iLumin Technical Data RRU-1 – UL 924 Remote Relay Unit Catalog# Prepared by Project Date Comments Type Overview The The Remote Relay Unit (RRU-1) is available in 120 VAC and 277 VAC input voltage configurations. The RRU-1 is designed to force all outputs in the lighting control panel to an emergency scene regardless of the control panel’s programmed output status. This allows the override of outputs during loss of normal (grid) power to allow an alternate power source to drive the lighting loads (Once the RRU-1 senses the normal power returning, the control panel will return to the normal programmed operating mode). Features UL 924 Listed Accessory Detects loss of normal power and automatically sends signal to lighting control panel RRU-1 – UL 924 Remote Relay Unit July 2015 Features Ethernet link Switch Input 2 L L Switch Input 1 DMX- DMX+ OV Shield L Compatibility Standards UL 924 Listed Connects to normal power for monitoring Architectural Dimming System must be fed from alternate power SC-UN, SC-FT, SC-RP, SC-RPB L General Electrical Data Mechanical Data Wiring Diagram DMX UL Approved UL 924 Listed Contact closure +12V CAN-H DRAIN CAN-L DV (red) (white) (gray) (blue) (black) RS485- RS485+ OV Shield For Emergency panel configurations, ensure the Source Controller is fed from an emergency power source. The RRU-1 needs to provide a dry contact maintained closure to the Switch Input 1 or Switch Input 2 terminal on the Source Controller input card. Emergency actions can be programmed from the Source Controller on board user interface. RS485 Operation iCAN The RRU-1 provides a Normally Closed (N/C) dry contact closure to the Source Controller panel when normal (grid) power is lost. This contact closure performs an override of all outputs in the enclosure to an emergency scene. This override condition takes priority over any output commands from the system controller and will remain in effect until the contact closure from the RRU-1 is opened. Switch Input 1 Switch Input 2 iLumin Contact inputs To override On: Connect dry contact from RRU-1 to Switch Input 1 or Switch Input 2. Installation The RRU-1 can be installed next to the Source Controller. Red (14 AWG) When contact closes all relays/dimmers are forced to an emergency scene. Contact of the RRU-1 will close when normal power is lost. Black (14 AWG) NC C SPST Relay C Neutral = White (16 AWG) Hot 120 VAC = Black Hot 277 VAC = Orange To Normal Power Source (16 AWG) To Normal Power Circuit Ordering This is an accessory with the SC-UN, SC-FT, SC-RP, SC-RPB Source Controllers. When ordering, specify the RRU-1 as a separate system accessory. Catalog # Descriptoin Rating RRU-1-120V RRU-1-277V UL924 Remote Relay Unit UL924 Remote Relay Unit 120 VAC 277 VAC Note: Note: for 347 VAC Applications please see Model LRM-347 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Lighting systems 203 Cooper Circle Peachtree City, GA 30269 www.eaton.com/lightingsystems © 2015 Eaton All Rights Reserved Printed in USA Publication No. TD503028EN July 30 2015 Eaton is a registered trademark. All other trademarks are property of their respective owners. In cooperation with: LVS,Inc.