D ES C R IPTION
The Paralux II Series features recessed aesthetics and the latest in energy
efficient technology. The luminaire incorporates a 2" precision cell louver
into a 4-3/4" deep para-contoured fixture housing. This combination
creates a total low profile parabolic optical assembly for optimum
performance. The series is compatible with all of today’s popular ceiling
systems and is available with a number of options and accessories for
application versatility. The low profile luminaire is designed to offer
the market-place a parabolic choice when economics and shallow
plenum space are factors. The Paralux II series is an excellent choice
for commercial office spaces, schools, hospitals or retail merchandising
areas.
Type
Catalog #
Project
Date
Comments
Prepared by
SPE C IFIC A TION FEA T U R E S
C on s t r u c t i o n
E le ctrica l* *
H inging/Latching
4-3/4" deep, para-contoured
housing, die formed code gauge,
prime cold rolled steel. Full length
die formed stiffeners for added
strength. Contoured ballast/
wireway cover, easily removed
without tools. Die formed captive
lampholder bracket fully encloses
lampholder wiring permitting easy
lampholder replacement. Heavy
end plates, securely attached with
interlocking tabs and screws. Four
auxiliary fixture end suspension
points provided. KOs for
continuous row wiring. End plates
have integral Grid-Lock feature for
safety and convenience.
Ballasts are CBM/ETL Class “P” and
are positively secured by mounting
bolts. Pressure lock lampholders.
UL/CUL listed. Suitable for damp
locations.
Positive cam action spring loaded,
self locking, black steel latches.
Safety lock T-hinges allow hinging
and latching either side.
Louver
F in ish
Lighting grade, baked white
enamel finish. Multistage, iron
phosphate pretreatment ensures
maximum bonding and rust
inhibition.
Die formed of semi-specular
aluminum. Finish is anodic oxide
coating. Accurate precision
parabolic cells are held in place
by interlocking feature. True-cut
mitered corners. Black reveal
with mechanical light seal around
entire perimeter of louver. Louver
protected by polyethylene cover.
4-3/4"
[121mm]
2P2GAX
228T8
428T8
232
432
12, 16, 24 or 32
Cell
2' X 4' PARABOLIC
2 OR 4 T8 LAMP
SEMI-SPECULAR LOUVER
23-3/4"
[603mm]
Paralux II
Recessed Air Supply Troffer
MOUNTING D A TA
2/4 LAMP
L A MP CONF IGURA T IONS
2 LAMP – 12/16 CELL
Access Plate
7/8" [22mm]
7/8" [22mm] K.O. (2)
4-3/4"
[121mm]
2"
[51mm]
10-3/16"
[259mm]
23-3/4" [603mm]
23-3/4"
[603mm]
ENERGY DATA
4 LAMP – 24/32 CELL
Input Watts:
EB Ballast & STD Lamps
228T8 (48), 428T8 (93),
232 (55), 432 (113)
4-3/4"
[121mm]
2"
[51mm]
X=4-3/4"
[121mm]
4-5/8" [119mm]
3" [77mm]
48" [1217mm]
7-7/8" [201mm]
X
X
5-3/4"
[146mm]
23-3/4" [603mm]
Luminaire Efficacy Rating
LER = FP-64
Catalog Number: 2P2GAX-232S28I
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.75
CEI LING C OM PA TIB I L I T Y
G
Grid/Lay-in
Standard
G
Concealed T
G
Slot Grid
F
Aluminum Flange Trim
With Supporting
Swing Gates
MZ
Modular Trim
With Supporting
Swing Gates
Ceiling
Type
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
Concealed “T” or ”Z“
Metal Pan
G
G
G
F
MZ
MZ
**Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements."
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
(Verify compatibility/ consult
factory.)
Safe and convenient means of
disconnecting power.
