Metalux D ES C R IPTION The Paralux II Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a 2" precision cell louver into a 4-3/4" deep para-contoured fixture housing. This combination creates a total low profile parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The low profile luminaire is designed to offer the market-place a parabolic choice when economics and shallow plenum space are factors. The Paralux II series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l* * H inging/Latching 4-3/4" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Full length die formed stiffeners for added strength. Contoured ballast/ wireway cover, easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates, securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have integral Grid-Lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. Positive cam action spring loaded, self locking, black steel latches. Safety lock T-hinges allow hinging and latching either side. Louver F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Die formed of semi-specular aluminum. Finish is anodic oxide coating. Accurate precision parabolic cells are held in place by interlocking feature. True-cut mitered corners. Black reveal with mechanical light seal around entire perimeter of louver. Louver protected by polyethylene cover. 4-3/4" [121mm] 2P2GAX 228T8 428T8 232 432 12, 16, 24 or 32 Cell 2' X 4' PARABOLIC 2 OR 4 T8 LAMP SEMI-SPECULAR LOUVER 23-3/4" [603mm] Paralux II Recessed Air Supply Troffer MOUNTING D A TA 2/4 LAMP L A MP CONF IGURA T IONS 2 LAMP – 12/16 CELL Access Plate 7/8" [22mm] 7/8" [22mm] K.O. (2) 4-3/4" [121mm] 2" [51mm] 10-3/16" [259mm] 23-3/4" [603mm] 23-3/4" [603mm] ENERGY DATA 4 LAMP – 24/32 CELL Input Watts: EB Ballast & STD Lamps 228T8 (48), 428T8 (93), 232 (55), 432 (113) 4-3/4" [121mm] 2" [51mm] X=4-3/4" [121mm] 4-5/8" [119mm] 3" [77mm] 48" [1217mm] 7-7/8" [201mm] X X 5-3/4" [146mm] 23-3/4" [603mm] Luminaire Efficacy Rating LER = FP-64 Catalog Number: 2P2GAX-232S28I Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.75 CEI LING C OM PA TIB I L I T Y G Grid/Lay-in Standard G Concealed T G Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements." LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS (Verify compatibility/ consult factory.) Safe and convenient means of disconnecting power. ADF090236 2015-10-13 15:43:46 2P 2 GAX 2 OR 4 L T 8 PH OTOM ETR IC S Candlepower 2P2GAX-232S28I Electronic Ballast F32T8/35K lamps 2900 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.7 x mounting height Efficiency = 77% Test Report: 2P2GX232S28IPAF.IES LER = FP-64 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.75 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1475 1466 1443 1405 1354 1294 1223 1141 1045 934 805 651 470 264 91 36 15 5 0 Across ⊥ 1475 1505 1512 1507 1493 1502 1522 1572 1686 1709 1501 1156 716 288 144 61 10 4 0 45° 1475 1487 1487 1470 1438 1392 1356 1327 1296 1265 1213 1050 755 432 156 36 12 4 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 92 83 74 66 59 52 47 42 37 33 30 92 80 70 61 53 46 40 35 31 27 24 92 78 66 57 49 41 36 31 26 22 20 90 84 77 71 66 60 55 50 46 42 39 90 81 73 65 58 52 46 41 37 33 29 90 79 69 60 53 46 40 35 30 26 23 90 76 65 56 48 41 35 31 26 22 19 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 1203 2048 3896 4314 4314 %Lamp 21.5 36.6 69.6 77.0 77.0 F32T8/35K lamps 2900 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency = 68.3% Test Report: 2P2GX432S48IPAF.IES LER = FP-63 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.81 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 3204 3184 3130 3046 2936 2803 2647 2466 2255 2012 1729 1398 1019 585 197 73 29 8 0 Across ⊥ 3204 3225 3249 3342 3484 3597 3520 3058 2384 1818 1422 1037 565 319 51 26 13 5 0 45° 3204 3202 3190 3166 3165 3167 3149 3032 2759 2261 1673 1152 