Metalux

advertisement
Metalux
D ES C R IPTION
The Paralux II Series features recessed aesthetics and the latest in energy
efficient technology. The luminaire incorporates a 2" precision cell louver
into a 4-3/4" deep para-contoured fixture housing. This combination
creates a total low profile parabolic optical assembly for optimum
performance. The series is compatible with all of today’s popular ceiling
systems and is available with a number of options and accessories for
application versatility. The low profile luminaire is designed to offer
the market-place a parabolic choice when economics and shallow
plenum space are factors. The Paralux II series is an excellent choice
for commercial office spaces, schools, hospitals or retail merchandising
areas.
Type
Catalog #
Project
Date
Comments
Prepared by
SPE C IFIC A TION FEA T U R E S
C on s t r u c t i o n
E le ctrica l* *
H inging/Latching
4-3/4" deep, para-contoured
housing, die formed code gauge,
prime cold rolled steel. Full length
die formed stiffeners for added
strength. Contoured ballast/
wireway cover, easily removed
without tools. Die formed captive
lampholder bracket fully encloses
lampholder wiring permitting easy
lampholder replacement. Heavy
end plates, securely attached with
interlocking tabs and screws. Four
auxiliary fixture end suspension
points provided. KOs for
continuous row wiring. End plates
have integral Grid-Lock feature for
safety and convenience."
Ballasts are CBM/ETL Class “P” and
are positively secured by mounting
bolts. Pressure lock lampholders.
UL/CUL listed. Suitable for damp
locations.
Positive cam action spring loaded,
self locking, black steel latches.
Safety lock T-hinges allow hinging
and latching either side.
Louver
Die formed of semi-specular
aluminum. Finish is anodic oxide
coating. Accurate precision
parabolic cells are held in place
by interlocking feature. True-cut
mitered corners. Black reveal
with mechanical light seal around
entire perimeter of louver. Louver
protected by polyethylene cover.
F in ish
Lighting grade, baked white
enamel finish. Multistage, iron
phosphate pretreatment ensures
maximum bonding and rust
inhibition.
2P2GAX
328T8
332
18, 24 Cell
4-3/4"
[121mm]
2' X 4' PARABOLIC
3 T8 LAMPS
SEMI-SPECULAR LOUVER
Paralux II
Recessed Air Supply Troffer
23-3/4"
[603mm]
MOUNTING D A TA
3 LAMP
L A MP CONF IGURA T IONS
Access Plate
7/8" [22mm] K.O.
7/8" [22mm] K.O. (4)
3 LAMP – 18/24 CELL
4-3/4"
[121mm]
2"
[51mm]
7"
7"
[178mm] [178mm]
23-3/4" [603mm]
ENERGY DATA
23-3/4"
[603mm]
Input Watts:
EB Ballast & STD Lamps
328T8 (67)
332 (81)
ISOL A T E D L A MP CA V IT Y
4-5/8" [119mm]
3" [77mm]
48" [1217mm]
7-7/8" [201mm]
Isolated lamp cavity option available. Requires two
contoured ballast covers. Provides High VCP.
Example: 2P2GAX-332S36H-120V-2BC.
Luminaire Efficacy Rating
LER = FP-65
Catalog Number: 2P2GAX-332S36I
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.69
C EILING C OM PA TIB IL I T Y
G
Grid/Lay-in
Standard
G
Concealed T
G
Slot Grid
F
Aluminum Flange Trim
With Supporting
Swing Gates
MZ
Modular Trim
With Supporting
Swing Gates
Ceiling
Type
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
Concealed “T” or ”Z“
Metal Pan
G
G
G
F
MZ
MZ
(Verify compatibility/ consult
factory.)
**Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF090386
2015-10-13 15:59:17
2 P 2 GAX 3 L T 8
PH OTOM ETR IC S
Candlepower
2P2GAX-332S36I
Electronic Ballast
F32T8/35K lamps
2900 lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.6 x
mounting height
Efficiency = 74.7%
Test Report:
2P2GX332S36I.IES
LER = FP-65
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.69
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
2288
2277
2244
2191
2118
2028
1921
1797
1655
1494
1309
1096
856
581
290
77
27
8
0
Across ⊥
2288
2297
2325
2359
2381
2434
2599
2707
2546
2025
1350
808
532
320
150
26
12
5
0
45°
2288
2284
2282
2273
2256
2223
2179
2171
2177
2081
1786
1294
764
378
189
60
15
5
0
F32T8/35K lamps
2900 lumens
||
89
80
72
65
58
52
47
42
37
33
30
89
78
68
60
53
46
41
36
31
27
24
89
76
65
56
48
42
36
31
27
23
20
87
81
76
70
64
59
54
50
46
42
39
87
79
71
64
57
51
46
41
37
33
30
87
77
67
59
52
46
40
35
31
27
24
87
75
64
56
48
41
36
31
27
23
20
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
0-180
Lumens
1892
3281
5730
6279
6279
%Lamp
22.5
39.1
68.2
74.7
74.7
Efficiency = 72.7%
Test Report:
2P2GX332S38I.IES
LER = FP-63
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.81
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
2309
2300
2263
2203
2125
2031
1922
1794
1644
1473
1276
1039
765
443
152
57
22
7
0
Across ⊥
2309
2316
2343
2375
2396
2464
2628
2708
2517
1995
1340
800
531
320
152
25
11
4
0
45°
2309
2306
2301
2287
2265
2226
2182
2178
2159
2023
1695
1198
686
329
159
41
14
5
0
Coefficients of Utilization
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
89
83
77
72
66
61
56
51
47
43
40
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.6 x
mounting height
⊥
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Candlepower
2P2GAX-332S38I
Electronic Ballast
%Fixture
30.1
52.3
91.3
100.0
100.0
20%
50%
50 30 10
30%
50 30 10
50
83
76
69
62
56
50
45
40
36
32
29
80
73
66
60
54
48
44
39
35
31
28
76
70
64
58
52
47
42
38
34
30
28
83
74
65
58
51
45
40
35
31
27
24
83
72
63
55
48
41
36
31
27
23
20
80
71
64
57
50
44
39
34
30
26
23
80
70
61
54
47
41
35
31
27
23
20
10%
30 10
76
69
62
55
49
43
38
34
30
26
23
76
68
60
53
46
40
35
31
27
23
20
0%
0
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
75
67
59
51
45
39
34
29
25
21
19
Ty p i c a l VC P Pe r c e n t a g e s
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Height Along
8.5’
10.0’
69
66
77
72
81
76
79
76
83
80
Height Across
8.5’
10.0’
77
75
83
78
86
83
85
83
87
86
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
81
76
71
66
61
57
52
48
45
41
38
81
74
67
61
55
49
44
40
36
32
29
81
72
63
56
50
44
39
35
31
27
24
81
70
61
53
46
40
35
31
27
23
21
79
75
70
65
60
55
51
47
44
40
37
79
72
66
60
54
48
44
40
36
32
29
79
70
63
56
49
44
39
34
30
27
24
20%
50%
50 30 10
30%
50 30 10
50
76
70
63
58
52
47
43
39
35
31
28
73
67
61
56
51
46
42
38
34
30
28
70
65
59
54
49
45
41
37
33
30
27
79
69
60
52
46
40
35
31
27
23
21
76
68
61
54
48
43
38
34
30
26
24
76
67
59
51
45
39
35
31
27
23
21
73
66
59
53
47
42
38
34
30
26
23
73
65
57
51
45
39
35
30
27
23
20
Zonal Lumen Summary
Ty p i c a l VC P Pe r c e n t a g e s
Zone
0-30
0-40
0-60
0-90
0-180
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Lumens
1903
3291
5657
6110
6110
%Lamp
22.7
39.2
67.3
72.7
72.7
%Fixture
31.1
53.9
92.6
100.0
100.0
10%
30 10
70
64
58
52
46
41
37
33
29
26
23
Height Along
8.5’
10.0’
75
71
82
77
85
81
83
81
86
84
70
63
56
50
44
39
34
30
26
23
20
0%
0