ADF090236
2015-10-13 15:43:46
2P 2 GAX 2 OR 4 L T 8
PH OTOM ETR IC S
Candlepower
2P2GAX-232S28I
Electronic Ballast
F32T8/35K lamps
2900 lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.7 x
mounting height
Efficiency = 77%
Test Report:
2P2GX232S28IPAF.IES
LER = FP-64
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.75
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
1475
1466
1443
1405
1354
1294
1223
1141
1045
934
805
651
470
264
91
36
15
5
0
Across ⊥
1475
1505
1512
1507
1493
1502
1522
1572
1686
1709
1501
1156
716
288
144
61
10
4
0
45°
1475
1487
1487
1470
1438
1392
1356
1327
1296
1265
1213
1050
755
432
156
36
12
4
0
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
92
83
74
66
59
52
47
42
37
33
30
92
80
70
61
53
46
40
35
31
27
24
92
78
66
57
49
41
36
31
26
22
20
90
84
77
71
66
60
55
50
46
42
39
90
81
73
65
58
52
46
41
37
33
29
90
79
69
60
53
46
40
35
30
26
23
90
76
65
56
48
41
35
31
26
22
19
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
0-180
Lumens
1203
2048
3896
4314
4314
%Lamp
21.5
36.6
69.6
77.0
77.0
F32T8/35K lamps
2900 lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.4 x
mounting height
Efficiency = 68.3%
Test Report:
2P2GX432S48IPAF.IES
LER = FP-63
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.81
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
3204
3184
3130
3046
2936
2803
2647
2466
2255
2012
1729
1398
1019
585
197
73
29
8
0
Across ⊥
3204
3225
3249
3342
3484
3597
3520
3058
2384
1818
1422
1037
565
319
51
26
13
5
0
45°
3204
3202
3190
3166
3165
3167
3149
3032
2759
2261
1673
1152
730
392
142
34
15
6
0
Coefficients of Utilization
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
92
86
79
73
67
62
56
52
47
43
40
Candlepower
2P2GAX-432S48I
Electronic Ballast
%Fixture
27.9
47.5
90.3
100.0
100.0
20%
50%
50 30 10
30%
50 30 10
50
86
78
70
63
56
50
45
40
36
32
29
82
75
68
61
55
49
43
39
35
31
28
79
72
65
59
53
47
42
38
34
30
27
86
76
67
59
51
45
39
34
30
26
23
86
74
64
55
48
41
35
30
26
22
19
82
73
65
57
50
44
39
34
30
26
23
82
72
63
54
47
40
35
30
26
22
19
10%
30 10
79
71
63
56
49
43
38
33
29
25
23
79
70
61
53
46
40
35
30
26
22
19
0%
0
77
68
60
52
45
38
33
28
24
20
18
Ty p i c a l VC P Pe r c e n t a g e s
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Height Along
8.5’
10.0’
79
76
85
81
87
84
87
84
88
87
Height Across
8.5’
10.0’
74
71
82
77
85
81
82
80
86
84
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
81
76
71
66
61
57
52
48
45
41
38
81
74
67
61
55
49
44
40
36
32
29
81
72
63
56
50
44
39
35
31
27
24
81
70
61
53
46
40
35
31
27
23
21
79
75
70
65
60
55
51
47
44
40
37
79
72
66
60
54
48
44
40
36
32
29
79 79
70 69
63 60
56 52
49 46
44 40
39 35
34 31
30 27
27 23
24 21
20%
50%
50 30 10
30%
50 30 10
50
76
70
63
58
52
47
43
39
35
31
28
73
67
61
56
51
46
42
38
34
30
28
70
65
59
54
49
45
41
37
33
30
27
76
68
61
54
48
43
38
34
30
26
24
76
67
59
51
45
39
35
31
27
23
21
73
66
59
53
47
42
38
34
30
26
23
73
65
57
51
45
39
35
30
27
23
20
Zonal Lumen Summary
Ty p i c a l VC P Pe r c e n t a g e s
Zone
0-30
0-40
0-60
0-90
0-180
Room Size (Ft.)
