The 2HP3-IC is an energy saving solution for a multitude... tions. It uses a high performance T8 system that can...

advertisement
COOPER LIGHTING - METALUX
®
DESCRIPTION
The 2HP3-IC is an energy saving solution for a multitude of applications. It uses a high performance T8 system that can save up to
40% of energy costs when compared to standard 3-lamp, 18-cell parabolics. The 2HP3-IC incorporates a nominal 3" high 12-cell precision formed louver into a nominal 4-3/4" deep pre-painted housing.
This combination creates a soft, even distribution while delivering
a highly efficient T8 luminaire. The luminaire is compatible with all of
today’s popular ceiling systems and is Type IC rated for installations
when the housing is in direct contact with insulation. The 2HP3-IC
series is an excellent choice for commercial office spaces, schools,
hospitals or retail merchandising areas.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
Construction
E l e c t r i c a l **
Louver
Die formed 4-3/4" deep para-contoured housing made from code
gauge, cold rolled steel. Housing
features die formed stiffeners for
added rigidity along with end
plates that securely attach to
housing via interlocking tabs.
Other housing features include a
Grid to T-option (or vice versa)
that allows you to do a conversion in the field. End plates also
have an integral Grid-Lock feature
for safety and convenience. A
contoured ballast/wireway cover
rests in the center of the housing
and can be easily removed without tools, while die formed captive lamp holders encloses lampholder wiring for easy lampholder replacement.
Ballasts are CBM/ETL Class “P”
are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. for Type
IC Recessed Luminaire (Rated for
direct contact with insulation)
Suitable for damp locations.
Die formed high reflectance white
aluminum (standard). Silver with
semi-specular finish (optional).
Accurate precision parabolic cells
are held in place by interlocking feature. True-cut mitered corners. Black
reveal with mechanical light seal
around entire perimeter of louver.
Louver protected by
polyethylene cover.
Finish
High reflectance white pre-paint
(standard). Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition.
H i n g i n g / L a t ch i n g
Positive cam action spring
loaded, self locking, black steel
latches with safety lock T-hinges
allow hinging and latching from
either side.
2HP3-IC
228T8
328T8
232
332
Controls
Fifth Light ballast options are
offered for both 0-10V continuous
dimming and DALI applications.
Combine with energy-saving
products like occupancy sensors,
daylighting controls, and lighting
relay panels from Cooper Controls
(www.coopercontrol.com) to maximize energy savings.
12, 18 Cell
2' X 4' PARABOLIC
2 OR 3 LAMP
HIGH PERFORMANCE T8
FOR USE IN
INSULATED CEILINGS
4-3/4"
[121mm]
23-3/4"
[603mm]
ENERGY DATA
MOUNTING DATA
Input Watts:
HB Ballast & STD Lamps
228T8 (48), 328T8 (71)
232 (53), 332 (80)
See page 2
Luminaire Efficacy Rating
LER = FP-78
Catalog Number: 2HP3-IC-232W26P
LAMP CONFIGURATIONS
See page 2
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.09
**Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
CEILING COMPATIBILITY
G
Grid/Lay-in
Standard
G
Concealed T
G
Slot Grid
F
Aluminum Flange Trim
With Supporting
Swing Gates
MZ
Modular Trim
With Supporting
Swing Gates
Ceiling
Type
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
Concealed “T” or ”Z“
Metal Pan
G
G
G
F
MZ
MZ
(Verify compatibility/ consult
factory.)