68
61
55
49
43
37
33
29
25
22
19
Height Across
8.5’
10.0’
78
76
85
80
87
84
87
84
89
87
ORDER ING INFOR M A TION
SAMPLE NUMBER: 2P2GAX-332S36I-UNV-EB81-U
Rating
Blank=
Standard
ATW-SW4=
Chicago
Rated
HR=Heat
Removal (1)
Width
2=2' Width
P=Paralux Louver
2=2" Louver Depth
Trim Type
G=Grid/Lay-in (Standard)
G=Concealed T/Slot Grid (9)
F=Aluminum Flange Trim (7)
MZ=Modular Trim
AX=Air Supply Floating Louver
X=Blank Side/Floating Louver Non-Air Supply (Omit A)
AVX=Air Supply Floating Louver
with Directional Air Vane (Add V)
Voltage (4)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277 (5)
Number
of Lamps (3)
3 lamps
Wattage (Length)
28T8=28W T8 (48")
32=32W T8 (48")
Louver Color
S=Silver
W=White
Cell Configuration
36=3 Rows of 6, 18 Cell
38=3 Rows of 8, 24 Cell
Louver Finish
I=Semi-Specular/Haze
(Low Iridescent) Standard
MI=Specular/Mirrored
(Low Iridescent)
P=Painted
Option – Aluminum Flange Trim (7)
Blank=SW (Single White)
Type
Color
‘S’ Single
‘N’ Natural
‘R’ In Row
‘W’ White
‘E’ End of Row
(1)
Options
GL=Single Element
Fuse
GM=Double
Element Fuse
WTR=White Reveal
Flex=Flex Installed
(Reference Flex
ordering information)
EL=Emergency
Installed (8)
Lamps Installed
Blank=No Lamps
Installed
L8835=T8 Lamp, 28W
and 32W, 3500K
L8841=T8 Lamp, 28W
and 32W, 4100K
L8835HL=T8 Lamp,
32W, 3500K, 3100
Lumens
L8841HL=T8 Lamp,
32W, 4100K, 3100
Lumens
Ballast Type
EB8 =T8 Electronic Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EB8 /PLUS= T8 Electronic Start.
Total Harmonic Distortion < 10%
No. of
High Ballast Factor >1.15
Ballast
1, 2 or 3
(2)
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
REP=Riveted
Endplates
Packaging
U=Unit Pack
PAL=Job Pack,
out of carton
PALC=Job Pack,
in carton
ER8 =T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
High Performance T8 Ballasts
HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%.
Standard Ballast Factor .86 – .88
HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%.
Low Ballast Factor .77 – .82
HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%.
Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%.
High Ballast Factor 1.15 – 1.20
HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%.
Standard Ballast Factor .86 – .88
HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%.
Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%.
Low Ballast Factor .71 – .79
HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%.
High Ballast Factor 1.15 – 1.20
NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for all
(3)
(4)
9/16" ceiling systems. Four required per fixture. Standard off-center ballast on 3-lamp fixtures. Products also available
(5)
in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must
(7)
(8)
be specific. Specify row configuration, type in catalog number when ordering complete fixture. Fixtures equipped
(9)
with “EL” option may require a 5-1/2" housing depth. If installing in field, must use low profile battery pack. Louver is
recessed by 5/16" in Concealed T or Slot Grid T.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change
without notice. Consult your Cooper Lighting Representative for availability and ordering information.
Options
PAF=Painted
After Fabrication
ACCESSORIES
EQ-CLIP-U=T-BAR Safety
Earthquake Clips(2)
SH IP P ING D A T A
Catalog No.
2P2GAX-328T8S36I
2P2GAX-332S36I
2P2GAX-328T8S38I
2P2GAX-332S38I
Wt.
42 lbs.
42 lbs.
42 lbs.
42 lbs.
ADF090386
2015-10-13 15:59:17
Download