COOPER LIGHTING - METALUX

advertisement
COOPER LIGHTING - METALUX
®
DESCRIPTION
The F-Bay I5 series is an outstanding solution for high mounting height
industrial or retail applications. The F-Bay I5 optic has been optimized to
provide maximum performance from T5 lamps. Optional uplight
component is provided to enable excellent ceiling uniformity. The I5’s
high lumen package allows the benefits of fluorescent to be applied at high
mounting heights that were traditionally exclusive to H.I.D. The primary
benefits include exceptional color rendering, high system efficacy, 95%
lumen maintenance, long lamp life, instant on/instant re-strike, economical
dimming, and uniform brightness control. Primary applications include “big
box” retail, shopping malls, light industrial, school gymnasiums, etc.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
Construction
Downlight/Uplight Optics
Mounting
Specification grade full body
housing, end plates and socket
tracks are die formed cold rolled
steel in 4' or 8' lengths. The
housing features an integral ballast
channel that adds strength and
provides numerous KO’s for easy
installation.
Optical modules are fully enclosed
inside housing to protect against
damage. Die formed reflectors are
faceted with two optical
distributions – medium and wide.
Medium beam optical modules
utilize 95% specular aluminum
finish. Open downlight design
optimizes performance with uplight
slots available as an option for
nominal 8% uplight component. An
optional attractive thin blade white
baffle adds longitudinal shielding. A
clear or frosted white acrylic lens is
also available. Optional heavy duty
wireguard can be used with or
without the lens or baffle. Latched
retention of shielding optics
(safety leader restraints) allows for
easy access.
The I5 series is suited for
surface, suspension
mounting with optional
wire hook and chain set,
stem or cable mounting.
Top connector box
mounting is also available.
Narrow 11" housing
allows mounting within
12" horizontally from the
nearest edge of the
sprinkler deflector.
Electrical
Class “P” ballasts are positively
secured by mounting bolts. Rotorlock Bi-Pin lampholders. An
optional top ballast access plate
enables service from above without
disturbing the internal optics.
Optional modular power
receptacle meets UL2459 and NEC
410.73 and is UL/cUL rated for
make and break under load from
outside the luminaire to speed
maintenance. UL/cUL listed.
Suitable for damp locations.
F-BAY I5 Series
Options
Integral Occupancy
Sensor available and
provides from 600 sq. ft.
(MS) up to 1250 sq. ft.
(MSO) of coverage at a
maximum mounting
height of 40'.
4' OR 8'
2 LAMPS
T5 Linear Fluorescent
High Bay
Lighting System
Finish
Electrostatically applied baked
white enamel finish is preceded
by a multistage cleaning cycle,
iron phosphate coating with rust
inhibitor.
4-15/16"
[126mm]
11" [280mm]
ENERGY DATA
Input Watts:
LAMP CONFIGURATIONS
MOUNTING DATA
11/16" [18mm] K.O. (2)
for Cable or Pendant Mounting
Top Connector Box
Mounting
Access Plate
2 LAMP
4-15/16"
[126mm]
4-5/8"
[118mm]
11"
[280mm]
11" [280mm]
46" [1168mm]
11/16" [18mm] K.O.
for Cable or Pendant Mounting
Top Connector Box
Mounting
11/16" [18mm] K.O.
for Cable or Pendant Mounting
Access Plate
Luminaire Efficacy Rating
LER =73
Catalog Number: I5-254T5-UPL
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.28
* Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements
** Consult Pre Sales Technical Support.
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO
LOCAL, STATE OR FEDERAL LAWS
11"
[280mm]
Safe and convenient means of
disconnecting power.