COOPER LIGHTING
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO
LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF110357
2HP3-IC- 2’X4’
PHOTOMETRICS
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
2HP3-IC-332S36IHB82
Electronic Ballast
FO32T8/35K Lamps
3100 Lumens
Spacing criterion:
(II) 1.3 x mounting
height, (⊥) 1.5 x
mounting height
Efficiency 76.5%
Test Report:
220P221
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
91
84
78
71
65
60
56
51
91
81
72
64
57
51
46
42
91
79
67
58
50
44
39
35
91
76
63
53
46
40
35
31
48 38 32 27
45 35 29 24
42 32 26 22
89
82
76
69
64
59
54
50
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
81
73
65
58
52
47
42
39
89
80
71
63
56
50
45
41
89
77
66
57
50
44
39
35
89
75
63
53
45
39
34
30
85
76
68
60
54
48
44
40
85
74
64
56
49
43
38
34
85
72
61
52
45
39
34
30
47 37
44 34
41 32
31
28
26
27
24
22
36
33
31
31 27
28 24
26 22
81
72
62
54
48
42
38
34
81
70
60
51
44
39
34
30
78
71
63
56
51
46
41
38
78
68
59
50
44
38
34
30
77
67
57
49
42
37
32
28
35 30
33 28
30 25
27
24
22
35 30 27
32 27 24
29 25 22
25
23
21
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
%Lamp
%Fixture
2129
3559
6283
7115
7115
22.9
38.3
67.6
76.5
76.5
29.9
50.0
88.3
100.0
100.0
Average
0-Deg
cd/sm
3968
3741
3018
846
381
78
69
61
53
47
41
37
33
Average
45-Deg
cd/sm
4653
4100
2198
814
362
Average
90-Deg
cd/sm
5350
3655
2468
859
285
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
2582
2588
2554
2492
2406
2300
2179
2036
1872
1692
1500
1294
1056
769
400
132
58
20
0
45°
2582
2600
2610
2601
2557
2485
2394
2277
2133
1984
1801
1418
928
560
309
127
54
19
0
Across⊥
2582
2619
2668
2695
2696
2673
2614
2517
2546
2281
1798
1264
911
629
358
134
52
15
0
LER = FP-78
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.07
MOUNTING DATA
2 LAMP
Access Plate
7/8" [22mm]
7/8" [22mm] K.O. (2)
23-3/4"
[603mm]
3 LAMP
Access Plate
7/8" [22mm] K.O.
7/8" [22mm] K.O. (4)
23-3/4"
[603mm]
4-5/8" [119mm]
3" [77mm]
48" [1217mm]
3" [77mm]
7-7/8" [201mm]
4-5/8" [119mm]
48" [1217mm]
7-7/8" [201mm]
LAMP CONFIGURATIONS
3 LAMP – 18 CELL
2 LAMP – 12 CELL
4-3/4"
[121mm]
4-3/4"
[121mm]
2-5/8"
[67mm]
10-3/16"
[259mm]
23-3/4" [603mm]
2-5/8"
[67mm]
7"
7"
[178mm] [178mm]
23-3/4" [603mm]
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
4/13
ADF110357
2HP3-IC- 2’X4’
ORDERING INFORMATION
Sample Number: 2HP3GX-IC-232W26P-UNV-HB81H-U
Rating
Blank=Standard
ATW-SW4=Chicago
Rated
Heat Removal
HR=Heat Removal
Louver Finish
I = Semi-Specular/
Haze(Low Iridescent)
(Silver Only)
P = Painted White
(Standard)
1
Option - 4
Aluminum Flange
Trim
Blank = SW
(Single White)
SN = Single, Natural
Finish
RN = In Row, Natural
Finish
RW= In Row, White
Finish
EN = End of Row,
Natural Finish
EW = End of Row,
White Finish
Width
2=2' Width
Series
HP3=High Performance
3" Paralux Louver
Trim Type
G=Grid/Lay-in Standard
G=Concealed T/ 9
Slot Grid
F=Aluminum 4
Flange Trim
MZ=Modular Trim
HR8 L=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Low Ballast Factor .71 – .79
HR8 H=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
High Ballast Factor 1.15 – 1.20
0-10V Dimming Ballasts 11
5LTV8 =T8 0-10V Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 0.87 14, 15
5LTVS8 =T8 0-10V Spec Grade Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 0.87 12, 13
6
Voltage
120V =120 Volt
Air Supply
