Fail-Safe

advertisement
Fail-Safe
D ES C R IPTION
Fail-Safe Changing Views Series is a new series of visual therapy
luminaires by Cooper Lighting. Designed to bring warmth, ambience,
and positive energy into a variety of environments, these luminaires
help create a calming influence throughout any facility. The CV Series is
designed with an extremely thin profile - less than 1" deep. Choose from
a variety of images in the standard picture gallery to create single or
multiple murals.
Type
Catalog #
Project
Date
Comments
Prepared by
SPE C IFIC A TION FEA T U R E S
M ou n t i n g
L e ns
En erg y
Fits into standard NEMA Type G
grid, 15/16", 1-1/2", or 2".
High quality acrylic photographic
lens.
Energy-efficient. 19.2 input watts
for 2' x 2', 38.4 input watts for 2' x
4' and 4' x 4'. 24V System
Materials
L ED s
Non-ferrous version available for
MRI applications.
Nominal CRI = 72
Nominal Color Temperature
(without image) = 6000K
2 ' X 2 LIGH T B OX
2 ' X 4 L IGH T BOX
24" x 24"
24" x 48"
23-3/4" [603mm]
Overall
7/8"
[23mm]
23-3/4" [603mm]
Overall
7/8"
[23mm]
Changing Views - Visual Therapy
CV-LEL-G
24" x 24" (2' x 2')
24" x 48" (2' x 4')
48" x 48" (4' x 4')
LED
Healthcare: Changing Views
23-3/4"
[603mm]
Overall
47-3/4"
[1213mm]
Overall
RECESSED GRID
4 ' X 4 LIGH T B OX
48" x 48"
47-3/4" [1213mm]
Overall
7/8"
[23mm]
47-3/4"
[1213mm]
Overall
ENERGY DATA
LED Edge Lit
Input Watts:
19.2 for 24" x 24"
38.4 for 24" x 48"
38.4 for 48" x 48"
ADC081394
2016-02-24 16:56:21
C V -LE L-G
S A MPL E IM A GES (FOR C O M P L E T E S E L E C T I O N , VI S I T W W W .COOP E RL IGH T ING.COM)
SFL38
SEL2525
ASP7389
SCPR9034
ORDER ING INFOR M A TION
S A M P L E N U M B E R : C V- L E L- G - 1 2 0 - 4 A - S C N P R 6 1 3
Configuration 4, 7
Product Family
CV=Changing
Views
2' x 2' Fixtures
2A=(1) 2' x 2'
2B=(2) 2' x 2'
2C=(4) 2' x 2'
2D=(6) 2' x 2'
2E=(9) 2' x 2'
2F=(12) 2' x 2'
LEL=LED Light Box
Mounting
G=Grid Ceiling
Frame
2' x 4' Fixtures
4A=(1) 2' x 4'
4B=(2) 2' x 4'
4C=(3) 2' x 4'
4D=(4) 2' x 4'
4E=(5) 2' x 4'
4F=(6) 2' x 4'
____ = Anodized silver
finish (standard) 5
Image Reference 6
NI = No Image (Light Box only)
Transformer(s) 1
Transformer - (Non-dimmable)
1, 8
T41/UNV= 120-277V, 100W
(100W/24V/4.1A/ 50/60HZ)
Transformers - (Dimmable)
4' x 4' Fixtures
4G=(1) 4' x 4'
Voltage
120=120V
277=277V
Options
MRI=Non-ferrous version
1, 2, 3, 8
D120 = 96W/24V/ 1.12A IN / 4A OUT / 50/60HZ
D277 = 96W/24V/ 0.5A IN / 4A OUT / 50/60HZ
Dimming Controls
Notes:
DCC10 = 0 - 10V DC Dimmer Module for T41
transformer, (wires to 24V
DC side). T41 is 100 watts max when
used with DCC10. 0-10V DC wall
dimmer or control system by others
(not included), Ships separately; order
as separate line item.
1 Transformer(s) necessary to operate LED light-box. Order as separate line item. Ships separately.
Check matrix below to determine required number of transformers.
2 Requires magnetic slide dimmer switch, supplied by others.
3 Remote mounted enclosure included.
4 For custom configurations, contact factory.
5 Custom powder coat finishes available. Consult Cooper Lighting for additional information
6 Additional images available. See picture gallery at www.cooperlighting.com for image selection, part numbers and layout options.
7 Nominal grid dimensions, center-to-center are 24" x 24", 24" x 48", or 48" x 48". Consult factory for other grid sizes/ceiling types.
8 Each transformer can power (4) 2’x2’ panels or (2) 2’x4’, or 4’x’4’ panels.
R EC OMMEND ED NUM B ER O F L I G HT B O XE S P E R T R AN S F O R ME R & D IMME R
INPUT WATTS
19.2
38.4
38.4
CONFIGURATION
22
24
44
24” x 24”
SIZE
TRANSFORMER
NON-DIMMABLE
4
T41/UNV
TRANSFORMERS
D120 or D277
DIMMABLE
4
24” x 48”
48” x 48”
Maximum number of light boxes per transformer.
2
2
Maximum number of light boxes per transformer.
2
2
The maximum distance from the transformer to the farthest fixture not to exceed 20’.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
ADC081394
2016-02-24 16:56:21
C V -LE L-G
C ONF IGUR A TION EX A M PL E S
2A
2D
2C
2E
2F
2B
4C
4F
4A
4B
4D
4E
• Select desired imagery from the
gallery (for the most up to date
information visit our web site at
www.cooperhealthcaresolutions.com)
• Select a configuration and
corresponding luminaire layout.
4G
• Indicate all the above information
when placing an order.
Important Note:
Configuration indicates quantity of fixtures. Only one catalog number per configuration is required.
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
ADC081394
2016-02-24 16:56:21
Download