730 392 142 34 15 6 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 92 86 79 73 67 62 56 52 47 43 40 Candlepower 2P2GAX-432S48I Electronic Ballast %Fixture 27.9 47.5 90.3 100.0 100.0 20% 50% 50 30 10 30% 50 30 10 50 86 78 70 63 56 50 45 40 36 32 29 82 75 68 61 55 49 43 39 35 31 28 79 72 65 59 53 47 42 38 34 30 27 86 76 67 59 51 45 39 34 30 26 23 86 74 64 55 48 41 35 30 26 22 19 82 73 65 57 50 44 39 34 30 26 23 82 72 63 54 47 40 35 30 26 22 19 10% 30 10 79 71 63 56 49 43 38 33 29 25 23 79 70 61 53 46 40 35 30 26 22 19 0% 0 77 68 60 52 45 38 33 28 24 20 18 Ty p i c a l VC P Pe r c e n t a g e s Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Along 8.5’ 10.0’ 79 76 85 81 87 84 87 84 88 87 Height Across 8.5’ 10.0’ 74 71 82 77 85 81 82 80 86 84 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 81 76 71 66 61 57 52 48 45 41 38 81 74 67 61 55 49 44 40 36 32 29 81 72 63 56 50 44 39 35 31 27 24 81 70 61 53 46 40 35 31 27 23 21 79 75 70 65 60 55 51 47 44 40 37 79 72 66 60 54 48 44 40 36 32 29 79 79 70 69 63 60 56 52 49 46 44 40 39 35 34 31 30 27 27 23 24 21 20% 50% 50 30 10 30% 50 30 10 50 76 70 63 58 52 47 43 39 35 31 28 73 67 61 56 51 46 42 38 34 30 28 70 65 59 54 49 45 41 37 33 30 27 76 68 61 54 48 43 38 34 30 26 24 76 67 59 51 45 39 35 31 27 23 21 73 66 59 53 47 42 38 34 30 26 23 73 65 57 51 45 39 35 30 27 23 20 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens 2675 4470 7166 7648 7648 %Lamp 23.9 39.9 64.0 68.3 68.30 %Fixture 35.0 58.4 93.7 100.0 100.0 10% 30 10 70 64 58 52 46 41 37 33 29 26 23 Height Along 8.5’ 10.0’ 73 68 79 75 83 78 81 77 85 81 70 63 56 50 44 39 34 30 26 23 20 0% 0 68 61 55 49 43 37 33 29 25 22 19 Height Across 8.5’ 10.0’ 82 76 87 81 89 85 89 85 90 88 ORDER ING INFOR M A TION SAMPLE NUMBER: 2P2GAX-232S26I-UNV-EB81-U Rating Blank= Standard ATW-SW4= Chicago Rated HR=Heat Removal (1) Width 2=2' Width P=Paralux Louver 2=2" Louver Depth Trim Type G=Grid/Lay-in (Standard) G=Concealed T/Slot Grid (7) F=Aluminum Flange Trim (6) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4) Number of Lamps 2 or 4 lamps Wattage (Length) 28T8=28W T8 (48") 32=32W T8 (48") Louver Color S=Silver W=White Cell Configuration 26=2 Rows of 6, 12 Cell (2' x 4') 28=2 Rows of 8, 16 Cell (2' x 4') 46=4 Rows of 6, 24 Cell (2' x 4') 48=4 Rows of 8, 32 Cell (2' x 4') Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard MI=Specular/Mirrored (Low Iridescent) P=Painted Option – Aluminum Flange Trim (6) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row (1) Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (5) Lamps Installed Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K L8841=T8 Lamp, 28W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% No. of High Ballast Factor >1.15 Ballast 1, 2 or 3 (2) Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information. Specifications and dimensions subject to change without notice. Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ACCESSORIES EQ-CLIP-U=T-BAR Safety ER8 =T8 Electronic Program Rapid Start. Earthquake Clips (2) Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. (3) (4) Products also available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be specific. (5) (6) Fixtures equipped with “EL” option may require a 5-1/2" housing depth. If installing in field, must use low profile battery pack. Specify row configuration, type in (7) catalog number when ordering complete fixture. Louver is recessed by 5/16" in Concealed T or Slot Grid T. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Options PAF=Painted After Fabrication REP=Riveted Endplates SH IP P ING D A T A Catalog No. 2P2GAX-228T8S26I 2P2GAX-232S26I 2P2GAX-228T8S28I 2P2GAX-232S28I 2P2GAX-428T8S46I 2P2GAX-432S46I 2P2GAX-428T8S48I 2P2GAX-432S48I Wt. 42 lbs. 42 lbs. 42 lbs. 42 lbs. 42 lbs. 42 lbs. 42 lbs. 42 lbs. ADF090236 2015-10-13 15:43:46