46" [1168mm]
92" [2337mm]
COOPER LIGHTING
EB Ballast & T5HO Lamps
254T5 = (117)
8T254T5 = (229)
2-3/4" [70mm]
ADF023027
I5
PHOTOMETRICS
Candela
I5-254T5-UPL
(1) Electronic Ballast
Angle
Along II
(2) F54T5 Lamps
0
3495
4400 lumens
5
3479
10
3438
Spacing criterion:
15
3347
(II) 1.2 x mounting
20
3238
height, (⊥) 1.1 x
25
3091
mounting height
30
2900
35
2711
Efficiency 95.8%
40
2472
Test Report:
45
2214
P31108
50
1939
55
1659
LER =73
60
1357
Yearly Cost of 1000 65
1059
769
lumens, 3000 hrs at 70
75
479
.08 KWH = $3.28
80
85
90
Across ⊥
3495
3623
3682
3478
3202
3049
2601
2120
1753
1480
1194
1070
944
693
381
190
21
2
6
45°
3495
3555
3666
3570
3361
3064
2882
2613
2188
1742
1411
1147
883
757
561
279
100
9
11
239
58
4
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
113
101
89
79
71
64
58
53
48
44
41
113 113
97 94
83 78
72 66
63 57
56 50
50 44
45 39
41 35
37 32
34 29
110
102
93
86
79
73
68
63
59
55
52
110
98
87
77
69
62
57
52
47
44
40
110
95
81
71
62
55
49
44
40
37
34
110
92
77
65
56
49
44
39
35
32
29
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
104
93
83
74
66
60
54
50
46
42
39
99
89
79
71
64
58
52
48
44
41
38
94
85
76
68
61
55
51
46
43
40
37
91
79
68
58
51
45
40
35
32
29
26
104
91
78
68
60
53
48
43
39
36
33
104
88
75
64
55
48
43
38
35
31
29
99
87
75
66
58
52
47
42
38
35
32
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
2759
4329
6889
8036
8433
%Lamp
31.4
49.2
78.3
91.3
95.8
Candela
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
3461
3447
3355
3208
3062
2834
2619
2359
2090
1798
1491
1188
875
588
392
267
160
73
4
Across ⊥
3461
3602
3707
3502
3263
3078
2660
2122
1793
1453
1246
1117
877
626
407
227
56
29
12
45°
3461
3524
3660
3530
3280
2961
2749
2442
2061
1633
1336
1039
840
710
502
293
191
113
54
Coefficients of Utilization
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
113
105
96
88
81
75
70
65
60
57
53
I5-254T5-TBW-UPL
(2) Electronic Ballasts
(2) F54T5 Lamps
4400 lumens
Spacing criterion:
(II) 1.1 x mounting
height, (⊥) 1.2 x
mounting height
Efficiency 90.2%
Test Report:
931109
LER =68
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.53
%Fixture
32.7
51.3
81.7
95.3
100.0
Average
0-Deg
cd/sm
9384
8668
7510
5547
1994
99
85
72
62
54
48
42
38
34
31
28
94
83
73
64
57
51
45
41
38
34
32
94
81
70
61
53
47
41
37
34
31
28
Average
45-Deg
cd/sm
7383
5993
5368
3231
309
Average
90-Deg
cd/sm
6273
5591
4914
2200
69
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
106
98
90
83
77
71
66
61
57
54
51
106
94
84
75
67
60
55
50
46
42
39
106 106
91 88
78 74
68 63
60 54
53 47
47 42
43 38
39 34
35 31
33 28
103
95
88
81
74
69
64
60
56
52
49
103
92
82
73
65
59
54
49
45
42
39
103
89
77
67
59
52
47
42
38
35
32
103
86
72
62
54
47
42
37
34
31
28
20%
50%
50 30 10
30%
50 30 10
50
98
87
78
69
63
57
52
47
44
40
37
92
83
74
66
60
54
50
46
42
39
36
88
79
71
64
58
52
48
44
41
38
35
98
85
73
64
57
51
45
41
37
34
32
98
82
70
60
52
46
41
37
33
30
28
92
81
71
62
55
49
44
40
37
34
31
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
2697
4168
6453
7511
7939
%Lamp
30.6
47.4
73.3
85.4
90.2
%Fixture
34.0
52.5
81.3
94.6
100.0
Average
0-Deg
cd/sm
7621
6207
4170
3092
2510
92
79
68
58
51
45
40
36
33
30
27
10%
30 10
88
77
68
60
53
48
43
39
36
33
30
88
76
65
57
50
44
40
36
32
29
27
Average
45-Deg
cd/sm
6921
5429
5035
3393
309
0%
0
85
74
63
55
48
42
38
34
31
28
25
Average
90-Deg
cd/sm
6158
5836
4439
2629
997
Modular F-Bay Power Supply Option
Cooper Lighting’s F-Bay Modular Power Supply option is available for use with all F-Bay products. The modular power supply
allows external fixture access for safe and easy servicing. There is no need to remove lamps or reflectors to disconnect fixture
power with F-Bay Modular Power Supply. Access to the individual fixture’s power supply allows servicing without turning off
all the fixtures, disrupting occupants. F-Bay Modular Power Supply is a time saver in installation – simply plug & power.
