COOPER LIGHTING - METALUX

advertisement
COOPER LIGHTING - METALUX
D es c r iption
The OpticaHP series is an energy saving solution for a multitude of
applications. The OpticaHP series incorporates a 2" high, 6-cell louver
combined with a precision engineered cross blade to create a soft, even
distribution while delivering a highly efficient T8 luminaire. The OpticaHP
series is an excellent choice for new commercial office spaces, schools,
hospitals or retail merchandising areas.
®
Type
Catalog #
Project
Date
Comments
Prepared by
Spec ific a tion F ea t u r e s
Construction
Ele ctrica l* *
H inging/Latching
4-3/4" deep, para-contoured
housing, die formed code gauge,
prime cold rolled steel. Full length
die formed stiffeners for added
strength. Contoured ballast/
wireway cover, easily removed
without tools. Die formed captive
lampholder bracket fully encloses
lampholder wiring permitting easy
lampholder replacement. Heavy
end plates, securely attached with
interlocking tabs and screws. Four
auxiliary fixture end suspension
points provided. KOs for
continuous row wiring. End plates
have integral Grid-Lock feature for
safety and convenience.
Ballasts are CBM/ETL Class “P” are
positively secured by mounting
bolts. Pressure lock lampholders.
UL/CUL listed. Suitable for damp
locations.
Positive cam action spring loaded,
self locking, steel latches with
safety lock T-hinges allow hinging
and latching from either side.
Controls
Fin ish
Cold rolled steel w/multistage
iron phosphate pretreatment for
maximum bonding and a highly
reflective matte white finish on
reflective surfaces for increased
efficiency.
Op tics
Fifth Light ballast options are
offered for both 0-10V continuous
dimming and DALI applications.
Combine with energy-saving
products like occupancy sensors,
daylighting controls, and lighting
relay panels from Cooper Controls
(www.coopercontrol.com) to
maximize energy savings.
Die formed white louver w/faceted
straight-blade cross-members are
engineered for optimal efficiency
and performance. True-cut mitered
corners and interlocking features
provide strength and durability.
Louver is protected by polyethyline
cover when shipped w/fixture.
OpticaHP
Series
128T8
132
228T8
232
6 Cell
1' x 4'
1 or 2 Lamps
6-5/8"
[168mm]
11-3/4"
[298mm]
Energy Data
Mounting D a ta
L a mp Conf igura t ions
7/8" [22mm] K.O. (2)
Access Plate
7/8" [22mm] K.O. (2)
1-1/2"
[38mm]
11-3/4"
[298mm]
1 LAMP
2 LAMP
6-5/8"
[168mm]
6-5/8"
[168mm]
2" [51mm]
11-3/4"
[298mm]
2" [51mm]
X=1-3/4"
[44mm]
Input Watts:
HB Ballast & HL Lamps
128T8 (27), 132 (30)
228T8 (48), 232 (55)
X
11-3/4"
[298mm]
Luminaire Efficacy Rating
LER = FP-79
Catalog Number: OPG-232FB16W
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.04
5-1/4" [133mm]
3-1/2" [89mm]
6-1/4" [159mm]
48" [1219mm]
*Convertibility applies to housing only.
Appropriate shielding media assemblies
must be utilized.
Ceil ing C om pa tib il i t y
G
Grid/Lay-in
Standard
F
Aluminum Flange Trim
With Supporting
Swing Gates
MZ
Modular Trim
With Supporting
Swing Gates
Ceiling
Type
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
Concealed “T” or “Z”
Metal Pan
G
G
G
F
MZ
MZ
(Verify compatibility/ consult
Pre Sales Technical Support.)