AX =Air Supply
Floating Louver
277V =277 Volt
347V =347 Volt
7
X =Blank
Side/Floating
Louver - Non Air
Supply
UNV =Universal
Voltage
120-277
AVX =Air Supply
Floating
Louver
w/Directional
Air Vane
Option GL = Single Element
Fuse
GM = Double Element
Fuse
WTR= White Reveal
Flex = Flex Installed
(Reference Flex
ordering
information)
EL = Emergency Installed
Type
IC=IC Rated
Number of Lamps
2 Lamps
3 Lamps 5
Fifth Light DALI Ballasts 10
5LT8 =T8 DALI Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 1.0
Louver Color
S = Silver
W = White
Cell
Configuration
26 = 2 Rows of 6, 12
Cell (2’x4’)
36 = 3 Rows of 6, 18
Cell (2’x4’)
Number of Ballasts
1=1 Ballast
2=2 Ballast
3=3 Ballast
8
Lamps Installed
Blank = No Lamps
Installed
L8835 = T8 Lamp, 28W
and 32W. 3500K
L8841 = T8 Lamp, 28W
and 32W. 4100K
L88835HL = T8 Lamp,
32W 3500K,
3100k Lumens
L88841HL = T8 Lamp,
32W 4100K,
3100 Lumens
Wattage
28T8=28W T8 (48")
32=32W T8 (48")
Notes: 1
2
3
4
5
6
7
8
9
Ballast Type
High Performance T8 Ballasts
HB8 =T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
Standard Ballast Factor .86 – .88
HB8 L=T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
Low Ballast Factor .77 – .82
HB8 N=T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
Normal Ballast Factor 1.0
HB8 H=T8 Electronic Instant Start.
Total Harmonic Distortion < 10%.
10%.High Ballast Factor 1.15 – 1.20
HR8 T8 Electronic Program Rapid
Start. Total Harmonic Distortion < 10%.
Standard Ballast Factor .86 – .88
HR8 DIM=T8 Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Step Dimming. Ballast Factor .88
Options
RIF1 =Radio Interference
Suppressor
REP=Riveted End Plates
Packaging
U=Unit Pack
PAL=Job Pack, out of carton
PALC=Job Pack, in carton
AC C E S S O R I E S
EQ-CLIP-U=T-BAR Safety Earthquake Clips
3
Note: An EQ Grid Clip is recommended for all 9/16” ceiling systems.
Four required per fixture.
Integral End Plate Grid Lock feature not available in Heat Removal
May also be used with Concealed T or Slot Grid T. Louver will be recessed by 5/16". Housing depth = 5-1/2".
An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture.
Specify row configuration, type in catalog number when ordering complete fixtures.
Standard off-center ballast on 3 lamp fixtures.
Products also available in non-US voltage and frequencies for international markets
Not available when specifying emergencies, voltage must be specific
Fixtures equipped with "EL" option may require a 5-1/2" housing depth. If installing in field, must use low profile battery pack.
Louver is recessed by 5/16" in Concealed T or Slot Grid T.
10
For a complete listing of Fifthlight Technology products and other solutions from Cooper Controls, visit www.coopercontrol.com
11
0-10V ballast do not include DALI feature. Please select DALI ballast for use with Fifth Light system.
12
Specification grade 0-10V dimming ballast are NEMA premium and CEE listed. They are compatible with low mercury and energy saving lamps.
13
Specification Grade 0-10V ballast not offered in 3 or 4-lamp versions.
14
Standard 0-10V ballast not available for 28W T8 lamps.
15
Voltage must be specified for Standard 0-10V 32W 3 and 4-lamp ballast.
SHIPPING DATA
Catalog No.
Wt.
2HP3-IC-228T8S26P
2HP3-IC-328T8S36P
42 lbs.
42 lbs.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
4/13
ADF110357