Code Compliance
• UL/cUL Certified for Make/Break
under load (UL2549)
• Meets NEC requirements for
ballast disconnect (NEC 410.73G)
1
• Allows for addition of Occupancy
Sensor without hard connections
2
1. Modular Power Supply Receptacle supplied
mounted into fixture Access Plate
2. Modular Power Cord & Plugs in 120, 277,
347, & 480V configurations for easy plug &
power into existing supply
No internal fixture
access required for
installation or
disconnecting power
Modular Motion Sensor Option
supplied with Mounting Box and
Modular Power Supply Receptacle
• Receptacles complete with
insulating/dust cap
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
5/12
ADF023027
I5
ORDERING INFORMATION
SAMPLE NUMBER: 8TI5-254T5-TBW-UNV-EBT2-UPL-U
Voltage (3)
UNV=Universal
120/277 Voltage
UNC=Universal
347/480 Voltage (6)
120V=120 Volt
277V=277 Volt
347V=347 Volt
480V=480 Volt
Length
Blank=4' Length
8T=8' Length
Series
I5=T5 Industrial
Mounting Arrangement
Blank=Stand Alone
R=Continuous Row Mount
Ballast Type
T5 Systems
EBT =T5 or T5HO Linear Electronic Program
Rapid Start. Total Harmonic
Distortion < 10% (4)
No. of Ballast
1, 2 or 3
EHT =T5HO Linear Electronic Start High
Ambient. Total Harmonic
Distortion < 10% (6) (7)
No. of Ballast
1, 2 or 3
Options
I5 Lamps Installed
L5830=T5 Lamp, 85CRI 3000K
L5835=T5 Lamp, 85CRI 3500K DIM=Dimming (ballast must be specified)
L5841=T5 Lamp, 85CRI 4100K
L5850=T5 Lamp, 85CRI 5000K
GL=Single Element Fuse
GM=Double Element Fuse
EL=Emergency Installed (3)
No. of Lamps
2=2 Lamps
Lamp Type
28T5=28W T5 Std (4') Lamps
49T5=49W T5HO (4') Lamps
51T5=51W T5HO (4') Lamps
54T5=54W T5HO (4') Lamps
Distribution Optic
Blank=Medium (Specular Aluminum)
G=Wide (High Reflectance White)
Shielding Options
Blank=Open
TBW=Thin White Baffle
FL=Frosted Acrylic Lens
& Frame (2)
CL=Clear Acrylic Lens &
Door Frame
ASY= Asymmetric
Directional Louver (2)
WG=Heavy Duty
Wireguard
NOTES: (1) Requires use of MC or MPC cord accessories, specify voltage for plugs. (2) Use with wide distribution optic
only. (3) Voltage must be specified when ordered with plugs, motion sensor or emergency ballasts. (4) EBT ballast
systems suitable for operation in ambient environments up to 104°F (40°C). (5) ER8 and EB8 ballast systems suitable for
operation in ambient environments up to 122°F (50°C) in open uplight configurations. (6) 2 lamp ballast configurations
only in T5 UNC versions. 2/3 lamp ballast configurations in EB/PLUS only for T8 UNC. (7) EHT ballast systems suitable
for ambient environments not to exceed 149°F (65°C) in open uplight configurations and less lens option. (8) Not for use
in gymnasiums or similar recreational facilities. (9) When ordering MS option, specify UNV (for 120 or 277V), 347 or
480V. (10) Cannot be combined with Modular Power Receptacle (MP). (11) For MWS with MP, choose MP in fixture logic
and then choose MWS accessory such as MDS6.
