Lumark DESCRIPTION The Enclosed and Gasketed Prismatic Acrylic Steeler features a cast aluminum neck for superior strength and a hinged door frame with latches for access to the lamp without tools. The unit is fully enclosed and gasketed at three separate points to prevent entry of external contaminants. U.L. listed and CSA Certified for damp locations. The Enclosed and Gasketed Prismatic Acrylic Steeler is perfect for retail, hangars, assembly and auto service areas. Catalog # Type Project Comments Date Prepared by S P E C I F I C AT I O N F E AT U R E S Construction Electrical HOUSING: Heavy-duty formed steel housing with an open air ballast for cooler operation is finished with white polyester paint. NECK: Cast aluminum neck with staggered inserts for adjustability of the socket providing a variety of distributions from concentrated to wide. BALLAST: High power factor ballast with class H insulation. Minimum starting temperature is -40°C (40°F) for HPS and -30°C (-20°F) for MH. SOCKET: Mogul-base socket standard for HPS. For Metal Halide, protected socket standard, for use with "O" open-rated protected Metal Halide lamps only. The system is completely enclosed and gasketed at three (3) points: door to refractor, refractor to neck, and neck to housing. LENS: Clear tempered glass or prismatic acrylic drop lens in an extruded aluminum hinged door frame with latches allows access for relamping without tools. Mounting Optical REFRACTOR SYSTEM: Prismatic acrylic refractor provides maximum photometric performance and beam efficiency. Easy slide-on die-cast aluminum mounting box with tapped opening for 3/4" conduit. SE 22" ENCLOSED & GASKETED PRISMATIC STEELER 175 - 400W High Pressure Sodium Pulse Start Metal Halide Metal Halide ACRYLIC HIGH-BAY DIMENSIONS ENPD22 Maximum Height 28 3/4” [730mm] Drop Bottom Adds 3 1/2” to Overall Height T E C H N I C A L D ATA EISA Compliant G 65° Ambient Environment 55° Ambient Environment (450W and above) External Supply Wire Rating 90° Minimum E N E R G Y D ATA CWA Ballast Input Watts 175W MP HPF (198 Watts)G 200W MP HPF (227 Watts) G 250W MP HPF (283 Watts) G 320W MP HPF (365 Watts) G 350W MP HPF (400 Watts) G 400W MP HPF (452 Watts) G 400W HPS HPF (465 Watts) C ER TEM D YS S S 22” [559mm] TIFIE ADH082396 2015-12-02 11:03:55 SE 22" E&G PRISMATIC STEELER P H OTO M E T R I C S 90 1.7 60 3.4 5.3 7.0 30 CP/1000 MPSE-ENPD22-C-400-120V 400-Watt MP 42,000-Lumen Coated Lamp* *Coated lamp recommended. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Coefficients Of Utilization Effective floor cavity reflectance rc 80% 70% rw 70 50 30 10 70 50 30 10 RCR 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 1 92 87 82 78 86 82 78 74 73 70 67 65 62 60 57 55 54 50 2 83 74 68 62 78 70 64 59 63 58 54 56 52 48 49 46 43 40 3 75 64 56 50 70 61 54 48 54 48 44 48 43 39 42 39 35 32 4 68 56 48 41 64 53 46 40 48 41 36 42 37 33 37 33 30 27 5 61 49 41 34 58 47 39 33 42 35 30 37 32 27 33 28 25 22 6 56 43 35 28 52 41 33 27 36 30 25 32 27 23 29 24 20 18 7 51 38 29 24 48 36 28 23 32 25 21 28 23 19 25 20 17 14 8 47 34 26 20 44 32 24 19 28 22 17 25 20 16 22 18 14 12 9 43 30 22 17 40 28 21 16 25 19 15 22 17 13 20 15 12 10 10 40 27 19 14 37 25 18 14 23 17 12 20 15 11 18 13 10 8 Spacing Criterion 2.3 Zone %Lamp Zone 0-30 8.4 0-90 0-40 17.8 90-180 0-60 42.6 Total Specifications and dimensions subject to change without notice. %Lamp 65.0 26.8 91.8 Candlepower Degree CP 0 3290 5 3337 15 3977 25 4876 35 6643 45 7103 55 6291 65 4397 75 2736 85 2426 90 2498 95 2701 105 2724 115 2374 125 1956 135 1267 145 769 155 657 165 568 175 419 180 399 ADH082396 2015-12-02 11:03:55 SE 22" E&G PRISMATIC STEELER ORDERING INFORMATION Sample Number: MPSE-ENPD22-M-400-MT-Q Lamp Type MP=Pulse Start Metal 1 Halide MH=Metal Halide1, 2 HP=High Pressure 3 Sodium Series SE=E & G Steeler Reflector Type ENPD=Enclosed & Gasketed Prismatic Acrylic Refractor Reflector Diameter 22=22'' Diameter Distribution 4 C=Concentrated M=Medium W=Wide Lamp Wattage MP 175=175W 250=250W 320=320W 400=400W MH 2 175=175W 250=250W Voltage 5 120V=120V Options C3=3' Cord with no plug (Specify Voltage)10 Accessories C3=3' Cord-No Plug - Requires FH-1, FL-1, or 10 208V=208V 240V=240V PC3=3' Cord with NEMA Plug (120V-L5-15P, 10 208V-L6-15P, 347V-L37-20P, AND 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6' Cord) Requires FH-1 or FL-1, or SHK. Example: PC3-120V Use with TPPH-NEMA. Specify Voltage. PC3=3' Cord with NEMA Plug - (120V-L5, 208V-L6-15P, 347V-L37-20P and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6' cord). Requires FH-1 or FL-1, or SHK. Use with TPPH-NEMA. Specify Voltage. 