Catalog # Type

advertisement
CORELITE
DESCRIPTION
One of Corelite's latest additions to its line of architectural direct-indirect
extruded fixtures, the Loft Wall, features crisp modern lines with a concave
perf aluminum insert, which creates a subtle sparkle while offering
awareness of the light source. The Loft Wall may be mounted over standard
2"x4" J-Boxes for individual or continuous configuration using 4' and 8'
modular sections. The Loft Wall is suited for open office perimeters, private
offices, conference rooms, corridors and public spaces.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
Housing is 6063 T5 aluminum
extrusion forming a 2-1/2" angled
profile. Standard 4'-0" and 8'-0"
fixture lengths combine for
continuous runs.
D ... Reflectors
Reflector pan is painted with a
highly reflectance white powder
coat finish. Optional die-formed
side reflector is a highly specular
anodized aluminum.
B ... End Caps
Standard end caps are precision
die-cast aluminum, mechanically
attached without exposed
fasteners.
E ... Electrical
T5/T5HO fixtures are pre-wired
with quick wire connectors and use
UL listed Class P, T5/T5HO
program rapid start universal
voltage electronic ballasts, power
factor of 97% with less than 10%
THD. Fixtures and electrical
components certified to UL and
CUL standards.
C ... Louver
Semi-specular material, perforated
section is 15% open with 0.062"
diameter holes and opal diffuser.
A
C
D
E
F ... Finish
Fixture housings are standard
white using electrostatically
applied polyester powder coat
paint.
Mounting
Fixture mounts directly to existing
structure over a 2" x 4" standard
electrical box mounted horizontally
into the wall. Refer to installation
section for details.
Loft Wall
Concave Metallic
Perf
2T5
2T5HO
B
F
Wall Mount
Semi-Indirect
2-1/2"
[64mm]
Semi-Indirect
Indirect - 95.8%
Direct - 4.2%
6-7/8" [174mm]
1-3/4" [44mm]
End Cap Side View
M O D U L E S A N D D I M E N S I O N S*
48" [1219mm]
96" [2438mm]
*Dimensions do not include end caps.
ORDERING INFORMATION
Sample Number: L2W-WC-2T5-1C-UNV-SU-WA-8
Series
L2W=Loft Wall
Optics Up
S=Specular
W=White
Optics Down
C=Concave Metallic Perf
Number of
Lamps
2=2 Lamps
Lamp Type
N5=T5 Normal Output
Wiring 1
B=Battery Pack
Voltage 1
120=120V
Suspension
SU-WA=Surface/Wall Mount
T5=T5 High Output
T8=T8 Normal Output
C=Standard Circuit
D=Dimming
277=277V
347=347V
Run Length
E=Emergency
T=Nightlight
UNV=Universal
(120V277V)
Continuously Mounted
Number of Circuits
1=1 Circuit
1
2=2 Circuits
Notes: 1
Y=Daylight
Individually Mounted
Luminaires may be 4' or 8' in length
Standard row configurations over 8'
consist of 4' and 8' sections
Not all options available. Please consult your Cooper Lighting Representative for availability.
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADE090041
05/22/2009 12:50:48 PM
PHOTOMETRICS
Corelite
Candela
rc
rw
L2W-WC-2T5
(2) FP54/841/HO
4500 Lumens
Test Report
#LSI17907
70
80%
50 30
10
70
70%
50 30
50%
50 30 10
10
30%
50 30 10
10%
50 30 10
0%
0
RCR
0
78
78
78
78
67
67
67
67
47
47
47
28
28
28
11
11
11
03
1
2
3
4
71
64
59
53
67
59
52
45
65
54
46
40
62
50
42
35
61
55
50
46
58
51
45
39
56
47
40
34
53
44
37
31
41
36
31
28
39
33
29
25
38
31
26
22
25
22
19
17
24
20
18
15
23
19
16
14
10
09
08
07
10
08
07
06
09
08
07
06
03
02
02
02
5
6
7
8
49
45
41
38
39
36
32
29
34
30
26
23
30
25
22
19
42
38
35
33
35
31
28
25
30
26
23
20
26
22
19
17
25
22
20
18
21
19
16
14
19
16
14
12
15
13
12
11
13
12
10
09
12
10
09
08
06
05
05
04
05
05
04
04
05
04
04
03
01
01
01
01
9
10
35
33
26
24
20
18
17
15
30
28
23
20
18
16
15
13
16
15
13
11
11
09
10
09
08
07
07
06
04
04
03
03
03
02
01
01
Zonal Lumen Summar y
Along II
45
Across I
0
102
102
102
5
101
103
95
15
25
98
92
95
90
98
90
35
45
55
81
67
51
75
67
52
80
67
54
65
75
85
90
31
12
3
0
36
13
6
0
41
23
8
0
95
105
115
125
67
380
737
1084
146
846
1344
1618
149
792
1579
1894
135
145
155
165
175
180
1393
1656
1861
2002
2075
2082
1787
1938
2059
2110
2097
2082
2051
2099
2145
2159
2099
2082
Luminance Data
Zone
0-30
0-40
Lumens
80
130
%Lamp
0.89
1.45
%Fixture
1.10
1.80
Angle
in Deg
45
0-Deg
cd/sm
1296
45-Deg
cd/sm
1304
90-Deg
cd/sm
1304
0-60
0-90
40-90
233
302
171
2.59
3.36
1.91
3.21
4.16
2.36
55
65
75
1232
1018
652
1242
1189
726
1291
1347
1242
60-90
90-180
0-180
69
6969
7272
.77
77.44
80.80
.95
95.84
100.00
85
516
953
1281
o
Angle
COMMON CIRCUIT CONFIGURATIONS
2C =T wo circuit luminaire
2E =T wo circuit luminaire with emergency circuit
2C
1B =S ingle circuit luminaire with battery pack
48"(1219mm)
=C ircuit 1
=C ircuit 2
2E
=E mergency C ircuit
=B attery C ircuit
96"(2438mm)
=P ower Mount
1B
=Non-P ower Mount
96"(2438mm)
48"(1219mm)
STANDARD ROW CONFIGURATIONS
F IXT UR E
L E NG T H
4'
4'
1
8'
8'
12' 16' 20' 24' 28' 32' 36' 40' 44' 48'
1
1
1
1
2
2
1
3
3
1
4
4
1
5
5
52' 56' 60' 64' 68'
1
6
6
1
7
7
72' 76' 80' 84' 88' 92' 96' 100' 104' 108'
1
8
8
1
9
9
1
10
10
1
11
Specifications and Dimensions subject to change without notice.
Corelite • 18001 E. Colfax Ave. • Aurora, CO 80011 • 303.393.1522 • FAX 303.393.1477
11
1
12
12
1
13
13
ADE090041
05/22/2009 12:50:48 PM
Download