Metalux D ES C R IPTION The Paralux III Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a nominal 3" deep precision cell louver into a 4-3/4" deep para-contoured fixture housing. This combination creates a total high performance parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. Catalog # 2EP3-IC is rated for installations when the housing is in direct contact with insulation. The high performance luminaire is designed to offer maximum efficiency and performance for today’s unique interior specifications. Prepared by Type Project Date Comments SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l* * H inging/Latching 4-3/4" deep, para-contoured housing, die formed of code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Contoured ballast/ wireway cover is easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have labor saving integral Grid-Lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed for Type IC Recessed Luminaire (Rated for direct contact with insulation) Suitable for damp locations. Positive spring loaded, self locking, steel latches. Safety lock T-hinges allow hinging and latching from either side. F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Louver Die formed of low iridescent, vertical grain anodized aluminum. Finish is Anodic oxide coating. Accurate precision parabolic cells are held in place with interlocking feature. True-cut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by polyethylene cover. 2EP3GAX-IC 228T8 428T8 232 432 12, 16, 24, 32 Cell 4-3/4" [121mm] Paralux III Recessed Static or Air Supply Troffer For Use in Insulated Ceilings 23-3/4" [603mm] MO UNTING D A TA 2/4 LAMP 2' X 4' PARABOLIC 2 OR 4 T8 LAMPS SEMI-SPECULAR, SPECULAR OR WHITE PAINTED LOUVER L A MP CONF IGURA T IONS Access Plate 7/8" [22mm] 7/8" [22mm] K.O. (2) 2 LAMP – 12/16 CELL 4-3/4" [121mm] 2-5/8" [67mm] 10-3/16" [259mm] 23-3/4" [603mm] 23-3/4" [603mm] ENERGY DATA 4 LAMP – 24/32 CELL Input Watts: EB Ballast & STD Lamps 228T8 (48), 428T8 (93) 232 (55), 423 (113) 4-3/4" [121mm] 2-5/8" [67mm] X=4-3/4" [121mm] 4-5/8" [119mm] 3" [77mm] 48" [1217mm] 7-7/8" [201mm] X X 5-3/4" [146mm] 23-3/4" [603mm] **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. C EILING C OM PA TIB IL I T Y G Grid/Lay-in Standard G Concealed T G Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ (Verify compatibility/ consult factory.) LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF110376 2015-10-13 12:52:09 2 E P 3 GAX-IC T B PH OTOM ETR IC S 2EP3GX-IC-232S28I Electronic Ballast Candlepower Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 F32T8/35K Lamps 3100 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.5 x mounting height Efficiency 69.7% Test Report: 2EP3-IC-232S28I Along II 1467 1466 1439 1397 1342 1279 1206 1121 1024 922 815 697 555 362 165 68 32 11 0 Across ⊥ 1467 1480 1492 1486 1464 1443 1433 1444 1455 1425 1415 1452 1050 549 312 156 53 16 0 45° 1467 1471 1464 1442 1399 1342 1283 1226 1170 1114 1043 951 808 503 190 80 36 13 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 83 74 65 57 50 45 40 36 33 30 28 83 71 60 52 44 39 34 30 27 25 22 83 69 57 47 40 34 30 26 23 21 19 81 75 68 62 57 52 48 45 41 39 36 81 72 63 56 49 44 40 36 33 30 28 81 70 59 51 44 38 34 30 27 24 22 81 68 56 47 40 34 30 26 23 21 19 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 1172 1958 3722 4319 4319 %Lamp 18.9 31.6 60.0 69.7 69.7 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 F32T8/35K Lamps 3100 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height Efficiency 65.6% Test Report: 2EP3-IC-432S46I Along II 3068 3070 3025 2948 2845 2718 2574 2404 2207 1993 1765 1515 1232 896 486 163 69 24 0 Across ⊥ 3068 3101 3148 3204 3216 3169 3050 2920 2596 2188 1829 1624 1360 753 336 134 53 15 0 45° 3068 3085 3080 3066 3031 2954 2838 2682 2464 2172 1767 1360 