COOPER LIGHTING - METALUX ® DESCRIPTION The F-Bay I5 series is an outstanding solution for high mounting height industrial or retail applications. The F-Bay I5 optic has been optimized to provide maximum performance from T5 lamps. Optional uplight component is provided to enable excellent ceiling uniformity. The I5’s high lumen package allows the benefits of fluorescent to be applied at high mounting heights that were traditionally exclusive to H.I.D. The primary benefits include exceptional color rendering, high system efficacy, 95% lumen maintenance, long lamp life, instant on/instant re-strike, economical dimming, and uniform brightness control. Primary applications include “big box” retail, shopping malls, light industrial, school gymnasiums, etc. Type Catalog # Project Date Comments Prepared by SPECIFICATION FEATURES Construction Downlight/Uplight Optics Mounting Specification grade full body housing, end plates and socket tracks are die formed cold rolled steel in 4' or 8' lengths. The housing features an integral ballast channel that adds strength and provides numerous KO’s for easy installation. Optical modules are fully enclosed inside housing to protect against damage. Die formed reflectors are faceted with two optical distributions – medium and wide. Medium beam optical modules utilize 95% specular aluminum finish. Open downlight design optimizes performance with uplight slots available as an option for nominal 8% uplight component. An optional attractive thin blade white baffle adds longitudinal shielding. A clear or frosted white acrylic lens is also available. Optional heavy duty wireguard can be used with or without the lens or baffle. Latched retention of shielding optics (safety leader restraints) allows for easy access. The I5 series is suited for surface, suspension mounting with optional wire hook and chain set, stem or cable mounting. Top connector box mounting is also available. Narrow 11" housing allows mounting within 12" horizontally from the nearest edge of the sprinkler deflector. Electrical Class “P” ballasts are positively secured by mounting bolts. Rotorlock Bi-Pin lampholders. An optional top ballast access plate enables service from above without disturbing the internal optics. Optional modular power receptacle meets UL2459 and NEC 410.73 and is UL/cUL rated for make and break under load from outside the luminaire to speed maintenance. UL/cUL listed. Suitable for damp locations. F-BAY I5 Series Options Integral Occupancy Sensor available and provides from 600 sq. ft. (MS) up to 1250 sq. ft. (MSO) of coverage at a maximum mounting height of 40'. 4' OR 8' 2 LAMPS T5 Linear Fluorescent High Bay Lighting System Finish Electrostatically applied baked white enamel finish is preceded by a multistage cleaning cycle, iron phosphate coating with rust inhibitor. 4-15/16" [126mm] 11" [280mm] ENERGY DATA Input Watts: LAMP CONFIGURATIONS MOUNTING DATA 11/16" [18mm] K.O. (2) for Cable or Pendant Mounting Top Connector Box Mounting Access Plate 2 LAMP 4-15/16" [126mm] 4-5/8" [118mm] 11" [280mm] 11" [280mm] 46" [1168mm] 11/16" [18mm] K.O. for Cable or Pendant Mounting Top Connector Box Mounting 11/16" [18mm] K.O. for Cable or Pendant Mounting Access Plate Luminaire Efficacy Rating LER =73 Catalog Number: I5-254T5-UPL Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.28 * Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements ** Consult Pre Sales Technical Support. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS 11" [280mm] Safe and convenient means of disconnecting power. 46" [1168mm] 92" [2337mm] COOPER LIGHTING EB Ballast & T5HO Lamps 254T5 = (117) 8T254T5 = (229) 2-3/4" [70mm] ADF023027 I5 PHOTOMETRICS Candela I5-254T5-UPL (1) Electronic Ballast Angle Along II (2) F54T5 Lamps 0 3495 4400 lumens 5 3479 10 3438 Spacing criterion: 15 3347 (II) 1.2 x mounting 20 3238 height, (⊥) 1.1 x 25 3091 mounting height 30 2900 35 2711 Efficiency 95.8% 40 2472 Test Report: 45 2214 P31108 50 1939 55 1659 LER =73 60 1357 Yearly Cost of 1000 65 1059 769 lumens, 3000 hrs at 70 75 479 .08 KWH = $3.28 80 85 90 Across ⊥ 3495 3623 3682 3478 3202 3049 2601 2120 1753 1480 1194 1070 944 693 381 190 21 2 6 45° 3495 3555 3666 3570 3361 3064 2882 2613 2188 1742 1411 1147 883 757 561 279 100 9 11 239 58 4 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 113 101 89 79 71 64 58 53 48 44 41 113 113 97 94 83 78 72 66 63 57 56 50 50 44 45 39 41 35 37 32 34 29 110 102 93 86 79 73 68 63 59 55 52 110 98 87 77 69 62 57 52 47 44 