Metalux D ES C R IPTION The Paralux III Tannenbaum louver offers designers an exciting new appearance forlow brightness recessed applications. The luminaire incorporates a unique European louver design featuring low iridescent specular and Tannenbaum aluminum optical surfaces. This louver integrates into the Paralux III 4-3/4" deep para-contoured housing for optimum performance. The Paralux III series is compatible with all of today’s popular ceiling systems and is available wotj a number of options and accessories to application versatility. Type Catalog # Project Date Comments Prepared by 2EP3-IC is rated for installations when the housing is in direct contact with insulation. It is a great visual alternative to traditional recessed luminaires and provides efficient, low glare ambient lighting. SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l* * H inging/Latching 4-3/4" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Contoured ballast/ wireway cover is easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have integral Grid-Lock feature for safety and convenience. Ballast are CBM/ETL Class “P” and positively secured. 2G11 base lampholders have doubleedge wiping action pressure lock contacts with vertically oriented lamp support clips. UL/CUL listed for Type IC Recessed Luminaire (Rated for direct contact with insulation) Suitable for damp locations. Positive spring loaded, self locking, steel latches. Safety lock T-hinges allow hinging and latching from either side. F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Louver Die formed of low iridescent anodized specular and Tannenbaum aluminum. Finish is anodic oxide coating. Accurate precision contours are held in place with interlocking feature. Trus cut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by poly cover. 2EP3GAX-IC 328T8 332 36 Cell 2' X 4' LOUVER 3 T8 LAMPS TANNENBAUM LOUVER 4-3/4" [121mm] Paralux III Recessed Static or Air Supply Troffer For Use in Insulated Ceilings 23-3/4" [603mm] ENERGY DATA MO UNTING D A TA 2/4 LAMP Input Watts: EB Ballast & STD Lamps 328T8 (67) 332 (81) L A MP CONF IGURA T IONS Access Plate 7/8" [22mm] K.O. 7/8" [22mm] K.O. (4) 3 LAMP – 36 CELL 4-3/4" [121mm] 2-5/8" [67mm] 7" 7" [178mm] [178mm] 23-3/4" [603mm] Luminaire Efficacy Rating LER = FP-61 Catalog Number: 2EP3GAX-IC332ST312MI 23-3/4" [603mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.93 4-5/8" [119mm] 3" [77mm] 48" [1217mm] **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. 7-7/8" [201mm] C EILING C OM PA TIB IL I T Y G Grid/Lay-in Standard G Concealed T G Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ (Verify compatibility/ consult factory.) LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF110377 2015-10-13 13:37:34 2 E P 3 GAX-IC T 8 TA N N EN B A U M PH OTOM ETR IC S Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 2EP3GAX-IC332ST312MI Electronic Ballast FO32/35K Lamps 2800 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.7 x mounting height Efficiency 69.0% Test Report: Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 82 77 72 66 61 56 52 48 44 40 37 82 74 67 60 54 49 44 39 35 31 28 82 72 63 56 49 43 38 34 30 26 23 82 70 60 52 45 39 34 30 26 22 19 80 75 70 65 60 55 51 47 43 39 37 80 73 66 59 54 48 43 39 35 31 28 80 71 63 55 49 43 38 34 29 26 23 80 69 60 52 45 39 34 30 26 22 19 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 77 70 64 58 52 47 42 38 34 30 27 73 67 61 56 50 45 41 37 33 29 27 70 65 59 54 49 44 40 36 32 29 26 69 62 55 48 42 37 32 28 24 21 18 77 68 61 54 48 42 37 33 29 25 23 77 67 58 51 44 39 34 30 26 22 19 73 66 59 53 47 41 37 33 29 25 22 73 65 57 50 44 38 34 29 25 22 19 Zonal Lumen Summary Typical VCP Percentages Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens %Lamp %Fixture 1812 3155 5329 5799 5799 21.6 37.6 63.4 69.0 69.0 31.2 54.4 91.9 100.0 100.0 Height Along 8.5’ 10.0’ 73 74 76 76 77 76 79 79 79 79 70 64 58 52 46 41 36 32 28 25 22 70 63 56 49 43 38 33 29 25 22 19 Height Across 8.5’ 10.0’ 79 79 84 83 86 84 87 86 88 87 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 2226 2203 2150 2078 1988 1884 1763 1624 1466 1290 1088 862 620 377 189 106 51 20 0 Across ⊥ 2226 2244 2271 2325 2370 2333 2414 2981 2788 1736 1042 767 800 158 18 9 4 1 0 45° 2226 2221 2203 2187 2171 2143 2080 1972 1982 2084 1686 1003 553 346 183 75 36 12 0 2EP3-IC-3325T312MI.IES LER = FP-61 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.93 ORDER IN G INFOR M A TION SAMPLE NUMBER: 2EP3GAX-IC-332ST312MI-UNV-EB81-U Rating Blank= Standard ATW-SW4= Chicago Rated HR=Heat Removal (1) Width 2=2' Width Voltage (4) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (5) Number of Lamps 3=3 Lamps (3) Wattage (Length) 28T8=28W T8 (48") 32=32W T8 (48") Louver Color/Type ST=Silver Tannenbaum Cell Configuration 312=3 Rows of 12, 36 Cell EP=Paralux Louver 3=3" Louver Depth Trim Type G=Grid/Lay-in (Standard) G=Concealed T/Slot Grid (6) F=Aluminum Flange Trim (7) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) Louver Finish MI=Specular/Mirrored (Low Iridescent) (Silver Only) Option – Aluminum Flange Trim (8) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row IC=IC Rated Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (6) Lamps Installed Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K L8841=T8 Lamp, 28W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens Ballast Type EB8 = T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% No. of High Ballast Factor >1.15 Ballast 1, 2 or 3 Options PAF=Painted After Fabrication REP=Riveted Endplates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 ACCESSORIES (1) (2) NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per (3) (4) (5) fixture. Standard off-center ballast on 3-lamp fixtures. Products also available in non-US voltages and frequencies for international markets. Not available (6) when specifying emergencies, voltage must be specific. Fixtures equipped with “EL” option may require a 5-1/2" housing depth. If installing in field, must (7) (8) use low profile battery pack. Louver is recessed by 5/16" in Concealed T or Slot Grid T. Specify row configuration, type in catalog number when ordering complete fixture. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. EQ-CLIP-U=T-BAR Safety Earthquake Clips(2) SH IP P ING D A T A Catalog No. Wt. 2EP3GAX-IC-328T8ST312MI 42 lbs. 2EP3GAX-IC-332ST312MI 42 lbs. ADF110377 2015-10-13 13:37:34