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
**Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF092092
2013-04-10 13:33:37
O p t ic aH P 1 ' x 4 '
Ph otom etr ic s
OPG-232FB16W
Candlepower
Electronic Ballast
F32T8/50K Lamps
⊥
||
3100 Lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.3 x
mounting height
Efficiency 83.5%
Test Report:
OPG-232FB16W.IES
LER = FP79
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.04
Along II
632
628
616
598
572
542
506
465
421
375
326
276
226
174
122
76
45
20
0
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
45°
632
631
623
609
588
563
533
502
465
422
376
323
254
184
112
62
36
15
0
Across ⊥
632
631
628
619
607
592
576
548
518
477
408
334
247
139
82
50
26
10
0
C o e f fi c i e n t s o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
99
92
84
77
70
65
60
56
52
48
45
99
88
77
68
61
54
49
45
41
37
34
99
85
72
62
54
47
42
37
34
31
28
99
82
68
57
48
42
37
32
29
26
24
97
89
82
75
69
63
58
54
50
47
44
97
86
76
67
60
54
48
44
40
37
34
97
83
71
61
53
47
41
37
33
30
28
97
80
67
56
48
42
36
32
29
26
24
20%
50%
50 30 10
30%
50 30 10
50
93
83
73
65
58
52
47
43
39
36
33
89
79
70
62
56
50
45
41
38
35
32
85
76
68
60
54
49
44
40
37
34
32
93
80
69
59
52
46
41
36
33
30
27
93
78
65
55
47
41
36
32
29
26
23
89
77
67
58
51
45
40
36
32
30
27
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
493
809
1412
1669
1669
%Lamp
24.6
40.4
70.6
83.5
83.5
%Fixture
29.5
48.4
84.6
100.0
100.0
Average
0-Deg
cd/sm
1427
1294
1108
790
617
89
76
64
54
47
41
36
32
28
26
23
10%
30 10
Average
45-Deg
cd/sm
1605
1515
1171
644
463
85
75
65
57
50
44
39
35
32
29
27
85
73
62
53
46
40
36
32
28
26
23
0%
0
84
72
61
52
44
39
34
30
27
24
22
Average
90-Deg
cd/sm
1815
1566
885
520
309
Specifications and dimensions subject to change without notice.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801
ADF092092
2013-04-10 13:33:37
O p t ic aH P 1 ' x 4 '
Order ing I nfor m a tion
SAMPLE NUMBER: OPG-232FB16W-UNV-HB81-U
Width
Blank=1' Width
Series
OP=Optica
Trim Type
G=Grid/Lay-in – Standard(6)
F=Aluminum Flange Trim (5)
MZ=Modular Trim
Number
of Lamps
1=1 Lamp
2=2 Lamps
Wattage
28T8=28W T8 (48") (7)
32=32W T8 (48")
Cross-Blade
FB=Faceted Blade
Cell Configuration
16=1 Row of 6, 6 Cell (1'x4')
Louver Finish
W=Matte White
Option – Aluminum Flange Trim (5)
Blank=SW (Single White)
Type
Color
‘S’ Single
‘N’ Natural
‘R’ In Row
‘W’ White
‘E’ End of Row
Voltage (2)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277 (3)
Options
GL=Single Element
Fuse
GM=Double
Element Fuse
Flex=Flex Installed
(Reference Flex
ordering information)
EL=Emergency
Installed (4)
Lamps Installed
Blank=No Lamps
Installed
L8835=T8 Lamp, 28W
and 32W, 3500K (7)
L8841=T8 Lamp, 28W
and 32W, 4100K (7)
L8835HL=T8 Lamp,
32W, 3500K, 3100
Lumens
L8841HL=T8 Lamp,
32W, 4100K, 3100
Lumens
Packaging
U=Unit Pack
PAL=Job Pack, out
of carton
PALC=Job Pack, in
carton
Ballast Type
EB8 =T8 Electronic Start.
Total Harmonic Distortion < 10%
EB8 /PLUS= T8 Electronic Start.
Total Harmonic Distortion < 10%.
High Ballast Factor > 1.15.
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
High Performance T8 Ballasts
HB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
Standard Ballast Factor .86 – .88
HB8 L=T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
Low Ballast Factor .77 – .82
HB8 N=T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
High Ballast Factor 1.15 – 1.20
HR8 T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Standard Ballast Factor .86 – .88
HR8 DIM=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Low Ballast Factor .71 – .79
HR8 H=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
High Ballast Factor 1.15 – 1.20
ACCESSORIES
EQ-CLIP-U=T-BAR Safety
Earthquake Clips(1)
0-10V Dimming Ballasts (9)
5LTV8 =T8 0-10V Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 0.87
5LTVS8 =T8 0-10V Spec Grade Program Rapid
Start. Total Harmonic Distortion <
10%. Ballast Factor 0.87 (10)
Fifth Light DALI Ballasts (8)
5LT8 =T8 DALI Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 1.0
Number of Ballasts
1=1 Ballast
2=2 Ballasts
3=3 Ballasts
(1)
(2)
(3)
NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Products also available in non-US voltages and frequencies for international markets. Not available when specifying
(4)
(5)
emergencies, voltage must be specific. Fixtures equipped with “EL” option may require a 5-1/2" housing depth. If installing in field, must use low profile battery pack. Specify row configuration, type in catalog number
(6)
(7)
(8)
when ordering complete fixture. Louver is recessed by 5/16" in Concealed T or Slot Grid. When utilizing 28W T8 lamps, HBT8 ballast must be specified. For a complete listing of Fifthlight Technology products and other
(9)
(10)
solutions from Cooper Controls, visit www.coopercontrol.com. 0-10V ballast do not include DALI feature. Please select DALI ballast for use with Fifth Light system.
Specification grade 0-10V dimming ballast are NEMA premium and
CEE listed. They are compatible with low mercury and energy saving lamps.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
SH IPPING D ATA
Catalog No.
OPG-132FB16W
OPG-232FB16W
Specifications and dimensions subject to change without notice.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801
Wt.
29 lbs.
29 lbs.
ADF092092
2013-04-10 13:33:37
Download