40 110 95 81 71 62 55 49 44 40 37 34 110 92 77 65 56 49 44 39 35 32 29 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 104 93 83 74 66 60 54 50 46 42 39 99 89 79 71 64 58 52 48 44 41 38 94 85 76 68 61 55 51 46 43 40 37 91 79 68 58 51 45 40 35 32 29 26 104 91 78 68 60 53 48 43 39 36 33 104 88 75 64 55 48 43 38 35 31 29 99 87 75 66 58 52 47 42 38 35 32 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 2759 4329 6889 8036 8433 %Lamp 31.4 49.2 78.3 91.3 95.8 Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 3461 3447 3355 3208 3062 2834 2619 2359 2090 1798 1491 1188 875 588 392 267 160 73 4 Across ⊥ 3461 3602 3707 3502 3263 3078 2660 2122 1793 1453 1246 1117 877 626 407 227 56 29 12 45° 3461 3524 3660 3530 3280 2961 2749 2442 2061 1633 1336 1039 840 710 502 293 191 113 54 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 113 105 96 88 81 75 70 65 60 57 53 I5-254T5-TBW-UPL (2) Electronic Ballasts (2) F54T5 Lamps 4400 lumens Spacing criterion: (II) 1.1 x mounting height, (⊥) 1.2 x mounting height Efficiency 90.2% Test Report: 931109 LER =68 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.53 %Fixture 32.7 51.3 81.7 95.3 100.0 Average 0-Deg cd/sm 9384 8668 7510 5547 1994 99 85 72 62 54 48 42 38 34 31 28 94 83 73 64 57 51 45 41 38 34 32 94 81 70 61 53 47 41 37 34 31 28 Average 45-Deg cd/sm 7383 5993 5368 3231 309 Average 90-Deg cd/sm 6273 5591 4914 2200 69 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 106 98 90 83 77 71 66 61 57 54 51 106 94 84 75 67 60 55 50 46 42 39 106 106 91 88 78 74 68 63 60 54 53 47 47 42 43 38 39 34 35 31 33 28 103 95 88 81 74 69 64 60 56 52 49 103 92 82 73 65 59 54 49 45 42 39 103 89 77 67 59 52 47 42 38 35 32 103 86 72 62 54 47 42 37 34 31 28 20% 50% 50 30 10 30% 50 30 10 50 98 87 78 69 63 57 52 47 44 40 37 92 83 74 66 60 54 50 46 42 39 36 88 79 71 64 58 52 48 44 41 38 35 98 85 73 64 57 51 45 41 37 34 32 98 82 70 60 52 46 41 37 33 30 28 92 81 71 62 55 49 44 40 37 34 31 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 2697 4168 6453 7511 7939 %Lamp 30.6 47.4 73.3 85.4 90.2 %Fixture 34.0 52.5 81.3 94.6 100.0 Average 0-Deg cd/sm 7621 6207 4170 3092 2510 92 79 68 58 51 45 40 36 33 30 27 10% 30 10 88 77 68 60 53 48 43 39 36 33 30 88 76 65 57 50 44 40 36 32 29 27 Average 45-Deg cd/sm 6921 5429 5035 3393 309 0% 0 85 74 63 55 48 42 38 34 31 28 25 Average 90-Deg cd/sm 6158 5836 4439 2629 997 Modular F-Bay Power Supply Option Cooper Lighting’s F-Bay Modular Power Supply option is available for use with all F-Bay products. The modular power supply allows external fixture access for safe and easy servicing. There is no need to remove lamps or reflectors to disconnect fixture power with F-Bay Modular Power Supply. Access to the individual fixture’s power supply allows servicing without turning off all the fixtures, disrupting occupants. F-Bay Modular Power Supply is a time saver in installation – simply plug & power. Code Compliance • UL/cUL Certified for Make/Break under load (UL2549) • Meets NEC requirements for ballast disconnect (NEC 410.73G) 1 • Allows for addition of Occupancy Sensor without hard connections 2 1. Modular Power Supply Receptacle supplied mounted into fixture Access Plate 2. Modular Power Cord & Plugs in 120, 277, 347, & 480V configurations for easy plug & power into existing supply No internal fixture access required for installation or disconnecting power Modular Motion Sensor Option supplied with Mounting Box and Modular Power Supply Receptacle • Receptacles complete with insulating/dust cap Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 5/12 ADF023027 I5 ORDERING INFORMATION SAMPLE NUMBER: 8TI5-254T5-TBW-UNV-EBT2-UPL-U Voltage (3) UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage (6) 120V=120 Volt 277V=277 Volt 347V=347 Volt 480V=480 Volt Length Blank=4' Length 8T=8' Length Series I5=T5 Industrial Mounting Arrangement Blank=Stand Alone R=Continuous Row Mount Ballast Type T5 Systems EBT =T5 or T5HO Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10% (4) No. of Ballast 1, 2 or 3 EHT =T5HO Linear Electronic Start High Ambient. Total Harmonic Distortion < 10% (6) (7) No. of Ballast 1, 2 or 3 Options I5 Lamps Installed L5830=T5 Lamp, 85CRI 3000K L5835=T5 Lamp, 85CRI 3500K DIM=Dimming (ballast must be specified) L5841=T5 Lamp, 85CRI 4100K L5850=T5 Lamp, 85CRI 5000K GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (3) No. of Lamps 2=2 Lamps Lamp Type 28T5=28W T5 Std (4') Lamps 49T5=49W T5HO (4') Lamps 51T5=51W T5HO (4') Lamps 54T5=54W T5HO (4') Lamps Distribution Optic Blank=Medium (Specular Aluminum) G=Wide (High Reflectance White) Shielding Options Blank=Open TBW=Thin White Baffle FL=Frosted Acrylic Lens & Frame (2) CL=Clear Acrylic Lens & Door Frame ASY= Asymmetric Directional Louver (2) WG=Heavy Duty Wireguard NOTES: (1) Requires use of MC or MPC cord accessories, specify voltage for plugs. (2) Use with wide distribution optic only. (3) Voltage must be specified when ordered with plugs, motion sensor or emergency ballasts. (4) EBT ballast systems suitable for operation in ambient environments up to 104°F (40°C). (5) ER8 and EB8 ballast systems suitable for operation in ambient environments up to 122°F (50°C) in open uplight configurations. (6) 2 lamp ballast configurations only in T5 UNC versions. 2/3 lamp ballast configurations in EB/PLUS only for T8 UNC. (7) EHT ballast systems suitable for ambient environments not to exceed 149°F (65°C) in open uplight configurations and less lens option. (8) Not for use in gymnasiums or similar recreational facilities. (9) When ordering MS option, specify UNV (for 120 or 277V), 347 or 480V. (10) Cannot be combined with Modular Power Receptacle (MP). (11) For MWS with MP, choose MP in fixture logic and then choose MWS accessory such as MDS6. Packaging Options NUA=No Uplight Apertures In Housing U=Unit Pack PAL=Palletized (Cannot be combined w/UPL) Out of Carton UPL=Uplight Apertures PALC=Palletized PI/CPI=Plug-In (1, 2 or 3) In Carton TILW=Tandem Inline Wiring (10) MWS=Modular Wiring System MS=360° or 180° Motion Sensor , 120 through 347 , or 480V (11) MP=Modular Power Receptacle (Used for all Cord or Cord and Plug options) (1), (11) Accessories (order separately) I5/I8-SPM=Single Monopoint Hanger w/Hub RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop SHK=Hook w/ Safety Screw AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks (8) TOGGLE- =Single Toggle, #2 Cable (Specify 10' or 30') LOOP- =Loop Hanger, #2 Cable (Specify 10' or 30') MC6=6' Modular Power Cord MPC6=6' Modular Power Cord & Plug (Specify Voltage) MMS=360° or 180° Aisle Motion Sensor with Modular Power Receptacle (120-277V) (1) MDS6=6' Modular Power Cord with MWS 27DS18/2G06MP Connector (11) Door Frames (for Field Installation) I5-FRM/LENS=Frosted Acrylic Lens & Frame (I5) I5-FRM/CL PK=Clear Acrylic Lens & Frame (I5) WG/I5-4FT-B=Heavy Duty Wireguard (I5) 90800PPK=Thin White Blade Baffle (I5) 90801PPK=Asymmetrical Directional Louver (I5) SHIPPING INFORMATION Catalog No. Wt. I5-254T5-TBW-UPL 8TI5-254T5-TBW-UPL 15 lbs. 30 lbs. PI OPTION ORDERING INFORMATION Catalog Number Suffix PI 1 BLK PI 2 BLU PI 2 BLK Number of Circuits 1 2 2 Circuit Wired To Ballast Black Blue Black PI 3 RED PI 3 BLU PI 3 BLK 3 3 3 Red Blue Black Catalog Numbering System The PI System is available in sections up to 8' in length for continuous row wiring by simply plugging the sections together. Each PI section is factory wired to the ballast leads. Color coding of wires is as follows: PI-1 = One Circuit - 2 Wires: one black, one white PI-2 = Two Circuits - 3 Wires: one black, one blue, one white PI-3 = Three Circuits - 4 wires: one black, one blue, one red, one white When ordering the PI2/PI3 System it is necessary to specify the number of fixtures required for each circuit. Each circuit in fixture must be ordered as a separate line item, with a different hot wire color specified. All wiring to external feeds, using cord or cord & plug, are responsibility of installing licensed contractor. Cord and cord & plug sets must be ordered separately if PI option is chosen. PI1 - Single Circuit Plug-In PI2 - Two Circuit Plug-In PI3 - Three Circuit Plug-In SAMPLE NUMBER: PI1BLK-WG SAMPLE NUMBER: PI2BLK-WG SAMPLE NUMBER: PI3BLK-WG PI1= Single Circuit BLK=Black Hot NG= No Ground (ground provided by fixture body) WG= With Ground (separate ground wire in harness) For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. PI2= Two Circuit BLK=Black Hot BLU=Blue Hot Leave Blank=Single Neutral /WHT=White Neutral /GRY=Gray Neutral Leave Blank=Single Neutral 2NEU=Two Neutrals NG= No Ground (ground provided by fixture body) WG= With Ground (separate ground wire in harness) PI3= Three Circuit Leave Blank=Single Neutral 2NEU=Two Neutrals BLK=Black Hot BLU=Blue Hot RED=Red Hot NG= No Ground (ground provided by fixture body) WG= With Ground (separate ground wire in harness) Leave Blank=Single Neutral /WHT=White Neutral /GRY=Gray Neutral Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 5/12 ADF023027