Packaging
Options
NUA=No Uplight Apertures In Housing U=Unit Pack
PAL=Palletized
(Cannot be combined w/UPL)
Out of Carton
UPL=Uplight Apertures
PALC=Palletized
PI/CPI=Plug-In (1, 2 or 3)
In Carton
TILW=Tandem Inline Wiring
(10)
MWS=Modular Wiring System
MS=360° or 180° Motion Sensor , 120 through
347 , or 480V (11)
MP=Modular Power Receptacle (Used for
all Cord or Cord and Plug options) (1), (11)
Accessories (order separately)
I5/I8-SPM=Single Monopoint Hanger w/Hub
RH-1=Retrofit Hanger
FH-1=Fixture Hook
FL-1=Fixture Loop
SHK=Hook w/ Safety Screw
AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks (8)
TOGGLE- =Single Toggle, #2 Cable (Specify 10' or 30')
LOOP- =Loop Hanger, #2 Cable (Specify 10' or 30')
MC6=6' Modular Power Cord
MPC6=6' Modular Power Cord & Plug (Specify Voltage)
MMS=360° or 180° Aisle Motion Sensor with Modular
Power Receptacle (120-277V) (1)
MDS6=6' Modular Power Cord with MWS
27DS18/2G06MP Connector (11)
Door Frames (for Field Installation)
I5-FRM/LENS=Frosted Acrylic Lens & Frame (I5)
I5-FRM/CL PK=Clear Acrylic Lens & Frame (I5)
WG/I5-4FT-B=Heavy Duty Wireguard (I5)
90800PPK=Thin White Blade Baffle (I5)
90801PPK=Asymmetrical Directional Louver (I5)
SHIPPING INFORMATION
Catalog No.
Wt.
I5-254T5-TBW-UPL
8TI5-254T5-TBW-UPL
15 lbs.
30 lbs.
PI OPTION ORDERING INFORMATION
Catalog
Number
Suffix
PI 1 BLK
PI 2 BLU
PI 2 BLK
Number of
Circuits
1
2
2
Circuit
Wired To
Ballast
Black
Blue
Black
PI 3 RED
PI 3 BLU
PI 3 BLK
3
3
3
Red
Blue
Black
Catalog Numbering System
The PI System is available in sections up to 8' in length for continuous row wiring by simply plugging the sections
together. Each PI section is factory wired to the ballast leads. Color coding of wires is as follows:
PI-1 = One Circuit - 2 Wires: one black, one white
PI-2 = Two Circuits - 3 Wires: one black, one blue, one white
PI-3 = Three Circuits - 4 wires: one black, one blue, one red, one white
When ordering the PI2/PI3 System it is necessary to specify the number of fixtures required for each circuit. Each circuit in
fixture must be ordered as a separate line item, with a different hot wire color specified. All wiring to external feeds, using
cord or cord & plug, are responsibility of installing licensed contractor. Cord and cord & plug sets must be ordered
separately if PI option is chosen.
PI1 - Single Circuit Plug-In
PI2 - Two Circuit Plug-In
PI3 - Three Circuit Plug-In
SAMPLE NUMBER: PI1BLK-WG
SAMPLE NUMBER: PI2BLK-WG
SAMPLE NUMBER: PI3BLK-WG
PI1= Single
Circuit
BLK=Black Hot
NG= No Ground (ground
provided by fixture body)
WG= With Ground
(separate ground wire
in harness)
For complete product data, reference the Fluorescent
Specification binder. Specifications & dimensions subject
to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
PI2= Two
Circuit
BLK=Black Hot
BLU=Blue Hot
Leave Blank=Single
Neutral
/WHT=White Neutral
/GRY=Gray Neutral
Leave Blank=Single
Neutral
2NEU=Two Neutrals
NG= No Ground (ground
provided by fixture body)
WG= With Ground (separate
ground wire in harness)
PI3= Three
Circuit
Leave Blank=Single Neutral
2NEU=Two Neutrals
BLK=Black Hot
BLU=Blue Hot
RED=Red Hot
NG= No Ground (ground
provided by fixture body)
WG= With Ground (separate
ground wire in harness)
Leave Blank=Single
Neutral
/WHT=White Neutral
/GRY=Gray Neutral
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
5/12
ADF023027
Download