1050 745 371 140 60 20 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 83 77 70 64 58 54 49 46 42 40 37 Candlepower 2EP3GX-IC-432S46I Electronic Ballast %Fixture 27.1 45.3 86.2 100.0 100.0 20% 50% 50 30 10 30% 50 30 10 50 77 69 61 54 48 43 38 35 32 29 27 74 67 59 52 46 41 37 34 31 28 26 71 64 57 50 45 40 36 33 30 28 26 77 67 58 50 43 38 33 30 27 24 22 77 65 55 46 39 34 29 26 23 21 19 74 65 56 48 42 37 33 29 26 24 22 74 63 53 45 39 33 29 26 23 20 18 10% 30 10 71 63 54 47 41 36 32 29 26 23 21 71 62 52 44 38 33 29 25 23 20 18 0% 0 70 60 51 43 37 32 27 24 21 19 17 Typical VCP Percentages Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Along 8.5’ 10.0’ 74 72 78 75 81 78 82 80 83 81 Height Across 8.5’ 10.0’ 67 65 73 68 75 71 78 74 79 76 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 78 72 67 61 56 52 48 44 41 39 36 78 70 62 55 49 44 40 36 33 30 28 78 67 58 50 44 38 34 30 27 25 23 78 65 55 46 39 34 30 27 24 21 19 76 71 65 60 55 50 47 43 40 38 35 76 68 61 54 48 43 39 35 32 30 27 76 66 57 49 43 38 34 30 27 25 23 76 64 54 46 39 34 30 26 24 21 19 20% 50% 50 30 10 30% 50 30 10 50 73 66 58 52 46 42 38 34 31 29 27 70 63 56 50 45 41 37 33 31 28 26 67 61 54 49 44 39 36 33 30 28 26 73 64 55 48 42 37 33 30 27 24 22 73 62 53 45 39 34 30 26 24 21 19 70 62 54 47 41 36 33 29 26 24 22 70 60 51 44 38 33 29 26 23 21 19 Zonal Lumen Summary Typical VCP Percentages Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens 2523 4191 7169 8136 8136 %Lamp 20.3 33.8 57.8 65.6 65.6 %Fixture 31.0 51.5 88.1 100.0 100.0 Height Along 8.5’ 10.0’ 60 59 66 62 69 65 72 69 73 70 10% 30 10 67 60 52 46 40 36 32 29 26 24 22 67 59 50 43 38 33 29 26 23 21 19 0% 0 66 57 49 42 36 32 28 25 22 20 18 Height Across 8.5’ 10.0’ 62 61 68 64 71 67 74 70 76 72 ORDER ING INFOR M A TION SAMPLE NUMBER: 2EP3GAX-IC-232S26I-120V-EB81-U Rating Blank= Standard ATW-SW4= Chicago Rated HR=Heat Removal (1) Width 2=2' Width EP=Paralux Louver 3=3" Louver Depth Trim Type G=Grid/Lay-in (Standard) G=Concealed T/Slot Grid (6) F=Aluminum Flange Trim (7) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) IC=IC Rated Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4) Number of Lamps 2 or 4 lamps Wattage (Length) 28T8=28W T8 (48") 32=32W T8 (48") Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (5) Louver Color S=Silver W=White Cell Configuration 26=2 Rows of 6, 12 Cell 28=2 Rows of 8, 16 Cell 46=4 Rows of 6, 24 Cell 48=4 Rows of 8, 32 Cell Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard (Silver Only) MI=Specular/Mirrored (Low Iridescent) (Silver Only) P=Painted (White only) Option – Aluminum Flange Trim (7) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row (1) Lamps Installed Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K L8841=T8 Lamp, 28W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens (2) NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for all 9/16" (3) ceiling systems. Four required per fixture. Products also available in non-US voltages and frequencies for international (4) (5) markets. Not available when specifying emergencies, voltage must be specific. Fixtures equipped with “EL” option may (6) require a 5-1/2" housing depth. If installing in field, must use low profile battery pack. Louver is recessed by 5/16" in (7) Concealed T or Slot Grid T. Specify row configuration, type in catalog number when ordering complete fixture. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% No. of High Ballast Factor >1.15 Ballast 1, 2 or 3 Options PAF=Painted After Fabrication REP=Riveted Endplates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 ACCESSORIES SH IP P ING D A T A EQ-CLIP-U=T-BAR Safety Earthquake Clips(2) Catalog No. 2EP3GAX-IC-228T8S261 2EP3GAX-IC-232S261 2EP3GAX-IC-428T8S461 2EP3GAX-IC-432S461 Wt. 42 lbs. 42 lbs. 42 lbs. 42 lbs. ADF110376 2015-10-13 12:52:09