20 x 20
30 x 30
30 x 60
60 x 30
60 x 60
Lumens
2675
4470
7166
7648
7648
%Lamp
23.9
39.9
64.0
68.3
68.30
%Fixture
35.0
58.4
93.7
100.0
100.0
10%
30 10
70
64
58
52
46
41
37
33
29
26
23
Height Along
8.5’
10.0’
73
68
79
75
83
78
81
77
85
81
70
63
56
50
44
39
34
30
26
23
20
0%
0
68
61
55
49
43
37
33
29
25
22
19
Height Across
8.5’
10.0’
82
76
87
81
89
85
89
85
90
88
ORDER ING INFOR M A TION
SAMPLE NUMBER: 2P2GAX-232S26I-UNV-EB81-U
Rating
Blank=
Standard
ATW-SW4=
Chicago
Rated
HR=Heat
Removal (1)
Width
2=2' Width
P=Paralux Louver
2=2" Louver Depth
Trim Type
G=Grid/Lay-in (Standard)
G=Concealed T/Slot Grid (7)
F=Aluminum Flange Trim (6)
MZ=Modular Trim
AX=Air Supply Floating Louver
X=Blank Side/Floating Louver Non-Air Supply (Omit A)
AVX=Air Supply Floating Louver
with Directional Air Vane (Add V)
Voltage (3)
120V=120 Volt
277V=277 Volt
347V=347 Volt
UNV=Universal
Voltage 120-277 (4)
Number
of Lamps
2 or 4 lamps
Wattage (Length)
28T8=28W T8 (48")
32=32W T8 (48")
Louver Color
S=Silver
W=White
Cell Configuration
26=2 Rows of 6, 12 Cell (2' x 4')
28=2 Rows of 8, 16 Cell (2' x 4')
46=4 Rows of 6, 24 Cell (2' x 4')
48=4 Rows of 8, 32 Cell (2' x 4')
Louver Finish
I=Semi-Specular/Haze (Low Iridescent)
Standard
MI=Specular/Mirrored (Low Iridescent)
P=Painted
Option – Aluminum Flange Trim (6)
Blank=SW (Single White)
Type
Color
‘S’ Single
‘N’ Natural
‘R’ In Row
‘W’ White
‘E’ End of Row
(1)
Options
GL=Single Element
Fuse
GM=Double Element
Fuse
WTR=White Reveal
Flex=Flex Installed
(Reference Flex ordering information)
EL=Emergency
Installed (5)
Lamps Installed
Blank=No Lamps
Installed
L8835=T8 Lamp, 28W
and 32W, 3500K
L8841=T8 Lamp, 28W
and 32W, 4100K
L8835HL=T8 Lamp,
32W, 3500K, 3100
Lumens
L8841HL=T8 Lamp,
32W, 4100K, 3100
Lumens
Ballast Type
EB8 =T8 Electronic Start.
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EB8 /PLUS= T8 Electronic Start.
Total Harmonic Distortion < 10%
No. of
High Ballast Factor >1.15
Ballast
1, 2 or 3
(2)
Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information.
Specifications and
dimensions subject to
change without notice.
Packaging
U=Unit Pack
PAL=Job Pack,
out of carton
PALC=Job Pack,
in carton
ACCESSORIES
EQ-CLIP-U=T-BAR Safety
ER8 =T8 Electronic Program Rapid Start.
Earthquake Clips (2)
Total Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
High Performance T8 Ballasts
HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%.
Standard Ballast Factor .86 – .88
HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%.
Low Ballast Factor .77 – .82
HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%.
Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%.
High Ballast Factor 1.15 – 1.20
HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%.
Standard Ballast Factor .86 – .88
HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%.
Step Dimming. Ballast Factor .88
HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%.
Low Ballast Factor .71 – .79
HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%.
High Ballast Factor 1.15 – 1.20
NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture.
(3)
(4)
Products also available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must be specific.
(5)
(6)
Fixtures equipped with “EL” option may require a 5-1/2" housing depth. If installing in field, must use low profile battery pack. Specify row configuration, type in
(7)
catalog number when ordering complete fixture. Louver is recessed by 5/16" in Concealed T or Slot Grid T.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Options
PAF=Painted After
Fabrication
REP=Riveted
Endplates
SH IP P ING D A T A
Catalog No.
2P2GAX-228T8S26I
2P2GAX-232S26I
2P2GAX-228T8S28I
2P2GAX-232S28I
2P2GAX-428T8S46I
2P2GAX-432S46I
2P2GAX-428T8S48I
2P2GAX-432S48I
Wt.
42 lbs.
42 lbs.
42 lbs.
42 lbs.
42 lbs.
42 lbs.
42 lbs.
42 lbs.
ADF090236
2015-10-13 15:43:46
Download