Metalux D ES C R IPTION The Paralux III Tannenbaum louver offers designers an exciting new appearance for low brightness recessed applications. The luminaire incorporates a unique European louver design featuring low iridescent specular and Tannenbaum aluminum optical surfaces. This louver integrates into the Paralux III deep para-contoured housing for optimum performance. The Paralux III series is compatible with all of today’s popular ceiling systems. The Paralux III Tannenbaum louver provides efficient, low glare ambient lighting appropriate for most commercial interior environments including retail, hospitals, schools, offices and other spaces. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l* * H inging/Latching Deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Full length die formed stiffeners for added strength. Ballast/wireway cover, easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates, securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have integral Grid-Lock feature for safety and convenience. Housing features enable fixture to be converted from Grid to T-option or vice versa in the field.* Ballast are CBM/ETL Class “P” and positively secured. 2G11 base lampholders have doubleedge wiping action pressure lock contacts with vertically oriented lamp support clips. UL/CUL listed. Suitable for damp locations.** Positive action specular latches. Safety lock T-hinges allow hinging and latching either side. F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Louver Die formed of low iridescent anodized specular and Tannenbaum aluminum. Finish is anodic oxide coating. Accurate precision contours are held in place with interlocking feature. Truecut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by poly cover. EP3GAX 128T8 132 228T8 232 12 Cell 6-5/8" [168mm] 1' X 4' PARABOLIC 1 OR 2 T8 LAMPS TANNENBAUM LOUVER Paralux III Recessed Static or Air Supply Troffer 11-3/4" [298mm] MO UNTING D A TA L A MP CONF IGURA T IONS ENERGY DATA Access Plate 7/8" [22mm] K.O. (2) 7/8" [22mm] K.O. (2) 1-1/2" [38mm] 11-3/4" [298mm] 2 LAMP 1 LAMP 6-5/8" [168mm] 6-5/8" [168mm] 3" [76mm] 11-3/4" [298mm] 3" [76mm] X=1-3/4" [44mm] X 11-3/4" [298mm] 5-1/4" [133mm] 3-1/2" [89mm] Input Watts: EB Ballast & STD Lamps 128T8 (27), 132 (30), 228T8 (48), 232 (55) Luminaire Efficacy Rating LER = FP-55 Catalog Number: EP3GAX232ST112MI Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.36 6-1/4" [159mm] 48" [1219mm] C EILING C OM PA TIB IL I T Y G Grid/Lay-in Standard T Concealed T T Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G or T G or T F MZ MZ (Verify compatibility/ consult factory.) *Convertibility applies to housing only. Appropriate shielding media assemblies must be utilized. **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF020488 2013-01-31 10:55:58 EP 3G A X T ANNE NB AUM PH OTOM ETR IC S Coefficients of Utilization EP3GAX-232ST112MI Electronic Ballast F32T8/35K Lamps 2800 Lumens Spacing criterion: (II) 1.1 x mounting height, (⊥) 1.5 x mounting height Efficiency 66.1% Test Report: EP3GX232ST112MI.IES rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 79 73 68 63 58 53 49 45 41 38 35 79 71 63 57 51 45 40 36 32 29 26 79 68 59 52 45 40 35 31 27 24 21 79 66 56 48 41 35 31 27 23 20 18 77 72 66 61 56 51 47 44 40 37 34 77 69 62 56 50 44 40 36 32 29 26 77 67 59 51 45 39 34 30 27 23 21 77 65 56 48 41 35 31 27 23 20 18 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 73 66 60 54 48 43 39 35 31 28 25 70 64 58 52 47 42 37 34 30 27 25 67 62 56 50 45 40 36 33 30 26 24 66 58 51 44 38 33 29 25 21 18 16 73 65 57 50 44 38 34 30 26 23 21 73 63 54 47 41 35 30 26 23 20 17 70 63 55 49 43 38 33 29 26 23 20 70 61 53 46 40 35 30 26 23 20 17 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens %Lamp %Fixture 1114 1868 3261 3704 3704 19.9 33.4 58.2 66.1 66.1 30.1 50.4 88.1 100.0 100.0 Height Along 8.5’ 10.0’ 55 55 54 53 50 49 60 59 55 53 67 60 54 48 42 37 33 29 26 23 20 67 59 52 45 40 34 30 26 23 20 17 Height Across 8.5’ 10.0’ 66 56 68 61 71 65 69 64 71 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Across ⊥ 1445 1444 1429 1392 1373 1492 1589 Along II 1445 1420 1376 1320 1252 1173 1085 45° 1445 1432 1402 1354 1289 1227 1179 991 1245 1449 891 1176 1138 787 1006 1011 678 764 1134 565 626 1184 449 624 459 333 410 234 230 155 88 34 0 177 103 55 21 0 18 9 6 2 0 66 LER = FP-55 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.36 ORDER ING INFOR M A TION SAMPLE NUMBER: EP3GAX-232ST112MI-UNV-EB81-U Rating Blank= Standard ATW-SW4= Chicago Rated Heat Removal (1) HR=Heat Removal HRDO=Heat Removal Damper Open HRDC=Heat Removal Damper Closed Series EP3=Paralux III Trim Type (2) G=Grid/Lay-in – Standard T=Concealed T/Slot Grid (3) F=Aluminum Flange Trim (6) MZ=Modular Trim Air Supply AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply AVX=Air Supply Floating Louver with Directional Air Vane Number of Lamps 1=1 Lamp 2=2 Lamps Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed Wattage 28T8=28W T8 (48") 32=32W T8 (48") Louver Color ST=Silver Tannenbaum Cell Configuration 112=1 Row of 12, 12 Cell (1'x4') Louver Finish MI=Specular/Mirrored (Low Iridescent) Option – Aluminum Flange Trim (6) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Lamps Installed Blank=No Lamps Installed L8835=T8 Lamp, 28W and 32W, 3500K L8841=T8 Lamp, 28W and 32W, 4100K L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens Voltage (4) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (5) (1) Ballast Type EB8 =T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% No. of High Ballast Factor >1.15 Ballast 1, 2 or 3 Options PAF=Painted After Fabrication REP=Riveted Endplates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 High Performance T8 Ballasts HB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HB8 L=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Low Ballast Factor .77 – .82 HB8 N=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 HR8 T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Standard Ballast Factor .86 – .88 HR8 DIM=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. Low Ballast Factor .71 – .79 HR8 H=T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10%. High Ballast Factor 1.15 – 1.20 (2) NOTES: Integral end plate grid lock feature not available in heat removal. Convertibility applies to housing only, appropriate shielding media assemblies (3) must be utilized. Fixture also adaptable with flanged or modular trims. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per (4) (5) fixture. Products also available in non-US voltages and frequencies for international markets. Not available when specifying emergencies, voltage must (6) be specific. Specify row configuration, type in catalog number when ordering complete fixture. ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(3) For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. SH IP P ING D A T A Catalog No. EP3GAX-132ST112MI EP3GAX-232ST112MI Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. Wt. 29 lbs. 29 lbs. ADF020488 2013-01-31 10:55:58