Catalog # Type

advertisement
CORELITE
DESCRIPTION
One of Corelite's latest additions to its line of architectural direct-indirect
extruded fixtures, the Element Wall, features crisp modern lines with a
concave perf aluminum insert, which creates a subtle sparkle while offering
awareness of the light source. The Element Wall may be mounted over
standard 2"x4" J-Boxes for individual or continuous configuration using 4'
and 8' modular sections. The Element Wall is suited for open office
perimeters, private offices, conference rooms, corridors and public spaces.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
Housing is 6063 T5 aluminum
extrusion forming a 2-1/2"
rectilinear profile. Standard 4'-0"
and 8'-0" fixture lengths combine
for continuous runs.
D ... Reflectors
Reflector pan is painted with a
highly reflectance white powder
coat finish. Optional die-formed
side reflector is a highly specular
anodized aluminum.
B ... End Plates
Standard end plates are 14-gauge
cold rolled steel, mechanically
attached without exposed
fasteners.
E ... Electrical
Fixtures are prewired with quick
wire connectors and use UL listed
Class P, 265ma T8 instant start
universal voltage electronic
ballasts. Power factor of 95% with
less than 10% THD. Fixtures and
electrical components certified to
UL and CUL standards.
C ... Louver
Semi-specular material, perforated
section is 15% open with 0.062"
diameter holes and opal diffuser.
A
C
D
E
F ... Finish
Fixture housings are standard
white using electrostatically
applied polyester powder coat
paint.
Mounting
Fixture mounts directly to existing
structure over a 2" x 4" standard
electrical box mounted horizontally
into the wall. Refer to installation
section for details.
Element Wall
Concave Metallic
Perf
2T8
B
F
Wall Mount
Semi-Indirect
Light Distribution
2-1/2"
[64mm]
Indirect - 94.5%
Direct - 5.5%
6-3/4" [171mm]
1/8" [3mm]
End Cap Side View
M O D U L E S A N D D I M E N S I O N S*
48" [1219mm]
96" [2438mm]
*Dimensions do not include end caps.
ORDERING INFORMATION
Sample Number: E2W-WC-2T8-1C-UNV-SU-WA-8
Series
E2W=Element
Wall
Optics Up
S=Specular
W=White
Optics Down
C=Concave Metallic Perf
Number of
Lamps
2=2 Lamps
Lamp Type
T8=T8 Normal Output
Number of Circuits
1=1 Circuit
1
2=2 Circuits
Wiring 1
B=Battery Pack
Voltage 1
120=120V
Suspension
SU-WA=Surface/Wall Mount
C=Standard Circuit
D=Dimming
277=277V
347=347V
Run Length
E=Emergency
T=Nightlight
UNV=Universal
(120V277V)
Continuously Mounted
Y=Daylight
Notes: 1
Individually Mounted
Luminaires may be 4' or 8' in length
Standard row configurations over 8'
consist of 4' and 8' sections
Not all options available. Please consult your Cooper Lighting Representative for availability.
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADE091095
05/29/2009 12:10:09 PM
PHOTOMETRICS
Corelite
Candela
rc
rw
E2W-WC-2T8
(2) F32T8/TL841
3000 Lumens
Test Report
#LSI17913
70
80%
50 30
10
70
70%
50 30
50%
50 30 10
10
30%
50 30 10
10%
50 30 10
0%
0
RCR
0
70
70
70
70
60
60
60
60
43
43
43
26
26
26
11
11
11
04
1
2
3
4
64
58
53
48
61
53
47
41
58
49
42
36
56
45
38
32
55
50
45
41
53
46
40
36
50
42
36
31
48
39
33
28
37
32
29
25
36
30
26
22
35
28
24
20
23
20
18
16
22
19
16
14
22
18
15
13
10
09
08
07
09
08
07
06
09
08
07
06
03
03
02
02
5
6
7
8
44
40
37
34
36
32
29
26
31
27
24
21
27
23
20
17
38
35
32
29
31
28
25
23
27
23
21
18
24
20
17
15
22
20
18
16
19
17
15
13
17
15
13
11
14
12
11
10
12
11
09
08
11
09
08
07
06
05
05
04
05
05
04
04
05
04
04
03
02
02
01
01
9
10
32
29
23
21
18
16
15
13
27
25
20
18
16
14
13
12
15
13
12
10
10
08
09
08
07
07
06
05
04
04
03
03
03
02
01
01
Zonal Lumen Summar y
Angle
0
Along II
82
45o
82
Across I
82
Luminance Data
Zone
0-30
0-40
Lumens
63
104
%Lamp
1.06
1.74
%Fixture
1.47
2.40
Angle
in Deg
45
0-Deg
cd/sm
1013
45-Deg
cd/sm
1038
90-Deg
cd/sm
1125
0-60
0-90
40-90
184
238
134
3.08
3.97
2.23
4.24
5.48
3.08
55
65
75
999
905
715
999
1037
1068
1111
1157
1210
60-90
90-180
0-180
53
4115
4353
.90
68.59
72.56
1.23
94.52
100.00
85
562
922
1359
5
82
82
81
15
25
79
74
77
71
78
72
35
45
55
65
52
42
61
53
42
66
58
46
65
75
85
90
28
13
3
0
32
20
5
0
35
23
8
0
95
105
115
125
42
234
454
666
91
386
716
952
97
397
727
1042
135
145
155
165
175
180
860
1027
1157
1247
1293
1300
1091
1206
1271
1311
1315
1300
1231
1307
1349
1346
1324
1300
COMMON CIRCUIT CONFIGURATIONS
2C =T wo circuit luminaire
2E =T wo circuit luminaire with emergency circuit
2C
1B =S ingle circuit luminaire with battery pack
48"(1219mm)
=C ircuit 1
=C ircuit 2
2E
=E mergency C ircuit
=B attery C ircuit
96"(2438mm)
=P ower Mount
1B
=Non-P ower Mount
96"(2438mm)
48"(1219mm)
STANDARD ROW CONFIGURATIONS
F IXT UR E
L E NG T H
4'
4'
1
8'
8'
12' 16' 20' 24' 28' 32' 36' 40' 44' 48'
1
1
1
1
2
2
1
3
3
1
4
4
1
5
5
52' 56' 60' 64' 68'
1
6
6
1
7
7
72' 76' 80' 84' 88' 92' 96' 100' 104' 108'
1
8
8
1
9
9
1
10
10
1
11
Specifications and Dimensions subject to change without notice.
Corelite • 18001 E. Colfax Ave. • Aurora, CO 80011 • 303.393.1522 • FAX 303.393.1477
11
1
12
12
1
13
13
ADE091095
05/29/2009 12:10:09 PM
Download