COOPER LIGHTING - CORELITE Type Catalog # Project

advertisement
COOPER LIGHTING - CORELITE
DESCRIPTION
The RZL is a suspended/surface linear direct and semi-direct LED continuous
row solution for new and retrofit construction. Designed for larger open
ceiling environments, the RZL offers advanced LED technology and optical
distributions that deliver high quality soft diffuse illumination while
minimizing installation costs with the abiltiy to mount continuously with 4, 8
and 12 foot modular sections. The wide variety of styles and lumen outputs
available make it easy to use in a variety of building environments including
aisleways, open offices, retail, educational facilties and low bay applications.
®
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
Electrical
Fixture equipped with proprietary
Eaton’s Cooper Lighting solid state
light engines. LEDs are available
in 3000K, 3500K or 4000K with
a typical CRI ≥ 85. Modules are
coupled with high efficiency
electronic LED drivers for optimal
preformance. Standard drivers
are 0-10 volt continuous dimming
that work with any 0-10V control/
dimmer; specify -STD in driver
options. The RZL is Powered by
Fifth Light with Digital Addressable
Lighting Interface (DALI) drivers;
specify -FLT in driver options.
Construction
Compact 3.5”x 6.4” profile with
a die-formed 20 gauge cold rolled
steel upper channel for strength
and rigidity combined with a dieformed aluminum lower housing.
End Caps & Joining Covers
End caps and joiner covers are
injection molded polycarbonate,
mechanically attached with no
fasteners.
Sheilding
NL option: solid aluminum sides
with frosted linear prismatic lay-in
flat acrylic lens, 0.125 inches thick.
3.5”
[89mm]
Mounting
Surface mount - custom junction box
cover plate supports the fixture at the
power mount and connects to a 4”
octagonal junction, by others. All other
mounts interface to 1/4” -20 studs by
others protruding from the ceiling.
1/2” standoffs provided by Corelite
required between surface and fixture.
Mounting centers for the first fixture
is the length of the fixture less 2-3/8”,
all other mounting centers are 4’, 8’
or 12’ on-center. Refer to installation
instructions for more details.
Finish
Fixture housings are high reflectance
white (standard) using electrostatically
applied polyester powder coat paint.
Silver and custom colors are available.
Injection molded pieces are color
matched.
RZL-NL
Downlight
Frosted Linear Prismatic
LED
Compliance
Components are UL recognized and
luminaires are cULus listed for 25ºC
ambient environments , damp location
listed, and RoHS compliant.
Surface
Direct
Light Distribution
Direct - 100%
Indirect 0%
Life and Warranty
Greater than 70% lumen maintenance
expected at 60,000 hours, based off
LM-80 test data and TM-21 standards.
Five-year warranty.
6.4”
[163mm]
Fixture Lengths
48” (1219mm)
96” (2483mm)
144” (3658mm)
ORDERING INFORMATION
Sample Number: RZL-NL-3L35-1D-UNV-SU-JB-12’-STD-W
Series
RZL = L
inear Direct LED
Luminaire
Optics Up
Optics Down
N= N
one (100%
downlight)
Suspension
SU-JB
=
urface Mount - Junction
S
Box
L= F
rosted Linear
Prismatic Lens
Light Level
(per 4’ section, 3500K)
1 = Light Level 1(3030 Lms, 30 W)
2 = Light Level 2 (4040 Lms, 42 W)
3 = Light Level 3 (5050 Lms, 48 W)
4 = Light Level 4 (6560 Lms, 66 W)
5 = Light Level 5 (8070 Lms 84 W)
Run Length
4
8 =
12 =
XX =
=
ft
4
8 ft
12 ft
Specify Row Length (4)
Color
Temperature
L30 = LED 3000K
L35 = LED 3500K
L40 = LED 4000K
STD Standard 0-10V
5LT = Fiftht Light DALI
STP = Step-Dim (Bi-Level)
1 = 1 Circuit
Wiring
Input Voltage
C = Switched Circuit (1)
D = 0-10V Dimming (1)
B = Battery (2)
E = Emergency Circuit
T = Night Light
Y = Daylight
Integral Sensor
(Optional)
Driver Options
=
Number of
Circuits
SV
=
Integral Occupancy/Daylight
Sensor (5)
NOTES: (1)Dimming wires come standard with all fixtures. Control wires can be capped in the field for
standard switched circuit operation. (2)Battery pack test switch located on the endcap for surface mount
configurations. (3)Consult factory for 347V availablity. (4)Standard row configurations over 12’ are built with 8’
and 12’ luminaires. (5) Sensor must be combined with 0-10V dimming driver.
120 = 120V
277 = 277V
UNV = Universal
(120V-277V)
347 = 347V (3)
Finish
W White (Standard)
S = Silver
CC = Custom Color
=
ADE142755
11/6/2014
PHOTOMETRICS
90˚
RZL-NL-1L35-1CUNV-4
75˚
400
60˚
800
45˚
1200
0˚
15˚
30˚
Linear LED 3500K
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 1.2 x
mounting height
Lumens: 3027
Input Watts: 30.0W
Efficacy: 101 LPW
Test Report:
RZL-NL-1L35-1CUNV-4.IES
90˚
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
883
1428
2435
3027
3027
%Fixture
29.2
47.2
80.4
100.0
100.0
RZL-NL-3L35-1CUNV-4
Candlepower
Average
0-Deg
cd/sm
5259
4716
4103
3421
2878
Along II
1149
1155
1137
1105
1063
1009
944
867
782
691
597
503
409
322
239
164
100
47
0
45°
1149
1146
1130
1102
1064
1012
950
876
796
707
615
520
429
341
259
181
113
54
0
Average
45-Deg
cd/sm
5380
4883
4343
3772
3310
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Across
1149
1141
1126
1100
1063
1012
952
881
803
718
632
541
452
365
280
200
124
58
0
Average
90-Deg
cd/sm
5463
5078
4646
4163
3551
75˚
600
60˚
1300
45˚
2000
0˚
15˚
30˚
Linear LED 3500K
Spacing criterion:
(II) 1.2 x mounting
height, ( ) 1.2 x
mounting height
Lumens: 5046
Input Watts: 48.3W
Efficacy: 105 LPW
Test Report:
RZL-NL-3L35-1CUNV-4.IES
Candlepower
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Eaton’s Cooper Lighting Business
18001 East Colfax Avenue
Aurora, CO 80011
P: 303-393-1522
www.cooperlighting.com
Lumens
1471
2379
4059
5046
5046
%Fixture
29.2
47.2
80.4
100.0
100.0
Specification and
dimensions subject to
change without notice.
Average
0-Deg
cd/sm
8765
7860
6839
5702
4798
Along II
1915
1925
1895
1842
1771
1682
1573
1446
1304
1152
995
838
682
537
398
274
167
78
0
45°
1915
1910
1883
1837
1773
1687
1583
1460
1327
1178
1024
867
715
568
431
302
188
89
0
Average
45-Deg
cd/sm
8966
8139
7238
6286
5508
Across
1915
1902
1877
1834
1771
1687
1586
1469
1338
1196
1052
902
754
608
466
334
206
96
0
Average
90-Deg
cd/sm
9105
8464
7744
6937
5922
ADE142755
11/6/2014
Download