277V=277V 347V=347V 480V=480V MT=Multi-Tap, 6 wired 277V 400=400W TT=Triple-Tap, 7 wired 347V HP 5T=5-Tap8 250=250W 400=400W Socket OR=Open Rated 9 Socket for Metal Halide Lamps __=Non Applicable (HPS or Not compatible with OR Socket) Notes: 1 Open Rated socket and lamp must be used. PHC=Power Cord and Plug (18" Power Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook). Must specify single voltage. PHC-NEMA=Power Cord and NEMA Plug (18" Power Cord and 20 AMP NEMA plug configuration). Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook). P=Pre-set Socket Position from the factory FH-1=Die-cast Aluminum Fixture Hook (with 3/4" threads for easy installation) MH available in non-U.S. markets only. 3 Not available in 175, 200, 320 and 350W. 4 Factory set for concentrated, medium or wide distributions otherwise fixture is shipped in medium setting. 5 Products also available in non-US voltages and 50HZ for international markets. Consult your Cooper Representative for availabiltiy and ordering information. 88% Efficient EISA Compliant MP Fixtures not available in 347V and TT Voltages. 6 Multi-Tap ballast 120/208/240/277V wired 277V. 7 Triple-Tap ballast 120/277/347V wired 347V. 8 5-Tap ballast 120/208/240/277/480V wired 277V. 400W Metal Halide only. 88% efficient EISA Compliant MP fixtures not available in 5-Tap Voltages. 9 Not applicable for HPS. 10 Requires FH-1or FL-1or SHK. 11 Not available with PC3, C3, PHC or MWS. Not available with single circuit MWS special order. 12 30 second time delay when switching from bright to dim. Consult individual lamp manufacturers recommendations for compatible lamps. For use with CWA ballast only. 13 Specify L/TCB when using thru-way mounting box (TWMBS) accessory. 10 PHC=Power Hook Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook) PHC-NEMA=Power Cord and NEMA plug - 18" Power Cord and 20 Amp NEMA plug configuration. Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook) SGB22A=(Not Compatible with WG22 - 400W max.) WG22/SGB22A=Wire guard with 22" Safety glass bottom FWG22/WG22/SGB22A=Full Wire Guard for 22" Reflector and SGB22 lens (400W Max.) MBT=Twin Mount Bracket (Fixtures must be same voltage and without hooks, loops or plugs.) FL-1=Malleable Iron Plated Fixture Loop (with 3/4" threads for easy installation) TPPH=Thru-Way Pendant Power Hook. Requires FL-1 and PHC. Specify Voltage. SHK=Die-cast Aluminum Fixture Hook (with safety screw and 3/4" threads for easy installation) TPPH-F=Thru-Way Pendant Power Hook Single Fuse, 120, 277 or 347 Volt. Requires FL-1 and PHC. Specify Voltage. HSW=Integral LumaWatt Sensor and Control w/ Wide Distribution 2 SHK F1=Single Fuse (120, 277 or 347V only) F2=Double Fuse (208, 240 or 480V only) SCF=3' Aircraft Safety Cable secures Housing to Ceiling (Alternative lengths available. Example: SCF6 = 6' Cable) Q=Quartz Restrike (Hot Strike Only) EM=Quartz Restrike with ''Delay Relay'' (Quartz lamp strikes at both hot and cold starts) EM/SC=Emergency Separate Circuit L/TCB=Less Top Connector Box (Housing shipped less top connector box. (Specify when using TWMBS accessory) LL=Lamp Included TPPH-F2=Thru-Way Pendant Power Hook Double Fused, 208, 240, or 480 Volt. Requires FL-1 and PHC. Specify Voltage. TPPH-F-QD=Thru-Way Pendant Power Hook Single Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (120, 277, or 347V) TPPH-F2-QD=Thru-Way Pendant Power Hook Double Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (208, 240, or 480V) TPPH-NEMA=Thru-Way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. (Specify FH-1=Fixture Hook FL-1=Fixture Loop SHK=Hook with Safety Screw TWMBS=Thru-Way Mounting Box13 SCR=Aircraft Safety Cable-Housing to Reflector W/MWS=MWS Industrial components attached to the fixture at the factory. (Standard cord length is 3 ft. 6 ft. and 11 ft. also available. Please refer to MWS Modular Wiring System section for additional information. HC=LumaWatt Fixture Control Module (Low11 voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit) 12 HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisy-chained between fixtures outside AC conduit run similar to low voltage intercom's, fire alarms and phone systems) LAMP TYPE WATTAGE Pulse Start Metal Halide (MP) 175, 200, 250, 320, 350, 400W Metal Halide (MH) 175, 250, 400W High Pressure Sodium (HP) 250, 400W QLL=Quartz Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped separate from luminaire unless otherewise noted) VOLTAGE CHART MT=Multi-Tap 120/208/240/277 (wired 277V) TT=Triple-Tap 120/277/347 (wired 347V) 5T=5-Tap 9 120/208/240/277/480 (wired 277V) Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. ADH082396 2015-12-02 11:03:55