2-Lamp Specification-grade
0-10V Dimming Ballast Specifications
COOPER LIGHTING
EL E C T R O N I C D I MM ING BA LLA ST S WIT H A NA LOG DIMMING CONTR OL (0-10V) FOR TWO (2) LAMP FIXTUR ES
Cooper Controls Electronic Dimming Ballasts, powered by Fifth Light Technology, offer cost-effective, reliable dimming control for linear fluorescent lamps,
down to 3% for T5/T5HO and T8 lamps. These multi-lamp ballasts cover two-lamp fixtures over a range of lamp types and lengths installed in Cooper
Lighting fluorescent lighting fixtures. All of the ballasts have tightly regulated current control to the lamp, quick programmed rapid start circuits, active power
factor correction and lamp end-of-life protection. When used in two-lamp fixtures, the ballast operates in parallel-lamp mode, where if one lamp fails, the
other stays lit. In addition, the Specification Grade ballasts perform true parallel-lamp dimming, ensuring start-up, dimming, and cut-off of the lamps are
tightly coordinated and regulated. The ballasts are ideal for direct integration with Cooper Controls solutions and compatible with a wide variety of analog
controls and photocells.
F E AT U R E S
Ideal for use with 0-10V energy-management systems, daylight
harvesting and local controls
Programmed Rapid Start maximizes lamp life
Helps meet energy codes, including ASHRAE 90.1 and California
Title 24, when applied properly
End-of-lamp-life Shutdown circuit with Auto-reset for safe, long-term operation
Compatible with Energy-Saving and Low-Mercury Lamps
Active Power-factor Correction for maximum energy savings
120-277V input for easy ordering and universal application
Control inputs protected against mis-wiring with built-in line voltage protection
Dimming Range: 3% for T5/T5HO and T8
Starts at any dimmed level without flashing
S TA N D A R D S A N D LIST ING S
cULus Listed (Class P, Type 1 Outdoor, Type CC)
National Electrical Manufacturers Association (NEMA) Premium Rated
Meets ANSI Standard C82.11
Meets FCC CFR 47 Part 18 for EMI and RFI Non-consumer limits
Meets ANSI Standard C62.41
No PCBs
Restriction of Hazardous Substances Directive (RoHS) Compliant
Sound Rated, Class A
Ballast must be grounded in accordance with national and local electrical codes
Control can be wired as Class I or Class II
Complies with Consortium for Energy Efficiency (CEE) standards
P E R F O R M A N C E A ND ELECT RICA L CHA RA CT ERISTICS FOR ALL SINGLE-LAMP BALLASTS
Minimum Dimming Temperature: 50°F (10°C). Energy Saving Lamps: 60°F (16°C)
Minimum Starting Temp: 0°F (-18°C)
Maximum Ambient Temperature: 104°F (40°C)
Maximum Case Temperature: 167°F (75°C)
Ballast Factor: 1.0
Power Factor: > .98
Crest Factor: < 1.7
Total Harmonic Distortion (THD): < 10%
Start time: less than 700ms
P E R F O R M A N C E A ND ELECT RICA L CHA RA CT ERISTICS BY LAMP TYP E
Cooper Part
Number
FLT-232PSUNVS010-R1-C
FLT-228PSUNVS010-R1-C
FLT-254PSUNVS010-R1-C
Lamp
Type
T8
T5
T5HO
Specific
Lamp
Lamp
Watt
Lamp
Length
Lamp
Operation
Voltage
Input
Amps
-120V
Input
Amps
-277V
BEF 120V
BEF 277V
T8
40
4
0.59
0.25
1.24
1.24
T8
32
4
0.47
0.2
1.53
1.53
T8
28
4
0.4
0.17
1.81
1.81
T8
25
3
0.36
0.15
2.02
2.02
T8
17
2
0.25
0.11
2.81
2.81
T8U
32
U
0.49
0.21
1.50
1.50
T8ES
32 (30)
4
0.44
0.19
1.61
1.61
T8ES
32 (25)
4
0.37
0.16
1.98
1.98
T5
28
4
0.55
0.23
1.59
1.59
T5
21
3
0.42
0.17
2.13
2.13
T5
14
2
0.29
0.12
3.03
3.03
T5ES
28 (26)
4
0.52
0.22
1.75
1.75
Parallel
Parallel
120-277
120-277
T5ES
28 (25)
4
0.51
0.21
1.75
1.75
T5HO
54
4
0.94
0.41
0.89
0.89
FT55W
55
4
0.88
0.38
0.86
0.86
FC55T5HO
55
4
0.83
0.38
0.87
0.87
T5HOES
54 (49)
4
0.89
0.37
0.99
0.99
Parallel
120-277
Dimming
Performance
3%
3%
3%
ACF130942 8/5/14
2-Lamp Specification-grade
0-10V Dimming Ballast Specifications
COOPER LIGHTING
D I MMI N G C O N T R O L A P PLICAT IONS A ND SPECIFICAT IONS
Use Purple (+) and Gray (-) for connection to 0-10VDC
0V = Minimum Light Output
Wiring Purple and Gray together provides 3% light output
Can be wired Class I or Class II
Capping Purple and Gray separately provides 100% light output
Ballast will source a maximum of 250µA for control needs
Built-in line voltage protection: Minimum Light Output level will occur
if line voltage is applied
Control must be capable of sinking current supplied by ballast
10VDC = Maximum Light Output
W I RI N G D I A G R A M
Green (ground)
Red
White (neutral)
Red
Black (line)
Yellow
Ballast
Yellow
Purple (control +)
Blue
Gray (control -)
Blue
B ALLAS T D R AWI N G S
1.71
16.88
8.58
16.28
1.18
1.18
9.50
.26
8.90
14.58
1.25
1.00
‘A’ BALLAST
1.18
‘D’ BALLAST
D I MMI N G C U R V E S
Power
120%
Light Output
Power
120%
Light Output
100%
100%
100%
80%
80%
80%
60%
60%
60%
40%
40%
40%
20%
20%
20%
0%
0%
0
1
2
3
4
5
6
7
8
9
10
Power
120%
Light Output
0%
0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6
Control Voltage (VDC)
Control Voltage (VDC)
Control Voltage (VDC)
T5 Dimming Curve
T5HO Dimming Curve
T8 Dimming Curve
7
8
9
10
WARRAN T Y A N D SU P P O RT INFORM AT ION
Cooper Lighting warrants to the purchaser that each factory-installed electronic ballast will be free from defects in material or workmanship for a
period of five (5) years from the date of manufacture when properly installed and under normal conditions of use.
Call (800) 955-4946 or email ballast@cooperindustries.com for warranty information and support.
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Specifications and
dimensions subject to
change without notice.
ACF130942 8/5/14
Download