K Lamps ⊥ || 3100 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height Efficiency 83.5% Test Report: OPG-232FB16W.IES LER = FP79 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.04 Along II 632 628 616 598 572 542 506 465 421 375 326 276 226 174 122 76 45 20 0 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 45° 632 631 623 609 588 563 533 502 465 422 376 323 254 184 112 62 36 15 0 Across ⊥ 632 631 628 619 607 592 576 548 518 477 408 334 247 139 82 50 26 10 0 C o e f fi c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 99 92 84 77 70 65 60 56 52 48 45 99 88 77 68 61 54 49 45 41 37 34 99 85 72 62 54 47 42 37 34 31 28 99 82 68 57 48 42 37 32 29 26 24 97 89 82 75 69 63 58 54 50 47 44 97 86 76 67 60 54 48 44 40 37 34 97 83 71 61 53 47 41 37 33 30 28 97 80 67 56 48 42 36 32 29 26 24 20% 50% 50 30 10 30% 50 30 10 50 93 83 73 65 58 52 47 43 39 36 33 89 79 70 62 56 50 45 41 38 35 32 85 76 68 60 54 49 44 40 37 34 32 93 80 69 59 52 46 41 36 33 30 27 93 78 65 55 47 41 36 32 29 26 23 89 77 67 58 51 45 40 36 32 30 27 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 493 809 1412 1669 1669 %Lamp 24.6 40.4 70.6 83.5 83.5 %Fixture 29.5 48.4 84.6 100.0 100.0 Average 0-Deg cd/sm 1427 1294 1108 790 617 89 76 64 54 47 41 36 32 28 26 23 10% 30 10 Average 45-Deg cd/sm 1605 1515 1171 644 463 85 75 65 57 50 44 39 35 32 29 27 85 73 62 53 46 40 36 32 28 26 23 0% 0 84 72 61 52 44 39 34 30 27 24 22 Average 90-Deg cd/sm 1815 1566 885 520 309 Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 ADF092092 2013-04-10 13:33:37 O p t ic aH P 1 ' x 4 ' Order ing I nfor m a tion SAMPLE NUMBER: OPG-232FB16W-UNV-HB81-U Width Blank=1' Width Series OP=Optica Trim Type G=Grid/Lay-in – Standard(6) F=Aluminum Flange Trim (5) MZ=Modular Trim Number of Lamps 1=1 Lamp 2=2 Lamps Wattage 28T8=28W T8 (48") (7) 32=32W T8 (48") Cross-Blade FB=Faceted Blade Cell Configuration 16=1 Row of 6, 6 Cell (1'x4') Louver Finish W=Matte White Option – Aluminum Flange Trim (5) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Voltage (2) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (3) Options GL=Single Element Fuse GM=Double Element Fuse Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (4) Lamps Installed Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K (7) L8841=T8 Lamp, 28W and 32W, 4100K (7) L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10%. High Ballast Factor > 1.15. ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(1) 0-10V Dimming Ballasts (9) 5LTV8 =T8 0-10V Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 0.87 5LTVS8 =T8 0-10V Spec Grade Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 0.87 (10) Fifth Light DALI Ballasts (8) 5LT8 =T8 DALI Program Rapid Start. Total Harmonic Distortion < 10%. Ballast Factor 1.0 Number of Ballasts 1=1 Ballast 2=2 Ballasts 3=3 Ballasts (1) (2) (3) NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Products also available in non-US voltages and frequencies for international markets. Not available when specifying (4) (5) emergencies, voltage must be specific. Fixtures equipped with “EL” option may require a 5-1/2" housing depth. If installing in field, must use low profile battery pack. Specify row configuration, type in catalog number (6) (7) (8) when ordering complete fixture. Louver is recessed by 5/16" in Concealed T or Slot Grid. When utilizing 28W T8 lamps, HBT8 ballast must be specified. For a complete listing of Fifthlight Technology products and other (9) (10) solutions from Cooper Controls, visit www.coopercontrol.com. 0-10V ballast do not include DALI feature. Please select DALI ballast for use with Fifth Light system. Specification grade 0-10V dimming ballast are NEMA premium and CEE listed. They are compatible with low mercury and energy saving lamps. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. SH IPPING D ATA Catalog No. OPG-132FB16W OPG-232FB16W Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 Wt. 29 lbs. 29 lbs. ADF092092 2013-04-10 13:33:37